Simple instrument for measuring cervical dilatation during labour

The construction of a simple disposable instrument for the measurement of cervical dilatation is described. The instrument consists of two clips, a measuring tape and a flexible tube. The measuring tape is fixed to one clip and threaded through the flexible tube, which is fixed to the other clip. Th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physiological measurement 2005-02, Vol.26 (1), p.N1-N7
1. Verfasser: Letić, Milorad
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page N7
container_issue 1
container_start_page N1
container_title Physiological measurement
container_volume 26
creator Letić, Milorad
description The construction of a simple disposable instrument for the measurement of cervical dilatation is described. The instrument consists of two clips, a measuring tape and a flexible tube. The measuring tape is fixed to one clip and threaded through the flexible tube, which is fixed to the other clip. The clips are attached to opposing cervical rims at 3 o'clock and 9 o'clock and the differential displacement of the marking on the measuring tape and free end of the flexible tube is measured. Laboratory measurements were performed in order to determine the error of measurement. The absolute error of measurement with this instrument is 1.5 mm. Clinical measurements were performed on 12 parturients with a single foetus in vertex position and 3 to 4 cm cervical dilatation. The results of measurements were within +/-1 cm error margin of manual assessments. No adverse effects were noted due to the use of the instrument. The instrument did cause minor discomfort to patients during application.
doi_str_mv 10.1088/0967-3334/26/1/N01
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmed_primary_15742886</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>67480963</sourcerecordid><originalsourceid>FETCH-LOGICAL-c373t-143957fe9f88bc000726803e217a135471146a605a9eafa2249e267b6b9876c13</originalsourceid><addsrcrecordid>eNp9kE1LxDAQhoMo7rr6BzxIT4KH2kySJulxWfyCRQ_qOaRpKpF-mbSC_96WLuthwdMc5nnfYR6ELgHfApYywRkXMaWUJYQnkDxjOEJLoBxinorsGC33wAKdhfCJMYAk6SlaQCoYkZIv0frV1V1lI9eE3g-1bfqobH1UWx0G75qPyFj_7YyuosJVute9a5uomFeVztvBn6OTUlfBXuzmCr3f371tHuPty8PTZr2NDRW0j4HRLBWlzUopc4MxFoRLTC0BoYGmTAAwrjlOdWZ1qQlhmSVc5DzPpOAG6Apdz72db78GG3pVu2BsVenGtkNQXDA5PkxHkMyg8W0I3paq867W_kcBVpM4NXlRkxdFuAI1ihtDV7v2Ia9t8RfZmRqBmxlwbbffHhaprihHNj5k_zn-C90lgpI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67480963</pqid></control><display><type>article</type><title>Simple instrument for measuring cervical dilatation during labour</title><source>MEDLINE</source><source>IOP Publishing Journals</source><source>Institute of Physics (IOP) Journals - HEAL-Link</source><creator>Letić, Milorad</creator><creatorcontrib>Letić, Milorad</creatorcontrib><description>The construction of a simple disposable instrument for the measurement of cervical dilatation is described. The instrument consists of two clips, a measuring tape and a flexible tube. The measuring tape is fixed to one clip and threaded through the flexible tube, which is fixed to the other clip. The clips are attached to opposing cervical rims at 3 o'clock and 9 o'clock and the differential displacement of the marking on the measuring tape and free end of the flexible tube is measured. Laboratory measurements were performed in order to determine the error of measurement. The absolute error of measurement with this instrument is 1.5 mm. Clinical measurements were performed on 12 parturients with a single foetus in vertex position and 3 to 4 cm cervical dilatation. The results of measurements were within +/-1 cm error margin of manual assessments. No adverse effects were noted due to the use of the instrument. The instrument did cause minor discomfort to patients during application.</description><identifier>ISSN: 0967-3334</identifier><identifier>EISSN: 1361-6579</identifier><identifier>DOI: 10.1088/0967-3334/26/1/N01</identifier><identifier>PMID: 15742886</identifier><language>eng</language><publisher>England: IOP Publishing</publisher><subject>Adult ; Disposable Equipment ; Equipment Design ; Female ; Humans ; Labor Stage, First ; Obstetrics - instrumentation ; Pregnancy ; Sensitivity and Specificity</subject><ispartof>Physiological measurement, 2005-02, Vol.26 (1), p.N1-N7</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c373t-143957fe9f88bc000726803e217a135471146a605a9eafa2249e267b6b9876c13</citedby><cites>FETCH-LOGICAL-c373t-143957fe9f88bc000726803e217a135471146a605a9eafa2249e267b6b9876c13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://iopscience.iop.org/article/10.1088/0967-3334/26/1/N01/pdf$$EPDF$$P50$$Giop$$H</linktopdf><link.rule.ids>314,776,780,27901,27902,53805,53885</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15742886$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Letić, Milorad</creatorcontrib><title>Simple instrument for measuring cervical dilatation during labour</title><title>Physiological measurement</title><addtitle>Physiol Meas</addtitle><description>The construction of a simple disposable instrument for the measurement of cervical dilatation is described. The instrument consists of two clips, a measuring tape and a flexible tube. The measuring tape is fixed to one clip and threaded through the flexible tube, which is fixed to the other clip. The clips are attached to opposing cervical rims at 3 o'clock and 9 o'clock and the differential displacement of the marking on the measuring tape and free end of the flexible tube is measured. Laboratory measurements were performed in order to determine the error of measurement. The absolute error of measurement with this instrument is 1.5 mm. Clinical measurements were performed on 12 parturients with a single foetus in vertex position and 3 to 4 cm cervical dilatation. The results of measurements were within +/-1 cm error margin of manual assessments. No adverse effects were noted due to the use of the instrument. The instrument did cause minor discomfort to patients during application.</description><subject>Adult</subject><subject>Disposable Equipment</subject><subject>Equipment Design</subject><subject>Female</subject><subject>Humans</subject><subject>Labor Stage, First</subject><subject>Obstetrics - instrumentation</subject><subject>Pregnancy</subject><subject>Sensitivity and Specificity</subject><issn>0967-3334</issn><issn>1361-6579</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE1LxDAQhoMo7rr6BzxIT4KH2kySJulxWfyCRQ_qOaRpKpF-mbSC_96WLuthwdMc5nnfYR6ELgHfApYywRkXMaWUJYQnkDxjOEJLoBxinorsGC33wAKdhfCJMYAk6SlaQCoYkZIv0frV1V1lI9eE3g-1bfqobH1UWx0G75qPyFj_7YyuosJVute9a5uomFeVztvBn6OTUlfBXuzmCr3f371tHuPty8PTZr2NDRW0j4HRLBWlzUopc4MxFoRLTC0BoYGmTAAwrjlOdWZ1qQlhmSVc5DzPpOAG6Apdz72db78GG3pVu2BsVenGtkNQXDA5PkxHkMyg8W0I3paq867W_kcBVpM4NXlRkxdFuAI1ihtDV7v2Ia9t8RfZmRqBmxlwbbffHhaprihHNj5k_zn-C90lgpI</recordid><startdate>20050201</startdate><enddate>20050201</enddate><creator>Letić, Milorad</creator><general>IOP Publishing</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20050201</creationdate><title>Simple instrument for measuring cervical dilatation during labour</title><author>Letić, Milorad</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c373t-143957fe9f88bc000726803e217a135471146a605a9eafa2249e267b6b9876c13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Adult</topic><topic>Disposable Equipment</topic><topic>Equipment Design</topic><topic>Female</topic><topic>Humans</topic><topic>Labor Stage, First</topic><topic>Obstetrics - instrumentation</topic><topic>Pregnancy</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Letić, Milorad</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physiological measurement</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Letić, Milorad</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simple instrument for measuring cervical dilatation during labour</atitle><jtitle>Physiological measurement</jtitle><addtitle>Physiol Meas</addtitle><date>2005-02-01</date><risdate>2005</risdate><volume>26</volume><issue>1</issue><spage>N1</spage><epage>N7</epage><pages>N1-N7</pages><issn>0967-3334</issn><eissn>1361-6579</eissn><abstract>The construction of a simple disposable instrument for the measurement of cervical dilatation is described. The instrument consists of two clips, a measuring tape and a flexible tube. The measuring tape is fixed to one clip and threaded through the flexible tube, which is fixed to the other clip. The clips are attached to opposing cervical rims at 3 o'clock and 9 o'clock and the differential displacement of the marking on the measuring tape and free end of the flexible tube is measured. Laboratory measurements were performed in order to determine the error of measurement. The absolute error of measurement with this instrument is 1.5 mm. Clinical measurements were performed on 12 parturients with a single foetus in vertex position and 3 to 4 cm cervical dilatation. The results of measurements were within +/-1 cm error margin of manual assessments. No adverse effects were noted due to the use of the instrument. The instrument did cause minor discomfort to patients during application.</abstract><cop>England</cop><pub>IOP Publishing</pub><pmid>15742886</pmid><doi>10.1088/0967-3334/26/1/N01</doi></addata></record>
fulltext fulltext
identifier ISSN: 0967-3334
ispartof Physiological measurement, 2005-02, Vol.26 (1), p.N1-N7
issn 0967-3334
1361-6579
language eng
recordid cdi_pubmed_primary_15742886
source MEDLINE; IOP Publishing Journals; Institute of Physics (IOP) Journals - HEAL-Link
subjects Adult
Disposable Equipment
Equipment Design
Female
Humans
Labor Stage, First
Obstetrics - instrumentation
Pregnancy
Sensitivity and Specificity
title Simple instrument for measuring cervical dilatation during labour
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T20%3A30%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simple%20instrument%20for%20measuring%20cervical%20dilatation%20during%20labour&rft.jtitle=Physiological%20measurement&rft.au=Leti%C4%87,%20Milorad&rft.date=2005-02-01&rft.volume=26&rft.issue=1&rft.spage=N1&rft.epage=N7&rft.pages=N1-N7&rft.issn=0967-3334&rft.eissn=1361-6579&rft_id=info:doi/10.1088/0967-3334/26/1/N01&rft_dat=%3Cproquest_pubme%3E67480963%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=67480963&rft_id=info:pmid/15742886&rfr_iscdi=true