Emission of air pollutants in removal of bone cement with ultrasound instruments in revision endoprosthetics
The use of ultrasonic instruments to remove PMMA bone cement during revision hip arthroplasty results in the production of fumes. These emissions were analysed under standardized laboratory conditions, when it was found that the MMA concentration measured was only 1/10th of the MAC value. In terms o...
Gespeichert in:
Veröffentlicht in: | Biomedizinische Technik 2001-10, Vol.46 (10), p.287 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | ger |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Schreiben Sie den ersten Kommentar!