Stability of wind turbine foundations - accounting for gapping and eccentric loading
An additional consideration to be given attention is the different load cases that apply to wind turbine structures. Load combinations in turbine design apply to the IEC 61400-1 (2005) which stipulates load scenarios that require consideration in all the crucial operating conditions of the turbine,...
Gespeichert in:
Veröffentlicht in: | Civil Engineering : Magazine of the South African Institution of Civil Engineering 2016-04, Vol.24 (3), p.63 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 3 |
container_start_page | 63 |
container_title | Civil Engineering : Magazine of the South African Institution of Civil Engineering |
container_volume | 24 |
creator | Mawer, Byron Kalumba, Denis |
description | An additional consideration to be given attention is the different load cases that apply to wind turbine structures. Load combinations in turbine design apply to the IEC 61400-1 (2005) which stipulates load scenarios that require consideration in all the crucial operating conditions of the turbine, i.e. parked, start-up, normal operation, abnormal operation, shut down, etc. |
format | Article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_reports_1790506654</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>4064732131</sourcerecordid><originalsourceid>FETCH-proquest_reports_17905066543</originalsourceid><addsrcrecordid>eNqNi80KwjAQhHNQsP68w-K9sKm2xbMo3u29pGlaVkoSky3i2xvBB_A0M9_MLEQmsZB5gYgrsY7xgSiLUtaZaO6sOpqI3-AGeJHtgefQkTUwuNn2isnZCDkorVNmsmMqAozK-69X6WC0NpYDaZic6hPdiuWgpmh2P92I_fXSnG-5D-45m8htMN4Fjq2sT1hiVZXHw1-jD44IP0I</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1790506654</pqid></control><display><type>article</type><title>Stability of wind turbine foundations - accounting for gapping and eccentric loading</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Business Source Complete</source><source>Sabinet African Journals Core Collection</source><creator>Mawer, Byron ; Kalumba, Denis</creator><creatorcontrib>Mawer, Byron ; Kalumba, Denis</creatorcontrib><description>An additional consideration to be given attention is the different load cases that apply to wind turbine structures. Load combinations in turbine design apply to the IEC 61400-1 (2005) which stipulates load scenarios that require consideration in all the crucial operating conditions of the turbine, i.e. parked, start-up, normal operation, abnormal operation, shut down, etc.</description><identifier>ISSN: 1021-2000</identifier><identifier>CODEN: CIVNEO</identifier><language>eng</language><publisher>Yeoville: The South African Institution of Civil Engineers</publisher><subject>Air flow ; Civil engineering ; Design ; Energy ; Energy industry ; Load ; Turbines ; Wind power</subject><ispartof>Civil Engineering : Magazine of the South African Institution of Civil Engineering, 2016-04, Vol.24 (3), p.63</ispartof><rights>Copyright The South African Institution of Civil Engineers Apr 2016</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>312,780,784,791</link.rule.ids></links><search><creatorcontrib>Mawer, Byron</creatorcontrib><creatorcontrib>Kalumba, Denis</creatorcontrib><title>Stability of wind turbine foundations - accounting for gapping and eccentric loading</title><title>Civil Engineering : Magazine of the South African Institution of Civil Engineering</title><description>An additional consideration to be given attention is the different load cases that apply to wind turbine structures. Load combinations in turbine design apply to the IEC 61400-1 (2005) which stipulates load scenarios that require consideration in all the crucial operating conditions of the turbine, i.e. parked, start-up, normal operation, abnormal operation, shut down, etc.</description><subject>Air flow</subject><subject>Civil engineering</subject><subject>Design</subject><subject>Energy</subject><subject>Energy industry</subject><subject>Load</subject><subject>Turbines</subject><subject>Wind power</subject><issn>1021-2000</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><sourceid>8G5</sourceid><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><sourceid>GUQSH</sourceid><sourceid>M2O</sourceid><recordid>eNqNi80KwjAQhHNQsP68w-K9sKm2xbMo3u29pGlaVkoSky3i2xvBB_A0M9_MLEQmsZB5gYgrsY7xgSiLUtaZaO6sOpqI3-AGeJHtgefQkTUwuNn2isnZCDkorVNmsmMqAozK-69X6WC0NpYDaZic6hPdiuWgpmh2P92I_fXSnG-5D-45m8htMN4Fjq2sT1hiVZXHw1-jD44IP0I</recordid><startdate>20160401</startdate><enddate>20160401</enddate><creator>Mawer, Byron</creator><creator>Kalumba, Denis</creator><general>The South African Institution of Civil Engineers</general><scope>3V.</scope><scope>7QH</scope><scope>7UA</scope><scope>7WY</scope><scope>7XB</scope><scope>883</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FK</scope><scope>8FL</scope><scope>8G5</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BEZIV</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>BKSAR</scope><scope>C1K</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>F1W</scope><scope>FR3</scope><scope>FRNLG</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>H96</scope><scope>HCIFZ</scope><scope>K60</scope><scope>K6~</scope><scope>KR7</scope><scope>L.-</scope><scope>L.G</scope><scope>L6V</scope><scope>M0F</scope><scope>M2O</scope><scope>M7S</scope><scope>MBDVC</scope><scope>PADUT</scope><scope>PCBAR</scope><scope>PQBIZ</scope><scope>PQBZA</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope><scope>PYYUZ</scope><scope>Q9U</scope><scope>S0X</scope></search><sort><creationdate>20160401</creationdate><title>Stability of wind turbine foundations - accounting for gapping and eccentric loading</title><author>Mawer, Byron ; Kalumba, Denis</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_reports_17905066543</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Air flow</topic><topic>Civil engineering</topic><topic>Design</topic><topic>Energy</topic><topic>Energy industry</topic><topic>Load</topic><topic>Turbines</topic><topic>Wind power</topic><toplevel>online_resources</toplevel><creatorcontrib>Mawer, Byron</creatorcontrib><creatorcontrib>Kalumba, Denis</creatorcontrib><collection>ProQuest Central (Corporate)</collection><collection>Aqualine</collection><collection>Water Resources Abstracts</collection><collection>ABI/INFORM Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ABI/INFORM Trade & Industry (Alumni Edition)</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ABI/INFORM Collection (Alumni Edition)</collection><collection>Research Library (Alumni Edition)</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Business Premium Collection</collection><collection>Technology Collection</collection><collection>Natural Science Collection</collection><collection>Earth, Atmospheric & Aquatic Science Collection</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Engineering Research Database</collection><collection>Business Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) 2: Ocean Technology, Policy & Non-Living Resources</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Business Collection (Alumni Edition)</collection><collection>ProQuest Business Collection</collection><collection>Civil Engineering Abstracts</collection><collection>ABI/INFORM Professional Advanced</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) Professional</collection><collection>ProQuest Engineering Collection</collection><collection>ABI/INFORM Trade & Industry</collection><collection>Research Library</collection><collection>Engineering Database</collection><collection>Research Library (Corporate)</collection><collection>Research Library China</collection><collection>Earth, Atmospheric & Aquatic Science Database</collection><collection>ProQuest One Business</collection><collection>ProQuest One Business (Alumni)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><collection>ABI/INFORM Collection China</collection><collection>ProQuest Central Basic</collection><collection>SIRS Editorial</collection><jtitle>Civil Engineering : Magazine of the South African Institution of Civil Engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mawer, Byron</au><au>Kalumba, Denis</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Stability of wind turbine foundations - accounting for gapping and eccentric loading</atitle><jtitle>Civil Engineering : Magazine of the South African Institution of Civil Engineering</jtitle><date>2016-04-01</date><risdate>2016</risdate><volume>24</volume><issue>3</issue><spage>63</spage><pages>63-</pages><issn>1021-2000</issn><coden>CIVNEO</coden><abstract>An additional consideration to be given attention is the different load cases that apply to wind turbine structures. Load combinations in turbine design apply to the IEC 61400-1 (2005) which stipulates load scenarios that require consideration in all the crucial operating conditions of the turbine, i.e. parked, start-up, normal operation, abnormal operation, shut down, etc.</abstract><cop>Yeoville</cop><pub>The South African Institution of Civil Engineers</pub></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1021-2000 |
ispartof | Civil Engineering : Magazine of the South African Institution of Civil Engineering, 2016-04, Vol.24 (3), p.63 |
issn | 1021-2000 |
language | eng |
recordid | cdi_proquest_reports_1790506654 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Business Source Complete; Sabinet African Journals Core Collection |
subjects | Air flow Civil engineering Design Energy Energy industry Load Turbines Wind power |
title | Stability of wind turbine foundations - accounting for gapping and eccentric loading |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T12%3A54%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Stability%20of%20wind%20turbine%20foundations%20-%20accounting%20for%20gapping%20and%20eccentric%20loading&rft.jtitle=Civil%20Engineering%20:%20Magazine%20of%20the%20South%20African%20Institution%20of%20Civil%20Engineering&rft.au=Mawer,%20Byron&rft.date=2016-04-01&rft.volume=24&rft.issue=3&rft.spage=63&rft.pages=63-&rft.issn=1021-2000&rft.coden=CIVNEO&rft_id=info:doi/&rft_dat=%3Cproquest%3E4064732131%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1790506654&rft_id=info:pmid/&rfr_iscdi=true |