How punctal occlusion improves multifocal IOL satisfaction

[...]the K-values changed from 42.61/43.27 @ 41° to 42.88/43.72 @ 53° (a difference in average ? of 0.36 D and in axis of 12°) and 0.8 D increase in average pupil power. Had we based the surgical plan on initial data without the benefit of punctal occlusion, the patient would likely have ended up wi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ophthalmology Times 2013-05, Vol.38 (9), p.20
Hauptverfasser: McCabe, Craig F, McCabe, Shannon E
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[...]the K-values changed from 42.61/43.27 @ 41° to 42.88/43.72 @ 53° (a difference in average ? of 0.36 D and in axis of 12°) and 0.8 D increase in average pupil power. Had we based the surgical plan on initial data without the benefit of punctal occlusion, the patient would likely have ended up with a manifest refraction of -0.75 + 0.75 x 045 at best. [...]preoperative treatment can mean the difference between needing to perform an enhancement procedure on an unsatisfied patient and having a very satisfied patient with a premium lens.
ISSN:0193-032X