Reversed phase liquid chromatography method with fluorescence detection of gemifloxacin in rat plasma and its application to the pharmacokinetic study

A simple, accurate and precise high-performance liquid chromatographic method with fluorescence detection was developed and validated for the determination of gemifloxacin (GEM) in rat plasma using furosemide as internal standard (I.S.). Plasma samples were pretreated by direct deproteinization and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of chromatography. B, Analytical technologies in the biomedical and life sciences Analytical technologies in the biomedical and life sciences, 2011-11, Vol.879 (30), p.3639-3644
Hauptverfasser: Kaiser, Moacir, Grünspan, Lauren D., Costa, Teresa Dalla, Tasso, Leandro
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A simple, accurate and precise high-performance liquid chromatographic method with fluorescence detection was developed and validated for the determination of gemifloxacin (GEM) in rat plasma using furosemide as internal standard (I.S.). Plasma samples were pretreated by direct deproteinization and all samples and standard solutions were chromatographed at 45 °C using triethylamine solution (0.5%, v/v, pH 3.0 ± 0.1), methanol and acetonitrile (63:30:7, v/v/v) as the mobile phase. Chromatographic resolution was achieved using a RP-C 18 column (Atlantis, Waters, 150 mm × 4.6 mm, 5 μm) at a flow rate of 1.0 mL min −1 and an injection volume of 30 μL. The analytes were measured by fluorescence detection with excitation and emission wavelengths of 344 nm and 399 nm, respectively. The retention times for GEM and I.S. were approximately 7.5 and 12.6 min, respectively. The lower limit of quantitation (LLOQ) was 20 ng mL −1 and the calibration curves were linear over a concentration range of 20–5000 ng mL −1. The intra- and inter-day precisions, expressed by relative standard deviation (R.S.D.) were lower than 6.24% and 4.49%, respectively. The accuracy ranged from 91.3% to 112% and from 98.8% to 106% for the lower and upper limit of quantitation of the calibration curve, respectively. Ratio of peak area of analyte to I.S. was used for quantification of plasma samples. No interferences from endogenous substances were found. The recovery of GEM and I.S. from plasma was greater than 90%. Drug stability in plasma was shown at room temperature for 4 h, after three freeze–thaw cycles for 24 h, in freezer at −80 °C for 60 days, and in the autosampler after processing for 12 h. The utility of the assay was confirmed by the successful analysis of plasma samples from GEM pharmacokinetics studies in the rats after intravenous administration.
ISSN:1570-0232
1873-376X
DOI:10.1016/j.jchromb.2011.09.011