Evaluation of the Red Emitting rm Gd 2 rm O 2 rm S : rm Eu Powder Scintillator for Use in Indirect X-Ray Digital Mammography Detectors

The aim of the present study was to investigate the imaging transfer characteristics and the luminescence efficiency (XLE) of rm Gd 2 rm O 2 rm S : rm Eu powder scintillator for use in X-ray mammography detectors. rm Gd 2 rm O 2 rm S : rm Eu emits in the red part of the visible spectrum, having very...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 2011-10, Vol.58 (5), p.2503-2511
Hauptverfasser: Michail, Christos M, Fountos, George P, Valais, Ioannis G, Kalyvas, Nektarios I, Liaparinos, Panagiotis F, Kandarakis, Ioannis S, Panayiotakis, George S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 2511
container_issue 5
container_start_page 2503
container_title IEEE transactions on nuclear science
container_volume 58
creator Michail, Christos M
Fountos, George P
Valais, Ioannis G
Kalyvas, Nektarios I
Liaparinos, Panagiotis F
Kandarakis, Ioannis S
Panayiotakis, George S
description The aim of the present study was to investigate the imaging transfer characteristics and the luminescence efficiency (XLE) of rm Gd 2 rm O 2 rm S : rm Eu powder scintillator for use in X-ray mammography detectors. rm Gd 2 rm O 2 rm S : rm Eu emits in the red part of the visible spectrum, having very good spectral compatibility with optical sensors employed in digital imaging systems. Three rm Gd 2 rm O 2 rm S : rm Eu powder scintillating screens, with coating thicknesses 33.1, 46.4 and 63.1 rm mg / cm 2 , were prepared in our laboratory. The imaging performance of these screens was assessed by experimental determination of the modulation transfer function (MTF), the noise transfer function (NTF) and the detective quantum efficiency (DQE) as well as a single index image quality parameter such as the information capacity (IC). A theoretical model, describing radiation and light transfer, was used to fit experimental MTF data. This has allowed the estimation of optical attenuation coefficients of the scintillator. In addition, a previously validated Monte Carlo code, based on the X-ray attenuation properties and on the Mie light scattering theory, was used to estimate the X-ray detection efficiency, the Swank factor and the zero frequency DQE of the rm Gd 2 rm O 2 rm S : rm Eu scintillator. Results showed that rm Gd 2 rm O 2 rm S : rm Eu exhibits high MTF and DQE values, which are comparable to those of a commercially employed rm Gd 2 rm O 2 rm S : rm Tb screen. In addition rm Gd 2 rm O 2 rm S : rm Eu shows high compatibility (effective gain) to CCDs and to recently introduced CMOS based detectors. Considering our image quality parameters and luminescence efficiency results, this material can potentially be considered for use in digital X-ray mammography detectors.
doi_str_mv 10.1109/TNS.2011.2162002
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_963849121</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>963849121</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_9638491213</originalsourceid><addsrcrecordid>eNqNjctOwzAURC0EEuGxZ3l3rBJ83bjEbCEUFjzUFIldZSVOauTYxXZA_ADfjSv4ABajoxkdaQg5Q1ogUnGxemwKRhELhnNGKdsjGXJe5cgvq32SUYpVLkohDslRCG-plpzyjHzXH9JMMmpnwfUQNwqWqoN61DFqO4AfYdEB2_HpFw1c7VBP8Ow-O-WhabWN2hgZnYc-5SUo0Bbubae9aiO85kv5BTd60FEaeJDj6AYvt5u0qZgE58MJOeilCer0j8fk_LZeXd_lW-_eJxXietShVenEKjeFtZjPqlIgw9n_zR-tfVnG</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>963849121</pqid></control><display><type>article</type><title>Evaluation of the Red Emitting rm Gd 2 rm O 2 rm S : rm Eu Powder Scintillator for Use in Indirect X-Ray Digital Mammography Detectors</title><source>IEEE Electronic Library (IEL)</source><creator>Michail, Christos M ; Fountos, George P ; Valais, Ioannis G ; Kalyvas, Nektarios I ; Liaparinos, Panagiotis F ; Kandarakis, Ioannis S ; Panayiotakis, George S</creator><creatorcontrib>Michail, Christos M ; Fountos, George P ; Valais, Ioannis G ; Kalyvas, Nektarios I ; Liaparinos, Panagiotis F ; Kandarakis, Ioannis S ; Panayiotakis, George S</creatorcontrib><description>The aim of the present study was to investigate the imaging transfer characteristics and the luminescence efficiency (XLE) of rm Gd 2 rm O 2 rm S : rm Eu powder scintillator for use in X-ray mammography detectors. rm Gd 2 rm O 2 rm S : rm Eu emits in the red part of the visible spectrum, having very good spectral compatibility with optical sensors employed in digital imaging systems. Three rm Gd 2 rm O 2 rm S : rm Eu powder scintillating screens, with coating thicknesses 33.1, 46.4 and 63.1 rm mg / cm 2 , were prepared in our laboratory. The imaging performance of these screens was assessed by experimental determination of the modulation transfer function (MTF), the noise transfer function (NTF) and the detective quantum efficiency (DQE) as well as a single index image quality parameter such as the information capacity (IC). A theoretical model, describing radiation and light transfer, was used to fit experimental MTF data. This has allowed the estimation of optical attenuation coefficients of the scintillator. In addition, a previously validated Monte Carlo code, based on the X-ray attenuation properties and on the Mie light scattering theory, was used to estimate the X-ray detection efficiency, the Swank factor and the zero frequency DQE of the rm Gd 2 rm O 2 rm S : rm Eu scintillator. Results showed that rm Gd 2 rm O 2 rm S : rm Eu exhibits high MTF and DQE values, which are comparable to those of a commercially employed rm Gd 2 rm O 2 rm S : rm Tb screen. In addition rm Gd 2 rm O 2 rm S : rm Eu shows high compatibility (effective gain) to CCDs and to recently introduced CMOS based detectors. Considering our image quality parameters and luminescence efficiency results, this material can potentially be considered for use in digital X-ray mammography detectors.</description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/TNS.2011.2162002</identifier><language>eng</language><subject>Detectors ; Imaging ; Mathematical models ; Monte Carlo methods ; Optical communication ; Optical transfer function ; Screens ; X-rays</subject><ispartof>IEEE transactions on nuclear science, 2011-10, Vol.58 (5), p.2503-2511</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Michail, Christos M</creatorcontrib><creatorcontrib>Fountos, George P</creatorcontrib><creatorcontrib>Valais, Ioannis G</creatorcontrib><creatorcontrib>Kalyvas, Nektarios I</creatorcontrib><creatorcontrib>Liaparinos, Panagiotis F</creatorcontrib><creatorcontrib>Kandarakis, Ioannis S</creatorcontrib><creatorcontrib>Panayiotakis, George S</creatorcontrib><title>Evaluation of the Red Emitting rm Gd 2 rm O 2 rm S : rm Eu Powder Scintillator for Use in Indirect X-Ray Digital Mammography Detectors</title><title>IEEE transactions on nuclear science</title><description>The aim of the present study was to investigate the imaging transfer characteristics and the luminescence efficiency (XLE) of rm Gd 2 rm O 2 rm S : rm Eu powder scintillator for use in X-ray mammography detectors. rm Gd 2 rm O 2 rm S : rm Eu emits in the red part of the visible spectrum, having very good spectral compatibility with optical sensors employed in digital imaging systems. Three rm Gd 2 rm O 2 rm S : rm Eu powder scintillating screens, with coating thicknesses 33.1, 46.4 and 63.1 rm mg / cm 2 , were prepared in our laboratory. The imaging performance of these screens was assessed by experimental determination of the modulation transfer function (MTF), the noise transfer function (NTF) and the detective quantum efficiency (DQE) as well as a single index image quality parameter such as the information capacity (IC). A theoretical model, describing radiation and light transfer, was used to fit experimental MTF data. This has allowed the estimation of optical attenuation coefficients of the scintillator. In addition, a previously validated Monte Carlo code, based on the X-ray attenuation properties and on the Mie light scattering theory, was used to estimate the X-ray detection efficiency, the Swank factor and the zero frequency DQE of the rm Gd 2 rm O 2 rm S : rm Eu scintillator. Results showed that rm Gd 2 rm O 2 rm S : rm Eu exhibits high MTF and DQE values, which are comparable to those of a commercially employed rm Gd 2 rm O 2 rm S : rm Tb screen. In addition rm Gd 2 rm O 2 rm S : rm Eu shows high compatibility (effective gain) to CCDs and to recently introduced CMOS based detectors. Considering our image quality parameters and luminescence efficiency results, this material can potentially be considered for use in digital X-ray mammography detectors.</description><subject>Detectors</subject><subject>Imaging</subject><subject>Mathematical models</subject><subject>Monte Carlo methods</subject><subject>Optical communication</subject><subject>Optical transfer function</subject><subject>Screens</subject><subject>X-rays</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNqNjctOwzAURC0EEuGxZ3l3rBJ83bjEbCEUFjzUFIldZSVOauTYxXZA_ADfjSv4ABajoxkdaQg5Q1ogUnGxemwKRhELhnNGKdsjGXJe5cgvq32SUYpVLkohDslRCG-plpzyjHzXH9JMMmpnwfUQNwqWqoN61DFqO4AfYdEB2_HpFw1c7VBP8Ow-O-WhabWN2hgZnYc-5SUo0Bbubae9aiO85kv5BTd60FEaeJDj6AYvt5u0qZgE58MJOeilCer0j8fk_LZeXd_lW-_eJxXietShVenEKjeFtZjPqlIgw9n_zR-tfVnG</recordid><startdate>20111001</startdate><enddate>20111001</enddate><creator>Michail, Christos M</creator><creator>Fountos, George P</creator><creator>Valais, Ioannis G</creator><creator>Kalyvas, Nektarios I</creator><creator>Liaparinos, Panagiotis F</creator><creator>Kandarakis, Ioannis S</creator><creator>Panayiotakis, George S</creator><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>F28</scope><scope>FR3</scope><scope>KR7</scope><scope>L7M</scope></search><sort><creationdate>20111001</creationdate><title>Evaluation of the Red Emitting rm Gd 2 rm O 2 rm S : rm Eu Powder Scintillator for Use in Indirect X-Ray Digital Mammography Detectors</title><author>Michail, Christos M ; Fountos, George P ; Valais, Ioannis G ; Kalyvas, Nektarios I ; Liaparinos, Panagiotis F ; Kandarakis, Ioannis S ; Panayiotakis, George S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_9638491213</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Detectors</topic><topic>Imaging</topic><topic>Mathematical models</topic><topic>Monte Carlo methods</topic><topic>Optical communication</topic><topic>Optical transfer function</topic><topic>Screens</topic><topic>X-rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Michail, Christos M</creatorcontrib><creatorcontrib>Fountos, George P</creatorcontrib><creatorcontrib>Valais, Ioannis G</creatorcontrib><creatorcontrib>Kalyvas, Nektarios I</creatorcontrib><creatorcontrib>Liaparinos, Panagiotis F</creatorcontrib><creatorcontrib>Kandarakis, Ioannis S</creatorcontrib><creatorcontrib>Panayiotakis, George S</creatorcontrib><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Michail, Christos M</au><au>Fountos, George P</au><au>Valais, Ioannis G</au><au>Kalyvas, Nektarios I</au><au>Liaparinos, Panagiotis F</au><au>Kandarakis, Ioannis S</au><au>Panayiotakis, George S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of the Red Emitting rm Gd 2 rm O 2 rm S : rm Eu Powder Scintillator for Use in Indirect X-Ray Digital Mammography Detectors</atitle><jtitle>IEEE transactions on nuclear science</jtitle><date>2011-10-01</date><risdate>2011</risdate><volume>58</volume><issue>5</issue><spage>2503</spage><epage>2511</epage><pages>2503-2511</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><abstract>The aim of the present study was to investigate the imaging transfer characteristics and the luminescence efficiency (XLE) of rm Gd 2 rm O 2 rm S : rm Eu powder scintillator for use in X-ray mammography detectors. rm Gd 2 rm O 2 rm S : rm Eu emits in the red part of the visible spectrum, having very good spectral compatibility with optical sensors employed in digital imaging systems. Three rm Gd 2 rm O 2 rm S : rm Eu powder scintillating screens, with coating thicknesses 33.1, 46.4 and 63.1 rm mg / cm 2 , were prepared in our laboratory. The imaging performance of these screens was assessed by experimental determination of the modulation transfer function (MTF), the noise transfer function (NTF) and the detective quantum efficiency (DQE) as well as a single index image quality parameter such as the information capacity (IC). A theoretical model, describing radiation and light transfer, was used to fit experimental MTF data. This has allowed the estimation of optical attenuation coefficients of the scintillator. In addition, a previously validated Monte Carlo code, based on the X-ray attenuation properties and on the Mie light scattering theory, was used to estimate the X-ray detection efficiency, the Swank factor and the zero frequency DQE of the rm Gd 2 rm O 2 rm S : rm Eu scintillator. Results showed that rm Gd 2 rm O 2 rm S : rm Eu exhibits high MTF and DQE values, which are comparable to those of a commercially employed rm Gd 2 rm O 2 rm S : rm Tb screen. In addition rm Gd 2 rm O 2 rm S : rm Eu shows high compatibility (effective gain) to CCDs and to recently introduced CMOS based detectors. Considering our image quality parameters and luminescence efficiency results, this material can potentially be considered for use in digital X-ray mammography detectors.</abstract><doi>10.1109/TNS.2011.2162002</doi></addata></record>
fulltext fulltext
identifier ISSN: 0018-9499
ispartof IEEE transactions on nuclear science, 2011-10, Vol.58 (5), p.2503-2511
issn 0018-9499
1558-1578
language eng
recordid cdi_proquest_miscellaneous_963849121
source IEEE Electronic Library (IEL)
subjects Detectors
Imaging
Mathematical models
Monte Carlo methods
Optical communication
Optical transfer function
Screens
X-rays
title Evaluation of the Red Emitting rm Gd 2 rm O 2 rm S : rm Eu Powder Scintillator for Use in Indirect X-Ray Digital Mammography Detectors
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T16%3A17%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20the%20Red%20Emitting%20rm%20Gd%202%20rm%20O%202%20rm%20S%20:%20rm%20Eu%20Powder%20Scintillator%20for%20Use%20in%20Indirect%20X-Ray%20Digital%20Mammography%20Detectors&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=Michail,%20Christos%20M&rft.date=2011-10-01&rft.volume=58&rft.issue=5&rft.spage=2503&rft.epage=2511&rft.pages=2503-2511&rft.issn=0018-9499&rft.eissn=1558-1578&rft_id=info:doi/10.1109/TNS.2011.2162002&rft_dat=%3Cproquest%3E963849121%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=963849121&rft_id=info:pmid/&rfr_iscdi=true