Invited Article: A materials investigation of a phase-change micro-valve for greenhouse gas collection and other potential applications

The deleterious consequences of climate change are well documented. Future climate treaties might mandate greenhouse gas (GHG) emissions measurement from signatories in order to verify compliance. The acquisition of atmospheric chemistry would benefit from low cost, small size/weight/power of micros...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 2012-03, Vol.83 (3), p.031301-031301-11
Hauptverfasser: Manginell, Ronald P., Moorman, Matthew W., Rejent, Jerome A., Vianco, Paul T., Grazier, Mark J., Wroblewski, Brian D., Mowry, Curtis D., Achyuthan, Komandoor E.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 031301-11
container_issue 3
container_start_page 031301
container_title Review of scientific instruments
container_volume 83
creator Manginell, Ronald P.
Moorman, Matthew W.
Rejent, Jerome A.
Vianco, Paul T.
Grazier, Mark J.
Wroblewski, Brian D.
Mowry, Curtis D.
Achyuthan, Komandoor E.
description The deleterious consequences of climate change are well documented. Future climate treaties might mandate greenhouse gas (GHG) emissions measurement from signatories in order to verify compliance. The acquisition of atmospheric chemistry would benefit from low cost, small size/weight/power of microsystems. In this paper, we investigated several key materials science aspects of a phase-change microvalve (PCμV) technology with low power/size/weight/cost for ubiquitous GHG sampling. The novel design, based on phase-change material low-melting-point eutectic metal alloys (indium-bismuth, InBi and tin-lead, SnPb), could be actuated at temperatures as low as 72 °C. Valve manufacturing was based on standard thick and thin-film processes and solder technologies that are commonly used in industry, enabling low-cost, high-volume fabrication. Aging studies showed that it was feasible to batch fabricate the PCμVs and store them for future use, especially in the case of SnPb alloys. Hermetic sealing of the valve prototypes was demonstrated through helium leak testing, and Mil spec leak rates less than 1 × 10 −9 atm cm 3 /s were achieved. This confirms that the sample capture and analysis interval can be greatly expanded, easing the logistical burdens of ubiquitous GHG monitoring. Highly conservative and hypothetical CO 2 bias due to valve actuation at altitude in 1 cm 3 microsamplers would be significantly below 1.0 and 2.2 ppmv for heat-treated InBi and SnPb solders, respectively. The CO 2 bias from the PCμV scales well, as a doubling of sampler volume halved the bias. We estimated the shelf life of the SnPb PCμVs to be at least 2.8 years. These efforts will enable the development of low cost, low dead volume, small size/weight microsystems for monitoring GHGs and volatile organic compounds.
doi_str_mv 10.1063/1.3688856
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_963831520</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>963831520</sourcerecordid><originalsourceid>FETCH-LOGICAL-c404t-30149db1531970bedc3ada9fd7ac1e5ff113cd8e649304bc0519411a0b3fae993</originalsourceid><addsrcrecordid>eNp1kc1u1DAURi1URKeFBS-AvKtYpPWNnUyM1MWooj9SJTawtm6cmxmjJA62ZySegNfGzITu6o035x77-y5jH0Fcg6jlDVzLummaqn7DViAaXazrUp6xlRBSFfVaNefsIsafIp8K4B07L0tVl43WK_bnaTq4RB3fhOTsQF_4ho-YKDgcInfTgWJyW0zOT9z3HPm8w0iF3eG0JT46G3xxwOFAvPeBbwPRtPP7SHyLkVs_DGSPszh13KcdBT77RFPKeo7zPDh7dMf37G2fX6QPy33Jftx__X73WDx_e3i62zwXVgmVCilA6a6FSoJei5Y6K7FD3XdrtEBV3wNI2zVUKy2Fam3OqxUAilb2SFrLS3Z18s7B_9rncGZ00dIw4ET530bXspFQlSKTn09kjhhjoN7MwY0YfhsQ5l_tBsxSe2Y_LdZ9O1L3Qv7vOQO3JyBal46JX7ctGzHLRszGjPIvyAmUPw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>963831520</pqid></control><display><type>article</type><title>Invited Article: A materials investigation of a phase-change micro-valve for greenhouse gas collection and other potential applications</title><source>AIP Journals Complete</source><source>AIP Digital Archive</source><source>Alma/SFX Local Collection</source><creator>Manginell, Ronald P. ; Moorman, Matthew W. ; Rejent, Jerome A. ; Vianco, Paul T. ; Grazier, Mark J. ; Wroblewski, Brian D. ; Mowry, Curtis D. ; Achyuthan, Komandoor E.</creator><creatorcontrib>Manginell, Ronald P. ; Moorman, Matthew W. ; Rejent, Jerome A. ; Vianco, Paul T. ; Grazier, Mark J. ; Wroblewski, Brian D. ; Mowry, Curtis D. ; Achyuthan, Komandoor E.</creatorcontrib><description>The deleterious consequences of climate change are well documented. Future climate treaties might mandate greenhouse gas (GHG) emissions measurement from signatories in order to verify compliance. The acquisition of atmospheric chemistry would benefit from low cost, small size/weight/power of microsystems. In this paper, we investigated several key materials science aspects of a phase-change microvalve (PCμV) technology with low power/size/weight/cost for ubiquitous GHG sampling. The novel design, based on phase-change material low-melting-point eutectic metal alloys (indium-bismuth, InBi and tin-lead, SnPb), could be actuated at temperatures as low as 72 °C. Valve manufacturing was based on standard thick and thin-film processes and solder technologies that are commonly used in industry, enabling low-cost, high-volume fabrication. Aging studies showed that it was feasible to batch fabricate the PCμVs and store them for future use, especially in the case of SnPb alloys. Hermetic sealing of the valve prototypes was demonstrated through helium leak testing, and Mil spec leak rates less than 1 × 10 −9 atm cm 3 /s were achieved. This confirms that the sample capture and analysis interval can be greatly expanded, easing the logistical burdens of ubiquitous GHG monitoring. Highly conservative and hypothetical CO 2 bias due to valve actuation at altitude in 1 cm 3 microsamplers would be significantly below 1.0 and 2.2 ppmv for heat-treated InBi and SnPb solders, respectively. The CO 2 bias from the PCμV scales well, as a doubling of sampler volume halved the bias. We estimated the shelf life of the SnPb PCμVs to be at least 2.8 years. These efforts will enable the development of low cost, low dead volume, small size/weight microsystems for monitoring GHGs and volatile organic compounds.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.3688856</identifier><identifier>PMID: 22462899</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States: American Institute of Physics</publisher><ispartof>Review of scientific instruments, 2012-03, Vol.83 (3), p.031301-031301-11</ispartof><rights>2012 American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c404t-30149db1531970bedc3ada9fd7ac1e5ff113cd8e649304bc0519411a0b3fae993</citedby><cites>FETCH-LOGICAL-c404t-30149db1531970bedc3ada9fd7ac1e5ff113cd8e649304bc0519411a0b3fae993</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.3688856$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,776,780,790,1553,4498,27901,27902,76126,76132</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22462899$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Manginell, Ronald P.</creatorcontrib><creatorcontrib>Moorman, Matthew W.</creatorcontrib><creatorcontrib>Rejent, Jerome A.</creatorcontrib><creatorcontrib>Vianco, Paul T.</creatorcontrib><creatorcontrib>Grazier, Mark J.</creatorcontrib><creatorcontrib>Wroblewski, Brian D.</creatorcontrib><creatorcontrib>Mowry, Curtis D.</creatorcontrib><creatorcontrib>Achyuthan, Komandoor E.</creatorcontrib><title>Invited Article: A materials investigation of a phase-change micro-valve for greenhouse gas collection and other potential applications</title><title>Review of scientific instruments</title><addtitle>Rev Sci Instrum</addtitle><description>The deleterious consequences of climate change are well documented. Future climate treaties might mandate greenhouse gas (GHG) emissions measurement from signatories in order to verify compliance. The acquisition of atmospheric chemistry would benefit from low cost, small size/weight/power of microsystems. In this paper, we investigated several key materials science aspects of a phase-change microvalve (PCμV) technology with low power/size/weight/cost for ubiquitous GHG sampling. The novel design, based on phase-change material low-melting-point eutectic metal alloys (indium-bismuth, InBi and tin-lead, SnPb), could be actuated at temperatures as low as 72 °C. Valve manufacturing was based on standard thick and thin-film processes and solder technologies that are commonly used in industry, enabling low-cost, high-volume fabrication. Aging studies showed that it was feasible to batch fabricate the PCμVs and store them for future use, especially in the case of SnPb alloys. Hermetic sealing of the valve prototypes was demonstrated through helium leak testing, and Mil spec leak rates less than 1 × 10 −9 atm cm 3 /s were achieved. This confirms that the sample capture and analysis interval can be greatly expanded, easing the logistical burdens of ubiquitous GHG monitoring. Highly conservative and hypothetical CO 2 bias due to valve actuation at altitude in 1 cm 3 microsamplers would be significantly below 1.0 and 2.2 ppmv for heat-treated InBi and SnPb solders, respectively. The CO 2 bias from the PCμV scales well, as a doubling of sampler volume halved the bias. We estimated the shelf life of the SnPb PCμVs to be at least 2.8 years. These efforts will enable the development of low cost, low dead volume, small size/weight microsystems for monitoring GHGs and volatile organic compounds.</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNp1kc1u1DAURi1URKeFBS-AvKtYpPWNnUyM1MWooj9SJTawtm6cmxmjJA62ZySegNfGzITu6o035x77-y5jH0Fcg6jlDVzLummaqn7DViAaXazrUp6xlRBSFfVaNefsIsafIp8K4B07L0tVl43WK_bnaTq4RB3fhOTsQF_4ho-YKDgcInfTgWJyW0zOT9z3HPm8w0iF3eG0JT46G3xxwOFAvPeBbwPRtPP7SHyLkVs_DGSPszh13KcdBT77RFPKeo7zPDh7dMf37G2fX6QPy33Jftx__X73WDx_e3i62zwXVgmVCilA6a6FSoJei5Y6K7FD3XdrtEBV3wNI2zVUKy2Fam3OqxUAilb2SFrLS3Z18s7B_9rncGZ00dIw4ET530bXspFQlSKTn09kjhhjoN7MwY0YfhsQ5l_tBsxSe2Y_LdZ9O1L3Qv7vOQO3JyBal46JX7ctGzHLRszGjPIvyAmUPw</recordid><startdate>20120301</startdate><enddate>20120301</enddate><creator>Manginell, Ronald P.</creator><creator>Moorman, Matthew W.</creator><creator>Rejent, Jerome A.</creator><creator>Vianco, Paul T.</creator><creator>Grazier, Mark J.</creator><creator>Wroblewski, Brian D.</creator><creator>Mowry, Curtis D.</creator><creator>Achyuthan, Komandoor E.</creator><general>American Institute of Physics</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20120301</creationdate><title>Invited Article: A materials investigation of a phase-change micro-valve for greenhouse gas collection and other potential applications</title><author>Manginell, Ronald P. ; Moorman, Matthew W. ; Rejent, Jerome A. ; Vianco, Paul T. ; Grazier, Mark J. ; Wroblewski, Brian D. ; Mowry, Curtis D. ; Achyuthan, Komandoor E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c404t-30149db1531970bedc3ada9fd7ac1e5ff113cd8e649304bc0519411a0b3fae993</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Manginell, Ronald P.</creatorcontrib><creatorcontrib>Moorman, Matthew W.</creatorcontrib><creatorcontrib>Rejent, Jerome A.</creatorcontrib><creatorcontrib>Vianco, Paul T.</creatorcontrib><creatorcontrib>Grazier, Mark J.</creatorcontrib><creatorcontrib>Wroblewski, Brian D.</creatorcontrib><creatorcontrib>Mowry, Curtis D.</creatorcontrib><creatorcontrib>Achyuthan, Komandoor E.</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Manginell, Ronald P.</au><au>Moorman, Matthew W.</au><au>Rejent, Jerome A.</au><au>Vianco, Paul T.</au><au>Grazier, Mark J.</au><au>Wroblewski, Brian D.</au><au>Mowry, Curtis D.</au><au>Achyuthan, Komandoor E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Invited Article: A materials investigation of a phase-change micro-valve for greenhouse gas collection and other potential applications</atitle><jtitle>Review of scientific instruments</jtitle><addtitle>Rev Sci Instrum</addtitle><date>2012-03-01</date><risdate>2012</risdate><volume>83</volume><issue>3</issue><spage>031301</spage><epage>031301-11</epage><pages>031301-031301-11</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>The deleterious consequences of climate change are well documented. Future climate treaties might mandate greenhouse gas (GHG) emissions measurement from signatories in order to verify compliance. The acquisition of atmospheric chemistry would benefit from low cost, small size/weight/power of microsystems. In this paper, we investigated several key materials science aspects of a phase-change microvalve (PCμV) technology with low power/size/weight/cost for ubiquitous GHG sampling. The novel design, based on phase-change material low-melting-point eutectic metal alloys (indium-bismuth, InBi and tin-lead, SnPb), could be actuated at temperatures as low as 72 °C. Valve manufacturing was based on standard thick and thin-film processes and solder technologies that are commonly used in industry, enabling low-cost, high-volume fabrication. Aging studies showed that it was feasible to batch fabricate the PCμVs and store them for future use, especially in the case of SnPb alloys. Hermetic sealing of the valve prototypes was demonstrated through helium leak testing, and Mil spec leak rates less than 1 × 10 −9 atm cm 3 /s were achieved. This confirms that the sample capture and analysis interval can be greatly expanded, easing the logistical burdens of ubiquitous GHG monitoring. Highly conservative and hypothetical CO 2 bias due to valve actuation at altitude in 1 cm 3 microsamplers would be significantly below 1.0 and 2.2 ppmv for heat-treated InBi and SnPb solders, respectively. The CO 2 bias from the PCμV scales well, as a doubling of sampler volume halved the bias. We estimated the shelf life of the SnPb PCμVs to be at least 2.8 years. These efforts will enable the development of low cost, low dead volume, small size/weight microsystems for monitoring GHGs and volatile organic compounds.</abstract><cop>United States</cop><pub>American Institute of Physics</pub><pmid>22462899</pmid><doi>10.1063/1.3688856</doi><tpages>1</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 2012-03, Vol.83 (3), p.031301-031301-11
issn 0034-6748
1089-7623
language eng
recordid cdi_proquest_miscellaneous_963831520
source AIP Journals Complete; AIP Digital Archive; Alma/SFX Local Collection
title Invited Article: A materials investigation of a phase-change micro-valve for greenhouse gas collection and other potential applications
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T05%3A18%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Invited%20Article:%20A%20materials%20investigation%20of%20a%20phase-change%20micro-valve%20for%20greenhouse%20gas%20collection%20and%20other%20potential%20applications&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Manginell,%20Ronald%20P.&rft.date=2012-03-01&rft.volume=83&rft.issue=3&rft.spage=031301&rft.epage=031301-11&rft.pages=031301-031301-11&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.3688856&rft_dat=%3Cproquest_cross%3E963831520%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=963831520&rft_id=info:pmid/22462899&rfr_iscdi=true