Ultra high-performance liquid chromatography of porphyrins

ABSTRACT An ultra high‐performance liquid chromatographic (UHPLC) system was developed and optimized for the separation of porphyrins of clinical interest. Optimum conditions for the simultaneous separation of uroporphyrin, hepta‐, hexa‐, penta‐carboxylic acid porphyrins and coproporphyrin and their...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biomedical chromatography 2012-03, Vol.26 (3), p.331-337
Hauptverfasser: Benton, Christopher M., Lim, Chang Kee, Ritchie, Harald J., Moniz, Caje, Jones, Donald J.L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 337
container_issue 3
container_start_page 331
container_title Biomedical chromatography
container_volume 26
creator Benton, Christopher M.
Lim, Chang Kee
Ritchie, Harald J.
Moniz, Caje
Jones, Donald J.L.
description ABSTRACT An ultra high‐performance liquid chromatographic (UHPLC) system was developed and optimized for the separation of porphyrins of clinical interest. Optimum conditions for the simultaneous separation of uroporphyrin, hepta‐, hexa‐, penta‐carboxylic acid porphyrins and coproporphyrin and their type I and III isomers on a Thermo Hypersil BDS C18 column (2.4 µm particle size, 100 × 2.1 mm i.d.) using a gradient elution with 10% (v/v) acetonitrile in 1.0 m ammonium acetate buffer (pH 5.16) and 10% (v/v) acetonitrile in methanol at a flow‐rate of 0.4 mL/min. The effect of mobile phase buffer molarity on the sensitivity of fluorescence detection and resolution of porphyrin isomers was investigated. The method was successfully applied to the analysis of porphyrins extracted from the urine and faeces of patients with various human porphyrias. Copyright © 2011 John Wiley & Sons, Ltd.
doi_str_mv 10.1002/bmc.1662
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_920228417</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>920228417</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4242-ee1664711f833b0f18ee021e6a6b2fc7c6053c0b766b29948def9725748372b3</originalsourceid><addsrcrecordid>eNp1kF1PwjAUQBujEUQTf4HZm74M-zH64ZsSRQlqTDDy1nSlY9WNjnaL8u8dAXnzqbfJycm9B4BzBPsIQnydlrqPKMUHoIugEDHkEB2CLsRUxIQz0QEnIXxCCAXF7Bh0MGIEE8G74Oa9qL2KcrvI48r4zPlSLbWJCrtq7DzSuXelqt3CqypfRy6LKufbydtlOAVHmSqCOdu9PTB9uJ8OH-PJ6-hpeDuJdYITHBvTbpYwhDJOSAozxI2BGBmqaIozzTSFA6Jhymj7FyLhc5MJhgcs4YThlPTA5VZbebdqTKhlaYM2RaGWxjVBCgwx5kl7UQ9cbUntXQjeZLLytlR-LRGUm06y7SQ3nVr0Yidt0tLM9-BfmBaIt8C3Lcz6X5G8ex7uhDvehtr87HnlvyRlhA3kx8tITmZv4_F0ROSM_AK8wH-r</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>920228417</pqid></control><display><type>article</type><title>Ultra high-performance liquid chromatography of porphyrins</title><source>MEDLINE</source><source>Wiley Journals</source><creator>Benton, Christopher M. ; Lim, Chang Kee ; Ritchie, Harald J. ; Moniz, Caje ; Jones, Donald J.L.</creator><creatorcontrib>Benton, Christopher M. ; Lim, Chang Kee ; Ritchie, Harald J. ; Moniz, Caje ; Jones, Donald J.L.</creatorcontrib><description>ABSTRACT An ultra high‐performance liquid chromatographic (UHPLC) system was developed and optimized for the separation of porphyrins of clinical interest. Optimum conditions for the simultaneous separation of uroporphyrin, hepta‐, hexa‐, penta‐carboxylic acid porphyrins and coproporphyrin and their type I and III isomers on a Thermo Hypersil BDS C18 column (2.4 µm particle size, 100 × 2.1 mm i.d.) using a gradient elution with 10% (v/v) acetonitrile in 1.0 m ammonium acetate buffer (pH 5.16) and 10% (v/v) acetonitrile in methanol at a flow‐rate of 0.4 mL/min. The effect of mobile phase buffer molarity on the sensitivity of fluorescence detection and resolution of porphyrin isomers was investigated. The method was successfully applied to the analysis of porphyrins extracted from the urine and faeces of patients with various human porphyrias. Copyright © 2011 John Wiley &amp; Sons, Ltd.</description><identifier>ISSN: 0269-3879</identifier><identifier>EISSN: 1099-0801</identifier><identifier>DOI: 10.1002/bmc.1662</identifier><identifier>PMID: 21732398</identifier><language>eng</language><publisher>Chichester, UK: John Wiley &amp; Sons, Ltd</publisher><subject>Chromatography, High Pressure Liquid - methods ; Feces ; Humans ; porphyrias ; Porphyrias - metabolism ; Porphyrias - urine ; porphyrin profiles in urine and faeces ; porphyrins ; Porphyrins - analysis ; Solid Phase Extraction ; Spectrometry, Fluorescence ; UHPLC</subject><ispartof>Biomedical chromatography, 2012-03, Vol.26 (3), p.331-337</ispartof><rights>Copyright © 2011 John Wiley &amp; Sons, Ltd.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4242-ee1664711f833b0f18ee021e6a6b2fc7c6053c0b766b29948def9725748372b3</citedby><cites>FETCH-LOGICAL-c4242-ee1664711f833b0f18ee021e6a6b2fc7c6053c0b766b29948def9725748372b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fbmc.1662$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fbmc.1662$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21732398$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Benton, Christopher M.</creatorcontrib><creatorcontrib>Lim, Chang Kee</creatorcontrib><creatorcontrib>Ritchie, Harald J.</creatorcontrib><creatorcontrib>Moniz, Caje</creatorcontrib><creatorcontrib>Jones, Donald J.L.</creatorcontrib><title>Ultra high-performance liquid chromatography of porphyrins</title><title>Biomedical chromatography</title><addtitle>Biomed. Chromatogr</addtitle><description>ABSTRACT An ultra high‐performance liquid chromatographic (UHPLC) system was developed and optimized for the separation of porphyrins of clinical interest. Optimum conditions for the simultaneous separation of uroporphyrin, hepta‐, hexa‐, penta‐carboxylic acid porphyrins and coproporphyrin and their type I and III isomers on a Thermo Hypersil BDS C18 column (2.4 µm particle size, 100 × 2.1 mm i.d.) using a gradient elution with 10% (v/v) acetonitrile in 1.0 m ammonium acetate buffer (pH 5.16) and 10% (v/v) acetonitrile in methanol at a flow‐rate of 0.4 mL/min. The effect of mobile phase buffer molarity on the sensitivity of fluorescence detection and resolution of porphyrin isomers was investigated. The method was successfully applied to the analysis of porphyrins extracted from the urine and faeces of patients with various human porphyrias. Copyright © 2011 John Wiley &amp; Sons, Ltd.</description><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Feces</subject><subject>Humans</subject><subject>porphyrias</subject><subject>Porphyrias - metabolism</subject><subject>Porphyrias - urine</subject><subject>porphyrin profiles in urine and faeces</subject><subject>porphyrins</subject><subject>Porphyrins - analysis</subject><subject>Solid Phase Extraction</subject><subject>Spectrometry, Fluorescence</subject><subject>UHPLC</subject><issn>0269-3879</issn><issn>1099-0801</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kF1PwjAUQBujEUQTf4HZm74M-zH64ZsSRQlqTDDy1nSlY9WNjnaL8u8dAXnzqbfJycm9B4BzBPsIQnydlrqPKMUHoIugEDHkEB2CLsRUxIQz0QEnIXxCCAXF7Bh0MGIEE8G74Oa9qL2KcrvI48r4zPlSLbWJCrtq7DzSuXelqt3CqypfRy6LKufbydtlOAVHmSqCOdu9PTB9uJ8OH-PJ6-hpeDuJdYITHBvTbpYwhDJOSAozxI2BGBmqaIozzTSFA6Jhymj7FyLhc5MJhgcs4YThlPTA5VZbebdqTKhlaYM2RaGWxjVBCgwx5kl7UQ9cbUntXQjeZLLytlR-LRGUm06y7SQ3nVr0Yidt0tLM9-BfmBaIt8C3Lcz6X5G8ex7uhDvehtr87HnlvyRlhA3kx8tITmZv4_F0ROSM_AK8wH-r</recordid><startdate>201203</startdate><enddate>201203</enddate><creator>Benton, Christopher M.</creator><creator>Lim, Chang Kee</creator><creator>Ritchie, Harald J.</creator><creator>Moniz, Caje</creator><creator>Jones, Donald J.L.</creator><general>John Wiley &amp; Sons, Ltd</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201203</creationdate><title>Ultra high-performance liquid chromatography of porphyrins</title><author>Benton, Christopher M. ; Lim, Chang Kee ; Ritchie, Harald J. ; Moniz, Caje ; Jones, Donald J.L.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4242-ee1664711f833b0f18ee021e6a6b2fc7c6053c0b766b29948def9725748372b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Feces</topic><topic>Humans</topic><topic>porphyrias</topic><topic>Porphyrias - metabolism</topic><topic>Porphyrias - urine</topic><topic>porphyrin profiles in urine and faeces</topic><topic>porphyrins</topic><topic>Porphyrins - analysis</topic><topic>Solid Phase Extraction</topic><topic>Spectrometry, Fluorescence</topic><topic>UHPLC</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Benton, Christopher M.</creatorcontrib><creatorcontrib>Lim, Chang Kee</creatorcontrib><creatorcontrib>Ritchie, Harald J.</creatorcontrib><creatorcontrib>Moniz, Caje</creatorcontrib><creatorcontrib>Jones, Donald J.L.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Biomedical chromatography</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Benton, Christopher M.</au><au>Lim, Chang Kee</au><au>Ritchie, Harald J.</au><au>Moniz, Caje</au><au>Jones, Donald J.L.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ultra high-performance liquid chromatography of porphyrins</atitle><jtitle>Biomedical chromatography</jtitle><addtitle>Biomed. Chromatogr</addtitle><date>2012-03</date><risdate>2012</risdate><volume>26</volume><issue>3</issue><spage>331</spage><epage>337</epage><pages>331-337</pages><issn>0269-3879</issn><eissn>1099-0801</eissn><abstract>ABSTRACT An ultra high‐performance liquid chromatographic (UHPLC) system was developed and optimized for the separation of porphyrins of clinical interest. Optimum conditions for the simultaneous separation of uroporphyrin, hepta‐, hexa‐, penta‐carboxylic acid porphyrins and coproporphyrin and their type I and III isomers on a Thermo Hypersil BDS C18 column (2.4 µm particle size, 100 × 2.1 mm i.d.) using a gradient elution with 10% (v/v) acetonitrile in 1.0 m ammonium acetate buffer (pH 5.16) and 10% (v/v) acetonitrile in methanol at a flow‐rate of 0.4 mL/min. The effect of mobile phase buffer molarity on the sensitivity of fluorescence detection and resolution of porphyrin isomers was investigated. The method was successfully applied to the analysis of porphyrins extracted from the urine and faeces of patients with various human porphyrias. Copyright © 2011 John Wiley &amp; Sons, Ltd.</abstract><cop>Chichester, UK</cop><pub>John Wiley &amp; Sons, Ltd</pub><pmid>21732398</pmid><doi>10.1002/bmc.1662</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0269-3879
ispartof Biomedical chromatography, 2012-03, Vol.26 (3), p.331-337
issn 0269-3879
1099-0801
language eng
recordid cdi_proquest_miscellaneous_920228417
source MEDLINE; Wiley Journals
subjects Chromatography, High Pressure Liquid - methods
Feces
Humans
porphyrias
Porphyrias - metabolism
Porphyrias - urine
porphyrin profiles in urine and faeces
porphyrins
Porphyrins - analysis
Solid Phase Extraction
Spectrometry, Fluorescence
UHPLC
title Ultra high-performance liquid chromatography of porphyrins
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T12%3A50%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ultra%20high-performance%20liquid%20chromatography%20of%20porphyrins&rft.jtitle=Biomedical%20chromatography&rft.au=Benton,%20Christopher%20M.&rft.date=2012-03&rft.volume=26&rft.issue=3&rft.spage=331&rft.epage=337&rft.pages=331-337&rft.issn=0269-3879&rft.eissn=1099-0801&rft_id=info:doi/10.1002/bmc.1662&rft_dat=%3Cproquest_cross%3E920228417%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=920228417&rft_id=info:pmid/21732398&rfr_iscdi=true