The calibration of Bonner sphere spectrometer

Bonner sphere spectrometer (BSS) is used in radiation protection measurement because of its wide energy range (thermal to MeV) and easy operation. Mitsubishi Heavy Industries (MHI) has used BSS to obtain neutron spectrum and has used the neutron spectrum to estimate neutron dose or induced activity....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiation protection dosimetry 2011-07, Vol.146 (1-3), p.107-110
Hauptverfasser: Ogata, Tomohiro, Kudo, Seiichi, Watanabe, Yuya, Muramatsu, Takashi, Yamamoto, Hiroaki, Iwai, Satoshi, Takagi, Shunji, Harano, Hideki, Matsumoto, Tetsuro, Nishiyama, Jun
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 110
container_issue 1-3
container_start_page 107
container_title Radiation protection dosimetry
container_volume 146
creator Ogata, Tomohiro
Kudo, Seiichi
Watanabe, Yuya
Muramatsu, Takashi
Yamamoto, Hiroaki
Iwai, Satoshi
Takagi, Shunji
Harano, Hideki
Matsumoto, Tetsuro
Nishiyama, Jun
description Bonner sphere spectrometer (BSS) is used in radiation protection measurement because of its wide energy range (thermal to MeV) and easy operation. Mitsubishi Heavy Industries (MHI) has used BSS to obtain neutron spectrum and has used the neutron spectrum to estimate neutron dose or induced activity. Calibration of BSS is important to estimate precise neutron dose or induced activity. MHI BSS was calibrated at National Institute of Advanced Industrial Science and Technology (AIST). The calibration results at AIST are in good agreement with calculation results.
doi_str_mv 10.1093/rpd/ncr123
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_918044595</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><oup_id>10.1093/rpd/ncr123</oup_id><sourcerecordid>875489363</sourcerecordid><originalsourceid>FETCH-LOGICAL-c348t-7905d3fd65861b61febad3473b97b9fe264fccd94afa7c4ea5093ff26ea080f43</originalsourceid><addsrcrecordid>eNqF0EtLxDAUhuEgio6jG3-AdCOCUCeXk7RZ6uANBtyM65KmJ0ylbWrSLvz3Vjq61NXZPHxwXkIuGL1lVItV6KtVZwPj4oAsWAY8FUDVIVlQBpDmwOkJOY3xnVKeaQnH5IQzxQRXckHS7Q4Ta5q6DGaofZd4l9z7rsOQxH6HAaeDdgi-xQHDGTlypol4vr9L8vb4sF0_p5vXp5f13Sa1AvIhzTSVlXCVkrlipWIOS1MJyESps1I75AqctZUG40xmAY2c3nCOKzQ0pw7EklzPu33wHyPGoWjraLFpTId-jIVmOQWQWv4r80xCroUSk7yZpQ0-xoCu6EPdmvBZMFp8dyymjsXcccKX-9mxbLH6pT_hJnA1Az_2fw19AeBoeuI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>875489363</pqid></control><display><type>article</type><title>The calibration of Bonner sphere spectrometer</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><source>Oxford Journals</source><creator>Ogata, Tomohiro ; Kudo, Seiichi ; Watanabe, Yuya ; Muramatsu, Takashi ; Yamamoto, Hiroaki ; Iwai, Satoshi ; Takagi, Shunji ; Harano, Hideki ; Matsumoto, Tetsuro ; Nishiyama, Jun</creator><creatorcontrib>Ogata, Tomohiro ; Kudo, Seiichi ; Watanabe, Yuya ; Muramatsu, Takashi ; Yamamoto, Hiroaki ; Iwai, Satoshi ; Takagi, Shunji ; Harano, Hideki ; Matsumoto, Tetsuro ; Nishiyama, Jun</creatorcontrib><description>Bonner sphere spectrometer (BSS) is used in radiation protection measurement because of its wide energy range (thermal to MeV) and easy operation. Mitsubishi Heavy Industries (MHI) has used BSS to obtain neutron spectrum and has used the neutron spectrum to estimate neutron dose or induced activity. Calibration of BSS is important to estimate precise neutron dose or induced activity. MHI BSS was calibrated at National Institute of Advanced Industrial Science and Technology (AIST). The calibration results at AIST are in good agreement with calculation results.</description><identifier>ISSN: 0144-8420</identifier><identifier>EISSN: 1742-3406</identifier><identifier>DOI: 10.1093/rpd/ncr123</identifier><identifier>PMID: 21613265</identifier><language>eng</language><publisher>England: Oxford University Press</publisher><subject>Calibration ; Dosimetry ; Equipment Design ; Humans ; Neutrons ; Radiation Dosage ; Radiation Protection - instrumentation ; Radiation Protection - standards ; Technology</subject><ispartof>Radiation protection dosimetry, 2011-07, Vol.146 (1-3), p.107-110</ispartof><rights>The Author 2011. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com 2011</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c348t-7905d3fd65861b61febad3473b97b9fe264fccd94afa7c4ea5093ff26ea080f43</citedby><cites>FETCH-LOGICAL-c348t-7905d3fd65861b61febad3473b97b9fe264fccd94afa7c4ea5093ff26ea080f43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1578,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21613265$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ogata, Tomohiro</creatorcontrib><creatorcontrib>Kudo, Seiichi</creatorcontrib><creatorcontrib>Watanabe, Yuya</creatorcontrib><creatorcontrib>Muramatsu, Takashi</creatorcontrib><creatorcontrib>Yamamoto, Hiroaki</creatorcontrib><creatorcontrib>Iwai, Satoshi</creatorcontrib><creatorcontrib>Takagi, Shunji</creatorcontrib><creatorcontrib>Harano, Hideki</creatorcontrib><creatorcontrib>Matsumoto, Tetsuro</creatorcontrib><creatorcontrib>Nishiyama, Jun</creatorcontrib><title>The calibration of Bonner sphere spectrometer</title><title>Radiation protection dosimetry</title><addtitle>Radiat Prot Dosimetry</addtitle><description>Bonner sphere spectrometer (BSS) is used in radiation protection measurement because of its wide energy range (thermal to MeV) and easy operation. Mitsubishi Heavy Industries (MHI) has used BSS to obtain neutron spectrum and has used the neutron spectrum to estimate neutron dose or induced activity. Calibration of BSS is important to estimate precise neutron dose or induced activity. MHI BSS was calibrated at National Institute of Advanced Industrial Science and Technology (AIST). The calibration results at AIST are in good agreement with calculation results.</description><subject>Calibration</subject><subject>Dosimetry</subject><subject>Equipment Design</subject><subject>Humans</subject><subject>Neutrons</subject><subject>Radiation Dosage</subject><subject>Radiation Protection - instrumentation</subject><subject>Radiation Protection - standards</subject><subject>Technology</subject><issn>0144-8420</issn><issn>1742-3406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqF0EtLxDAUhuEgio6jG3-AdCOCUCeXk7RZ6uANBtyM65KmJ0ylbWrSLvz3Vjq61NXZPHxwXkIuGL1lVItV6KtVZwPj4oAsWAY8FUDVIVlQBpDmwOkJOY3xnVKeaQnH5IQzxQRXckHS7Q4Ta5q6DGaofZd4l9z7rsOQxH6HAaeDdgi-xQHDGTlypol4vr9L8vb4sF0_p5vXp5f13Sa1AvIhzTSVlXCVkrlipWIOS1MJyESps1I75AqctZUG40xmAY2c3nCOKzQ0pw7EklzPu33wHyPGoWjraLFpTId-jIVmOQWQWv4r80xCroUSk7yZpQ0-xoCu6EPdmvBZMFp8dyymjsXcccKX-9mxbLH6pT_hJnA1Az_2fw19AeBoeuI</recordid><startdate>20110701</startdate><enddate>20110701</enddate><creator>Ogata, Tomohiro</creator><creator>Kudo, Seiichi</creator><creator>Watanabe, Yuya</creator><creator>Muramatsu, Takashi</creator><creator>Yamamoto, Hiroaki</creator><creator>Iwai, Satoshi</creator><creator>Takagi, Shunji</creator><creator>Harano, Hideki</creator><creator>Matsumoto, Tetsuro</creator><creator>Nishiyama, Jun</creator><general>Oxford University Press</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope></search><sort><creationdate>20110701</creationdate><title>The calibration of Bonner sphere spectrometer</title><author>Ogata, Tomohiro ; Kudo, Seiichi ; Watanabe, Yuya ; Muramatsu, Takashi ; Yamamoto, Hiroaki ; Iwai, Satoshi ; Takagi, Shunji ; Harano, Hideki ; Matsumoto, Tetsuro ; Nishiyama, Jun</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c348t-7905d3fd65861b61febad3473b97b9fe264fccd94afa7c4ea5093ff26ea080f43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Calibration</topic><topic>Dosimetry</topic><topic>Equipment Design</topic><topic>Humans</topic><topic>Neutrons</topic><topic>Radiation Dosage</topic><topic>Radiation Protection - instrumentation</topic><topic>Radiation Protection - standards</topic><topic>Technology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ogata, Tomohiro</creatorcontrib><creatorcontrib>Kudo, Seiichi</creatorcontrib><creatorcontrib>Watanabe, Yuya</creatorcontrib><creatorcontrib>Muramatsu, Takashi</creatorcontrib><creatorcontrib>Yamamoto, Hiroaki</creatorcontrib><creatorcontrib>Iwai, Satoshi</creatorcontrib><creatorcontrib>Takagi, Shunji</creatorcontrib><creatorcontrib>Harano, Hideki</creatorcontrib><creatorcontrib>Matsumoto, Tetsuro</creatorcontrib><creatorcontrib>Nishiyama, Jun</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><jtitle>Radiation protection dosimetry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ogata, Tomohiro</au><au>Kudo, Seiichi</au><au>Watanabe, Yuya</au><au>Muramatsu, Takashi</au><au>Yamamoto, Hiroaki</au><au>Iwai, Satoshi</au><au>Takagi, Shunji</au><au>Harano, Hideki</au><au>Matsumoto, Tetsuro</au><au>Nishiyama, Jun</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The calibration of Bonner sphere spectrometer</atitle><jtitle>Radiation protection dosimetry</jtitle><addtitle>Radiat Prot Dosimetry</addtitle><date>2011-07-01</date><risdate>2011</risdate><volume>146</volume><issue>1-3</issue><spage>107</spage><epage>110</epage><pages>107-110</pages><issn>0144-8420</issn><eissn>1742-3406</eissn><abstract>Bonner sphere spectrometer (BSS) is used in radiation protection measurement because of its wide energy range (thermal to MeV) and easy operation. Mitsubishi Heavy Industries (MHI) has used BSS to obtain neutron spectrum and has used the neutron spectrum to estimate neutron dose or induced activity. Calibration of BSS is important to estimate precise neutron dose or induced activity. MHI BSS was calibrated at National Institute of Advanced Industrial Science and Technology (AIST). The calibration results at AIST are in good agreement with calculation results.</abstract><cop>England</cop><pub>Oxford University Press</pub><pmid>21613265</pmid><doi>10.1093/rpd/ncr123</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0144-8420
ispartof Radiation protection dosimetry, 2011-07, Vol.146 (1-3), p.107-110
issn 0144-8420
1742-3406
language eng
recordid cdi_proquest_miscellaneous_918044595
source MEDLINE; Alma/SFX Local Collection; Oxford Journals
subjects Calibration
Dosimetry
Equipment Design
Humans
Neutrons
Radiation Dosage
Radiation Protection - instrumentation
Radiation Protection - standards
Technology
title The calibration of Bonner sphere spectrometer
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-04T14%3A40%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20calibration%20of%20Bonner%20sphere%20spectrometer&rft.jtitle=Radiation%20protection%20dosimetry&rft.au=Ogata,%20Tomohiro&rft.date=2011-07-01&rft.volume=146&rft.issue=1-3&rft.spage=107&rft.epage=110&rft.pages=107-110&rft.issn=0144-8420&rft.eissn=1742-3406&rft_id=info:doi/10.1093/rpd/ncr123&rft_dat=%3Cproquest_cross%3E875489363%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=875489363&rft_id=info:pmid/21613265&rft_oup_id=10.1093/rpd/ncr123&rfr_iscdi=true