Semi-empirical relationship for photon buildup factor in soft tissue and water
Buildup factor of gamma and X-ray photons in the energy range of 0.2–2 MeV in water and soft tissue is computed using Monte Carlo code MCNP4C. The results are compared with the buildup factor data of pure water. A new relationship estimating buildup factor as a function of penetration depth, Compton...
Gespeichert in:
Veröffentlicht in: | Radiation protection dosimetry 2010-12, Vol.142 (2-4), p.209-212 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Buildup factor of gamma and X-ray photons in the energy range of 0.2–2 MeV in water and soft tissue is computed using Monte Carlo code MCNP4C. The results are compared with the buildup factor data of pure water. A new relationship estimating buildup factor as a function of penetration depth, Compton scattering and energy absorption cross sections is introduced. The new relationship estimates buildup factor with 5 % deviation compared with the existing data. |
---|---|
ISSN: | 0144-8420 1742-3406 |
DOI: | 10.1093/rpd/ncq212 |