Temperature Dependence of Particle Size Distribution in Transformer Oil-Based Ferrofluid
The temperature dependence of the particle size distribution (PSD) of a transformer oil-based ferrofluid was studied using an ultrasound method. The measurements of the ultrasound velocity and attenuation were carried out in the absence of an external magnetic field as a function of the volume conce...
Gespeichert in:
Veröffentlicht in: | International journal of thermophysics 2011-04, Vol.32 (4), p.795-806 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The temperature dependence of the particle size distribution (PSD) of a transformer oil-based ferrofluid was studied using an ultrasound method. The measurements of the ultrasound velocity and attenuation were carried out in the absence of an external magnetic field as a function of the volume concentration of magnetite particles at temperatures ranging from 10 °C to 80 °C. The experimental results of ultrasound measurements were analyzed within the framework of the Vinogradov–Isakovich theory which takes into account contributions to acoustical parameters due to friction and heat exchange between magnetic particles and the surrounding carrier liquid. From the best fit of the experimental results and theoretical predictions, the parameters characterizing the PSD at different temperatures were determined. In order to analyze ultrasonic data, the density and viscosity of ferrofluid samples and the transformer oil were also measured. |
---|---|
ISSN: | 0195-928X 1572-9567 |
DOI: | 10.1007/s10765-010-0895-5 |