Determination of Ca and Mg in aqueous solution by laser-induced breakdown spectroscopy using absorbent paper substrates
Laser-induced breakdown spectroscopy has been performed to detect trace metal elements (Ca and Mg) in aqueous solution. In order to overcome the sensitivity drawbacks in liquid sample analysis, an absorbent paper was used as the sample support in this experiment. Calibration curves were constructed...
Gespeichert in:
Veröffentlicht in: | Applied Optics 2011-10, Vol.50 (29), p.5695-5699 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 5699 |
---|---|
container_issue | 29 |
container_start_page | 5695 |
container_title | Applied Optics |
container_volume | 50 |
creator | Zhu, Dehua Wu, Lizhi Wang, Bin Chen, Jianping Lu, Jian Ni, Xiaowu |
description | Laser-induced breakdown spectroscopy has been performed to detect trace metal elements (Ca and Mg) in aqueous solution. In order to overcome the sensitivity drawbacks in liquid sample analysis, an absorbent paper was used as the sample support in this experiment. Calibration curves were constructed by using the standard solution with variable concentration and the limit of detection was estimated for each element. Finally this system was used to analyze three types of water samples collected from different locations in Nanjing, China and the results were compared with inductively coupled plasma atomic emission spectroscopy and showed good correlation. |
doi_str_mv | 10.1364/AO.50.005695 |
format | Article |
fullrecord | <record><control><sourceid>proquest_osti_</sourceid><recordid>TN_cdi_proquest_miscellaneous_900632165</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>900632165</sourcerecordid><originalsourceid>FETCH-LOGICAL-c384t-9d641471e256ff2f343b40d183e0fc619d1b5906007334562de057d2859fe54e3</originalsourceid><addsrcrecordid>eNo9kcuP0zAQxi0EYsvCjTOyxIELKeP4keZYlae0qBc4W449WQypHTyOVv3vydKF02iknz59D8ZeCtgKadS7_XGrYQugTa8fsU0rtG6kMPox2wCAbEwv9RV7RvRz_bTqu6fsqm1BaGnkht29x4rlFJOrMSeeR35w3KXAv97ymLj7vWBeiFOelr_AcOaTIyxNTGHxGPhQ0P0K-S5xmtHXksnn-cwXiumWu4FyGTBVPrsZC6dloFpcRXrOnoxuInzxcK_Z948fvh0-NzfHT18O-5vGy52qTR-MEqoT2Gozju0olRwUBLGTCKM3og9i0D0YgE5KpU0bEHQX2p3uR9QK5TV7fdHNVKMlHyv6Hz6ntHq1aw3SdEqt1JsLNZe8JqZqT5E8TpNL9_FtD2Bku5a6km8vpF-TUsHRziWeXDlbAfZ-D7s_Wg32sseKv3oQXoYThv_wvwHkH5eohac</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>900632165</pqid></control><display><type>article</type><title>Determination of Ca and Mg in aqueous solution by laser-induced breakdown spectroscopy using absorbent paper substrates</title><source>Alma/SFX Local Collection</source><source>Optica Publishing Group Journals</source><creator>Zhu, Dehua ; Wu, Lizhi ; Wang, Bin ; Chen, Jianping ; Lu, Jian ; Ni, Xiaowu</creator><creatorcontrib>Zhu, Dehua ; Wu, Lizhi ; Wang, Bin ; Chen, Jianping ; Lu, Jian ; Ni, Xiaowu</creatorcontrib><description>Laser-induced breakdown spectroscopy has been performed to detect trace metal elements (Ca and Mg) in aqueous solution. In order to overcome the sensitivity drawbacks in liquid sample analysis, an absorbent paper was used as the sample support in this experiment. Calibration curves were constructed by using the standard solution with variable concentration and the limit of detection was estimated for each element. Finally this system was used to analyze three types of water samples collected from different locations in Nanjing, China and the results were compared with inductively coupled plasma atomic emission spectroscopy and showed good correlation.</description><identifier>ISSN: 0003-6935</identifier><identifier>EISSN: 2155-3165</identifier><identifier>EISSN: 1539-4522</identifier><identifier>DOI: 10.1364/AO.50.005695</identifier><identifier>PMID: 22015363</identifier><language>eng</language><publisher>United States</publisher><subject>ABSORBENTS ; AQUEOUS SOLUTIONS ; ATOMIC AND MOLECULAR PHYSICS ; BREAKDOWN ; CALCIUM ; CALIBRATION ; CORRELATIONS ; DETECTION ; EMISSION SPECTROSCOPY ; LASER RADIATION ; MAGNESIUM ; METALS ; PLASMA ; SENSITIVITY ; SUBSTRATES ; WATER</subject><ispartof>Applied Optics, 2011-10, Vol.50 (29), p.5695-5699</ispartof><rights>2011 Optical Society of America</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c384t-9d641471e256ff2f343b40d183e0fc619d1b5906007334562de057d2859fe54e3</citedby><cites>FETCH-LOGICAL-c384t-9d641471e256ff2f343b40d183e0fc619d1b5906007334562de057d2859fe54e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,881,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22015363$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://www.osti.gov/biblio/22036744$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Zhu, Dehua</creatorcontrib><creatorcontrib>Wu, Lizhi</creatorcontrib><creatorcontrib>Wang, Bin</creatorcontrib><creatorcontrib>Chen, Jianping</creatorcontrib><creatorcontrib>Lu, Jian</creatorcontrib><creatorcontrib>Ni, Xiaowu</creatorcontrib><title>Determination of Ca and Mg in aqueous solution by laser-induced breakdown spectroscopy using absorbent paper substrates</title><title>Applied Optics</title><addtitle>Appl Opt</addtitle><description>Laser-induced breakdown spectroscopy has been performed to detect trace metal elements (Ca and Mg) in aqueous solution. In order to overcome the sensitivity drawbacks in liquid sample analysis, an absorbent paper was used as the sample support in this experiment. Calibration curves were constructed by using the standard solution with variable concentration and the limit of detection was estimated for each element. Finally this system was used to analyze three types of water samples collected from different locations in Nanjing, China and the results were compared with inductively coupled plasma atomic emission spectroscopy and showed good correlation.</description><subject>ABSORBENTS</subject><subject>AQUEOUS SOLUTIONS</subject><subject>ATOMIC AND MOLECULAR PHYSICS</subject><subject>BREAKDOWN</subject><subject>CALCIUM</subject><subject>CALIBRATION</subject><subject>CORRELATIONS</subject><subject>DETECTION</subject><subject>EMISSION SPECTROSCOPY</subject><subject>LASER RADIATION</subject><subject>MAGNESIUM</subject><subject>METALS</subject><subject>PLASMA</subject><subject>SENSITIVITY</subject><subject>SUBSTRATES</subject><subject>WATER</subject><issn>0003-6935</issn><issn>2155-3165</issn><issn>1539-4522</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNo9kcuP0zAQxi0EYsvCjTOyxIELKeP4keZYlae0qBc4W449WQypHTyOVv3vydKF02iknz59D8ZeCtgKadS7_XGrYQugTa8fsU0rtG6kMPox2wCAbEwv9RV7RvRz_bTqu6fsqm1BaGnkht29x4rlFJOrMSeeR35w3KXAv97ymLj7vWBeiFOelr_AcOaTIyxNTGHxGPhQ0P0K-S5xmtHXksnn-cwXiumWu4FyGTBVPrsZC6dloFpcRXrOnoxuInzxcK_Z948fvh0-NzfHT18O-5vGy52qTR-MEqoT2Gozju0olRwUBLGTCKM3og9i0D0YgE5KpU0bEHQX2p3uR9QK5TV7fdHNVKMlHyv6Hz6ntHq1aw3SdEqt1JsLNZe8JqZqT5E8TpNL9_FtD2Bku5a6km8vpF-TUsHRziWeXDlbAfZ-D7s_Wg32sseKv3oQXoYThv_wvwHkH5eohac</recordid><startdate>20111010</startdate><enddate>20111010</enddate><creator>Zhu, Dehua</creator><creator>Wu, Lizhi</creator><creator>Wang, Bin</creator><creator>Chen, Jianping</creator><creator>Lu, Jian</creator><creator>Ni, Xiaowu</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>OTOTI</scope></search><sort><creationdate>20111010</creationdate><title>Determination of Ca and Mg in aqueous solution by laser-induced breakdown spectroscopy using absorbent paper substrates</title><author>Zhu, Dehua ; Wu, Lizhi ; Wang, Bin ; Chen, Jianping ; Lu, Jian ; Ni, Xiaowu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c384t-9d641471e256ff2f343b40d183e0fc619d1b5906007334562de057d2859fe54e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>ABSORBENTS</topic><topic>AQUEOUS SOLUTIONS</topic><topic>ATOMIC AND MOLECULAR PHYSICS</topic><topic>BREAKDOWN</topic><topic>CALCIUM</topic><topic>CALIBRATION</topic><topic>CORRELATIONS</topic><topic>DETECTION</topic><topic>EMISSION SPECTROSCOPY</topic><topic>LASER RADIATION</topic><topic>MAGNESIUM</topic><topic>METALS</topic><topic>PLASMA</topic><topic>SENSITIVITY</topic><topic>SUBSTRATES</topic><topic>WATER</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhu, Dehua</creatorcontrib><creatorcontrib>Wu, Lizhi</creatorcontrib><creatorcontrib>Wang, Bin</creatorcontrib><creatorcontrib>Chen, Jianping</creatorcontrib><creatorcontrib>Lu, Jian</creatorcontrib><creatorcontrib>Ni, Xiaowu</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>OSTI.GOV</collection><jtitle>Applied Optics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhu, Dehua</au><au>Wu, Lizhi</au><au>Wang, Bin</au><au>Chen, Jianping</au><au>Lu, Jian</au><au>Ni, Xiaowu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of Ca and Mg in aqueous solution by laser-induced breakdown spectroscopy using absorbent paper substrates</atitle><jtitle>Applied Optics</jtitle><addtitle>Appl Opt</addtitle><date>2011-10-10</date><risdate>2011</risdate><volume>50</volume><issue>29</issue><spage>5695</spage><epage>5699</epage><pages>5695-5699</pages><issn>0003-6935</issn><eissn>2155-3165</eissn><eissn>1539-4522</eissn><abstract>Laser-induced breakdown spectroscopy has been performed to detect trace metal elements (Ca and Mg) in aqueous solution. In order to overcome the sensitivity drawbacks in liquid sample analysis, an absorbent paper was used as the sample support in this experiment. Calibration curves were constructed by using the standard solution with variable concentration and the limit of detection was estimated for each element. Finally this system was used to analyze three types of water samples collected from different locations in Nanjing, China and the results were compared with inductively coupled plasma atomic emission spectroscopy and showed good correlation.</abstract><cop>United States</cop><pmid>22015363</pmid><doi>10.1364/AO.50.005695</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0003-6935 |
ispartof | Applied Optics, 2011-10, Vol.50 (29), p.5695-5699 |
issn | 0003-6935 2155-3165 1539-4522 |
language | eng |
recordid | cdi_proquest_miscellaneous_900632165 |
source | Alma/SFX Local Collection; Optica Publishing Group Journals |
subjects | ABSORBENTS AQUEOUS SOLUTIONS ATOMIC AND MOLECULAR PHYSICS BREAKDOWN CALCIUM CALIBRATION CORRELATIONS DETECTION EMISSION SPECTROSCOPY LASER RADIATION MAGNESIUM METALS PLASMA SENSITIVITY SUBSTRATES WATER |
title | Determination of Ca and Mg in aqueous solution by laser-induced breakdown spectroscopy using absorbent paper substrates |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T21%3A41%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20Ca%20and%20Mg%20in%20aqueous%20solution%20by%20laser-induced%20breakdown%20spectroscopy%20using%20absorbent%20paper%20substrates&rft.jtitle=Applied%20Optics&rft.au=Zhu,%20Dehua&rft.date=2011-10-10&rft.volume=50&rft.issue=29&rft.spage=5695&rft.epage=5699&rft.pages=5695-5699&rft.issn=0003-6935&rft.eissn=2155-3165&rft_id=info:doi/10.1364/AO.50.005695&rft_dat=%3Cproquest_osti_%3E900632165%3C/proquest_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=900632165&rft_id=info:pmid/22015363&rfr_iscdi=true |