AN INVESTIGATION OF THE PULL-OUT STRENGTH OF ASPHALT CONCRETE EXPOSED TO VARYING FREEZING AND THAWING CYCLES
The stability of asphalt concrete under the effects of freezing and thawing has been studied experimentally using the Marshall and ultrasound methods. Ozgan used 10 cm diameter asphalt core samples which were alternately frozen (-20° C for 16 h) and thawed (16° C for 8 h) for 5, 10, 15, 20, 25 and 3...
Gespeichert in:
Veröffentlicht in: | Experimental techniques (Westport, Conn.) Conn.), 2011-07, Vol.35 (4), p.44-51 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 51 |
---|---|
container_issue | 4 |
container_start_page | 44 |
container_title | Experimental techniques (Westport, Conn.) |
container_volume | 35 |
creator | Ozgan, E. Bektas, S. |
description | The stability of asphalt concrete under the effects of freezing and thawing has been studied experimentally using the Marshall and ultrasound methods. Ozgan used 10 cm diameter asphalt core samples which were alternately frozen (-20° C for 16 h) and thawed (16° C for 8 h) for 5, 10, 15, 20, 25 and 30 cycles to simulate daily winter conditions. The stability of the asphalt concrete in the laboratory environment temperature of 17° C was used as a reference. The results showed that the stability of the asphalt core samples exposed to freezing and thawing increased, and this increase varied between 22.7 and 19.2% for the 5- and 30-day cycles, respectively. Here, Ozgan and Bektas investigate the effects of freezing-thawing on the pull-out strength of the asphalt concrete. The pull-out strength and ultrasound velocity of the asphalt core samples were exposed to different freezing-thawing cycle and examined experimentally. |
doi_str_mv | 10.1111/j.1747-1567.2010.00659.x |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_898415572</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2485699481</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4329-8b28649b205ab69ebc691fc6f6b1ee6a77b1b337ea589e42599b0da9d5e7b41e3</originalsourceid><addsrcrecordid>eNqNkF1vmzAUhq1pk5Z1-w--2xWpDfhL6g2jDiAhSIPTpruxMHWqZDTpcKOl_35mTL2ub_zqnPOcIz0AQIzm2L_L_RyzmAWYUDYPka8iRImYnz-A2VvjI5ghFoUB55h_Bl-c2yOECWZiBvqkgkV1KxtVZIkq6grWC6hyCZfrsgzqtYKNWskqU_nYSJplnpQKpnWVrqSSUG6WdSOvoarhbbK6L6oMLlZS_hxDUvl6ntyNOb1PS9l8BZ-2be_st___BVgvpErzoKyzIk3KoIujUATchJzGwoSItIYKazoq8LajW2qwtbRlzGATRcy2hAsbh0QIgx5a8UAsMzG20QX4Pu19Ho6_T9a96Ked62zftwd7PDnNBY8xISz0k3ya7Iajc4Pd6udh99QOrxojPfrVez1q1KNGPfrV__zqs0evJvTPrrev7-a03CgfPC4m3Hny8GgHvT-ehoPX8p7TwcTu3Is9v51uh1-asogRfVdlOv2BbjY3PNUs-guz4Jit</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>898415572</pqid></control><display><type>article</type><title>AN INVESTIGATION OF THE PULL-OUT STRENGTH OF ASPHALT CONCRETE EXPOSED TO VARYING FREEZING AND THAWING CYCLES</title><source>Wiley Online Library Journals Frontfile Complete</source><source>Springer Nature - Complete Springer Journals</source><creator>Ozgan, E. ; Bektas, S.</creator><creatorcontrib>Ozgan, E. ; Bektas, S.</creatorcontrib><description>The stability of asphalt concrete under the effects of freezing and thawing has been studied experimentally using the Marshall and ultrasound methods. Ozgan used 10 cm diameter asphalt core samples which were alternately frozen (-20° C for 16 h) and thawed (16° C for 8 h) for 5, 10, 15, 20, 25 and 30 cycles to simulate daily winter conditions. The stability of the asphalt concrete in the laboratory environment temperature of 17° C was used as a reference. The results showed that the stability of the asphalt core samples exposed to freezing and thawing increased, and this increase varied between 22.7 and 19.2% for the 5- and 30-day cycles, respectively. Here, Ozgan and Bektas investigate the effects of freezing-thawing on the pull-out strength of the asphalt concrete. The pull-out strength and ultrasound velocity of the asphalt core samples were exposed to different freezing-thawing cycle and examined experimentally.</description><identifier>ISSN: 0732-8818</identifier><identifier>EISSN: 1747-1567</identifier><identifier>DOI: 10.1111/j.1747-1567.2010.00659.x</identifier><identifier>CODEN: EXPTD2</identifier><language>eng</language><publisher>Oxford, UK: Blackwell Publishing Ltd</publisher><subject>Asphalt pavements ; Characterization and Evaluation of Materials ; Chemistry and Materials Science ; Concrete ; Experiments ; Freezing ; Materials Science ; Techniques ; Tests</subject><ispartof>Experimental techniques (Westport, Conn.), 2011-07, Vol.35 (4), p.44-51</ispartof><rights>Society for Experimental Mechanics, Inc. 2010</rights><rights>2010, Society for Experimental Mechanics</rights><rights>Copyright Blackwell Publishing Ltd. Jul/Aug 2011</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4329-8b28649b205ab69ebc691fc6f6b1ee6a77b1b337ea589e42599b0da9d5e7b41e3</citedby><cites>FETCH-LOGICAL-c4329-8b28649b205ab69ebc691fc6f6b1ee6a77b1b337ea589e42599b0da9d5e7b41e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1111/j.1747-1567.2010.00659.x$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1111/j.1747-1567.2010.00659.x$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,780,784,1416,27915,27916,41479,42548,45565,45566,51310</link.rule.ids></links><search><creatorcontrib>Ozgan, E.</creatorcontrib><creatorcontrib>Bektas, S.</creatorcontrib><title>AN INVESTIGATION OF THE PULL-OUT STRENGTH OF ASPHALT CONCRETE EXPOSED TO VARYING FREEZING AND THAWING CYCLES</title><title>Experimental techniques (Westport, Conn.)</title><addtitle>Exp Tech</addtitle><description>The stability of asphalt concrete under the effects of freezing and thawing has been studied experimentally using the Marshall and ultrasound methods. Ozgan used 10 cm diameter asphalt core samples which were alternately frozen (-20° C for 16 h) and thawed (16° C for 8 h) for 5, 10, 15, 20, 25 and 30 cycles to simulate daily winter conditions. The stability of the asphalt concrete in the laboratory environment temperature of 17° C was used as a reference. The results showed that the stability of the asphalt core samples exposed to freezing and thawing increased, and this increase varied between 22.7 and 19.2% for the 5- and 30-day cycles, respectively. Here, Ozgan and Bektas investigate the effects of freezing-thawing on the pull-out strength of the asphalt concrete. The pull-out strength and ultrasound velocity of the asphalt core samples were exposed to different freezing-thawing cycle and examined experimentally.</description><subject>Asphalt pavements</subject><subject>Characterization and Evaluation of Materials</subject><subject>Chemistry and Materials Science</subject><subject>Concrete</subject><subject>Experiments</subject><subject>Freezing</subject><subject>Materials Science</subject><subject>Techniques</subject><subject>Tests</subject><issn>0732-8818</issn><issn>1747-1567</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNqNkF1vmzAUhq1pk5Z1-w--2xWpDfhL6g2jDiAhSIPTpruxMHWqZDTpcKOl_35mTL2ub_zqnPOcIz0AQIzm2L_L_RyzmAWYUDYPka8iRImYnz-A2VvjI5ghFoUB55h_Bl-c2yOECWZiBvqkgkV1KxtVZIkq6grWC6hyCZfrsgzqtYKNWskqU_nYSJplnpQKpnWVrqSSUG6WdSOvoarhbbK6L6oMLlZS_hxDUvl6ntyNOb1PS9l8BZ-2be_st___BVgvpErzoKyzIk3KoIujUATchJzGwoSItIYKazoq8LajW2qwtbRlzGATRcy2hAsbh0QIgx5a8UAsMzG20QX4Pu19Ho6_T9a96Ked62zftwd7PDnNBY8xISz0k3ya7Iajc4Pd6udh99QOrxojPfrVez1q1KNGPfrV__zqs0evJvTPrrev7-a03CgfPC4m3Hny8GgHvT-ehoPX8p7TwcTu3Is9v51uh1-asogRfVdlOv2BbjY3PNUs-guz4Jit</recordid><startdate>201107</startdate><enddate>201107</enddate><creator>Ozgan, E.</creator><creator>Bektas, S.</creator><general>Blackwell Publishing Ltd</general><general>Springer International Publishing</general><general>Springer Nature B.V</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope></search><sort><creationdate>201107</creationdate><title>AN INVESTIGATION OF THE PULL-OUT STRENGTH OF ASPHALT CONCRETE EXPOSED TO VARYING FREEZING AND THAWING CYCLES</title><author>Ozgan, E. ; Bektas, S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4329-8b28649b205ab69ebc691fc6f6b1ee6a77b1b337ea589e42599b0da9d5e7b41e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Asphalt pavements</topic><topic>Characterization and Evaluation of Materials</topic><topic>Chemistry and Materials Science</topic><topic>Concrete</topic><topic>Experiments</topic><topic>Freezing</topic><topic>Materials Science</topic><topic>Techniques</topic><topic>Tests</topic><toplevel>online_resources</toplevel><creatorcontrib>Ozgan, E.</creatorcontrib><creatorcontrib>Bektas, S.</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Experimental techniques (Westport, Conn.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ozgan, E.</au><au>Bektas, S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>AN INVESTIGATION OF THE PULL-OUT STRENGTH OF ASPHALT CONCRETE EXPOSED TO VARYING FREEZING AND THAWING CYCLES</atitle><jtitle>Experimental techniques (Westport, Conn.)</jtitle><stitle>Exp Tech</stitle><date>2011-07</date><risdate>2011</risdate><volume>35</volume><issue>4</issue><spage>44</spage><epage>51</epage><pages>44-51</pages><issn>0732-8818</issn><eissn>1747-1567</eissn><coden>EXPTD2</coden><abstract>The stability of asphalt concrete under the effects of freezing and thawing has been studied experimentally using the Marshall and ultrasound methods. Ozgan used 10 cm diameter asphalt core samples which were alternately frozen (-20° C for 16 h) and thawed (16° C for 8 h) for 5, 10, 15, 20, 25 and 30 cycles to simulate daily winter conditions. The stability of the asphalt concrete in the laboratory environment temperature of 17° C was used as a reference. The results showed that the stability of the asphalt core samples exposed to freezing and thawing increased, and this increase varied between 22.7 and 19.2% for the 5- and 30-day cycles, respectively. Here, Ozgan and Bektas investigate the effects of freezing-thawing on the pull-out strength of the asphalt concrete. The pull-out strength and ultrasound velocity of the asphalt core samples were exposed to different freezing-thawing cycle and examined experimentally.</abstract><cop>Oxford, UK</cop><pub>Blackwell Publishing Ltd</pub><doi>10.1111/j.1747-1567.2010.00659.x</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0732-8818 |
ispartof | Experimental techniques (Westport, Conn.), 2011-07, Vol.35 (4), p.44-51 |
issn | 0732-8818 1747-1567 |
language | eng |
recordid | cdi_proquest_miscellaneous_898415572 |
source | Wiley Online Library Journals Frontfile Complete; Springer Nature - Complete Springer Journals |
subjects | Asphalt pavements Characterization and Evaluation of Materials Chemistry and Materials Science Concrete Experiments Freezing Materials Science Techniques Tests |
title | AN INVESTIGATION OF THE PULL-OUT STRENGTH OF ASPHALT CONCRETE EXPOSED TO VARYING FREEZING AND THAWING CYCLES |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T06%3A21%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=AN%20INVESTIGATION%20OF%20THE%20PULL-OUT%20STRENGTH%20OF%20ASPHALT%20CONCRETE%20EXPOSED%20TO%20VARYING%20FREEZING%20AND%20THAWING%20CYCLES&rft.jtitle=Experimental%20techniques%20(Westport,%20Conn.)&rft.au=Ozgan,%20E.&rft.date=2011-07&rft.volume=35&rft.issue=4&rft.spage=44&rft.epage=51&rft.pages=44-51&rft.issn=0732-8818&rft.eissn=1747-1567&rft.coden=EXPTD2&rft_id=info:doi/10.1111/j.1747-1567.2010.00659.x&rft_dat=%3Cproquest_cross%3E2485699481%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=898415572&rft_id=info:pmid/&rfr_iscdi=true |