Stochastic resonance electrical stimulation to improve proprioception in knee osteoarthritis

Abstract Proprioceptive deficits occur with knee osteoarthritis (OA) and improving proprioception may slow joint degeneration by allowing more appropriate joint loading. Stochastic resonance (SR) stimulation improves balance and the sensitivity of specific mechanoreceptors. Our purpose was to evalua...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The knee 2011-10, Vol.18 (5), p.317-322
Hauptverfasser: Collins, Amber T, Blackburn, J. Troy, Olcott, Chris W, Miles, Jodie, Jordan, Joanne, Dirschl, Douglas R, Weinhold, Paul S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 322
container_issue 5
container_start_page 317
container_title The knee
container_volume 18
creator Collins, Amber T
Blackburn, J. Troy
Olcott, Chris W
Miles, Jodie
Jordan, Joanne
Dirschl, Douglas R
Weinhold, Paul S
description Abstract Proprioceptive deficits occur with knee osteoarthritis (OA) and improving proprioception may slow joint degeneration by allowing more appropriate joint loading. Stochastic resonance (SR) stimulation improves balance and the sensitivity of specific mechanoreceptors. Our purpose was to evaluate the effects of SR electrical stimulation combined with a knee sleeve on proprioception in subjects with knee OA. Joint position sense (JPS) was measured in 38 subjects with knee OA during four conditions in both a partial weight-bearing (PWB) and non weight-bearing (NWB) task: no electrical stimulation/no sleeve, no electrical stimulation/sleeve, 50 μA-RMS stimulation/sleeve, and 75 μA-RMS stimulation/sleeve. Subjects also reported their knee pain, stiffness, functionality (WOMAC), and instability. Repeated measures ANOVA and Spearman correlations were performed to investigate differences between the conditions and relationships among the outcome measures. JPS during the 75 μA-RMS stimulation/sleeve and sleeve alone conditions was significantly improved compared to the control condition in the PWB task. However, the 75 μA-RMS stimulation/sleeve and the sleeve alone conditions did not differ from each other. A moderate correlation was found between the improvements with the 75 μA-RMS stimulation/sleeve condition compared to the JPS of the control condition in the PWB task. No differences in JPS were found between the four conditions in the NWB task. Significant correlations were found between the control JPS and WOMAC indices (p < 0.005). Improved proprioception during the PWB task was achieved with a sleeve alone and in combination with SR stimulation. The observed correlations suggest that subjects with larger proprioceptive deficits may benefit most from these therapies.
doi_str_mv 10.1016/j.knee.2010.07.001
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_885909369</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S0968016010001316</els_id><sourcerecordid>885909369</sourcerecordid><originalsourceid>FETCH-LOGICAL-c438t-94e40cfd1222779b80e1ead35482c8bf1d1f9f79b9e6359896abb1f3013bb4253</originalsourceid><addsrcrecordid>eNp9kcFq3DAQhkVpaDZpX6CHYuihJ29GkiVLUAohtGkhkEPaW0HI8phoY1tbSQ7k7St30xZyyMUCz_cPM98Q8pbClgKVZ7vt3Yy4ZVB-QLsFoC_IhqqW10IBvCQb0FLVhYRjcpLSDgCkbsQrcsxACtEKviE_b3JwtzZl76qIKcx2dljhiC5H7-xYlcq0jDb7MFc5VH7ax3CPVfnuow8O938qfq7WWaqQMgYb82302afX5GiwY8I3j-8p-fHl8_eLr_XV9eW3i_Or2jVc5Vo32IAbesoYa1vdKUCKtueiUcypbqA9HfRQCholF1ppabuODhwo77qGCX5KPhz6lql-LZiymXxyOI52xrAko5TQoLnUhXz_hNyFJc5lOEOBN1pJwaBQ7EC5GFKKOJiy62TjQ4HMqt7szLquWdUbaE1RX0LvHlsv3YT9v8hf1wX4eACwqLj3GE1yHovu3sei2_TBP9__05O4G_283ugOHzD938MkZsDcrMdfb09hTVPJfwPbqqq9</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1034986520</pqid></control><display><type>article</type><title>Stochastic resonance electrical stimulation to improve proprioception in knee osteoarthritis</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Collins, Amber T ; Blackburn, J. Troy ; Olcott, Chris W ; Miles, Jodie ; Jordan, Joanne ; Dirschl, Douglas R ; Weinhold, Paul S</creator><creatorcontrib>Collins, Amber T ; Blackburn, J. Troy ; Olcott, Chris W ; Miles, Jodie ; Jordan, Joanne ; Dirschl, Douglas R ; Weinhold, Paul S</creatorcontrib><description>Abstract Proprioceptive deficits occur with knee osteoarthritis (OA) and improving proprioception may slow joint degeneration by allowing more appropriate joint loading. Stochastic resonance (SR) stimulation improves balance and the sensitivity of specific mechanoreceptors. Our purpose was to evaluate the effects of SR electrical stimulation combined with a knee sleeve on proprioception in subjects with knee OA. Joint position sense (JPS) was measured in 38 subjects with knee OA during four conditions in both a partial weight-bearing (PWB) and non weight-bearing (NWB) task: no electrical stimulation/no sleeve, no electrical stimulation/sleeve, 50 μA-RMS stimulation/sleeve, and 75 μA-RMS stimulation/sleeve. Subjects also reported their knee pain, stiffness, functionality (WOMAC), and instability. Repeated measures ANOVA and Spearman correlations were performed to investigate differences between the conditions and relationships among the outcome measures. JPS during the 75 μA-RMS stimulation/sleeve and sleeve alone conditions was significantly improved compared to the control condition in the PWB task. However, the 75 μA-RMS stimulation/sleeve and the sleeve alone conditions did not differ from each other. A moderate correlation was found between the improvements with the 75 μA-RMS stimulation/sleeve condition compared to the JPS of the control condition in the PWB task. No differences in JPS were found between the four conditions in the NWB task. Significant correlations were found between the control JPS and WOMAC indices (p &lt; 0.005). Improved proprioception during the PWB task was achieved with a sleeve alone and in combination with SR stimulation. The observed correlations suggest that subjects with larger proprioceptive deficits may benefit most from these therapies.</description><identifier>ISSN: 0968-0160</identifier><identifier>EISSN: 1873-5800</identifier><identifier>DOI: 10.1016/j.knee.2010.07.001</identifier><identifier>PMID: 20655753</identifier><language>eng</language><publisher>Netherlands: Elsevier B.V</publisher><subject>Arthritis ; Braces ; Diabetic neuropathy ; Electric Stimulation Therapy - methods ; Exercise Therapy ; Female ; Humans ; Knee ; Knee Joint - physiopathology ; Male ; Middle Aged ; Older people ; Orthopedics ; Osteoarthritis ; Osteoarthritis, Knee - physiopathology ; Osteoarthritis, Knee - therapy ; Pain ; Personal relationships ; Proprioception ; Proprioception - physiology ; Sports injuries ; Stochastic Processes ; Stochastic resonance ; Treatment Outcome ; Weight-Bearing</subject><ispartof>The knee, 2011-10, Vol.18 (5), p.317-322</ispartof><rights>Elsevier B.V.</rights><rights>2010 Elsevier B.V.</rights><rights>Copyright © 2010 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c438t-94e40cfd1222779b80e1ead35482c8bf1d1f9f79b9e6359896abb1f3013bb4253</citedby><cites>FETCH-LOGICAL-c438t-94e40cfd1222779b80e1ead35482c8bf1d1f9f79b9e6359896abb1f3013bb4253</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.knee.2010.07.001$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,777,781,3537,27905,27906,45976</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20655753$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Collins, Amber T</creatorcontrib><creatorcontrib>Blackburn, J. Troy</creatorcontrib><creatorcontrib>Olcott, Chris W</creatorcontrib><creatorcontrib>Miles, Jodie</creatorcontrib><creatorcontrib>Jordan, Joanne</creatorcontrib><creatorcontrib>Dirschl, Douglas R</creatorcontrib><creatorcontrib>Weinhold, Paul S</creatorcontrib><title>Stochastic resonance electrical stimulation to improve proprioception in knee osteoarthritis</title><title>The knee</title><addtitle>Knee</addtitle><description>Abstract Proprioceptive deficits occur with knee osteoarthritis (OA) and improving proprioception may slow joint degeneration by allowing more appropriate joint loading. Stochastic resonance (SR) stimulation improves balance and the sensitivity of specific mechanoreceptors. Our purpose was to evaluate the effects of SR electrical stimulation combined with a knee sleeve on proprioception in subjects with knee OA. Joint position sense (JPS) was measured in 38 subjects with knee OA during four conditions in both a partial weight-bearing (PWB) and non weight-bearing (NWB) task: no electrical stimulation/no sleeve, no electrical stimulation/sleeve, 50 μA-RMS stimulation/sleeve, and 75 μA-RMS stimulation/sleeve. Subjects also reported their knee pain, stiffness, functionality (WOMAC), and instability. Repeated measures ANOVA and Spearman correlations were performed to investigate differences between the conditions and relationships among the outcome measures. JPS during the 75 μA-RMS stimulation/sleeve and sleeve alone conditions was significantly improved compared to the control condition in the PWB task. However, the 75 μA-RMS stimulation/sleeve and the sleeve alone conditions did not differ from each other. A moderate correlation was found between the improvements with the 75 μA-RMS stimulation/sleeve condition compared to the JPS of the control condition in the PWB task. No differences in JPS were found between the four conditions in the NWB task. Significant correlations were found between the control JPS and WOMAC indices (p &lt; 0.005). Improved proprioception during the PWB task was achieved with a sleeve alone and in combination with SR stimulation. The observed correlations suggest that subjects with larger proprioceptive deficits may benefit most from these therapies.</description><subject>Arthritis</subject><subject>Braces</subject><subject>Diabetic neuropathy</subject><subject>Electric Stimulation Therapy - methods</subject><subject>Exercise Therapy</subject><subject>Female</subject><subject>Humans</subject><subject>Knee</subject><subject>Knee Joint - physiopathology</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Older people</subject><subject>Orthopedics</subject><subject>Osteoarthritis</subject><subject>Osteoarthritis, Knee - physiopathology</subject><subject>Osteoarthritis, Knee - therapy</subject><subject>Pain</subject><subject>Personal relationships</subject><subject>Proprioception</subject><subject>Proprioception - physiology</subject><subject>Sports injuries</subject><subject>Stochastic Processes</subject><subject>Stochastic resonance</subject><subject>Treatment Outcome</subject><subject>Weight-Bearing</subject><issn>0968-0160</issn><issn>1873-5800</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kcFq3DAQhkVpaDZpX6CHYuihJ29GkiVLUAohtGkhkEPaW0HI8phoY1tbSQ7k7St30xZyyMUCz_cPM98Q8pbClgKVZ7vt3Yy4ZVB-QLsFoC_IhqqW10IBvCQb0FLVhYRjcpLSDgCkbsQrcsxACtEKviE_b3JwtzZl76qIKcx2dljhiC5H7-xYlcq0jDb7MFc5VH7ax3CPVfnuow8O938qfq7WWaqQMgYb82302afX5GiwY8I3j-8p-fHl8_eLr_XV9eW3i_Or2jVc5Vo32IAbesoYa1vdKUCKtueiUcypbqA9HfRQCholF1ppabuODhwo77qGCX5KPhz6lql-LZiymXxyOI52xrAko5TQoLnUhXz_hNyFJc5lOEOBN1pJwaBQ7EC5GFKKOJiy62TjQ4HMqt7szLquWdUbaE1RX0LvHlsv3YT9v8hf1wX4eACwqLj3GE1yHovu3sei2_TBP9__05O4G_283ugOHzD938MkZsDcrMdfb09hTVPJfwPbqqq9</recordid><startdate>20111001</startdate><enddate>20111001</enddate><creator>Collins, Amber T</creator><creator>Blackburn, J. Troy</creator><creator>Olcott, Chris W</creator><creator>Miles, Jodie</creator><creator>Jordan, Joanne</creator><creator>Dirschl, Douglas R</creator><creator>Weinhold, Paul S</creator><general>Elsevier B.V</general><general>Elsevier Limited</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QP</scope><scope>K9.</scope><scope>NAPCQ</scope><scope>7X8</scope></search><sort><creationdate>20111001</creationdate><title>Stochastic resonance electrical stimulation to improve proprioception in knee osteoarthritis</title><author>Collins, Amber T ; Blackburn, J. Troy ; Olcott, Chris W ; Miles, Jodie ; Jordan, Joanne ; Dirschl, Douglas R ; Weinhold, Paul S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c438t-94e40cfd1222779b80e1ead35482c8bf1d1f9f79b9e6359896abb1f3013bb4253</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Arthritis</topic><topic>Braces</topic><topic>Diabetic neuropathy</topic><topic>Electric Stimulation Therapy - methods</topic><topic>Exercise Therapy</topic><topic>Female</topic><topic>Humans</topic><topic>Knee</topic><topic>Knee Joint - physiopathology</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Older people</topic><topic>Orthopedics</topic><topic>Osteoarthritis</topic><topic>Osteoarthritis, Knee - physiopathology</topic><topic>Osteoarthritis, Knee - therapy</topic><topic>Pain</topic><topic>Personal relationships</topic><topic>Proprioception</topic><topic>Proprioception - physiology</topic><topic>Sports injuries</topic><topic>Stochastic Processes</topic><topic>Stochastic resonance</topic><topic>Treatment Outcome</topic><topic>Weight-Bearing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Collins, Amber T</creatorcontrib><creatorcontrib>Blackburn, J. Troy</creatorcontrib><creatorcontrib>Olcott, Chris W</creatorcontrib><creatorcontrib>Miles, Jodie</creatorcontrib><creatorcontrib>Jordan, Joanne</creatorcontrib><creatorcontrib>Dirschl, Douglas R</creatorcontrib><creatorcontrib>Weinhold, Paul S</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Calcium &amp; Calcified Tissue Abstracts</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>MEDLINE - Academic</collection><jtitle>The knee</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Collins, Amber T</au><au>Blackburn, J. Troy</au><au>Olcott, Chris W</au><au>Miles, Jodie</au><au>Jordan, Joanne</au><au>Dirschl, Douglas R</au><au>Weinhold, Paul S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Stochastic resonance electrical stimulation to improve proprioception in knee osteoarthritis</atitle><jtitle>The knee</jtitle><addtitle>Knee</addtitle><date>2011-10-01</date><risdate>2011</risdate><volume>18</volume><issue>5</issue><spage>317</spage><epage>322</epage><pages>317-322</pages><issn>0968-0160</issn><eissn>1873-5800</eissn><abstract>Abstract Proprioceptive deficits occur with knee osteoarthritis (OA) and improving proprioception may slow joint degeneration by allowing more appropriate joint loading. Stochastic resonance (SR) stimulation improves balance and the sensitivity of specific mechanoreceptors. Our purpose was to evaluate the effects of SR electrical stimulation combined with a knee sleeve on proprioception in subjects with knee OA. Joint position sense (JPS) was measured in 38 subjects with knee OA during four conditions in both a partial weight-bearing (PWB) and non weight-bearing (NWB) task: no electrical stimulation/no sleeve, no electrical stimulation/sleeve, 50 μA-RMS stimulation/sleeve, and 75 μA-RMS stimulation/sleeve. Subjects also reported their knee pain, stiffness, functionality (WOMAC), and instability. Repeated measures ANOVA and Spearman correlations were performed to investigate differences between the conditions and relationships among the outcome measures. JPS during the 75 μA-RMS stimulation/sleeve and sleeve alone conditions was significantly improved compared to the control condition in the PWB task. However, the 75 μA-RMS stimulation/sleeve and the sleeve alone conditions did not differ from each other. A moderate correlation was found between the improvements with the 75 μA-RMS stimulation/sleeve condition compared to the JPS of the control condition in the PWB task. No differences in JPS were found between the four conditions in the NWB task. Significant correlations were found between the control JPS and WOMAC indices (p &lt; 0.005). Improved proprioception during the PWB task was achieved with a sleeve alone and in combination with SR stimulation. The observed correlations suggest that subjects with larger proprioceptive deficits may benefit most from these therapies.</abstract><cop>Netherlands</cop><pub>Elsevier B.V</pub><pmid>20655753</pmid><doi>10.1016/j.knee.2010.07.001</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0968-0160
ispartof The knee, 2011-10, Vol.18 (5), p.317-322
issn 0968-0160
1873-5800
language eng
recordid cdi_proquest_miscellaneous_885909369
source MEDLINE; Elsevier ScienceDirect Journals
subjects Arthritis
Braces
Diabetic neuropathy
Electric Stimulation Therapy - methods
Exercise Therapy
Female
Humans
Knee
Knee Joint - physiopathology
Male
Middle Aged
Older people
Orthopedics
Osteoarthritis
Osteoarthritis, Knee - physiopathology
Osteoarthritis, Knee - therapy
Pain
Personal relationships
Proprioception
Proprioception - physiology
Sports injuries
Stochastic Processes
Stochastic resonance
Treatment Outcome
Weight-Bearing
title Stochastic resonance electrical stimulation to improve proprioception in knee osteoarthritis
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T02%3A10%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Stochastic%20resonance%20electrical%20stimulation%20to%20improve%20proprioception%20in%20knee%20osteoarthritis&rft.jtitle=The%20knee&rft.au=Collins,%20Amber%20T&rft.date=2011-10-01&rft.volume=18&rft.issue=5&rft.spage=317&rft.epage=322&rft.pages=317-322&rft.issn=0968-0160&rft.eissn=1873-5800&rft_id=info:doi/10.1016/j.knee.2010.07.001&rft_dat=%3Cproquest_cross%3E885909369%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1034986520&rft_id=info:pmid/20655753&rft_els_id=1_s2_0_S0968016010001316&rfr_iscdi=true