Dual-echo Dixon imaging with flexible choice of echo times

In this work, a new two‐point method for water–fat imaging is described and explored. It generalizes existing two‐point methods by eliminating some of the restrictions that these methods impose on the choice of echo times. Thus, the new two‐point method promises to provide more freedom in the select...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance in medicine 2011-01, Vol.65 (1), p.96-107
Hauptverfasser: Eggers, Holger, Brendel, Bernhard, Duijndam, Adri, Herigault, Gwenael
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 107
container_issue 1
container_start_page 96
container_title Magnetic resonance in medicine
container_volume 65
creator Eggers, Holger
Brendel, Bernhard
Duijndam, Adri
Herigault, Gwenael
description In this work, a new two‐point method for water–fat imaging is described and explored. It generalizes existing two‐point methods by eliminating some of the restrictions that these methods impose on the choice of echo times. Thus, the new two‐point method promises to provide more freedom in the selection of protocol parameters and to reach higher scan efficiency. Its performance was studied theoretically and was evaluated experimentally in abdominal imaging with a multigradient‐echo sequence. While depending on the choice of echo times, it is generally found to be favorable compared to existing two‐point methods. Notably, water images with higher spatial resolution and better signal‐to‐noise ratio were attained with it in single breathholds at 3.0 T and 1.5 T, respectively. The use of more accurate spectral models of fat is shown to substantially reduce observed variations in the extent of fat suppression. The acquisition of in‐ and opposed‐phase images is demonstrated to be replaceable by a synthesis from water and fat images. The new two‐point method is finally also applied to autocalibrate a multidimensional eddy current correction and to enhance the fat suppression achieved with three‐point methods in this way, especially toward the edges of larger field of views. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
doi_str_mv 10.1002/mrm.22578
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_883041681</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>883041681</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4578-73885ea4b198b3fd8d6d2739b9d73772cbf48e05b46503b1e5790eebe5abfc7d3</originalsourceid><addsrcrecordid>eNqFkMtKAzEUQIMoWh8Lf0AGXIiL0TwnGXfa-sLWF4rgJkxm7rSp86iTDta_N7XqQhBXIeTcQ-5BaJvgA4IxPSyb8oBSIdUS6hBBaUhFzJdRB0uOQ0ZivobWnRtjjONY8lW0RrGK_C3qoKNemxQhpKM66NlZXQW2TIa2GgZvdjoK8gJm1hQQ-HebQlDnwSc6tSW4TbSSJ4WDra9zAz2enT50L8L-zfll97gfptx_KZRMKQEJNyRWhuWZyqKMShabOJNMSpqanCvAwvBIYGYICBljAAMiMXkqM7aB9hbeSVO_tuCmurQuhaJIKqhbp5VimJNIkf9JiqVSnGJP7v4ix3XbVH4NTeY-SSib-_YXVNrUzjWQ60nj-zTvmmA9L699ef1Z3rM7X8bWlJD9kN-pPXC4AN5sAe9_m_TgfvCtDBcT1k1h9jORNC868umEfro-13cn91f9O3qrn9kHBUuaAw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1883071231</pqid></control><display><type>article</type><title>Dual-echo Dixon imaging with flexible choice of echo times</title><source>Wiley Free Content</source><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><creator>Eggers, Holger ; Brendel, Bernhard ; Duijndam, Adri ; Herigault, Gwenael</creator><creatorcontrib>Eggers, Holger ; Brendel, Bernhard ; Duijndam, Adri ; Herigault, Gwenael</creatorcontrib><description>In this work, a new two‐point method for water–fat imaging is described and explored. It generalizes existing two‐point methods by eliminating some of the restrictions that these methods impose on the choice of echo times. Thus, the new two‐point method promises to provide more freedom in the selection of protocol parameters and to reach higher scan efficiency. Its performance was studied theoretically and was evaluated experimentally in abdominal imaging with a multigradient‐echo sequence. While depending on the choice of echo times, it is generally found to be favorable compared to existing two‐point methods. Notably, water images with higher spatial resolution and better signal‐to‐noise ratio were attained with it in single breathholds at 3.0 T and 1.5 T, respectively. The use of more accurate spectral models of fat is shown to substantially reduce observed variations in the extent of fat suppression. The acquisition of in‐ and opposed‐phase images is demonstrated to be replaceable by a synthesis from water and fat images. The new two‐point method is finally also applied to autocalibrate a multidimensional eddy current correction and to enhance the fat suppression achieved with three‐point methods in this way, especially toward the edges of larger field of views. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.</description><identifier>ISSN: 0740-3194</identifier><identifier>ISSN: 1522-2594</identifier><identifier>EISSN: 1522-2594</identifier><identifier>DOI: 10.1002/mrm.22578</identifier><identifier>PMID: 20860006</identifier><identifier>CODEN: MRMEEN</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>abdominal imaging ; Adipose Tissue - anatomy &amp; histology ; Algorithms ; Dixon methods ; Echo-Planar Imaging - methods ; eddy currents ; fat suppression ; Humans ; Image Enhancement - methods ; Image Interpretation, Computer-Assisted - methods ; multiecho acquisitions ; Reproducibility of Results ; Sensitivity and Specificity ; Subtraction Technique ; Water - analysis ; water-fat separation</subject><ispartof>Magnetic resonance in medicine, 2011-01, Vol.65 (1), p.96-107</ispartof><rights>Copyright © 2010 Wiley‐Liss, Inc.</rights><rights>2010 Wiley-Liss, Inc.</rights><rights>Copyright © 2010 Wiley-Liss, Inc.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4578-73885ea4b198b3fd8d6d2739b9d73772cbf48e05b46503b1e5790eebe5abfc7d3</citedby><cites>FETCH-LOGICAL-c4578-73885ea4b198b3fd8d6d2739b9d73772cbf48e05b46503b1e5790eebe5abfc7d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fmrm.22578$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fmrm.22578$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,1427,27901,27902,45550,45551,46384,46808</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20860006$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Eggers, Holger</creatorcontrib><creatorcontrib>Brendel, Bernhard</creatorcontrib><creatorcontrib>Duijndam, Adri</creatorcontrib><creatorcontrib>Herigault, Gwenael</creatorcontrib><title>Dual-echo Dixon imaging with flexible choice of echo times</title><title>Magnetic resonance in medicine</title><addtitle>Magn. Reson. Med</addtitle><description>In this work, a new two‐point method for water–fat imaging is described and explored. It generalizes existing two‐point methods by eliminating some of the restrictions that these methods impose on the choice of echo times. Thus, the new two‐point method promises to provide more freedom in the selection of protocol parameters and to reach higher scan efficiency. Its performance was studied theoretically and was evaluated experimentally in abdominal imaging with a multigradient‐echo sequence. While depending on the choice of echo times, it is generally found to be favorable compared to existing two‐point methods. Notably, water images with higher spatial resolution and better signal‐to‐noise ratio were attained with it in single breathholds at 3.0 T and 1.5 T, respectively. The use of more accurate spectral models of fat is shown to substantially reduce observed variations in the extent of fat suppression. The acquisition of in‐ and opposed‐phase images is demonstrated to be replaceable by a synthesis from water and fat images. The new two‐point method is finally also applied to autocalibrate a multidimensional eddy current correction and to enhance the fat suppression achieved with three‐point methods in this way, especially toward the edges of larger field of views. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.</description><subject>abdominal imaging</subject><subject>Adipose Tissue - anatomy &amp; histology</subject><subject>Algorithms</subject><subject>Dixon methods</subject><subject>Echo-Planar Imaging - methods</subject><subject>eddy currents</subject><subject>fat suppression</subject><subject>Humans</subject><subject>Image Enhancement - methods</subject><subject>Image Interpretation, Computer-Assisted - methods</subject><subject>multiecho acquisitions</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><subject>Subtraction Technique</subject><subject>Water - analysis</subject><subject>water-fat separation</subject><issn>0740-3194</issn><issn>1522-2594</issn><issn>1522-2594</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkMtKAzEUQIMoWh8Lf0AGXIiL0TwnGXfa-sLWF4rgJkxm7rSp86iTDta_N7XqQhBXIeTcQ-5BaJvgA4IxPSyb8oBSIdUS6hBBaUhFzJdRB0uOQ0ZivobWnRtjjONY8lW0RrGK_C3qoKNemxQhpKM66NlZXQW2TIa2GgZvdjoK8gJm1hQQ-HebQlDnwSc6tSW4TbSSJ4WDra9zAz2enT50L8L-zfll97gfptx_KZRMKQEJNyRWhuWZyqKMShabOJNMSpqanCvAwvBIYGYICBljAAMiMXkqM7aB9hbeSVO_tuCmurQuhaJIKqhbp5VimJNIkf9JiqVSnGJP7v4ix3XbVH4NTeY-SSib-_YXVNrUzjWQ60nj-zTvmmA9L699ef1Z3rM7X8bWlJD9kN-pPXC4AN5sAe9_m_TgfvCtDBcT1k1h9jORNC868umEfro-13cn91f9O3qrn9kHBUuaAw</recordid><startdate>201101</startdate><enddate>201101</enddate><creator>Eggers, Holger</creator><creator>Brendel, Bernhard</creator><creator>Duijndam, Adri</creator><creator>Herigault, Gwenael</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><general>Wiley Subscription Services, Inc</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>FR3</scope><scope>K9.</scope><scope>M7Z</scope><scope>P64</scope><scope>7X8</scope><scope>7QO</scope></search><sort><creationdate>201101</creationdate><title>Dual-echo Dixon imaging with flexible choice of echo times</title><author>Eggers, Holger ; Brendel, Bernhard ; Duijndam, Adri ; Herigault, Gwenael</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4578-73885ea4b198b3fd8d6d2739b9d73772cbf48e05b46503b1e5790eebe5abfc7d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>abdominal imaging</topic><topic>Adipose Tissue - anatomy &amp; histology</topic><topic>Algorithms</topic><topic>Dixon methods</topic><topic>Echo-Planar Imaging - methods</topic><topic>eddy currents</topic><topic>fat suppression</topic><topic>Humans</topic><topic>Image Enhancement - methods</topic><topic>Image Interpretation, Computer-Assisted - methods</topic><topic>multiecho acquisitions</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><topic>Subtraction Technique</topic><topic>Water - analysis</topic><topic>water-fat separation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Eggers, Holger</creatorcontrib><creatorcontrib>Brendel, Bernhard</creatorcontrib><creatorcontrib>Duijndam, Adri</creatorcontrib><creatorcontrib>Herigault, Gwenael</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Biochemistry Abstracts 1</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><collection>Biotechnology Research Abstracts</collection><jtitle>Magnetic resonance in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Eggers, Holger</au><au>Brendel, Bernhard</au><au>Duijndam, Adri</au><au>Herigault, Gwenael</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dual-echo Dixon imaging with flexible choice of echo times</atitle><jtitle>Magnetic resonance in medicine</jtitle><addtitle>Magn. Reson. Med</addtitle><date>2011-01</date><risdate>2011</risdate><volume>65</volume><issue>1</issue><spage>96</spage><epage>107</epage><pages>96-107</pages><issn>0740-3194</issn><issn>1522-2594</issn><eissn>1522-2594</eissn><coden>MRMEEN</coden><abstract>In this work, a new two‐point method for water–fat imaging is described and explored. It generalizes existing two‐point methods by eliminating some of the restrictions that these methods impose on the choice of echo times. Thus, the new two‐point method promises to provide more freedom in the selection of protocol parameters and to reach higher scan efficiency. Its performance was studied theoretically and was evaluated experimentally in abdominal imaging with a multigradient‐echo sequence. While depending on the choice of echo times, it is generally found to be favorable compared to existing two‐point methods. Notably, water images with higher spatial resolution and better signal‐to‐noise ratio were attained with it in single breathholds at 3.0 T and 1.5 T, respectively. The use of more accurate spectral models of fat is shown to substantially reduce observed variations in the extent of fat suppression. The acquisition of in‐ and opposed‐phase images is demonstrated to be replaceable by a synthesis from water and fat images. The new two‐point method is finally also applied to autocalibrate a multidimensional eddy current correction and to enhance the fat suppression achieved with three‐point methods in this way, especially toward the edges of larger field of views. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>20860006</pmid><doi>10.1002/mrm.22578</doi><tpages>12</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0740-3194
ispartof Magnetic resonance in medicine, 2011-01, Vol.65 (1), p.96-107
issn 0740-3194
1522-2594
1522-2594
language eng
recordid cdi_proquest_miscellaneous_883041681
source Wiley Free Content; MEDLINE; Wiley Online Library Journals Frontfile Complete
subjects abdominal imaging
Adipose Tissue - anatomy & histology
Algorithms
Dixon methods
Echo-Planar Imaging - methods
eddy currents
fat suppression
Humans
Image Enhancement - methods
Image Interpretation, Computer-Assisted - methods
multiecho acquisitions
Reproducibility of Results
Sensitivity and Specificity
Subtraction Technique
Water - analysis
water-fat separation
title Dual-echo Dixon imaging with flexible choice of echo times
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T07%3A15%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dual-echo%20Dixon%20imaging%20with%20flexible%20choice%20of%20echo%20times&rft.jtitle=Magnetic%20resonance%20in%20medicine&rft.au=Eggers,%20Holger&rft.date=2011-01&rft.volume=65&rft.issue=1&rft.spage=96&rft.epage=107&rft.pages=96-107&rft.issn=0740-3194&rft.eissn=1522-2594&rft.coden=MRMEEN&rft_id=info:doi/10.1002/mrm.22578&rft_dat=%3Cproquest_cross%3E883041681%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1883071231&rft_id=info:pmid/20860006&rfr_iscdi=true