Dual-echo Dixon imaging with flexible choice of echo times
In this work, a new two‐point method for water–fat imaging is described and explored. It generalizes existing two‐point methods by eliminating some of the restrictions that these methods impose on the choice of echo times. Thus, the new two‐point method promises to provide more freedom in the select...
Gespeichert in:
Veröffentlicht in: | Magnetic resonance in medicine 2011-01, Vol.65 (1), p.96-107 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 107 |
---|---|
container_issue | 1 |
container_start_page | 96 |
container_title | Magnetic resonance in medicine |
container_volume | 65 |
creator | Eggers, Holger Brendel, Bernhard Duijndam, Adri Herigault, Gwenael |
description | In this work, a new two‐point method for water–fat imaging is described and explored. It generalizes existing two‐point methods by eliminating some of the restrictions that these methods impose on the choice of echo times. Thus, the new two‐point method promises to provide more freedom in the selection of protocol parameters and to reach higher scan efficiency. Its performance was studied theoretically and was evaluated experimentally in abdominal imaging with a multigradient‐echo sequence. While depending on the choice of echo times, it is generally found to be favorable compared to existing two‐point methods. Notably, water images with higher spatial resolution and better signal‐to‐noise ratio were attained with it in single breathholds at 3.0 T and 1.5 T, respectively. The use of more accurate spectral models of fat is shown to substantially reduce observed variations in the extent of fat suppression. The acquisition of in‐ and opposed‐phase images is demonstrated to be replaceable by a synthesis from water and fat images. The new two‐point method is finally also applied to autocalibrate a multidimensional eddy current correction and to enhance the fat suppression achieved with three‐point methods in this way, especially toward the edges of larger field of views. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc. |
doi_str_mv | 10.1002/mrm.22578 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_883041681</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>883041681</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4578-73885ea4b198b3fd8d6d2739b9d73772cbf48e05b46503b1e5790eebe5abfc7d3</originalsourceid><addsrcrecordid>eNqFkMtKAzEUQIMoWh8Lf0AGXIiL0TwnGXfa-sLWF4rgJkxm7rSp86iTDta_N7XqQhBXIeTcQ-5BaJvgA4IxPSyb8oBSIdUS6hBBaUhFzJdRB0uOQ0ZivobWnRtjjONY8lW0RrGK_C3qoKNemxQhpKM66NlZXQW2TIa2GgZvdjoK8gJm1hQQ-HebQlDnwSc6tSW4TbSSJ4WDra9zAz2enT50L8L-zfll97gfptx_KZRMKQEJNyRWhuWZyqKMShabOJNMSpqanCvAwvBIYGYICBljAAMiMXkqM7aB9hbeSVO_tuCmurQuhaJIKqhbp5VimJNIkf9JiqVSnGJP7v4ix3XbVH4NTeY-SSib-_YXVNrUzjWQ60nj-zTvmmA9L699ef1Z3rM7X8bWlJD9kN-pPXC4AN5sAe9_m_TgfvCtDBcT1k1h9jORNC868umEfro-13cn91f9O3qrn9kHBUuaAw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1883071231</pqid></control><display><type>article</type><title>Dual-echo Dixon imaging with flexible choice of echo times</title><source>Wiley Free Content</source><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><creator>Eggers, Holger ; Brendel, Bernhard ; Duijndam, Adri ; Herigault, Gwenael</creator><creatorcontrib>Eggers, Holger ; Brendel, Bernhard ; Duijndam, Adri ; Herigault, Gwenael</creatorcontrib><description>In this work, a new two‐point method for water–fat imaging is described and explored. It generalizes existing two‐point methods by eliminating some of the restrictions that these methods impose on the choice of echo times. Thus, the new two‐point method promises to provide more freedom in the selection of protocol parameters and to reach higher scan efficiency. Its performance was studied theoretically and was evaluated experimentally in abdominal imaging with a multigradient‐echo sequence. While depending on the choice of echo times, it is generally found to be favorable compared to existing two‐point methods. Notably, water images with higher spatial resolution and better signal‐to‐noise ratio were attained with it in single breathholds at 3.0 T and 1.5 T, respectively. The use of more accurate spectral models of fat is shown to substantially reduce observed variations in the extent of fat suppression. The acquisition of in‐ and opposed‐phase images is demonstrated to be replaceable by a synthesis from water and fat images. The new two‐point method is finally also applied to autocalibrate a multidimensional eddy current correction and to enhance the fat suppression achieved with three‐point methods in this way, especially toward the edges of larger field of views. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.</description><identifier>ISSN: 0740-3194</identifier><identifier>ISSN: 1522-2594</identifier><identifier>EISSN: 1522-2594</identifier><identifier>DOI: 10.1002/mrm.22578</identifier><identifier>PMID: 20860006</identifier><identifier>CODEN: MRMEEN</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>abdominal imaging ; Adipose Tissue - anatomy & histology ; Algorithms ; Dixon methods ; Echo-Planar Imaging - methods ; eddy currents ; fat suppression ; Humans ; Image Enhancement - methods ; Image Interpretation, Computer-Assisted - methods ; multiecho acquisitions ; Reproducibility of Results ; Sensitivity and Specificity ; Subtraction Technique ; Water - analysis ; water-fat separation</subject><ispartof>Magnetic resonance in medicine, 2011-01, Vol.65 (1), p.96-107</ispartof><rights>Copyright © 2010 Wiley‐Liss, Inc.</rights><rights>2010 Wiley-Liss, Inc.</rights><rights>Copyright © 2010 Wiley-Liss, Inc.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4578-73885ea4b198b3fd8d6d2739b9d73772cbf48e05b46503b1e5790eebe5abfc7d3</citedby><cites>FETCH-LOGICAL-c4578-73885ea4b198b3fd8d6d2739b9d73772cbf48e05b46503b1e5790eebe5abfc7d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fmrm.22578$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fmrm.22578$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,1427,27901,27902,45550,45551,46384,46808</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/20860006$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Eggers, Holger</creatorcontrib><creatorcontrib>Brendel, Bernhard</creatorcontrib><creatorcontrib>Duijndam, Adri</creatorcontrib><creatorcontrib>Herigault, Gwenael</creatorcontrib><title>Dual-echo Dixon imaging with flexible choice of echo times</title><title>Magnetic resonance in medicine</title><addtitle>Magn. Reson. Med</addtitle><description>In this work, a new two‐point method for water–fat imaging is described and explored. It generalizes existing two‐point methods by eliminating some of the restrictions that these methods impose on the choice of echo times. Thus, the new two‐point method promises to provide more freedom in the selection of protocol parameters and to reach higher scan efficiency. Its performance was studied theoretically and was evaluated experimentally in abdominal imaging with a multigradient‐echo sequence. While depending on the choice of echo times, it is generally found to be favorable compared to existing two‐point methods. Notably, water images with higher spatial resolution and better signal‐to‐noise ratio were attained with it in single breathholds at 3.0 T and 1.5 T, respectively. The use of more accurate spectral models of fat is shown to substantially reduce observed variations in the extent of fat suppression. The acquisition of in‐ and opposed‐phase images is demonstrated to be replaceable by a synthesis from water and fat images. The new two‐point method is finally also applied to autocalibrate a multidimensional eddy current correction and to enhance the fat suppression achieved with three‐point methods in this way, especially toward the edges of larger field of views. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.</description><subject>abdominal imaging</subject><subject>Adipose Tissue - anatomy & histology</subject><subject>Algorithms</subject><subject>Dixon methods</subject><subject>Echo-Planar Imaging - methods</subject><subject>eddy currents</subject><subject>fat suppression</subject><subject>Humans</subject><subject>Image Enhancement - methods</subject><subject>Image Interpretation, Computer-Assisted - methods</subject><subject>multiecho acquisitions</subject><subject>Reproducibility of Results</subject><subject>Sensitivity and Specificity</subject><subject>Subtraction Technique</subject><subject>Water - analysis</subject><subject>water-fat separation</subject><issn>0740-3194</issn><issn>1522-2594</issn><issn>1522-2594</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkMtKAzEUQIMoWh8Lf0AGXIiL0TwnGXfa-sLWF4rgJkxm7rSp86iTDta_N7XqQhBXIeTcQ-5BaJvgA4IxPSyb8oBSIdUS6hBBaUhFzJdRB0uOQ0ZivobWnRtjjONY8lW0RrGK_C3qoKNemxQhpKM66NlZXQW2TIa2GgZvdjoK8gJm1hQQ-HebQlDnwSc6tSW4TbSSJ4WDra9zAz2enT50L8L-zfll97gfptx_KZRMKQEJNyRWhuWZyqKMShabOJNMSpqanCvAwvBIYGYICBljAAMiMXkqM7aB9hbeSVO_tuCmurQuhaJIKqhbp5VimJNIkf9JiqVSnGJP7v4ix3XbVH4NTeY-SSib-_YXVNrUzjWQ60nj-zTvmmA9L699ef1Z3rM7X8bWlJD9kN-pPXC4AN5sAe9_m_TgfvCtDBcT1k1h9jORNC868umEfro-13cn91f9O3qrn9kHBUuaAw</recordid><startdate>201101</startdate><enddate>201101</enddate><creator>Eggers, Holger</creator><creator>Brendel, Bernhard</creator><creator>Duijndam, Adri</creator><creator>Herigault, Gwenael</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><general>Wiley Subscription Services, Inc</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>FR3</scope><scope>K9.</scope><scope>M7Z</scope><scope>P64</scope><scope>7X8</scope><scope>7QO</scope></search><sort><creationdate>201101</creationdate><title>Dual-echo Dixon imaging with flexible choice of echo times</title><author>Eggers, Holger ; Brendel, Bernhard ; Duijndam, Adri ; Herigault, Gwenael</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4578-73885ea4b198b3fd8d6d2739b9d73772cbf48e05b46503b1e5790eebe5abfc7d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>abdominal imaging</topic><topic>Adipose Tissue - anatomy & histology</topic><topic>Algorithms</topic><topic>Dixon methods</topic><topic>Echo-Planar Imaging - methods</topic><topic>eddy currents</topic><topic>fat suppression</topic><topic>Humans</topic><topic>Image Enhancement - methods</topic><topic>Image Interpretation, Computer-Assisted - methods</topic><topic>multiecho acquisitions</topic><topic>Reproducibility of Results</topic><topic>Sensitivity and Specificity</topic><topic>Subtraction Technique</topic><topic>Water - analysis</topic><topic>water-fat separation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Eggers, Holger</creatorcontrib><creatorcontrib>Brendel, Bernhard</creatorcontrib><creatorcontrib>Duijndam, Adri</creatorcontrib><creatorcontrib>Herigault, Gwenael</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Biochemistry Abstracts 1</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><collection>Biotechnology Research Abstracts</collection><jtitle>Magnetic resonance in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Eggers, Holger</au><au>Brendel, Bernhard</au><au>Duijndam, Adri</au><au>Herigault, Gwenael</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dual-echo Dixon imaging with flexible choice of echo times</atitle><jtitle>Magnetic resonance in medicine</jtitle><addtitle>Magn. Reson. Med</addtitle><date>2011-01</date><risdate>2011</risdate><volume>65</volume><issue>1</issue><spage>96</spage><epage>107</epage><pages>96-107</pages><issn>0740-3194</issn><issn>1522-2594</issn><eissn>1522-2594</eissn><coden>MRMEEN</coden><abstract>In this work, a new two‐point method for water–fat imaging is described and explored. It generalizes existing two‐point methods by eliminating some of the restrictions that these methods impose on the choice of echo times. Thus, the new two‐point method promises to provide more freedom in the selection of protocol parameters and to reach higher scan efficiency. Its performance was studied theoretically and was evaluated experimentally in abdominal imaging with a multigradient‐echo sequence. While depending on the choice of echo times, it is generally found to be favorable compared to existing two‐point methods. Notably, water images with higher spatial resolution and better signal‐to‐noise ratio were attained with it in single breathholds at 3.0 T and 1.5 T, respectively. The use of more accurate spectral models of fat is shown to substantially reduce observed variations in the extent of fat suppression. The acquisition of in‐ and opposed‐phase images is demonstrated to be replaceable by a synthesis from water and fat images. The new two‐point method is finally also applied to autocalibrate a multidimensional eddy current correction and to enhance the fat suppression achieved with three‐point methods in this way, especially toward the edges of larger field of views. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>20860006</pmid><doi>10.1002/mrm.22578</doi><tpages>12</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0740-3194 |
ispartof | Magnetic resonance in medicine, 2011-01, Vol.65 (1), p.96-107 |
issn | 0740-3194 1522-2594 1522-2594 |
language | eng |
recordid | cdi_proquest_miscellaneous_883041681 |
source | Wiley Free Content; MEDLINE; Wiley Online Library Journals Frontfile Complete |
subjects | abdominal imaging Adipose Tissue - anatomy & histology Algorithms Dixon methods Echo-Planar Imaging - methods eddy currents fat suppression Humans Image Enhancement - methods Image Interpretation, Computer-Assisted - methods multiecho acquisitions Reproducibility of Results Sensitivity and Specificity Subtraction Technique Water - analysis water-fat separation |
title | Dual-echo Dixon imaging with flexible choice of echo times |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T07%3A15%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dual-echo%20Dixon%20imaging%20with%20flexible%20choice%20of%20echo%20times&rft.jtitle=Magnetic%20resonance%20in%20medicine&rft.au=Eggers,%20Holger&rft.date=2011-01&rft.volume=65&rft.issue=1&rft.spage=96&rft.epage=107&rft.pages=96-107&rft.issn=0740-3194&rft.eissn=1522-2594&rft.coden=MRMEEN&rft_id=info:doi/10.1002/mrm.22578&rft_dat=%3Cproquest_cross%3E883041681%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1883071231&rft_id=info:pmid/20860006&rfr_iscdi=true |