Dynamic nonlinearity of lung tissue: frequency dependence and harmonic distortion

Harmonic distortion (HD) is a simple approach to analyze lung tissue nonlinear phenomena. This study aimed to characterize frequency-dependent behavior of HD at several amplitudes in lung tissue strips from healthy rats and its influence on the parameters of linear analysis. Lung strips (n = 17) wer...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of applied physiology (1985) 2011-08, Vol.111 (2), p.420-426
Hauptverfasser: ROMERO, Pablo V, FAFFE, Debora S, CANETE, Concepción
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Harmonic distortion (HD) is a simple approach to analyze lung tissue nonlinear phenomena. This study aimed to characterize frequency-dependent behavior of HD at several amplitudes in lung tissue strips from healthy rats and its influence on the parameters of linear analysis. Lung strips (n = 17) were subjected to sinusoidal deformation at three different strain amplitudes (Δε) and fixed operational stress (12 hPa) among various frequencies, between 0.03 and 3 Hz. Input HD was
ISSN:8750-7587
1522-1601