Experimental study and constitutive modelling of the passive mechanical properties of the porcine carotid artery and its relation to histological analysis: Implications in animal cardiovascular device trials

Abstract The present study focusses on the determination, comparison and constitutive modelling of the passive mechanical properties of the swine carotid artery over very long stretches in both proximal and distal regions. Special attention is paid to the histological and mechanical variations of th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical engineering & physics 2011-07, Vol.33 (6), p.665-676
Hauptverfasser: García, A, Peña, E, Laborda, A, Lostalé, F, De Gregorio, M.A, Doblaré, M, Martínez, M.A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 676
container_issue 6
container_start_page 665
container_title Medical engineering & physics
container_volume 33
creator García, A
Peña, E
Laborda, A
Lostalé, F
De Gregorio, M.A
Doblaré, M
Martínez, M.A
description Abstract The present study focusses on the determination, comparison and constitutive modelling of the passive mechanical properties of the swine carotid artery over very long stretches in both proximal and distal regions. Special attention is paid to the histological and mechanical variations of these properties depending on the proximity to the heart. The results can have clinical relevance, especially in the research field of intravascular device design. Before the final clinical trials on humans, research in the vascular area is conducted on animal models, swine being the most common due to the similarities between the human and swine cardiovascular systems as well as the fact that the swine size is suitable for testing devices, in this case endovascular carotid systems. The design of devices usually involves numerical techniques, and an important feature is the appropriate modelling of the mechanical properties of the vessel. Fourteen carotid swine arteries were harvested just after sacrifice and cyclic uniaxial tension tests in longitudinal and circumferential directions were performed for distal and proximal samples. The stress–stretch curves obtained were fitted with a hyperelastic anisotropic model. Stress-free configuration states were also analyzed. Finally, human and swine samples were processed in a histological laboratory and images were used to quantify their microconstituents. The statistical analysis revealed significant differences between the mechanical behavior of proximal and distal locations in the circumferential but not in the longitudinal direction. Circumferential direction samples show clear differences both in residual stretches and tensile curves between the two locations, while the features of longitudinal specimens are independent of the axial position. The statistical analysis provides significant evidence of changes depending on the position of the sample, mainly in elastin and SMC quantification.
doi_str_mv 10.1016/j.medengphy.2011.01.016
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_876239944</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S1350453311000415</els_id><sourcerecordid>874019924</sourcerecordid><originalsourceid>FETCH-LOGICAL-c487t-2fa52da48e080719fe7bbedc673bc42d18685597aecb7cab69a171353d58dd9d3</originalsourceid><addsrcrecordid>eNqNks1uEzEUhUcIREvgFcAbxCrBHs8vC6SqKlCpEgtgbXnsO8kNE3vw9UTNU_JKeJoQJFaVLNmyv3tsn3Oz7I3gK8FF9X672oEFtx43h1XOhVjxeVRPskvR1HJZcMmfprUs-bIopbzIXhBtOedFUcnn2UUuZC3avL3Mft_cjxBwBy7qgVGc7IFpZ5nxjiLGKeIe2M5bGAZ0a-Z7FjfARk30cABmox2aVDoGn4QiAp0hHww6YEYHH9EyHSKEozpGYgEGHdE7Fj3bIEU_-PWDknZ6OBDSB3a7G4e0NVPE0KUT3CUgCVr0e01mGnRgFvZogMWAeqCX2bM-TfDqNC-yH59uvl9_Wd59_Xx7fXW3NEVTx2Xe6zK3umiANzxZ0UPddWBNVcvOFLkVTdWUZVtrMF1tdFe1WtTJTmnLxtrWykX27qib_v1rAopqh2SSS9qBn0g1dZXLti2KR5AFF22bz2R9JE3wRAF6NaZkdDgowdUcu9qqc-xqjl3xeVSp8vXpjqlLxLnub84JeHsCkmt66IN2BukfV0jelunzi-zqyEHybo8QFBkEZ8BiABOV9fiIx3z8T8Ok3pmj_QkHoK2fQkqYlFCUK66-zV06N6kQc4OKUv4B5fvrlQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>874019924</pqid></control><display><type>article</type><title>Experimental study and constitutive modelling of the passive mechanical properties of the porcine carotid artery and its relation to histological analysis: Implications in animal cardiovascular device trials</title><source>MEDLINE</source><source>ScienceDirect Journals (5 years ago - present)</source><creator>García, A ; Peña, E ; Laborda, A ; Lostalé, F ; De Gregorio, M.A ; Doblaré, M ; Martínez, M.A</creator><creatorcontrib>García, A ; Peña, E ; Laborda, A ; Lostalé, F ; De Gregorio, M.A ; Doblaré, M ; Martínez, M.A</creatorcontrib><description>Abstract The present study focusses on the determination, comparison and constitutive modelling of the passive mechanical properties of the swine carotid artery over very long stretches in both proximal and distal regions. Special attention is paid to the histological and mechanical variations of these properties depending on the proximity to the heart. The results can have clinical relevance, especially in the research field of intravascular device design. Before the final clinical trials on humans, research in the vascular area is conducted on animal models, swine being the most common due to the similarities between the human and swine cardiovascular systems as well as the fact that the swine size is suitable for testing devices, in this case endovascular carotid systems. The design of devices usually involves numerical techniques, and an important feature is the appropriate modelling of the mechanical properties of the vessel. Fourteen carotid swine arteries were harvested just after sacrifice and cyclic uniaxial tension tests in longitudinal and circumferential directions were performed for distal and proximal samples. The stress–stretch curves obtained were fitted with a hyperelastic anisotropic model. Stress-free configuration states were also analyzed. Finally, human and swine samples were processed in a histological laboratory and images were used to quantify their microconstituents. The statistical analysis revealed significant differences between the mechanical behavior of proximal and distal locations in the circumferential but not in the longitudinal direction. Circumferential direction samples show clear differences both in residual stretches and tensile curves between the two locations, while the features of longitudinal specimens are independent of the axial position. The statistical analysis provides significant evidence of changes depending on the position of the sample, mainly in elastin and SMC quantification.</description><identifier>ISSN: 1350-4533</identifier><identifier>EISSN: 1873-4030</identifier><identifier>DOI: 10.1016/j.medengphy.2011.01.016</identifier><identifier>PMID: 21371929</identifier><language>eng</language><publisher>Kidlington: Elsevier Ltd</publisher><subject>Animals ; Anisotropy ; Biological and medical sciences ; Blood vessels and receptors ; Carotid Arteries - pathology ; Carotid Arteries - physiology ; Carotid Arteries - ultrastructure ; Carotid Artery, Common - pathology ; Carotid Artery, Common - physiology ; Computer Simulation ; Constitutive model ; Data fitting ; Data Interpretation, Statistical ; Elastic Modulus ; Elasticity ; Female ; Fundamental and applied biological sciences. Psychology ; Humans ; Microscopy ; Models, Animal ; Models, Cardiovascular ; Muscular and elastic artery ; Radiology ; Stress, Mechanical ; Stress–stretch relation ; Swine ; Vertebrates: cardiovascular system</subject><ispartof>Medical engineering &amp; physics, 2011-07, Vol.33 (6), p.665-676</ispartof><rights>IPEM</rights><rights>2011 IPEM</rights><rights>2015 INIST-CNRS</rights><rights>Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c487t-2fa52da48e080719fe7bbedc673bc42d18685597aecb7cab69a171353d58dd9d3</citedby><cites>FETCH-LOGICAL-c487t-2fa52da48e080719fe7bbedc673bc42d18685597aecb7cab69a171353d58dd9d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.medengphy.2011.01.016$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,780,784,3550,27924,27925,45995</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=24309567$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21371929$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>García, A</creatorcontrib><creatorcontrib>Peña, E</creatorcontrib><creatorcontrib>Laborda, A</creatorcontrib><creatorcontrib>Lostalé, F</creatorcontrib><creatorcontrib>De Gregorio, M.A</creatorcontrib><creatorcontrib>Doblaré, M</creatorcontrib><creatorcontrib>Martínez, M.A</creatorcontrib><title>Experimental study and constitutive modelling of the passive mechanical properties of the porcine carotid artery and its relation to histological analysis: Implications in animal cardiovascular device trials</title><title>Medical engineering &amp; physics</title><addtitle>Med Eng Phys</addtitle><description>Abstract The present study focusses on the determination, comparison and constitutive modelling of the passive mechanical properties of the swine carotid artery over very long stretches in both proximal and distal regions. Special attention is paid to the histological and mechanical variations of these properties depending on the proximity to the heart. The results can have clinical relevance, especially in the research field of intravascular device design. Before the final clinical trials on humans, research in the vascular area is conducted on animal models, swine being the most common due to the similarities between the human and swine cardiovascular systems as well as the fact that the swine size is suitable for testing devices, in this case endovascular carotid systems. The design of devices usually involves numerical techniques, and an important feature is the appropriate modelling of the mechanical properties of the vessel. Fourteen carotid swine arteries were harvested just after sacrifice and cyclic uniaxial tension tests in longitudinal and circumferential directions were performed for distal and proximal samples. The stress–stretch curves obtained were fitted with a hyperelastic anisotropic model. Stress-free configuration states were also analyzed. Finally, human and swine samples were processed in a histological laboratory and images were used to quantify their microconstituents. The statistical analysis revealed significant differences between the mechanical behavior of proximal and distal locations in the circumferential but not in the longitudinal direction. Circumferential direction samples show clear differences both in residual stretches and tensile curves between the two locations, while the features of longitudinal specimens are independent of the axial position. The statistical analysis provides significant evidence of changes depending on the position of the sample, mainly in elastin and SMC quantification.</description><subject>Animals</subject><subject>Anisotropy</subject><subject>Biological and medical sciences</subject><subject>Blood vessels and receptors</subject><subject>Carotid Arteries - pathology</subject><subject>Carotid Arteries - physiology</subject><subject>Carotid Arteries - ultrastructure</subject><subject>Carotid Artery, Common - pathology</subject><subject>Carotid Artery, Common - physiology</subject><subject>Computer Simulation</subject><subject>Constitutive model</subject><subject>Data fitting</subject><subject>Data Interpretation, Statistical</subject><subject>Elastic Modulus</subject><subject>Elasticity</subject><subject>Female</subject><subject>Fundamental and applied biological sciences. Psychology</subject><subject>Humans</subject><subject>Microscopy</subject><subject>Models, Animal</subject><subject>Models, Cardiovascular</subject><subject>Muscular and elastic artery</subject><subject>Radiology</subject><subject>Stress, Mechanical</subject><subject>Stress–stretch relation</subject><subject>Swine</subject><subject>Vertebrates: cardiovascular system</subject><issn>1350-4533</issn><issn>1873-4030</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqNks1uEzEUhUcIREvgFcAbxCrBHs8vC6SqKlCpEgtgbXnsO8kNE3vw9UTNU_JKeJoQJFaVLNmyv3tsn3Oz7I3gK8FF9X672oEFtx43h1XOhVjxeVRPskvR1HJZcMmfprUs-bIopbzIXhBtOedFUcnn2UUuZC3avL3Mft_cjxBwBy7qgVGc7IFpZ5nxjiLGKeIe2M5bGAZ0a-Z7FjfARk30cABmox2aVDoGn4QiAp0hHww6YEYHH9EyHSKEozpGYgEGHdE7Fj3bIEU_-PWDknZ6OBDSB3a7G4e0NVPE0KUT3CUgCVr0e01mGnRgFvZogMWAeqCX2bM-TfDqNC-yH59uvl9_Wd59_Xx7fXW3NEVTx2Xe6zK3umiANzxZ0UPddWBNVcvOFLkVTdWUZVtrMF1tdFe1WtTJTmnLxtrWykX27qib_v1rAopqh2SSS9qBn0g1dZXLti2KR5AFF22bz2R9JE3wRAF6NaZkdDgowdUcu9qqc-xqjl3xeVSp8vXpjqlLxLnub84JeHsCkmt66IN2BukfV0jelunzi-zqyEHybo8QFBkEZ8BiABOV9fiIx3z8T8Ok3pmj_QkHoK2fQkqYlFCUK66-zV06N6kQc4OKUv4B5fvrlQ</recordid><startdate>20110701</startdate><enddate>20110701</enddate><creator>García, A</creator><creator>Peña, E</creator><creator>Laborda, A</creator><creator>Lostalé, F</creator><creator>De Gregorio, M.A</creator><creator>Doblaré, M</creator><creator>Martínez, M.A</creator><general>Elsevier Ltd</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>20110701</creationdate><title>Experimental study and constitutive modelling of the passive mechanical properties of the porcine carotid artery and its relation to histological analysis: Implications in animal cardiovascular device trials</title><author>García, A ; Peña, E ; Laborda, A ; Lostalé, F ; De Gregorio, M.A ; Doblaré, M ; Martínez, M.A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c487t-2fa52da48e080719fe7bbedc673bc42d18685597aecb7cab69a171353d58dd9d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Animals</topic><topic>Anisotropy</topic><topic>Biological and medical sciences</topic><topic>Blood vessels and receptors</topic><topic>Carotid Arteries - pathology</topic><topic>Carotid Arteries - physiology</topic><topic>Carotid Arteries - ultrastructure</topic><topic>Carotid Artery, Common - pathology</topic><topic>Carotid Artery, Common - physiology</topic><topic>Computer Simulation</topic><topic>Constitutive model</topic><topic>Data fitting</topic><topic>Data Interpretation, Statistical</topic><topic>Elastic Modulus</topic><topic>Elasticity</topic><topic>Female</topic><topic>Fundamental and applied biological sciences. Psychology</topic><topic>Humans</topic><topic>Microscopy</topic><topic>Models, Animal</topic><topic>Models, Cardiovascular</topic><topic>Muscular and elastic artery</topic><topic>Radiology</topic><topic>Stress, Mechanical</topic><topic>Stress–stretch relation</topic><topic>Swine</topic><topic>Vertebrates: cardiovascular system</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>García, A</creatorcontrib><creatorcontrib>Peña, E</creatorcontrib><creatorcontrib>Laborda, A</creatorcontrib><creatorcontrib>Lostalé, F</creatorcontrib><creatorcontrib>De Gregorio, M.A</creatorcontrib><creatorcontrib>Doblaré, M</creatorcontrib><creatorcontrib>Martínez, M.A</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Medical engineering &amp; physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>García, A</au><au>Peña, E</au><au>Laborda, A</au><au>Lostalé, F</au><au>De Gregorio, M.A</au><au>Doblaré, M</au><au>Martínez, M.A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experimental study and constitutive modelling of the passive mechanical properties of the porcine carotid artery and its relation to histological analysis: Implications in animal cardiovascular device trials</atitle><jtitle>Medical engineering &amp; physics</jtitle><addtitle>Med Eng Phys</addtitle><date>2011-07-01</date><risdate>2011</risdate><volume>33</volume><issue>6</issue><spage>665</spage><epage>676</epage><pages>665-676</pages><issn>1350-4533</issn><eissn>1873-4030</eissn><abstract>Abstract The present study focusses on the determination, comparison and constitutive modelling of the passive mechanical properties of the swine carotid artery over very long stretches in both proximal and distal regions. Special attention is paid to the histological and mechanical variations of these properties depending on the proximity to the heart. The results can have clinical relevance, especially in the research field of intravascular device design. Before the final clinical trials on humans, research in the vascular area is conducted on animal models, swine being the most common due to the similarities between the human and swine cardiovascular systems as well as the fact that the swine size is suitable for testing devices, in this case endovascular carotid systems. The design of devices usually involves numerical techniques, and an important feature is the appropriate modelling of the mechanical properties of the vessel. Fourteen carotid swine arteries were harvested just after sacrifice and cyclic uniaxial tension tests in longitudinal and circumferential directions were performed for distal and proximal samples. The stress–stretch curves obtained were fitted with a hyperelastic anisotropic model. Stress-free configuration states were also analyzed. Finally, human and swine samples were processed in a histological laboratory and images were used to quantify their microconstituents. The statistical analysis revealed significant differences between the mechanical behavior of proximal and distal locations in the circumferential but not in the longitudinal direction. Circumferential direction samples show clear differences both in residual stretches and tensile curves between the two locations, while the features of longitudinal specimens are independent of the axial position. The statistical analysis provides significant evidence of changes depending on the position of the sample, mainly in elastin and SMC quantification.</abstract><cop>Kidlington</cop><pub>Elsevier Ltd</pub><pmid>21371929</pmid><doi>10.1016/j.medengphy.2011.01.016</doi><tpages>12</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1350-4533
ispartof Medical engineering & physics, 2011-07, Vol.33 (6), p.665-676
issn 1350-4533
1873-4030
language eng
recordid cdi_proquest_miscellaneous_876239944
source MEDLINE; ScienceDirect Journals (5 years ago - present)
subjects Animals
Anisotropy
Biological and medical sciences
Blood vessels and receptors
Carotid Arteries - pathology
Carotid Arteries - physiology
Carotid Arteries - ultrastructure
Carotid Artery, Common - pathology
Carotid Artery, Common - physiology
Computer Simulation
Constitutive model
Data fitting
Data Interpretation, Statistical
Elastic Modulus
Elasticity
Female
Fundamental and applied biological sciences. Psychology
Humans
Microscopy
Models, Animal
Models, Cardiovascular
Muscular and elastic artery
Radiology
Stress, Mechanical
Stress–stretch relation
Swine
Vertebrates: cardiovascular system
title Experimental study and constitutive modelling of the passive mechanical properties of the porcine carotid artery and its relation to histological analysis: Implications in animal cardiovascular device trials
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T05%3A26%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experimental%20study%20and%20constitutive%20modelling%20of%20the%20passive%20mechanical%20properties%20of%20the%20porcine%20carotid%20artery%20and%20its%20relation%20to%20histological%20analysis:%20Implications%20in%20animal%20cardiovascular%20device%20trials&rft.jtitle=Medical%20engineering%20&%20physics&rft.au=Garc%C3%ADa,%20A&rft.date=2011-07-01&rft.volume=33&rft.issue=6&rft.spage=665&rft.epage=676&rft.pages=665-676&rft.issn=1350-4533&rft.eissn=1873-4030&rft_id=info:doi/10.1016/j.medengphy.2011.01.016&rft_dat=%3Cproquest_cross%3E874019924%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=874019924&rft_id=info:pmid/21371929&rft_els_id=1_s2_0_S1350453311000415&rfr_iscdi=true