GI endoscopes

The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, performing a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. F...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gastrointestinal endoscopy 2011-07, Vol.74 (1), p.1-6.e6
Hauptverfasser: Varadarajulu, Shyam, MD, Banerjee, Subhas, MD, Barth, Bradley A., MD, Desilets, David J., MD, Kaul, Vivek, MD, Kethu, Sripathi R., MD, Pedrosa, Marcos C., MD, Pfau, Patrick R., MD, Tokar, Jeffrey L., MD, Wang, Amy, MD, Wong Kee Song, Louis-Michel, MD, Rodriguez, Sarah A., MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 6.e6
container_issue 1
container_start_page 1
container_title Gastrointestinal endoscopy
container_volume 74
creator Varadarajulu, Shyam, MD
Banerjee, Subhas, MD
Barth, Bradley A., MD
Desilets, David J., MD
Kaul, Vivek, MD
Kethu, Sripathi R., MD
Pedrosa, Marcos C., MD
Pfau, Patrick R., MD
Tokar, Jeffrey L., MD
Wang, Amy, MD
Wong Kee Song, Louis-Michel, MD
Rodriguez, Sarah A., MD
description The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, performing a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the “related articles” feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the Committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through September 2010 for articles related to endoscopy by using the key words “gastroscope,” “colonoscope,” “echoendoscope,” “duodenoscope,” “choledochoscope,” “ultraslim endoscope,” “variable stiffness colonoscope,” and “wide-angle colonoscope.” Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.
doi_str_mv 10.1016/j.gie.2011.01.061
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_874018122</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>1_s2_0_S0016510711001301</els_id><sourcerecordid>874018122</sourcerecordid><originalsourceid>FETCH-LOGICAL-c407t-5789b96a0f1609f787e0edc1d070a44406b80b62172c6dc592c6dfd1f29bf9ab3</originalsourceid><addsrcrecordid>eNp9kUFLw0AQhRdRbK39AV7Em6fEmU26m0UQpGgtFDyo5yXZTGRjmtTdRui_d0OrBw_Cg9nD994ybxi7QIgRUNzU8bulmANiDEECj9gYQclISKmO2RgCFM0Q5IideV8DQMYTPGUjjhLSDJIxmy6WV9SWnTfdhvw5O6nyxtP0MCfs7fHhdf4UrZ4Xy_n9KjIpyG00k5kqlMihQgGqkpkkoNJgCRLyNE1BFBkUIvzCjSjNTA2jKrHiqqhUXiQTdr3P3bjusye_1WvrDTVN3lLXe53JFDBDzgOJe9K4zntHld44u87dTiPooQRd61CCHkrQECQweC4P6X2xpvLX8bN1AG73AIUdvyw57Y2l1lBpHZmtLjv7b_zdH7dpbGtN3nzQjnzd9a4N5WnUnmvQL8MVhiMghlcS9A06y34i</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>874018122</pqid></control><display><type>article</type><title>GI endoscopes</title><source>MEDLINE</source><source>Access via ScienceDirect (Elsevier)</source><creator>Varadarajulu, Shyam, MD ; Banerjee, Subhas, MD ; Barth, Bradley A., MD ; Desilets, David J., MD ; Kaul, Vivek, MD ; Kethu, Sripathi R., MD ; Pedrosa, Marcos C., MD ; Pfau, Patrick R., MD ; Tokar, Jeffrey L., MD ; Wang, Amy, MD ; Wong Kee Song, Louis-Michel, MD ; Rodriguez, Sarah A., MD</creator><creatorcontrib>Varadarajulu, Shyam, MD ; Banerjee, Subhas, MD ; Barth, Bradley A., MD ; Desilets, David J., MD ; Kaul, Vivek, MD ; Kethu, Sripathi R., MD ; Pedrosa, Marcos C., MD ; Pfau, Patrick R., MD ; Tokar, Jeffrey L., MD ; Wang, Amy, MD ; Wong Kee Song, Louis-Michel, MD ; Rodriguez, Sarah A., MD ; ASGE Technology Committee</creatorcontrib><description>The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, performing a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the “related articles” feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the Committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through September 2010 for articles related to endoscopy by using the key words “gastroscope,” “colonoscope,” “echoendoscope,” “duodenoscope,” “choledochoscope,” “ultraslim endoscope,” “variable stiffness colonoscope,” and “wide-angle colonoscope.” Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.</description><identifier>ISSN: 0016-5107</identifier><identifier>EISSN: 1097-6779</identifier><identifier>DOI: 10.1016/j.gie.2011.01.061</identifier><identifier>PMID: 21704803</identifier><language>eng</language><publisher>United States: Mosby, Inc</publisher><subject>Endoscopes, Gastrointestinal - economics ; Endoscopy, Gastrointestinal - adverse effects ; Endoscopy, Gastrointestinal - instrumentation ; Female ; Gastroenterology and Hepatology ; Humans ; Male ; Randomized Controlled Trials as Topic ; Safety</subject><ispartof>Gastrointestinal endoscopy, 2011-07, Vol.74 (1), p.1-6.e6</ispartof><rights>American Society for Gastrointestinal Endoscopy</rights><rights>2011 American Society for Gastrointestinal Endoscopy</rights><rights>Copyright © 2011 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c407t-5789b96a0f1609f787e0edc1d070a44406b80b62172c6dc592c6dfd1f29bf9ab3</citedby><cites>FETCH-LOGICAL-c407t-5789b96a0f1609f787e0edc1d070a44406b80b62172c6dc592c6dfd1f29bf9ab3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.gie.2011.01.061$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>315,782,786,3552,27931,27932,46002</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21704803$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Varadarajulu, Shyam, MD</creatorcontrib><creatorcontrib>Banerjee, Subhas, MD</creatorcontrib><creatorcontrib>Barth, Bradley A., MD</creatorcontrib><creatorcontrib>Desilets, David J., MD</creatorcontrib><creatorcontrib>Kaul, Vivek, MD</creatorcontrib><creatorcontrib>Kethu, Sripathi R., MD</creatorcontrib><creatorcontrib>Pedrosa, Marcos C., MD</creatorcontrib><creatorcontrib>Pfau, Patrick R., MD</creatorcontrib><creatorcontrib>Tokar, Jeffrey L., MD</creatorcontrib><creatorcontrib>Wang, Amy, MD</creatorcontrib><creatorcontrib>Wong Kee Song, Louis-Michel, MD</creatorcontrib><creatorcontrib>Rodriguez, Sarah A., MD</creatorcontrib><creatorcontrib>ASGE Technology Committee</creatorcontrib><title>GI endoscopes</title><title>Gastrointestinal endoscopy</title><addtitle>Gastrointest Endosc</addtitle><description>The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, performing a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the “related articles” feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the Committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through September 2010 for articles related to endoscopy by using the key words “gastroscope,” “colonoscope,” “echoendoscope,” “duodenoscope,” “choledochoscope,” “ultraslim endoscope,” “variable stiffness colonoscope,” and “wide-angle colonoscope.” Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.</description><subject>Endoscopes, Gastrointestinal - economics</subject><subject>Endoscopy, Gastrointestinal - adverse effects</subject><subject>Endoscopy, Gastrointestinal - instrumentation</subject><subject>Female</subject><subject>Gastroenterology and Hepatology</subject><subject>Humans</subject><subject>Male</subject><subject>Randomized Controlled Trials as Topic</subject><subject>Safety</subject><issn>0016-5107</issn><issn>1097-6779</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kUFLw0AQhRdRbK39AV7Em6fEmU26m0UQpGgtFDyo5yXZTGRjmtTdRui_d0OrBw_Cg9nD994ybxi7QIgRUNzU8bulmANiDEECj9gYQclISKmO2RgCFM0Q5IideV8DQMYTPGUjjhLSDJIxmy6WV9SWnTfdhvw5O6nyxtP0MCfs7fHhdf4UrZ4Xy_n9KjIpyG00k5kqlMihQgGqkpkkoNJgCRLyNE1BFBkUIvzCjSjNTA2jKrHiqqhUXiQTdr3P3bjusye_1WvrDTVN3lLXe53JFDBDzgOJe9K4zntHld44u87dTiPooQRd61CCHkrQECQweC4P6X2xpvLX8bN1AG73AIUdvyw57Y2l1lBpHZmtLjv7b_zdH7dpbGtN3nzQjnzd9a4N5WnUnmvQL8MVhiMghlcS9A06y34i</recordid><startdate>20110701</startdate><enddate>20110701</enddate><creator>Varadarajulu, Shyam, MD</creator><creator>Banerjee, Subhas, MD</creator><creator>Barth, Bradley A., MD</creator><creator>Desilets, David J., MD</creator><creator>Kaul, Vivek, MD</creator><creator>Kethu, Sripathi R., MD</creator><creator>Pedrosa, Marcos C., MD</creator><creator>Pfau, Patrick R., MD</creator><creator>Tokar, Jeffrey L., MD</creator><creator>Wang, Amy, MD</creator><creator>Wong Kee Song, Louis-Michel, MD</creator><creator>Rodriguez, Sarah A., MD</creator><general>Mosby, Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20110701</creationdate><title>GI endoscopes</title><author>Varadarajulu, Shyam, MD ; Banerjee, Subhas, MD ; Barth, Bradley A., MD ; Desilets, David J., MD ; Kaul, Vivek, MD ; Kethu, Sripathi R., MD ; Pedrosa, Marcos C., MD ; Pfau, Patrick R., MD ; Tokar, Jeffrey L., MD ; Wang, Amy, MD ; Wong Kee Song, Louis-Michel, MD ; Rodriguez, Sarah A., MD</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c407t-5789b96a0f1609f787e0edc1d070a44406b80b62172c6dc592c6dfd1f29bf9ab3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Endoscopes, Gastrointestinal - economics</topic><topic>Endoscopy, Gastrointestinal - adverse effects</topic><topic>Endoscopy, Gastrointestinal - instrumentation</topic><topic>Female</topic><topic>Gastroenterology and Hepatology</topic><topic>Humans</topic><topic>Male</topic><topic>Randomized Controlled Trials as Topic</topic><topic>Safety</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Varadarajulu, Shyam, MD</creatorcontrib><creatorcontrib>Banerjee, Subhas, MD</creatorcontrib><creatorcontrib>Barth, Bradley A., MD</creatorcontrib><creatorcontrib>Desilets, David J., MD</creatorcontrib><creatorcontrib>Kaul, Vivek, MD</creatorcontrib><creatorcontrib>Kethu, Sripathi R., MD</creatorcontrib><creatorcontrib>Pedrosa, Marcos C., MD</creatorcontrib><creatorcontrib>Pfau, Patrick R., MD</creatorcontrib><creatorcontrib>Tokar, Jeffrey L., MD</creatorcontrib><creatorcontrib>Wang, Amy, MD</creatorcontrib><creatorcontrib>Wong Kee Song, Louis-Michel, MD</creatorcontrib><creatorcontrib>Rodriguez, Sarah A., MD</creatorcontrib><creatorcontrib>ASGE Technology Committee</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Gastrointestinal endoscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Varadarajulu, Shyam, MD</au><au>Banerjee, Subhas, MD</au><au>Barth, Bradley A., MD</au><au>Desilets, David J., MD</au><au>Kaul, Vivek, MD</au><au>Kethu, Sripathi R., MD</au><au>Pedrosa, Marcos C., MD</au><au>Pfau, Patrick R., MD</au><au>Tokar, Jeffrey L., MD</au><au>Wang, Amy, MD</au><au>Wong Kee Song, Louis-Michel, MD</au><au>Rodriguez, Sarah A., MD</au><aucorp>ASGE Technology Committee</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>GI endoscopes</atitle><jtitle>Gastrointestinal endoscopy</jtitle><addtitle>Gastrointest Endosc</addtitle><date>2011-07-01</date><risdate>2011</risdate><volume>74</volume><issue>1</issue><spage>1</spage><epage>6.e6</epage><pages>1-6.e6</pages><issn>0016-5107</issn><eissn>1097-6779</eissn><abstract>The ASGE Technology Committee provides reviews of existing, new, or emerging endoscopic technologies that have an impact on the practice of GI endoscopy. Evidence-based methodology is used, performing a MEDLINE literature search to identify pertinent clinical studies on the topic and a MAUDE (U.S. Food and Drug Administration Center for Devices and Radiological Health) database search to identify the reported complications of a given technology. Both are supplemented by accessing the “related articles” feature of PubMed and by scrutinizing pertinent references cited by the identified studies. Controlled clinical trials are emphasized, but in many cases data from randomized, controlled trials are lacking. In such cases, large case series, preliminary clinical studies, and expert opinions are used. Technical data are gathered from traditional and Web-based publications, proprietary publications, and informal communications with pertinent vendors. Technology Status Evaluation Reports are drafted by 1 or 2 members of the ASGE Technology Committee, reviewed and edited by the Committee as a whole, and approved by the Governing Board of the ASGE. When financial guidance is indicated, the most recent coding data and list prices at the time of publication are provided. For this review, the MEDLINE database was searched through September 2010 for articles related to endoscopy by using the key words “gastroscope,” “colonoscope,” “echoendoscope,” “duodenoscope,” “choledochoscope,” “ultraslim endoscope,” “variable stiffness colonoscope,” and “wide-angle colonoscope.” Technology Status Evaluation Reports are scientific reviews provided solely for educational and informational purposes. Technology Status Evaluation Reports are not rules and should not be construed as establishing a legal standard of care or as encouraging, advocating, requiring, or discouraging any particular treatment or payment for such treatment.</abstract><cop>United States</cop><pub>Mosby, Inc</pub><pmid>21704803</pmid><doi>10.1016/j.gie.2011.01.061</doi></addata></record>
fulltext fulltext
identifier ISSN: 0016-5107
ispartof Gastrointestinal endoscopy, 2011-07, Vol.74 (1), p.1-6.e6
issn 0016-5107
1097-6779
language eng
recordid cdi_proquest_miscellaneous_874018122
source MEDLINE; Access via ScienceDirect (Elsevier)
subjects Endoscopes, Gastrointestinal - economics
Endoscopy, Gastrointestinal - adverse effects
Endoscopy, Gastrointestinal - instrumentation
Female
Gastroenterology and Hepatology
Humans
Male
Randomized Controlled Trials as Topic
Safety
title GI endoscopes
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-05T11%3A07%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=GI%20endoscopes&rft.jtitle=Gastrointestinal%20endoscopy&rft.au=Varadarajulu,%20Shyam,%20MD&rft.aucorp=ASGE%20Technology%20Committee&rft.date=2011-07-01&rft.volume=74&rft.issue=1&rft.spage=1&rft.epage=6.e6&rft.pages=1-6.e6&rft.issn=0016-5107&rft.eissn=1097-6779&rft_id=info:doi/10.1016/j.gie.2011.01.061&rft_dat=%3Cproquest_cross%3E874018122%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=874018122&rft_id=info:pmid/21704803&rft_els_id=1_s2_0_S0016510711001301&rfr_iscdi=true