International comparative field study of N8 evaluating factor VIII assay performance

Discrepancies between the one‐stage clotting assay and the chromogenic method, and also among different variations of each method, have been a significant challenge for one B‐domain deleted FVIII product. N8 is a B‐domain truncated FVIII product developed by Novo Nordisk. The comparison of N8 and Ad...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Haemophilia : the official journal of the World Federation of Hemophilia 2011-07, Vol.17 (4), p.695-702
Hauptverfasser: VIUFF, D., BARROWCLIFFE, TW, SAUGSTRUP, T., EZBAN, M., LILLICRAP, D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Discrepancies between the one‐stage clotting assay and the chromogenic method, and also among different variations of each method, have been a significant challenge for one B‐domain deleted FVIII product. N8 is a B‐domain truncated FVIII product developed by Novo Nordisk. The comparison of N8 and Advate® was performed in an international, multicentre, randomized and blinded field study of simulated postinfusion samples. Overall, Advate® and N8 performed similarly in the one‐stage assay. In the one‐stage clotting assay, the measured mean FVIII levels of Advate® vs. N8 were 0.046/0.047, 0.24/0.24, 0.58/0.60 and 0.82/0.83 IU mL−1 for the target values of 0.03, 0.2, 0.6 and 0.9 IU mL−1, respectively. In the chromogenic assays, the concentration estimates showed a tendency towards higher N8 values as compared with Advate®; the measured FVIII levels of Advate® vs. N8 were 0.030/0.032, 0.22/0.24, 0.65/0.74 and 0.98/1.08 IU mL−1 for the target values of 0.03, 0.2, 0.6 and 0.9 IU mL−1, respectively. In the one‐stage assays, the measured values were above 150% of target at the lowest concentration, decreasing to around 90% of target at the highest concentration. In contrast, the chromogenic assays were close to target at the lowest concentration and consistently above target at the three highest concentrations. Therefore, the ratio of chromogenic/one‐stage potencies was concentration dependent, ranging from 0.66 to 1.30. The SSC plasma standard was similar in both. Assay variability was similar for both compounds. The results show that N8 can be reliably measured in plasma without the need for a separate N8 standard.
ISSN:1351-8216
1365-2516
DOI:10.1111/j.1365-2516.2010.02481.x