Triiodide PVC Membrane Electrode Based on a Charge-Transfer Complex of Iodine with 2,4,6,8- Tetraphenyl-2,4,6,8-tetraazabicyclo[3.3.0]octane

A novel triiodide ion-selective electrode based on a charge-transfer complex of iodine with 2,4,6,8-tetraphenyl-2,4,6,8-tetraazabicyclo[3.3.0]octane as membrane carrier was prepared. The electrode has a linear dynamic range between 5.0 × 10-2 and 3.5 × 10-6 M, with a near-Nernstian slope of 54.7 ± 0...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical chemistry (Washington) 1999-04, Vol.71 (7), p.1350-1353
Hauptverfasser: Rouhollahi, Ahmad, Shamsipur, Mojtaba
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1353
container_issue 7
container_start_page 1350
container_title Analytical chemistry (Washington)
container_volume 71
creator Rouhollahi, Ahmad
Shamsipur, Mojtaba
description A novel triiodide ion-selective electrode based on a charge-transfer complex of iodine with 2,4,6,8-tetraphenyl-2,4,6,8-tetraazabicyclo[3.3.0]octane as membrane carrier was prepared. The electrode has a linear dynamic range between 5.0 × 10-2 and 3.5 × 10-6 M, with a near-Nernstian slope of 54.7 ± 0.8 mV decade-1 and a detection limit of 2.0 × 10-6 M. The potentiometric response is independent of the pH of the solution in the pH range 4.0−10.5. The electrode possesses the advantages of low resistance, short conditioning time, fast response, and, especially, very good selectivities over a wide variety of other anions. The electrode can be used for at least 10 months without any considerable divergence in potentials. It was used as an indicator electrode in potentiometric titration of triiodide ions.
doi_str_mv 10.1021/ac981077x
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_872526574</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>41286202</sourcerecordid><originalsourceid>FETCH-LOGICAL-a406t-914537e4fcb74297ec49334a38f29ea92f826f6d864fce529538094c9cbe15e03</originalsourceid><addsrcrecordid>eNpl0VuLEzEUB_AgiltXH_wCEkQRoVNzm1weddjVhRUXHC8gEjLpGTu7M01Nptj6GfzQZmm3C_oUOPnln5MchB5TMqOE0VfOG02JUps7aEJLRgqpNbuLJoQQXjBFyBF6kNIlIZQSKu-jI0alZKZUE_Snjl0X5t0c8MXnCr-HoYluCfikBz_GkMtvXII5DkvscLVw8QcUdRaphYirMKx62ODQ4rOckY_96sYFZlMxlVNd4BrG6FYLWG774qY4Xtfcb9d0fuv78I3P-Ix8D37Mtz5E91rXJ3i0X4_Rp9OTunpXnH94e1a9Pi-cIHIsDBUlVyBa3yjBjAIvDOfCcd0yA86wVjPZyrmWmUCZH8o1McIb3wAtgfBj9GKXu4rh5xrSaIcueej73ENYJ6sVK5kslcjy6T_yMqzjMjdnGVWGEEVNRi93yMeQUoTWrmI3uLi1lNjrAdnDgLJ9sg9cNwPMD_JmIhk82wOXvOvb_Ne-S7eJimspy8yKHevSCJvDtotXViquSltffLT8KxXqi2L2NPvnO-98un3D__39Bfjrryo</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>217900719</pqid></control><display><type>article</type><title>Triiodide PVC Membrane Electrode Based on a Charge-Transfer Complex of Iodine with 2,4,6,8- Tetraphenyl-2,4,6,8-tetraazabicyclo[3.3.0]octane</title><source>American Chemical Society Journals</source><creator>Rouhollahi, Ahmad ; Shamsipur, Mojtaba</creator><creatorcontrib>Rouhollahi, Ahmad ; Shamsipur, Mojtaba</creatorcontrib><description>A novel triiodide ion-selective electrode based on a charge-transfer complex of iodine with 2,4,6,8-tetraphenyl-2,4,6,8-tetraazabicyclo[3.3.0]octane as membrane carrier was prepared. The electrode has a linear dynamic range between 5.0 × 10-2 and 3.5 × 10-6 M, with a near-Nernstian slope of 54.7 ± 0.8 mV decade-1 and a detection limit of 2.0 × 10-6 M. The potentiometric response is independent of the pH of the solution in the pH range 4.0−10.5. The electrode possesses the advantages of low resistance, short conditioning time, fast response, and, especially, very good selectivities over a wide variety of other anions. The electrode can be used for at least 10 months without any considerable divergence in potentials. It was used as an indicator electrode in potentiometric titration of triiodide ions.</description><identifier>ISSN: 0003-2700</identifier><identifier>EISSN: 1520-6882</identifier><identifier>DOI: 10.1021/ac981077x</identifier><identifier>PMID: 21662957</identifier><identifier>CODEN: ANCHAM</identifier><language>eng</language><publisher>Washington, DC: American Chemical Society</publisher><subject>Analytical chemistry ; Chemistry ; Electrochemistry ; Electrodes: preparations and properties ; Exact sciences and technology ; General and physical chemistry ; General, instrumentation ; Ion selective electrodes ; Ions ; Membranes</subject><ispartof>Analytical chemistry (Washington), 1999-04, Vol.71 (7), p.1350-1353</ispartof><rights>Copyright © 1999 American Chemical Society</rights><rights>1999 INIST-CNRS</rights><rights>Copyright American Chemical Society Apr 1, 1999</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a406t-914537e4fcb74297ec49334a38f29ea92f826f6d864fce529538094c9cbe15e03</citedby><cites>FETCH-LOGICAL-a406t-914537e4fcb74297ec49334a38f29ea92f826f6d864fce529538094c9cbe15e03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/ac981077x$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/ac981077x$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,780,784,2765,27076,27924,27925,56738,56788</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1738665$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21662957$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Rouhollahi, Ahmad</creatorcontrib><creatorcontrib>Shamsipur, Mojtaba</creatorcontrib><title>Triiodide PVC Membrane Electrode Based on a Charge-Transfer Complex of Iodine with 2,4,6,8- Tetraphenyl-2,4,6,8-tetraazabicyclo[3.3.0]octane</title><title>Analytical chemistry (Washington)</title><addtitle>Anal. Chem</addtitle><description>A novel triiodide ion-selective electrode based on a charge-transfer complex of iodine with 2,4,6,8-tetraphenyl-2,4,6,8-tetraazabicyclo[3.3.0]octane as membrane carrier was prepared. The electrode has a linear dynamic range between 5.0 × 10-2 and 3.5 × 10-6 M, with a near-Nernstian slope of 54.7 ± 0.8 mV decade-1 and a detection limit of 2.0 × 10-6 M. The potentiometric response is independent of the pH of the solution in the pH range 4.0−10.5. The electrode possesses the advantages of low resistance, short conditioning time, fast response, and, especially, very good selectivities over a wide variety of other anions. The electrode can be used for at least 10 months without any considerable divergence in potentials. It was used as an indicator electrode in potentiometric titration of triiodide ions.</description><subject>Analytical chemistry</subject><subject>Chemistry</subject><subject>Electrochemistry</subject><subject>Electrodes: preparations and properties</subject><subject>Exact sciences and technology</subject><subject>General and physical chemistry</subject><subject>General, instrumentation</subject><subject>Ion selective electrodes</subject><subject>Ions</subject><subject>Membranes</subject><issn>0003-2700</issn><issn>1520-6882</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNpl0VuLEzEUB_AgiltXH_wCEkQRoVNzm1weddjVhRUXHC8gEjLpGTu7M01Nptj6GfzQZmm3C_oUOPnln5MchB5TMqOE0VfOG02JUps7aEJLRgqpNbuLJoQQXjBFyBF6kNIlIZQSKu-jI0alZKZUE_Snjl0X5t0c8MXnCr-HoYluCfikBz_GkMtvXII5DkvscLVw8QcUdRaphYirMKx62ODQ4rOckY_96sYFZlMxlVNd4BrG6FYLWG774qY4Xtfcb9d0fuv78I3P-Ix8D37Mtz5E91rXJ3i0X4_Rp9OTunpXnH94e1a9Pi-cIHIsDBUlVyBa3yjBjAIvDOfCcd0yA86wVjPZyrmWmUCZH8o1McIb3wAtgfBj9GKXu4rh5xrSaIcueej73ENYJ6sVK5kslcjy6T_yMqzjMjdnGVWGEEVNRi93yMeQUoTWrmI3uLi1lNjrAdnDgLJ9sg9cNwPMD_JmIhk82wOXvOvb_Ne-S7eJimspy8yKHevSCJvDtotXViquSltffLT8KxXqi2L2NPvnO-98un3D__39Bfjrryo</recordid><startdate>19990401</startdate><enddate>19990401</enddate><creator>Rouhollahi, Ahmad</creator><creator>Shamsipur, Mojtaba</creator><general>American Chemical Society</general><scope>BSCLL</scope><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7TM</scope><scope>7U5</scope><scope>7U7</scope><scope>7U9</scope><scope>8BQ</scope><scope>8FD</scope><scope>C1K</scope><scope>F28</scope><scope>FR3</scope><scope>H8D</scope><scope>H8G</scope><scope>H94</scope><scope>JG9</scope><scope>JQ2</scope><scope>KR7</scope><scope>L7M</scope><scope>L~C</scope><scope>L~D</scope><scope>P64</scope><scope>7X8</scope></search><sort><creationdate>19990401</creationdate><title>Triiodide PVC Membrane Electrode Based on a Charge-Transfer Complex of Iodine with 2,4,6,8- Tetraphenyl-2,4,6,8-tetraazabicyclo[3.3.0]octane</title><author>Rouhollahi, Ahmad ; Shamsipur, Mojtaba</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a406t-914537e4fcb74297ec49334a38f29ea92f826f6d864fce529538094c9cbe15e03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>Analytical chemistry</topic><topic>Chemistry</topic><topic>Electrochemistry</topic><topic>Electrodes: preparations and properties</topic><topic>Exact sciences and technology</topic><topic>General and physical chemistry</topic><topic>General, instrumentation</topic><topic>Ion selective electrodes</topic><topic>Ions</topic><topic>Membranes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rouhollahi, Ahmad</creatorcontrib><creatorcontrib>Shamsipur, Mojtaba</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Nucleic Acids Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ANTE: Abstracts in New Technology &amp; Engineering</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Computer and Information Systems Abstracts – Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>MEDLINE - Academic</collection><jtitle>Analytical chemistry (Washington)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rouhollahi, Ahmad</au><au>Shamsipur, Mojtaba</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Triiodide PVC Membrane Electrode Based on a Charge-Transfer Complex of Iodine with 2,4,6,8- Tetraphenyl-2,4,6,8-tetraazabicyclo[3.3.0]octane</atitle><jtitle>Analytical chemistry (Washington)</jtitle><addtitle>Anal. Chem</addtitle><date>1999-04-01</date><risdate>1999</risdate><volume>71</volume><issue>7</issue><spage>1350</spage><epage>1353</epage><pages>1350-1353</pages><issn>0003-2700</issn><eissn>1520-6882</eissn><coden>ANCHAM</coden><abstract>A novel triiodide ion-selective electrode based on a charge-transfer complex of iodine with 2,4,6,8-tetraphenyl-2,4,6,8-tetraazabicyclo[3.3.0]octane as membrane carrier was prepared. The electrode has a linear dynamic range between 5.0 × 10-2 and 3.5 × 10-6 M, with a near-Nernstian slope of 54.7 ± 0.8 mV decade-1 and a detection limit of 2.0 × 10-6 M. The potentiometric response is independent of the pH of the solution in the pH range 4.0−10.5. The electrode possesses the advantages of low resistance, short conditioning time, fast response, and, especially, very good selectivities over a wide variety of other anions. The electrode can be used for at least 10 months without any considerable divergence in potentials. It was used as an indicator electrode in potentiometric titration of triiodide ions.</abstract><cop>Washington, DC</cop><pub>American Chemical Society</pub><pmid>21662957</pmid><doi>10.1021/ac981077x</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2700
ispartof Analytical chemistry (Washington), 1999-04, Vol.71 (7), p.1350-1353
issn 0003-2700
1520-6882
language eng
recordid cdi_proquest_miscellaneous_872526574
source American Chemical Society Journals
subjects Analytical chemistry
Chemistry
Electrochemistry
Electrodes: preparations and properties
Exact sciences and technology
General and physical chemistry
General, instrumentation
Ion selective electrodes
Ions
Membranes
title Triiodide PVC Membrane Electrode Based on a Charge-Transfer Complex of Iodine with 2,4,6,8- Tetraphenyl-2,4,6,8-tetraazabicyclo[3.3.0]octane
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T06%3A36%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Triiodide%20PVC%20Membrane%20Electrode%20Based%20on%20a%20Charge-Transfer%20Complex%20of%20Iodine%20with%202,4,6,8-%20Tetraphenyl-2,4,6,8-tetraazabicyclo%5B3.3.0%5Doctane&rft.jtitle=Analytical%20chemistry%20(Washington)&rft.au=Rouhollahi,%20Ahmad&rft.date=1999-04-01&rft.volume=71&rft.issue=7&rft.spage=1350&rft.epage=1353&rft.pages=1350-1353&rft.issn=0003-2700&rft.eissn=1520-6882&rft.coden=ANCHAM&rft_id=info:doi/10.1021/ac981077x&rft_dat=%3Cproquest_cross%3E41286202%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=217900719&rft_id=info:pmid/21662957&rfr_iscdi=true