Towards an automated, standardized protocol for determination of equilibrium potential of ion-selective electrodes

An automated real-time method for determination of ISE steady state value and response time is developed, following most recent IUPAC recommendations. Specifically, detection of the ‘steady state’ is related to (1) the time derivative of the emf as it reaches a limiting value (Δ E/Δ t limit, e.g., 0...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytica chimica acta 2011-03, Vol.690 (1), p.71-78
Hauptverfasser: Mueller, Amy V., Hemond, Harold F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 78
container_issue 1
container_start_page 71
container_title Analytica chimica acta
container_volume 690
creator Mueller, Amy V.
Hemond, Harold F.
description An automated real-time method for determination of ISE steady state value and response time is developed, following most recent IUPAC recommendations. Specifically, detection of the ‘steady state’ is related to (1) the time derivative of the emf as it reaches a limiting value (Δ E/Δ t limit, e.g., 0.1–1.0 mV min −1) and (2) the duration of time for which the absolute value of the time derivative remains less than this limiting value (stability window, denoted win st). A suite of representative ISEs, including glass, solid state, and polymer-based electrodes, is examined to determine sensitivity of results to parameterization choice. Measurements taken over a wide range of concentration values and in un-processed samples (i.e., without use of ionic strength adjustment) provide insight into behavior of ISEs in applications where analyte concentrations span a wide range and/or sample pre-processing may not be an option, e.g., use of sensors for in situ environmental sampling. Results show that declared steady state emf is strongly sensitive to variations in Δ E/Δ t limit but relatively unaffected by changes in the stability window when win st ≥30 s. Linearity of calibration curves produced, quantified by root mean squared error (RMSE) against a linear fit, improves as Δ E/Δ t limit decreases, however the percentage of measurements which reach a declared steady state within the prescribed sample window (∼6.5 min) falls with corresponding decreases in the Δ E/Δ t limit parameter. Response time, defined as the time required to reach declared steady emf, is also a strong function of parameterization. Dependence of response times on sample composition and/or ISE membrane composition and type are also discussed; results for ISEs in samples comprised exclusively of interfering ions are included. In general, limiting emf derivatives of {0.25–0.4 mV min −1} and stability windows of {30–40 s} achieve both good analytical accuracy and compliance with potentially short sampling window requirements. Methodology based on use of these parameters can improve sampling speed and accuracy as well as promote inter-comparison of data and ISE characterizations among research teams.
doi_str_mv 10.1016/j.aca.2011.02.011
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_869845591</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0003267011001838</els_id><sourcerecordid>869845591</sourcerecordid><originalsourceid>FETCH-LOGICAL-c414t-82b34e8c0743ab3ee766325cc16b70e644ac55f755d3b1970dd6e09334ca09e63</originalsourceid><addsrcrecordid>eNqFkU1v1DAQhi0EosuWH9BL5QviQoK_4iTqCVV8SZW4tGdrYk8kr5J4azut4NfjZZf2BqexZ5559WpeQi44qznj-uOuBgu1YJzXTNSlvCAb3rWyUlKol2TDGJOV0C07I29S2pWv4Ey9JmeCK66U7DYk3oZHiC5RWCisOcyQ0X2gKcPiSt__Qkf3MeRgw0THEKnDjHH2C2QfFhpGivern_wQ_TrTfci4ZA_TYVDmVcIJbfYPSP88YnCYzsmrEaaEb091S-6-fL69_lbd_Pj6_frTTWWLuVx1YpAKO8taJWGQiK3WUjTWcj20DLVSYJtmbJvGyYH3LXNOI-ulVBZYj1puyfujbvF_v2LKZvbJ4jTBgmFNptN9p5qm5_8nm7bjWhXtLeFH0saQUsTR7KOfIf40nJlDJmZnSibmkIlhwpRSdi5P6uswo3va-BtCAd6dAEgWpjHCYn165mSve9aLwl0dOSxXe_AYTbIeF4vOx3Jc44L_h43fM12qkw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>857816493</pqid></control><display><type>article</type><title>Towards an automated, standardized protocol for determination of equilibrium potential of ion-selective electrodes</title><source>Elsevier ScienceDirect Journals</source><creator>Mueller, Amy V. ; Hemond, Harold F.</creator><creatorcontrib>Mueller, Amy V. ; Hemond, Harold F.</creatorcontrib><description>An automated real-time method for determination of ISE steady state value and response time is developed, following most recent IUPAC recommendations. Specifically, detection of the ‘steady state’ is related to (1) the time derivative of the emf as it reaches a limiting value (Δ E/Δ t limit, e.g., 0.1–1.0 mV min −1) and (2) the duration of time for which the absolute value of the time derivative remains less than this limiting value (stability window, denoted win st). A suite of representative ISEs, including glass, solid state, and polymer-based electrodes, is examined to determine sensitivity of results to parameterization choice. Measurements taken over a wide range of concentration values and in un-processed samples (i.e., without use of ionic strength adjustment) provide insight into behavior of ISEs in applications where analyte concentrations span a wide range and/or sample pre-processing may not be an option, e.g., use of sensors for in situ environmental sampling. Results show that declared steady state emf is strongly sensitive to variations in Δ E/Δ t limit but relatively unaffected by changes in the stability window when win st ≥30 s. Linearity of calibration curves produced, quantified by root mean squared error (RMSE) against a linear fit, improves as Δ E/Δ t limit decreases, however the percentage of measurements which reach a declared steady state within the prescribed sample window (∼6.5 min) falls with corresponding decreases in the Δ E/Δ t limit parameter. Response time, defined as the time required to reach declared steady emf, is also a strong function of parameterization. Dependence of response times on sample composition and/or ISE membrane composition and type are also discussed; results for ISEs in samples comprised exclusively of interfering ions are included. In general, limiting emf derivatives of {0.25–0.4 mV min −1} and stability windows of {30–40 s} achieve both good analytical accuracy and compliance with potentially short sampling window requirements. Methodology based on use of these parameters can improve sampling speed and accuracy as well as promote inter-comparison of data and ISE characterizations among research teams.</description><identifier>ISSN: 0003-2670</identifier><identifier>EISSN: 1873-4324</identifier><identifier>DOI: 10.1016/j.aca.2011.02.011</identifier><identifier>PMID: 21414438</identifier><identifier>CODEN: ACACAM</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Applied sciences ; Automation ; Chemistry ; Electrochemical methods ; Equilibration detection ; Exact sciences and technology ; General, instrumentation ; Global environmental pollution ; Ion selective electrodes ; Pollution</subject><ispartof>Analytica chimica acta, 2011-03, Vol.690 (1), p.71-78</ispartof><rights>2011 Elsevier B.V.</rights><rights>2015 INIST-CNRS</rights><rights>Copyright © 2011 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c414t-82b34e8c0743ab3ee766325cc16b70e644ac55f755d3b1970dd6e09334ca09e63</citedby><cites>FETCH-LOGICAL-c414t-82b34e8c0743ab3ee766325cc16b70e644ac55f755d3b1970dd6e09334ca09e63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0003267011001838$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=23969092$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21414438$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mueller, Amy V.</creatorcontrib><creatorcontrib>Hemond, Harold F.</creatorcontrib><title>Towards an automated, standardized protocol for determination of equilibrium potential of ion-selective electrodes</title><title>Analytica chimica acta</title><addtitle>Anal Chim Acta</addtitle><description>An automated real-time method for determination of ISE steady state value and response time is developed, following most recent IUPAC recommendations. Specifically, detection of the ‘steady state’ is related to (1) the time derivative of the emf as it reaches a limiting value (Δ E/Δ t limit, e.g., 0.1–1.0 mV min −1) and (2) the duration of time for which the absolute value of the time derivative remains less than this limiting value (stability window, denoted win st). A suite of representative ISEs, including glass, solid state, and polymer-based electrodes, is examined to determine sensitivity of results to parameterization choice. Measurements taken over a wide range of concentration values and in un-processed samples (i.e., without use of ionic strength adjustment) provide insight into behavior of ISEs in applications where analyte concentrations span a wide range and/or sample pre-processing may not be an option, e.g., use of sensors for in situ environmental sampling. Results show that declared steady state emf is strongly sensitive to variations in Δ E/Δ t limit but relatively unaffected by changes in the stability window when win st ≥30 s. Linearity of calibration curves produced, quantified by root mean squared error (RMSE) against a linear fit, improves as Δ E/Δ t limit decreases, however the percentage of measurements which reach a declared steady state within the prescribed sample window (∼6.5 min) falls with corresponding decreases in the Δ E/Δ t limit parameter. Response time, defined as the time required to reach declared steady emf, is also a strong function of parameterization. Dependence of response times on sample composition and/or ISE membrane composition and type are also discussed; results for ISEs in samples comprised exclusively of interfering ions are included. In general, limiting emf derivatives of {0.25–0.4 mV min −1} and stability windows of {30–40 s} achieve both good analytical accuracy and compliance with potentially short sampling window requirements. Methodology based on use of these parameters can improve sampling speed and accuracy as well as promote inter-comparison of data and ISE characterizations among research teams.</description><subject>Analytical chemistry</subject><subject>Applied sciences</subject><subject>Automation</subject><subject>Chemistry</subject><subject>Electrochemical methods</subject><subject>Equilibration detection</subject><subject>Exact sciences and technology</subject><subject>General, instrumentation</subject><subject>Global environmental pollution</subject><subject>Ion selective electrodes</subject><subject>Pollution</subject><issn>0003-2670</issn><issn>1873-4324</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNqFkU1v1DAQhi0EosuWH9BL5QviQoK_4iTqCVV8SZW4tGdrYk8kr5J4azut4NfjZZf2BqexZ5559WpeQi44qznj-uOuBgu1YJzXTNSlvCAb3rWyUlKol2TDGJOV0C07I29S2pWv4Ey9JmeCK66U7DYk3oZHiC5RWCisOcyQ0X2gKcPiSt__Qkf3MeRgw0THEKnDjHH2C2QfFhpGivern_wQ_TrTfci4ZA_TYVDmVcIJbfYPSP88YnCYzsmrEaaEb091S-6-fL69_lbd_Pj6_frTTWWLuVx1YpAKO8taJWGQiK3WUjTWcj20DLVSYJtmbJvGyYH3LXNOI-ulVBZYj1puyfujbvF_v2LKZvbJ4jTBgmFNptN9p5qm5_8nm7bjWhXtLeFH0saQUsTR7KOfIf40nJlDJmZnSibmkIlhwpRSdi5P6uswo3va-BtCAd6dAEgWpjHCYn165mSve9aLwl0dOSxXe_AYTbIeF4vOx3Jc44L_h43fM12qkw</recordid><startdate>20110325</startdate><enddate>20110325</enddate><creator>Mueller, Amy V.</creator><creator>Hemond, Harold F.</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7ST</scope><scope>C1K</scope><scope>SOI</scope></search><sort><creationdate>20110325</creationdate><title>Towards an automated, standardized protocol for determination of equilibrium potential of ion-selective electrodes</title><author>Mueller, Amy V. ; Hemond, Harold F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c414t-82b34e8c0743ab3ee766325cc16b70e644ac55f755d3b1970dd6e09334ca09e63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Analytical chemistry</topic><topic>Applied sciences</topic><topic>Automation</topic><topic>Chemistry</topic><topic>Electrochemical methods</topic><topic>Equilibration detection</topic><topic>Exact sciences and technology</topic><topic>General, instrumentation</topic><topic>Global environmental pollution</topic><topic>Ion selective electrodes</topic><topic>Pollution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mueller, Amy V.</creatorcontrib><creatorcontrib>Hemond, Harold F.</creatorcontrib><collection>Pascal-Francis</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Environment Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Environment Abstracts</collection><jtitle>Analytica chimica acta</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mueller, Amy V.</au><au>Hemond, Harold F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Towards an automated, standardized protocol for determination of equilibrium potential of ion-selective electrodes</atitle><jtitle>Analytica chimica acta</jtitle><addtitle>Anal Chim Acta</addtitle><date>2011-03-25</date><risdate>2011</risdate><volume>690</volume><issue>1</issue><spage>71</spage><epage>78</epage><pages>71-78</pages><issn>0003-2670</issn><eissn>1873-4324</eissn><coden>ACACAM</coden><abstract>An automated real-time method for determination of ISE steady state value and response time is developed, following most recent IUPAC recommendations. Specifically, detection of the ‘steady state’ is related to (1) the time derivative of the emf as it reaches a limiting value (Δ E/Δ t limit, e.g., 0.1–1.0 mV min −1) and (2) the duration of time for which the absolute value of the time derivative remains less than this limiting value (stability window, denoted win st). A suite of representative ISEs, including glass, solid state, and polymer-based electrodes, is examined to determine sensitivity of results to parameterization choice. Measurements taken over a wide range of concentration values and in un-processed samples (i.e., without use of ionic strength adjustment) provide insight into behavior of ISEs in applications where analyte concentrations span a wide range and/or sample pre-processing may not be an option, e.g., use of sensors for in situ environmental sampling. Results show that declared steady state emf is strongly sensitive to variations in Δ E/Δ t limit but relatively unaffected by changes in the stability window when win st ≥30 s. Linearity of calibration curves produced, quantified by root mean squared error (RMSE) against a linear fit, improves as Δ E/Δ t limit decreases, however the percentage of measurements which reach a declared steady state within the prescribed sample window (∼6.5 min) falls with corresponding decreases in the Δ E/Δ t limit parameter. Response time, defined as the time required to reach declared steady emf, is also a strong function of parameterization. Dependence of response times on sample composition and/or ISE membrane composition and type are also discussed; results for ISEs in samples comprised exclusively of interfering ions are included. In general, limiting emf derivatives of {0.25–0.4 mV min −1} and stability windows of {30–40 s} achieve both good analytical accuracy and compliance with potentially short sampling window requirements. Methodology based on use of these parameters can improve sampling speed and accuracy as well as promote inter-comparison of data and ISE characterizations among research teams.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>21414438</pmid><doi>10.1016/j.aca.2011.02.011</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0003-2670
ispartof Analytica chimica acta, 2011-03, Vol.690 (1), p.71-78
issn 0003-2670
1873-4324
language eng
recordid cdi_proquest_miscellaneous_869845591
source Elsevier ScienceDirect Journals
subjects Analytical chemistry
Applied sciences
Automation
Chemistry
Electrochemical methods
Equilibration detection
Exact sciences and technology
General, instrumentation
Global environmental pollution
Ion selective electrodes
Pollution
title Towards an automated, standardized protocol for determination of equilibrium potential of ion-selective electrodes
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-01T19%3A50%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Towards%20an%20automated,%20standardized%20protocol%20for%20determination%20of%20equilibrium%20potential%20of%20ion-selective%20electrodes&rft.jtitle=Analytica%20chimica%20acta&rft.au=Mueller,%20Amy%20V.&rft.date=2011-03-25&rft.volume=690&rft.issue=1&rft.spage=71&rft.epage=78&rft.pages=71-78&rft.issn=0003-2670&rft.eissn=1873-4324&rft.coden=ACACAM&rft_id=info:doi/10.1016/j.aca.2011.02.011&rft_dat=%3Cproquest_cross%3E869845591%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=857816493&rft_id=info:pmid/21414438&rft_els_id=S0003267011001838&rfr_iscdi=true