The effect of microcolumn geometry on the performance of micro-gas chromatography columns for chip scale gas analyzers
Many microfabricated gas chromatography (micro-GC) column designs have been reported so far, but it is unclear how microcolumn design affects separation performance in the typical isothermal or temperature-programmed mode of operation. This paper compares the separation performance of microfabricate...
Gespeichert in:
Veröffentlicht in: | Sensors and actuators. B, Chemical Chemical, 2010-09, Vol.150 (1), p.456-464 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 464 |
---|---|
container_issue | 1 |
container_start_page | 456 |
container_title | Sensors and actuators. B, Chemical |
container_volume | 150 |
creator | Radadia, A.D. Salehi-Khojin, A. Masel, R.I. Shannon, M.A. |
description | Many microfabricated gas chromatography (micro-GC) column designs have been reported so far, but it is unclear how microcolumn design affects separation performance in the typical isothermal or temperature-programmed mode of operation. This paper compares the separation performance of microfabricated serpentine, circular-spiral and square-spiral columns in both modes of operation. Experimentally although all the geometries have similar gas permeability and unretained solute band broadening, it is shown that the serpentine columns show higher separation plate numbers (lower band broadening) for retained solutes in isothermal mode of operation compared to circular- or square-spiral configurations. Also in temperature-programmed mode of operation, the serpentine design yields higher separation numbers (peak–peak resolution) compared to spiral configurations. The advantage of using a serpentine configuration is clearly evident especially in the velocity range of 15–40
cm/s in either operation modes, and independent of the temperature programming rate in temperature-programmed mode. An exemplary mix of 33 chemicals was used to demonstrate the higher speed and resolution of practically relevant separations on serpentine column. |
doi_str_mv | 10.1016/j.snb.2010.07.002 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_869566883</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0925400510005770</els_id><sourcerecordid>869566883</sourcerecordid><originalsourceid>FETCH-LOGICAL-c329t-6d061ad535141bb7835dabdd97b940c32fae466603e9c4fe5d7fa609c34728f83</originalsourceid><addsrcrecordid>eNp9kMtqwzAQRUVpoenjA7rTriunI8uWbLoqoS8IdJOuhSyPEgfbciUn4H59FVy67GoY5tyBewi5Y7BkwMTDfhn6aplC3EEuAdIzsmCF5AkHKc_JAso0TzKA_JJchbAHgIwLWJDjZocUrUUzUmdp1xjvjGsPXU-36Doc_URdT8dIDeit853uDf6hyVYHanbedXp0W6-H3UTneKARjqdmoMHoFumJ1L1up2_04YZcWN0GvP2d1-Tz5XmzekvWH6_vq6d1YnhajomoQTBd5zxnGasqWfC81lVdl7IqM4iM1ZgJIYBjaTKLeS2tFlAansm0sAW_Jvfz38G7rwOGUXVNMNi2ukd3CKoQZS5EUfBIspmMrULwaNXgm077STFQJ8Vqr6JidVKsQKqoOGYe5wzGCscGvQqmweinbnwUqmrX_JP-AZjchlc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>869566883</pqid></control><display><type>article</type><title>The effect of microcolumn geometry on the performance of micro-gas chromatography columns for chip scale gas analyzers</title><source>Elsevier ScienceDirect Journals</source><creator>Radadia, A.D. ; Salehi-Khojin, A. ; Masel, R.I. ; Shannon, M.A.</creator><creatorcontrib>Radadia, A.D. ; Salehi-Khojin, A. ; Masel, R.I. ; Shannon, M.A.</creatorcontrib><description>Many microfabricated gas chromatography (micro-GC) column designs have been reported so far, but it is unclear how microcolumn design affects separation performance in the typical isothermal or temperature-programmed mode of operation. This paper compares the separation performance of microfabricated serpentine, circular-spiral and square-spiral columns in both modes of operation. Experimentally although all the geometries have similar gas permeability and unretained solute band broadening, it is shown that the serpentine columns show higher separation plate numbers (lower band broadening) for retained solutes in isothermal mode of operation compared to circular- or square-spiral configurations. Also in temperature-programmed mode of operation, the serpentine design yields higher separation numbers (peak–peak resolution) compared to spiral configurations. The advantage of using a serpentine configuration is clearly evident especially in the velocity range of 15–40
cm/s in either operation modes, and independent of the temperature programming rate in temperature-programmed mode. An exemplary mix of 33 chemicals was used to demonstrate the higher speed and resolution of practically relevant separations on serpentine column.</description><identifier>ISSN: 0925-4005</identifier><identifier>EISSN: 1873-3077</identifier><identifier>DOI: 10.1016/j.snb.2010.07.002</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Actuators ; Chromatography ; Circularity ; High resolution GC ; Micro-GC ; Microcolumns ; Permeability ; Programming ; Separation ; Serpentine ; Silicon GC column ; Solute bands</subject><ispartof>Sensors and actuators. B, Chemical, 2010-09, Vol.150 (1), p.456-464</ispartof><rights>2010 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c329t-6d061ad535141bb7835dabdd97b940c32fae466603e9c4fe5d7fa609c34728f83</citedby><cites>FETCH-LOGICAL-c329t-6d061ad535141bb7835dabdd97b940c32fae466603e9c4fe5d7fa609c34728f83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0925400510005770$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Radadia, A.D.</creatorcontrib><creatorcontrib>Salehi-Khojin, A.</creatorcontrib><creatorcontrib>Masel, R.I.</creatorcontrib><creatorcontrib>Shannon, M.A.</creatorcontrib><title>The effect of microcolumn geometry on the performance of micro-gas chromatography columns for chip scale gas analyzers</title><title>Sensors and actuators. B, Chemical</title><description>Many microfabricated gas chromatography (micro-GC) column designs have been reported so far, but it is unclear how microcolumn design affects separation performance in the typical isothermal or temperature-programmed mode of operation. This paper compares the separation performance of microfabricated serpentine, circular-spiral and square-spiral columns in both modes of operation. Experimentally although all the geometries have similar gas permeability and unretained solute band broadening, it is shown that the serpentine columns show higher separation plate numbers (lower band broadening) for retained solutes in isothermal mode of operation compared to circular- or square-spiral configurations. Also in temperature-programmed mode of operation, the serpentine design yields higher separation numbers (peak–peak resolution) compared to spiral configurations. The advantage of using a serpentine configuration is clearly evident especially in the velocity range of 15–40
cm/s in either operation modes, and independent of the temperature programming rate in temperature-programmed mode. An exemplary mix of 33 chemicals was used to demonstrate the higher speed and resolution of practically relevant separations on serpentine column.</description><subject>Actuators</subject><subject>Chromatography</subject><subject>Circularity</subject><subject>High resolution GC</subject><subject>Micro-GC</subject><subject>Microcolumns</subject><subject>Permeability</subject><subject>Programming</subject><subject>Separation</subject><subject>Serpentine</subject><subject>Silicon GC column</subject><subject>Solute bands</subject><issn>0925-4005</issn><issn>1873-3077</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNp9kMtqwzAQRUVpoenjA7rTriunI8uWbLoqoS8IdJOuhSyPEgfbciUn4H59FVy67GoY5tyBewi5Y7BkwMTDfhn6aplC3EEuAdIzsmCF5AkHKc_JAso0TzKA_JJchbAHgIwLWJDjZocUrUUzUmdp1xjvjGsPXU-36Doc_URdT8dIDeit853uDf6hyVYHanbedXp0W6-H3UTneKARjqdmoMHoFumJ1L1up2_04YZcWN0GvP2d1-Tz5XmzekvWH6_vq6d1YnhajomoQTBd5zxnGasqWfC81lVdl7IqM4iM1ZgJIYBjaTKLeS2tFlAansm0sAW_Jvfz38G7rwOGUXVNMNi2ukd3CKoQZS5EUfBIspmMrULwaNXgm077STFQJ8Vqr6JidVKsQKqoOGYe5wzGCscGvQqmweinbnwUqmrX_JP-AZjchlc</recordid><startdate>20100921</startdate><enddate>20100921</enddate><creator>Radadia, A.D.</creator><creator>Salehi-Khojin, A.</creator><creator>Masel, R.I.</creator><creator>Shannon, M.A.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope></search><sort><creationdate>20100921</creationdate><title>The effect of microcolumn geometry on the performance of micro-gas chromatography columns for chip scale gas analyzers</title><author>Radadia, A.D. ; Salehi-Khojin, A. ; Masel, R.I. ; Shannon, M.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c329t-6d061ad535141bb7835dabdd97b940c32fae466603e9c4fe5d7fa609c34728f83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Actuators</topic><topic>Chromatography</topic><topic>Circularity</topic><topic>High resolution GC</topic><topic>Micro-GC</topic><topic>Microcolumns</topic><topic>Permeability</topic><topic>Programming</topic><topic>Separation</topic><topic>Serpentine</topic><topic>Silicon GC column</topic><topic>Solute bands</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Radadia, A.D.</creatorcontrib><creatorcontrib>Salehi-Khojin, A.</creatorcontrib><creatorcontrib>Masel, R.I.</creatorcontrib><creatorcontrib>Shannon, M.A.</creatorcontrib><collection>CrossRef</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Sensors and actuators. B, Chemical</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Radadia, A.D.</au><au>Salehi-Khojin, A.</au><au>Masel, R.I.</au><au>Shannon, M.A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The effect of microcolumn geometry on the performance of micro-gas chromatography columns for chip scale gas analyzers</atitle><jtitle>Sensors and actuators. B, Chemical</jtitle><date>2010-09-21</date><risdate>2010</risdate><volume>150</volume><issue>1</issue><spage>456</spage><epage>464</epage><pages>456-464</pages><issn>0925-4005</issn><eissn>1873-3077</eissn><abstract>Many microfabricated gas chromatography (micro-GC) column designs have been reported so far, but it is unclear how microcolumn design affects separation performance in the typical isothermal or temperature-programmed mode of operation. This paper compares the separation performance of microfabricated serpentine, circular-spiral and square-spiral columns in both modes of operation. Experimentally although all the geometries have similar gas permeability and unretained solute band broadening, it is shown that the serpentine columns show higher separation plate numbers (lower band broadening) for retained solutes in isothermal mode of operation compared to circular- or square-spiral configurations. Also in temperature-programmed mode of operation, the serpentine design yields higher separation numbers (peak–peak resolution) compared to spiral configurations. The advantage of using a serpentine configuration is clearly evident especially in the velocity range of 15–40
cm/s in either operation modes, and independent of the temperature programming rate in temperature-programmed mode. An exemplary mix of 33 chemicals was used to demonstrate the higher speed and resolution of practically relevant separations on serpentine column.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.snb.2010.07.002</doi><tpages>9</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0925-4005 |
ispartof | Sensors and actuators. B, Chemical, 2010-09, Vol.150 (1), p.456-464 |
issn | 0925-4005 1873-3077 |
language | eng |
recordid | cdi_proquest_miscellaneous_869566883 |
source | Elsevier ScienceDirect Journals |
subjects | Actuators Chromatography Circularity High resolution GC Micro-GC Microcolumns Permeability Programming Separation Serpentine Silicon GC column Solute bands |
title | The effect of microcolumn geometry on the performance of micro-gas chromatography columns for chip scale gas analyzers |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T19%3A28%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20effect%20of%20microcolumn%20geometry%20on%20the%20performance%20of%20micro-gas%20chromatography%20columns%20for%20chip%20scale%20gas%20analyzers&rft.jtitle=Sensors%20and%20actuators.%20B,%20Chemical&rft.au=Radadia,%20A.D.&rft.date=2010-09-21&rft.volume=150&rft.issue=1&rft.spage=456&rft.epage=464&rft.pages=456-464&rft.issn=0925-4005&rft.eissn=1873-3077&rft_id=info:doi/10.1016/j.snb.2010.07.002&rft_dat=%3Cproquest_cross%3E869566883%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=869566883&rft_id=info:pmid/&rft_els_id=S0925400510005770&rfr_iscdi=true |