The effect of microcolumn geometry on the performance of micro-gas chromatography columns for chip scale gas analyzers

Many microfabricated gas chromatography (micro-GC) column designs have been reported so far, but it is unclear how microcolumn design affects separation performance in the typical isothermal or temperature-programmed mode of operation. This paper compares the separation performance of microfabricate...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. B, Chemical Chemical, 2010-09, Vol.150 (1), p.456-464
Hauptverfasser: Radadia, A.D., Salehi-Khojin, A., Masel, R.I., Shannon, M.A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 464
container_issue 1
container_start_page 456
container_title Sensors and actuators. B, Chemical
container_volume 150
creator Radadia, A.D.
Salehi-Khojin, A.
Masel, R.I.
Shannon, M.A.
description Many microfabricated gas chromatography (micro-GC) column designs have been reported so far, but it is unclear how microcolumn design affects separation performance in the typical isothermal or temperature-programmed mode of operation. This paper compares the separation performance of microfabricated serpentine, circular-spiral and square-spiral columns in both modes of operation. Experimentally although all the geometries have similar gas permeability and unretained solute band broadening, it is shown that the serpentine columns show higher separation plate numbers (lower band broadening) for retained solutes in isothermal mode of operation compared to circular- or square-spiral configurations. Also in temperature-programmed mode of operation, the serpentine design yields higher separation numbers (peak–peak resolution) compared to spiral configurations. The advantage of using a serpentine configuration is clearly evident especially in the velocity range of 15–40 cm/s in either operation modes, and independent of the temperature programming rate in temperature-programmed mode. An exemplary mix of 33 chemicals was used to demonstrate the higher speed and resolution of practically relevant separations on serpentine column.
doi_str_mv 10.1016/j.snb.2010.07.002
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_869566883</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0925400510005770</els_id><sourcerecordid>869566883</sourcerecordid><originalsourceid>FETCH-LOGICAL-c329t-6d061ad535141bb7835dabdd97b940c32fae466603e9c4fe5d7fa609c34728f83</originalsourceid><addsrcrecordid>eNp9kMtqwzAQRUVpoenjA7rTriunI8uWbLoqoS8IdJOuhSyPEgfbciUn4H59FVy67GoY5tyBewi5Y7BkwMTDfhn6aplC3EEuAdIzsmCF5AkHKc_JAso0TzKA_JJchbAHgIwLWJDjZocUrUUzUmdp1xjvjGsPXU-36Doc_URdT8dIDeit853uDf6hyVYHanbedXp0W6-H3UTneKARjqdmoMHoFumJ1L1up2_04YZcWN0GvP2d1-Tz5XmzekvWH6_vq6d1YnhajomoQTBd5zxnGasqWfC81lVdl7IqM4iM1ZgJIYBjaTKLeS2tFlAansm0sAW_Jvfz38G7rwOGUXVNMNi2ukd3CKoQZS5EUfBIspmMrULwaNXgm077STFQJ8Vqr6JidVKsQKqoOGYe5wzGCscGvQqmweinbnwUqmrX_JP-AZjchlc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>869566883</pqid></control><display><type>article</type><title>The effect of microcolumn geometry on the performance of micro-gas chromatography columns for chip scale gas analyzers</title><source>Elsevier ScienceDirect Journals</source><creator>Radadia, A.D. ; Salehi-Khojin, A. ; Masel, R.I. ; Shannon, M.A.</creator><creatorcontrib>Radadia, A.D. ; Salehi-Khojin, A. ; Masel, R.I. ; Shannon, M.A.</creatorcontrib><description>Many microfabricated gas chromatography (micro-GC) column designs have been reported so far, but it is unclear how microcolumn design affects separation performance in the typical isothermal or temperature-programmed mode of operation. This paper compares the separation performance of microfabricated serpentine, circular-spiral and square-spiral columns in both modes of operation. Experimentally although all the geometries have similar gas permeability and unretained solute band broadening, it is shown that the serpentine columns show higher separation plate numbers (lower band broadening) for retained solutes in isothermal mode of operation compared to circular- or square-spiral configurations. Also in temperature-programmed mode of operation, the serpentine design yields higher separation numbers (peak–peak resolution) compared to spiral configurations. The advantage of using a serpentine configuration is clearly evident especially in the velocity range of 15–40 cm/s in either operation modes, and independent of the temperature programming rate in temperature-programmed mode. An exemplary mix of 33 chemicals was used to demonstrate the higher speed and resolution of practically relevant separations on serpentine column.</description><identifier>ISSN: 0925-4005</identifier><identifier>EISSN: 1873-3077</identifier><identifier>DOI: 10.1016/j.snb.2010.07.002</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Actuators ; Chromatography ; Circularity ; High resolution GC ; Micro-GC ; Microcolumns ; Permeability ; Programming ; Separation ; Serpentine ; Silicon GC column ; Solute bands</subject><ispartof>Sensors and actuators. B, Chemical, 2010-09, Vol.150 (1), p.456-464</ispartof><rights>2010 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c329t-6d061ad535141bb7835dabdd97b940c32fae466603e9c4fe5d7fa609c34728f83</citedby><cites>FETCH-LOGICAL-c329t-6d061ad535141bb7835dabdd97b940c32fae466603e9c4fe5d7fa609c34728f83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0925400510005770$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids></links><search><creatorcontrib>Radadia, A.D.</creatorcontrib><creatorcontrib>Salehi-Khojin, A.</creatorcontrib><creatorcontrib>Masel, R.I.</creatorcontrib><creatorcontrib>Shannon, M.A.</creatorcontrib><title>The effect of microcolumn geometry on the performance of micro-gas chromatography columns for chip scale gas analyzers</title><title>Sensors and actuators. B, Chemical</title><description>Many microfabricated gas chromatography (micro-GC) column designs have been reported so far, but it is unclear how microcolumn design affects separation performance in the typical isothermal or temperature-programmed mode of operation. This paper compares the separation performance of microfabricated serpentine, circular-spiral and square-spiral columns in both modes of operation. Experimentally although all the geometries have similar gas permeability and unretained solute band broadening, it is shown that the serpentine columns show higher separation plate numbers (lower band broadening) for retained solutes in isothermal mode of operation compared to circular- or square-spiral configurations. Also in temperature-programmed mode of operation, the serpentine design yields higher separation numbers (peak–peak resolution) compared to spiral configurations. The advantage of using a serpentine configuration is clearly evident especially in the velocity range of 15–40 cm/s in either operation modes, and independent of the temperature programming rate in temperature-programmed mode. An exemplary mix of 33 chemicals was used to demonstrate the higher speed and resolution of practically relevant separations on serpentine column.</description><subject>Actuators</subject><subject>Chromatography</subject><subject>Circularity</subject><subject>High resolution GC</subject><subject>Micro-GC</subject><subject>Microcolumns</subject><subject>Permeability</subject><subject>Programming</subject><subject>Separation</subject><subject>Serpentine</subject><subject>Silicon GC column</subject><subject>Solute bands</subject><issn>0925-4005</issn><issn>1873-3077</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNp9kMtqwzAQRUVpoenjA7rTriunI8uWbLoqoS8IdJOuhSyPEgfbciUn4H59FVy67GoY5tyBewi5Y7BkwMTDfhn6aplC3EEuAdIzsmCF5AkHKc_JAso0TzKA_JJchbAHgIwLWJDjZocUrUUzUmdp1xjvjGsPXU-36Doc_URdT8dIDeit853uDf6hyVYHanbedXp0W6-H3UTneKARjqdmoMHoFumJ1L1up2_04YZcWN0GvP2d1-Tz5XmzekvWH6_vq6d1YnhajomoQTBd5zxnGasqWfC81lVdl7IqM4iM1ZgJIYBjaTKLeS2tFlAansm0sAW_Jvfz38G7rwOGUXVNMNi2ukd3CKoQZS5EUfBIspmMrULwaNXgm077STFQJ8Vqr6JidVKsQKqoOGYe5wzGCscGvQqmweinbnwUqmrX_JP-AZjchlc</recordid><startdate>20100921</startdate><enddate>20100921</enddate><creator>Radadia, A.D.</creator><creator>Salehi-Khojin, A.</creator><creator>Masel, R.I.</creator><creator>Shannon, M.A.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>7U5</scope><scope>8FD</scope><scope>FR3</scope><scope>L7M</scope></search><sort><creationdate>20100921</creationdate><title>The effect of microcolumn geometry on the performance of micro-gas chromatography columns for chip scale gas analyzers</title><author>Radadia, A.D. ; Salehi-Khojin, A. ; Masel, R.I. ; Shannon, M.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c329t-6d061ad535141bb7835dabdd97b940c32fae466603e9c4fe5d7fa609c34728f83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Actuators</topic><topic>Chromatography</topic><topic>Circularity</topic><topic>High resolution GC</topic><topic>Micro-GC</topic><topic>Microcolumns</topic><topic>Permeability</topic><topic>Programming</topic><topic>Separation</topic><topic>Serpentine</topic><topic>Silicon GC column</topic><topic>Solute bands</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Radadia, A.D.</creatorcontrib><creatorcontrib>Salehi-Khojin, A.</creatorcontrib><creatorcontrib>Masel, R.I.</creatorcontrib><creatorcontrib>Shannon, M.A.</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Sensors and actuators. B, Chemical</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Radadia, A.D.</au><au>Salehi-Khojin, A.</au><au>Masel, R.I.</au><au>Shannon, M.A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The effect of microcolumn geometry on the performance of micro-gas chromatography columns for chip scale gas analyzers</atitle><jtitle>Sensors and actuators. B, Chemical</jtitle><date>2010-09-21</date><risdate>2010</risdate><volume>150</volume><issue>1</issue><spage>456</spage><epage>464</epage><pages>456-464</pages><issn>0925-4005</issn><eissn>1873-3077</eissn><abstract>Many microfabricated gas chromatography (micro-GC) column designs have been reported so far, but it is unclear how microcolumn design affects separation performance in the typical isothermal or temperature-programmed mode of operation. This paper compares the separation performance of microfabricated serpentine, circular-spiral and square-spiral columns in both modes of operation. Experimentally although all the geometries have similar gas permeability and unretained solute band broadening, it is shown that the serpentine columns show higher separation plate numbers (lower band broadening) for retained solutes in isothermal mode of operation compared to circular- or square-spiral configurations. Also in temperature-programmed mode of operation, the serpentine design yields higher separation numbers (peak–peak resolution) compared to spiral configurations. The advantage of using a serpentine configuration is clearly evident especially in the velocity range of 15–40 cm/s in either operation modes, and independent of the temperature programming rate in temperature-programmed mode. An exemplary mix of 33 chemicals was used to demonstrate the higher speed and resolution of practically relevant separations on serpentine column.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.snb.2010.07.002</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0925-4005
ispartof Sensors and actuators. B, Chemical, 2010-09, Vol.150 (1), p.456-464
issn 0925-4005
1873-3077
language eng
recordid cdi_proquest_miscellaneous_869566883
source Elsevier ScienceDirect Journals
subjects Actuators
Chromatography
Circularity
High resolution GC
Micro-GC
Microcolumns
Permeability
Programming
Separation
Serpentine
Silicon GC column
Solute bands
title The effect of microcolumn geometry on the performance of micro-gas chromatography columns for chip scale gas analyzers
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-28T19%3A28%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20effect%20of%20microcolumn%20geometry%20on%20the%20performance%20of%20micro-gas%20chromatography%20columns%20for%20chip%20scale%20gas%20analyzers&rft.jtitle=Sensors%20and%20actuators.%20B,%20Chemical&rft.au=Radadia,%20A.D.&rft.date=2010-09-21&rft.volume=150&rft.issue=1&rft.spage=456&rft.epage=464&rft.pages=456-464&rft.issn=0925-4005&rft.eissn=1873-3077&rft_id=info:doi/10.1016/j.snb.2010.07.002&rft_dat=%3Cproquest_cross%3E869566883%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=869566883&rft_id=info:pmid/&rft_els_id=S0925400510005770&rfr_iscdi=true