Impact of CO2, N2 or Ar diluted in air on the length and lifting behavior of a laminar diffusion flame
Air-side dilution on laminar methane/air diffusion flames in the buoyant regime was extensively studied. CO2, important for EGR and fire safety, was chosen as a diluent. It was complemented by N2 and Ar. Flame stability, its external aspect and inner structure were quantified by complementary experi...
Gespeichert in:
Veröffentlicht in: | Proceedings of the Combustion Institute 2011, Vol.33 (1), p.1071-1078 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1078 |
---|---|
container_issue | 1 |
container_start_page | 1071 |
container_title | Proceedings of the Combustion Institute |
container_volume | 33 |
creator | Min, Jiesheng Baillot, Françoise Guo, Hongsheng Domingues, Eric Talbaut, Martine Patte-Rouland, Béatrice |
description | Air-side dilution on laminar methane/air diffusion flames in the buoyant regime was extensively studied. CO2, important for EGR and fire safety, was chosen as a diluent. It was complemented by N2 and Ar. Flame stability, its external aspect and inner structure were quantified by complementary experiments and simulations. Two flame-response categories were highlighted, depending on whether mechanisms relied on several effects or mainly on pure dilution. In the former case, physico-chemical properties of diluents were essential. The greatest influence was detected with CO2, the least one with Ar. No critical value of the initial molar O2-concentration (XO2,i) was found to control quantities involved in stability (lifting limit, standoff distance of the attached flame), soot formation and flame-tip opening. It was found a critical flow-rate ratio from which flame-liftoff always occurred, crucial to describe lifting process induced by dilution. The reaction, naturally weak at the flame tip, led to an apparent open-tip with diluents. However, simulation showed the reaction, even weakened, persisted. On the contrary, pure dilution controlled flame length behavior. When XO2,i was decreased, length increased according to a unique evolution whatever the diluents. To measure flame length, several techniques were applied: OH Planar Laser Induced Fluorescence (Lf,OH), soot-Laser Induced Incandescence (Lf,LII), direct flame emission (Lf,luminous and Lf,peak). Length Lf,luminous was unable to correctly characterize flame lengthening. Lf,peak was the closest to the calculated stoichiometric length. So, the method giving Lf,peak appeared as the easiest and the most accurate one. Comparison between our data and correlations found in literature indicated Roper’s correlation was the most efficient to predict length evolution. |
doi_str_mv | 10.1016/j.proci.2010.06.100 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_864407857</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1540748910001732</els_id><sourcerecordid>864407857</sourcerecordid><originalsourceid>FETCH-LOGICAL-c250t-c7b1ee72f8800a280f0f917f2343282441ce310a1e2daf0ebd3b11993fc6073a3</originalsourceid><addsrcrecordid>eNp9kD1PwzAQhiMEEqXwC1i8sZBy_kicDgxVxZdU0QVmy3HOravEKXZSiX-PS5mZ7vTqfU66J8tuKcwo0PJhN9uH3rgZg5RAmUI4yya0kjxnEsR52gsBuRTV_DK7inEHwCXwYpLZt26vzUB6S5Zrdk_eGekDWQTSuHYcsCHOE-0C6T0Ztkha9JthS7RvSOvs4PyG1LjVB5egdEKTVnfO6yNu7RhdwmyK8Dq7sLqNePM3p9nn89PH8jVfrV_elotVblgBQ25kTREls1UFoFkFFuycSsu44KxiQlCDnIKmyBptAeuG15TO59yaEiTXfJrdne4mH18jxkF1LhpsW-2xH6OqSiFAVoVMTX5qmtDHGNCqfXCdDt-KgjpKVTv1K1UdpSooUwiJejxRmJ44OAwqGofeYOMCmkE1vfuX_wGOzn-X</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>864407857</pqid></control><display><type>article</type><title>Impact of CO2, N2 or Ar diluted in air on the length and lifting behavior of a laminar diffusion flame</title><source>Elsevier ScienceDirect Journals</source><creator>Min, Jiesheng ; Baillot, Françoise ; Guo, Hongsheng ; Domingues, Eric ; Talbaut, Martine ; Patte-Rouland, Béatrice</creator><creatorcontrib>Min, Jiesheng ; Baillot, Françoise ; Guo, Hongsheng ; Domingues, Eric ; Talbaut, Martine ; Patte-Rouland, Béatrice</creatorcontrib><description>Air-side dilution on laminar methane/air diffusion flames in the buoyant regime was extensively studied. CO2, important for EGR and fire safety, was chosen as a diluent. It was complemented by N2 and Ar. Flame stability, its external aspect and inner structure were quantified by complementary experiments and simulations. Two flame-response categories were highlighted, depending on whether mechanisms relied on several effects or mainly on pure dilution. In the former case, physico-chemical properties of diluents were essential. The greatest influence was detected with CO2, the least one with Ar. No critical value of the initial molar O2-concentration (XO2,i) was found to control quantities involved in stability (lifting limit, standoff distance of the attached flame), soot formation and flame-tip opening. It was found a critical flow-rate ratio from which flame-liftoff always occurred, crucial to describe lifting process induced by dilution. The reaction, naturally weak at the flame tip, led to an apparent open-tip with diluents. However, simulation showed the reaction, even weakened, persisted. On the contrary, pure dilution controlled flame length behavior. When XO2,i was decreased, length increased according to a unique evolution whatever the diluents. To measure flame length, several techniques were applied: OH Planar Laser Induced Fluorescence (Lf,OH), soot-Laser Induced Incandescence (Lf,LII), direct flame emission (Lf,luminous and Lf,peak). Length Lf,luminous was unable to correctly characterize flame lengthening. Lf,peak was the closest to the calculated stoichiometric length. So, the method giving Lf,peak appeared as the easiest and the most accurate one. Comparison between our data and correlations found in literature indicated Roper’s correlation was the most efficient to predict length evolution.</description><identifier>ISSN: 1540-7489</identifier><identifier>EISSN: 1873-2704</identifier><identifier>DOI: 10.1016/j.proci.2010.06.100</identifier><language>eng</language><publisher>Elsevier Inc</publisher><subject>Carbon dioxide ; CH4/air ; CO2 dilution ; Combustion ; Correlation ; Diffusion flames ; Evolution ; Flame length ; Hoisting ; Laminar ; Laminar diffusion flame ; Liftoff ; Simulation</subject><ispartof>Proceedings of the Combustion Institute, 2011, Vol.33 (1), p.1071-1078</ispartof><rights>2010 The Combustion Institute</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c250t-c7b1ee72f8800a280f0f917f2343282441ce310a1e2daf0ebd3b11993fc6073a3</citedby><cites>FETCH-LOGICAL-c250t-c7b1ee72f8800a280f0f917f2343282441ce310a1e2daf0ebd3b11993fc6073a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S1540748910001732$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,4010,27900,27901,27902,65534</link.rule.ids></links><search><creatorcontrib>Min, Jiesheng</creatorcontrib><creatorcontrib>Baillot, Françoise</creatorcontrib><creatorcontrib>Guo, Hongsheng</creatorcontrib><creatorcontrib>Domingues, Eric</creatorcontrib><creatorcontrib>Talbaut, Martine</creatorcontrib><creatorcontrib>Patte-Rouland, Béatrice</creatorcontrib><title>Impact of CO2, N2 or Ar diluted in air on the length and lifting behavior of a laminar diffusion flame</title><title>Proceedings of the Combustion Institute</title><description>Air-side dilution on laminar methane/air diffusion flames in the buoyant regime was extensively studied. CO2, important for EGR and fire safety, was chosen as a diluent. It was complemented by N2 and Ar. Flame stability, its external aspect and inner structure were quantified by complementary experiments and simulations. Two flame-response categories were highlighted, depending on whether mechanisms relied on several effects or mainly on pure dilution. In the former case, physico-chemical properties of diluents were essential. The greatest influence was detected with CO2, the least one with Ar. No critical value of the initial molar O2-concentration (XO2,i) was found to control quantities involved in stability (lifting limit, standoff distance of the attached flame), soot formation and flame-tip opening. It was found a critical flow-rate ratio from which flame-liftoff always occurred, crucial to describe lifting process induced by dilution. The reaction, naturally weak at the flame tip, led to an apparent open-tip with diluents. However, simulation showed the reaction, even weakened, persisted. On the contrary, pure dilution controlled flame length behavior. When XO2,i was decreased, length increased according to a unique evolution whatever the diluents. To measure flame length, several techniques were applied: OH Planar Laser Induced Fluorescence (Lf,OH), soot-Laser Induced Incandescence (Lf,LII), direct flame emission (Lf,luminous and Lf,peak). Length Lf,luminous was unable to correctly characterize flame lengthening. Lf,peak was the closest to the calculated stoichiometric length. So, the method giving Lf,peak appeared as the easiest and the most accurate one. Comparison between our data and correlations found in literature indicated Roper’s correlation was the most efficient to predict length evolution.</description><subject>Carbon dioxide</subject><subject>CH4/air</subject><subject>CO2 dilution</subject><subject>Combustion</subject><subject>Correlation</subject><subject>Diffusion flames</subject><subject>Evolution</subject><subject>Flame length</subject><subject>Hoisting</subject><subject>Laminar</subject><subject>Laminar diffusion flame</subject><subject>Liftoff</subject><subject>Simulation</subject><issn>1540-7489</issn><issn>1873-2704</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNp9kD1PwzAQhiMEEqXwC1i8sZBy_kicDgxVxZdU0QVmy3HOravEKXZSiX-PS5mZ7vTqfU66J8tuKcwo0PJhN9uH3rgZg5RAmUI4yya0kjxnEsR52gsBuRTV_DK7inEHwCXwYpLZt26vzUB6S5Zrdk_eGekDWQTSuHYcsCHOE-0C6T0Ztkha9JthS7RvSOvs4PyG1LjVB5egdEKTVnfO6yNu7RhdwmyK8Dq7sLqNePM3p9nn89PH8jVfrV_elotVblgBQ25kTREls1UFoFkFFuycSsu44KxiQlCDnIKmyBptAeuG15TO59yaEiTXfJrdne4mH18jxkF1LhpsW-2xH6OqSiFAVoVMTX5qmtDHGNCqfXCdDt-KgjpKVTv1K1UdpSooUwiJejxRmJ44OAwqGofeYOMCmkE1vfuX_wGOzn-X</recordid><startdate>2011</startdate><enddate>2011</enddate><creator>Min, Jiesheng</creator><creator>Baillot, Françoise</creator><creator>Guo, Hongsheng</creator><creator>Domingues, Eric</creator><creator>Talbaut, Martine</creator><creator>Patte-Rouland, Béatrice</creator><general>Elsevier Inc</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>2011</creationdate><title>Impact of CO2, N2 or Ar diluted in air on the length and lifting behavior of a laminar diffusion flame</title><author>Min, Jiesheng ; Baillot, Françoise ; Guo, Hongsheng ; Domingues, Eric ; Talbaut, Martine ; Patte-Rouland, Béatrice</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c250t-c7b1ee72f8800a280f0f917f2343282441ce310a1e2daf0ebd3b11993fc6073a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Carbon dioxide</topic><topic>CH4/air</topic><topic>CO2 dilution</topic><topic>Combustion</topic><topic>Correlation</topic><topic>Diffusion flames</topic><topic>Evolution</topic><topic>Flame length</topic><topic>Hoisting</topic><topic>Laminar</topic><topic>Laminar diffusion flame</topic><topic>Liftoff</topic><topic>Simulation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Min, Jiesheng</creatorcontrib><creatorcontrib>Baillot, Françoise</creatorcontrib><creatorcontrib>Guo, Hongsheng</creatorcontrib><creatorcontrib>Domingues, Eric</creatorcontrib><creatorcontrib>Talbaut, Martine</creatorcontrib><creatorcontrib>Patte-Rouland, Béatrice</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Proceedings of the Combustion Institute</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Min, Jiesheng</au><au>Baillot, Françoise</au><au>Guo, Hongsheng</au><au>Domingues, Eric</au><au>Talbaut, Martine</au><au>Patte-Rouland, Béatrice</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Impact of CO2, N2 or Ar diluted in air on the length and lifting behavior of a laminar diffusion flame</atitle><jtitle>Proceedings of the Combustion Institute</jtitle><date>2011</date><risdate>2011</risdate><volume>33</volume><issue>1</issue><spage>1071</spage><epage>1078</epage><pages>1071-1078</pages><issn>1540-7489</issn><eissn>1873-2704</eissn><abstract>Air-side dilution on laminar methane/air diffusion flames in the buoyant regime was extensively studied. CO2, important for EGR and fire safety, was chosen as a diluent. It was complemented by N2 and Ar. Flame stability, its external aspect and inner structure were quantified by complementary experiments and simulations. Two flame-response categories were highlighted, depending on whether mechanisms relied on several effects or mainly on pure dilution. In the former case, physico-chemical properties of diluents were essential. The greatest influence was detected with CO2, the least one with Ar. No critical value of the initial molar O2-concentration (XO2,i) was found to control quantities involved in stability (lifting limit, standoff distance of the attached flame), soot formation and flame-tip opening. It was found a critical flow-rate ratio from which flame-liftoff always occurred, crucial to describe lifting process induced by dilution. The reaction, naturally weak at the flame tip, led to an apparent open-tip with diluents. However, simulation showed the reaction, even weakened, persisted. On the contrary, pure dilution controlled flame length behavior. When XO2,i was decreased, length increased according to a unique evolution whatever the diluents. To measure flame length, several techniques were applied: OH Planar Laser Induced Fluorescence (Lf,OH), soot-Laser Induced Incandescence (Lf,LII), direct flame emission (Lf,luminous and Lf,peak). Length Lf,luminous was unable to correctly characterize flame lengthening. Lf,peak was the closest to the calculated stoichiometric length. So, the method giving Lf,peak appeared as the easiest and the most accurate one. Comparison between our data and correlations found in literature indicated Roper’s correlation was the most efficient to predict length evolution.</abstract><pub>Elsevier Inc</pub><doi>10.1016/j.proci.2010.06.100</doi><tpages>8</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1540-7489 |
ispartof | Proceedings of the Combustion Institute, 2011, Vol.33 (1), p.1071-1078 |
issn | 1540-7489 1873-2704 |
language | eng |
recordid | cdi_proquest_miscellaneous_864407857 |
source | Elsevier ScienceDirect Journals |
subjects | Carbon dioxide CH4/air CO2 dilution Combustion Correlation Diffusion flames Evolution Flame length Hoisting Laminar Laminar diffusion flame Liftoff Simulation |
title | Impact of CO2, N2 or Ar diluted in air on the length and lifting behavior of a laminar diffusion flame |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-19T11%3A30%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Impact%20of%20CO2,%20N2%20or%20Ar%20diluted%20in%20air%20on%20the%20length%20and%20lifting%20behavior%20of%20a%20laminar%20diffusion%20flame&rft.jtitle=Proceedings%20of%20the%20Combustion%20Institute&rft.au=Min,%20Jiesheng&rft.date=2011&rft.volume=33&rft.issue=1&rft.spage=1071&rft.epage=1078&rft.pages=1071-1078&rft.issn=1540-7489&rft.eissn=1873-2704&rft_id=info:doi/10.1016/j.proci.2010.06.100&rft_dat=%3Cproquest_cross%3E864407857%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=864407857&rft_id=info:pmid/&rft_els_id=S1540748910001732&rfr_iscdi=true |