Impact of CO2, N2 or Ar diluted in air on the length and lifting behavior of a laminar diffusion flame

Air-side dilution on laminar methane/air diffusion flames in the buoyant regime was extensively studied. CO2, important for EGR and fire safety, was chosen as a diluent. It was complemented by N2 and Ar. Flame stability, its external aspect and inner structure were quantified by complementary experi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Proceedings of the Combustion Institute 2011, Vol.33 (1), p.1071-1078
Hauptverfasser: Min, Jiesheng, Baillot, Françoise, Guo, Hongsheng, Domingues, Eric, Talbaut, Martine, Patte-Rouland, Béatrice
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1078
container_issue 1
container_start_page 1071
container_title Proceedings of the Combustion Institute
container_volume 33
creator Min, Jiesheng
Baillot, Françoise
Guo, Hongsheng
Domingues, Eric
Talbaut, Martine
Patte-Rouland, Béatrice
description Air-side dilution on laminar methane/air diffusion flames in the buoyant regime was extensively studied. CO2, important for EGR and fire safety, was chosen as a diluent. It was complemented by N2 and Ar. Flame stability, its external aspect and inner structure were quantified by complementary experiments and simulations. Two flame-response categories were highlighted, depending on whether mechanisms relied on several effects or mainly on pure dilution. In the former case, physico-chemical properties of diluents were essential. The greatest influence was detected with CO2, the least one with Ar. No critical value of the initial molar O2-concentration (XO2,i) was found to control quantities involved in stability (lifting limit, standoff distance of the attached flame), soot formation and flame-tip opening. It was found a critical flow-rate ratio from which flame-liftoff always occurred, crucial to describe lifting process induced by dilution. The reaction, naturally weak at the flame tip, led to an apparent open-tip with diluents. However, simulation showed the reaction, even weakened, persisted. On the contrary, pure dilution controlled flame length behavior. When XO2,i was decreased, length increased according to a unique evolution whatever the diluents. To measure flame length, several techniques were applied: OH Planar Laser Induced Fluorescence (Lf,OH), soot-Laser Induced Incandescence (Lf,LII), direct flame emission (Lf,luminous and Lf,peak). Length Lf,luminous was unable to correctly characterize flame lengthening. Lf,peak was the closest to the calculated stoichiometric length. So, the method giving Lf,peak appeared as the easiest and the most accurate one. Comparison between our data and correlations found in literature indicated Roper’s correlation was the most efficient to predict length evolution.
doi_str_mv 10.1016/j.proci.2010.06.100
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_864407857</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1540748910001732</els_id><sourcerecordid>864407857</sourcerecordid><originalsourceid>FETCH-LOGICAL-c250t-c7b1ee72f8800a280f0f917f2343282441ce310a1e2daf0ebd3b11993fc6073a3</originalsourceid><addsrcrecordid>eNp9kD1PwzAQhiMEEqXwC1i8sZBy_kicDgxVxZdU0QVmy3HOravEKXZSiX-PS5mZ7vTqfU66J8tuKcwo0PJhN9uH3rgZg5RAmUI4yya0kjxnEsR52gsBuRTV_DK7inEHwCXwYpLZt26vzUB6S5Zrdk_eGekDWQTSuHYcsCHOE-0C6T0Ztkha9JthS7RvSOvs4PyG1LjVB5egdEKTVnfO6yNu7RhdwmyK8Dq7sLqNePM3p9nn89PH8jVfrV_elotVblgBQ25kTREls1UFoFkFFuycSsu44KxiQlCDnIKmyBptAeuG15TO59yaEiTXfJrdne4mH18jxkF1LhpsW-2xH6OqSiFAVoVMTX5qmtDHGNCqfXCdDt-KgjpKVTv1K1UdpSooUwiJejxRmJ44OAwqGofeYOMCmkE1vfuX_wGOzn-X</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>864407857</pqid></control><display><type>article</type><title>Impact of CO2, N2 or Ar diluted in air on the length and lifting behavior of a laminar diffusion flame</title><source>Elsevier ScienceDirect Journals</source><creator>Min, Jiesheng ; Baillot, Françoise ; Guo, Hongsheng ; Domingues, Eric ; Talbaut, Martine ; Patte-Rouland, Béatrice</creator><creatorcontrib>Min, Jiesheng ; Baillot, Françoise ; Guo, Hongsheng ; Domingues, Eric ; Talbaut, Martine ; Patte-Rouland, Béatrice</creatorcontrib><description>Air-side dilution on laminar methane/air diffusion flames in the buoyant regime was extensively studied. CO2, important for EGR and fire safety, was chosen as a diluent. It was complemented by N2 and Ar. Flame stability, its external aspect and inner structure were quantified by complementary experiments and simulations. Two flame-response categories were highlighted, depending on whether mechanisms relied on several effects or mainly on pure dilution. In the former case, physico-chemical properties of diluents were essential. The greatest influence was detected with CO2, the least one with Ar. No critical value of the initial molar O2-concentration (XO2,i) was found to control quantities involved in stability (lifting limit, standoff distance of the attached flame), soot formation and flame-tip opening. It was found a critical flow-rate ratio from which flame-liftoff always occurred, crucial to describe lifting process induced by dilution. The reaction, naturally weak at the flame tip, led to an apparent open-tip with diluents. However, simulation showed the reaction, even weakened, persisted. On the contrary, pure dilution controlled flame length behavior. When XO2,i was decreased, length increased according to a unique evolution whatever the diluents. To measure flame length, several techniques were applied: OH Planar Laser Induced Fluorescence (Lf,OH), soot-Laser Induced Incandescence (Lf,LII), direct flame emission (Lf,luminous and Lf,peak). Length Lf,luminous was unable to correctly characterize flame lengthening. Lf,peak was the closest to the calculated stoichiometric length. So, the method giving Lf,peak appeared as the easiest and the most accurate one. Comparison between our data and correlations found in literature indicated Roper’s correlation was the most efficient to predict length evolution.</description><identifier>ISSN: 1540-7489</identifier><identifier>EISSN: 1873-2704</identifier><identifier>DOI: 10.1016/j.proci.2010.06.100</identifier><language>eng</language><publisher>Elsevier Inc</publisher><subject>Carbon dioxide ; CH4/air ; CO2 dilution ; Combustion ; Correlation ; Diffusion flames ; Evolution ; Flame length ; Hoisting ; Laminar ; Laminar diffusion flame ; Liftoff ; Simulation</subject><ispartof>Proceedings of the Combustion Institute, 2011, Vol.33 (1), p.1071-1078</ispartof><rights>2010 The Combustion Institute</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c250t-c7b1ee72f8800a280f0f917f2343282441ce310a1e2daf0ebd3b11993fc6073a3</citedby><cites>FETCH-LOGICAL-c250t-c7b1ee72f8800a280f0f917f2343282441ce310a1e2daf0ebd3b11993fc6073a3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S1540748910001732$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,4010,27900,27901,27902,65534</link.rule.ids></links><search><creatorcontrib>Min, Jiesheng</creatorcontrib><creatorcontrib>Baillot, Françoise</creatorcontrib><creatorcontrib>Guo, Hongsheng</creatorcontrib><creatorcontrib>Domingues, Eric</creatorcontrib><creatorcontrib>Talbaut, Martine</creatorcontrib><creatorcontrib>Patte-Rouland, Béatrice</creatorcontrib><title>Impact of CO2, N2 or Ar diluted in air on the length and lifting behavior of a laminar diffusion flame</title><title>Proceedings of the Combustion Institute</title><description>Air-side dilution on laminar methane/air diffusion flames in the buoyant regime was extensively studied. CO2, important for EGR and fire safety, was chosen as a diluent. It was complemented by N2 and Ar. Flame stability, its external aspect and inner structure were quantified by complementary experiments and simulations. Two flame-response categories were highlighted, depending on whether mechanisms relied on several effects or mainly on pure dilution. In the former case, physico-chemical properties of diluents were essential. The greatest influence was detected with CO2, the least one with Ar. No critical value of the initial molar O2-concentration (XO2,i) was found to control quantities involved in stability (lifting limit, standoff distance of the attached flame), soot formation and flame-tip opening. It was found a critical flow-rate ratio from which flame-liftoff always occurred, crucial to describe lifting process induced by dilution. The reaction, naturally weak at the flame tip, led to an apparent open-tip with diluents. However, simulation showed the reaction, even weakened, persisted. On the contrary, pure dilution controlled flame length behavior. When XO2,i was decreased, length increased according to a unique evolution whatever the diluents. To measure flame length, several techniques were applied: OH Planar Laser Induced Fluorescence (Lf,OH), soot-Laser Induced Incandescence (Lf,LII), direct flame emission (Lf,luminous and Lf,peak). Length Lf,luminous was unable to correctly characterize flame lengthening. Lf,peak was the closest to the calculated stoichiometric length. So, the method giving Lf,peak appeared as the easiest and the most accurate one. Comparison between our data and correlations found in literature indicated Roper’s correlation was the most efficient to predict length evolution.</description><subject>Carbon dioxide</subject><subject>CH4/air</subject><subject>CO2 dilution</subject><subject>Combustion</subject><subject>Correlation</subject><subject>Diffusion flames</subject><subject>Evolution</subject><subject>Flame length</subject><subject>Hoisting</subject><subject>Laminar</subject><subject>Laminar diffusion flame</subject><subject>Liftoff</subject><subject>Simulation</subject><issn>1540-7489</issn><issn>1873-2704</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNp9kD1PwzAQhiMEEqXwC1i8sZBy_kicDgxVxZdU0QVmy3HOravEKXZSiX-PS5mZ7vTqfU66J8tuKcwo0PJhN9uH3rgZg5RAmUI4yya0kjxnEsR52gsBuRTV_DK7inEHwCXwYpLZt26vzUB6S5Zrdk_eGekDWQTSuHYcsCHOE-0C6T0Ztkha9JthS7RvSOvs4PyG1LjVB5egdEKTVnfO6yNu7RhdwmyK8Dq7sLqNePM3p9nn89PH8jVfrV_elotVblgBQ25kTREls1UFoFkFFuycSsu44KxiQlCDnIKmyBptAeuG15TO59yaEiTXfJrdne4mH18jxkF1LhpsW-2xH6OqSiFAVoVMTX5qmtDHGNCqfXCdDt-KgjpKVTv1K1UdpSooUwiJejxRmJ44OAwqGofeYOMCmkE1vfuX_wGOzn-X</recordid><startdate>2011</startdate><enddate>2011</enddate><creator>Min, Jiesheng</creator><creator>Baillot, Françoise</creator><creator>Guo, Hongsheng</creator><creator>Domingues, Eric</creator><creator>Talbaut, Martine</creator><creator>Patte-Rouland, Béatrice</creator><general>Elsevier Inc</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope></search><sort><creationdate>2011</creationdate><title>Impact of CO2, N2 or Ar diluted in air on the length and lifting behavior of a laminar diffusion flame</title><author>Min, Jiesheng ; Baillot, Françoise ; Guo, Hongsheng ; Domingues, Eric ; Talbaut, Martine ; Patte-Rouland, Béatrice</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c250t-c7b1ee72f8800a280f0f917f2343282441ce310a1e2daf0ebd3b11993fc6073a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Carbon dioxide</topic><topic>CH4/air</topic><topic>CO2 dilution</topic><topic>Combustion</topic><topic>Correlation</topic><topic>Diffusion flames</topic><topic>Evolution</topic><topic>Flame length</topic><topic>Hoisting</topic><topic>Laminar</topic><topic>Laminar diffusion flame</topic><topic>Liftoff</topic><topic>Simulation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Min, Jiesheng</creatorcontrib><creatorcontrib>Baillot, Françoise</creatorcontrib><creatorcontrib>Guo, Hongsheng</creatorcontrib><creatorcontrib>Domingues, Eric</creatorcontrib><creatorcontrib>Talbaut, Martine</creatorcontrib><creatorcontrib>Patte-Rouland, Béatrice</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Proceedings of the Combustion Institute</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Min, Jiesheng</au><au>Baillot, Françoise</au><au>Guo, Hongsheng</au><au>Domingues, Eric</au><au>Talbaut, Martine</au><au>Patte-Rouland, Béatrice</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Impact of CO2, N2 or Ar diluted in air on the length and lifting behavior of a laminar diffusion flame</atitle><jtitle>Proceedings of the Combustion Institute</jtitle><date>2011</date><risdate>2011</risdate><volume>33</volume><issue>1</issue><spage>1071</spage><epage>1078</epage><pages>1071-1078</pages><issn>1540-7489</issn><eissn>1873-2704</eissn><abstract>Air-side dilution on laminar methane/air diffusion flames in the buoyant regime was extensively studied. CO2, important for EGR and fire safety, was chosen as a diluent. It was complemented by N2 and Ar. Flame stability, its external aspect and inner structure were quantified by complementary experiments and simulations. Two flame-response categories were highlighted, depending on whether mechanisms relied on several effects or mainly on pure dilution. In the former case, physico-chemical properties of diluents were essential. The greatest influence was detected with CO2, the least one with Ar. No critical value of the initial molar O2-concentration (XO2,i) was found to control quantities involved in stability (lifting limit, standoff distance of the attached flame), soot formation and flame-tip opening. It was found a critical flow-rate ratio from which flame-liftoff always occurred, crucial to describe lifting process induced by dilution. The reaction, naturally weak at the flame tip, led to an apparent open-tip with diluents. However, simulation showed the reaction, even weakened, persisted. On the contrary, pure dilution controlled flame length behavior. When XO2,i was decreased, length increased according to a unique evolution whatever the diluents. To measure flame length, several techniques were applied: OH Planar Laser Induced Fluorescence (Lf,OH), soot-Laser Induced Incandescence (Lf,LII), direct flame emission (Lf,luminous and Lf,peak). Length Lf,luminous was unable to correctly characterize flame lengthening. Lf,peak was the closest to the calculated stoichiometric length. So, the method giving Lf,peak appeared as the easiest and the most accurate one. Comparison between our data and correlations found in literature indicated Roper’s correlation was the most efficient to predict length evolution.</abstract><pub>Elsevier Inc</pub><doi>10.1016/j.proci.2010.06.100</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1540-7489
ispartof Proceedings of the Combustion Institute, 2011, Vol.33 (1), p.1071-1078
issn 1540-7489
1873-2704
language eng
recordid cdi_proquest_miscellaneous_864407857
source Elsevier ScienceDirect Journals
subjects Carbon dioxide
CH4/air
CO2 dilution
Combustion
Correlation
Diffusion flames
Evolution
Flame length
Hoisting
Laminar
Laminar diffusion flame
Liftoff
Simulation
title Impact of CO2, N2 or Ar diluted in air on the length and lifting behavior of a laminar diffusion flame
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-19T11%3A30%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Impact%20of%20CO2,%20N2%20or%20Ar%20diluted%20in%20air%20on%20the%20length%20and%20lifting%20behavior%20of%20a%20laminar%20diffusion%20flame&rft.jtitle=Proceedings%20of%20the%20Combustion%20Institute&rft.au=Min,%20Jiesheng&rft.date=2011&rft.volume=33&rft.issue=1&rft.spage=1071&rft.epage=1078&rft.pages=1071-1078&rft.issn=1540-7489&rft.eissn=1873-2704&rft_id=info:doi/10.1016/j.proci.2010.06.100&rft_dat=%3Cproquest_cross%3E864407857%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=864407857&rft_id=info:pmid/&rft_els_id=S1540748910001732&rfr_iscdi=true