A new HPLC method for the simultaneous determination of ascorbic acid and aminothiols in human plasma and erythrocytes using electrochemical detection
A new, simple, economical and validated high-performance liquid chromatography linked with electrochemical detector (HPLC–ECD) method has been developed and optimized for different experimental parameters to analyze the most common monothiols and disulfide (cystine, cysteine, homocysteine, methionin...
Gespeichert in:
Veröffentlicht in: | Talanta (Oxford) 2011-05, Vol.84 (3), p.789-801 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 801 |
---|---|
container_issue | 3 |
container_start_page | 789 |
container_title | Talanta (Oxford) |
container_volume | 84 |
creator | Khan, Abad Khan, Muhammad I. Iqbal, Zafar Shah, Yasar Ahmad, Lateef Nazir, Shabnam Watson, David G. Khan, Jamshaid Ali Nasir, Fazli Khan, Abbas Ismail |
description | A new, simple, economical and validated high-performance liquid chromatography linked with electrochemical detector (HPLC–ECD) method has been developed and optimized for different experimental parameters to analyze the most common monothiols and disulfide (cystine, cysteine, homocysteine, methionine, reduced (GSH) and oxidized glutathione (GSSG)) and ascorbic acid present in human plasma and erythrocytes using dopamine as internal standard (IS). Complete separation of all the targets analytes and IS at 35
°C on Discovery HS C18 RP column (250
mm
×
4.6
mm, 5
μm) was achieved using 0.05% TFA:methanol (97:3, v/v) as a mobile phase pumped at the rate of 0.6
ml
min
−1 using electrochemical detector in DC mode at the detector potential of 900
mV. The limits of detection (3 S/N) and limits of quantification (10 S/N) of the studied compounds were evaluated using dilution method. The proposed method was validated according to standard guidelines and optimization of various experimental parameters and chromatographic conditions was carried out. The optimized and validated HPLC–ECD method was successfully applied for the determination of the abovementioned compounds in human plasma and erythrocytes. The method will be quite suitable for the determination of plasma and erythrocyte profile of ascorbic acid and aminothiols in oxidative stress and other basic research studies. |
doi_str_mv | 10.1016/j.talanta.2011.02.019 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_861793965</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0039914011001500</els_id><sourcerecordid>861793965</sourcerecordid><originalsourceid>FETCH-LOGICAL-c460t-7680ac8cfa5ade5a29f2e3293c15a4b47c03d9adc3972fee3cd17277aba642e23</originalsourceid><addsrcrecordid>eNqFkcuOEzEQRS0EYjIDnwDyBrHq4Ec_V2gUwQxSJFjA2qrY1bQjtx1s96D8CN-LMwmwZGFZcp3yrbqXkFecrTnj7bv9OoMDn2EtGOdrJtaMD0_IivedrGTTyadkxZgcqoHX7Ipcp7RnjAnJ5HNyJXjdC9HXK_Lrlnr8Se-_bDd0xjwFQ8cQaZ6QJjsvLoPHsCRqMGOcrYdsg6dhpJB0iDurKWhrKPhySjnkyQaXqPV0Wmbw9OAgzfBYx3jMUwz6mDHRJVn_naJDncvThLPV4B5V9EnhBXk2gkv48nLfkG8fP3zd3Ffbz3efNrfbStcty1XX9gx0r0dowGADYhgFSjFIzRuod3WnmTQDGC2HToyIUhveia6DHbS1QCFvyNvzv4cYfiyYsppt0ujceW3Vt7wb5NA2hWzOpI4hpYijOkQ7QzwqztQpEbVXl0TUKRHFhCqJlL7XF4VlN6P52_UnggK8uQDFUnBjBK9t-sfVnPW8Pw3w_sxh8ePBYlRJW_QajY3FNGWC_c8ovwHHqbAY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>861793965</pqid></control><display><type>article</type><title>A new HPLC method for the simultaneous determination of ascorbic acid and aminothiols in human plasma and erythrocytes using electrochemical detection</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Khan, Abad ; Khan, Muhammad I. ; Iqbal, Zafar ; Shah, Yasar ; Ahmad, Lateef ; Nazir, Shabnam ; Watson, David G. ; Khan, Jamshaid Ali ; Nasir, Fazli ; Khan, Abbas ; Ismail</creator><creatorcontrib>Khan, Abad ; Khan, Muhammad I. ; Iqbal, Zafar ; Shah, Yasar ; Ahmad, Lateef ; Nazir, Shabnam ; Watson, David G. ; Khan, Jamshaid Ali ; Nasir, Fazli ; Khan, Abbas ; Ismail</creatorcontrib><description>A new, simple, economical and validated high-performance liquid chromatography linked with electrochemical detector (HPLC–ECD) method has been developed and optimized for different experimental parameters to analyze the most common monothiols and disulfide (cystine, cysteine, homocysteine, methionine, reduced (GSH) and oxidized glutathione (GSSG)) and ascorbic acid present in human plasma and erythrocytes using dopamine as internal standard (IS). Complete separation of all the targets analytes and IS at 35
°C on Discovery HS C18 RP column (250
mm
×
4.6
mm, 5
μm) was achieved using 0.05% TFA:methanol (97:3, v/v) as a mobile phase pumped at the rate of 0.6
ml
min
−1 using electrochemical detector in DC mode at the detector potential of 900
mV. The limits of detection (3 S/N) and limits of quantification (10 S/N) of the studied compounds were evaluated using dilution method. The proposed method was validated according to standard guidelines and optimization of various experimental parameters and chromatographic conditions was carried out. The optimized and validated HPLC–ECD method was successfully applied for the determination of the abovementioned compounds in human plasma and erythrocytes. The method will be quite suitable for the determination of plasma and erythrocyte profile of ascorbic acid and aminothiols in oxidative stress and other basic research studies.</description><identifier>ISSN: 0039-9140</identifier><identifier>EISSN: 1873-3573</identifier><identifier>DOI: 10.1016/j.talanta.2011.02.019</identifier><identifier>PMID: 21482284</identifier><identifier>CODEN: TLNTA2</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Analytical chemistry ; Ascorbic acid ; Ascorbic Acid - blood ; Chemistry ; Chromatographic methods and physical methods associated with chromatography ; Chromatography, High Pressure Liquid - methods ; Electrochemical detection ; Electrochemical methods ; Electrochemistry - methods ; Erythrocytes ; Erythrocytes - metabolism ; Exact sciences and technology ; General, instrumentation ; Humans ; Monothiols ; Other chromatographic methods ; Plasma ; Reference Standards ; Sulfhydryl Compounds - blood ; Validated</subject><ispartof>Talanta (Oxford), 2011-05, Vol.84 (3), p.789-801</ispartof><rights>2011 Elsevier B.V.</rights><rights>2015 INIST-CNRS</rights><rights>Copyright © 2011 Elsevier B.V. All rights reserved.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c460t-7680ac8cfa5ade5a29f2e3293c15a4b47c03d9adc3972fee3cd17277aba642e23</citedby><cites>FETCH-LOGICAL-c460t-7680ac8cfa5ade5a29f2e3293c15a4b47c03d9adc3972fee3cd17277aba642e23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S0039914011001500$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,27901,27902,65306</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=24108185$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21482284$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Khan, Abad</creatorcontrib><creatorcontrib>Khan, Muhammad I.</creatorcontrib><creatorcontrib>Iqbal, Zafar</creatorcontrib><creatorcontrib>Shah, Yasar</creatorcontrib><creatorcontrib>Ahmad, Lateef</creatorcontrib><creatorcontrib>Nazir, Shabnam</creatorcontrib><creatorcontrib>Watson, David G.</creatorcontrib><creatorcontrib>Khan, Jamshaid Ali</creatorcontrib><creatorcontrib>Nasir, Fazli</creatorcontrib><creatorcontrib>Khan, Abbas</creatorcontrib><creatorcontrib>Ismail</creatorcontrib><title>A new HPLC method for the simultaneous determination of ascorbic acid and aminothiols in human plasma and erythrocytes using electrochemical detection</title><title>Talanta (Oxford)</title><addtitle>Talanta</addtitle><description>A new, simple, economical and validated high-performance liquid chromatography linked with electrochemical detector (HPLC–ECD) method has been developed and optimized for different experimental parameters to analyze the most common monothiols and disulfide (cystine, cysteine, homocysteine, methionine, reduced (GSH) and oxidized glutathione (GSSG)) and ascorbic acid present in human plasma and erythrocytes using dopamine as internal standard (IS). Complete separation of all the targets analytes and IS at 35
°C on Discovery HS C18 RP column (250
mm
×
4.6
mm, 5
μm) was achieved using 0.05% TFA:methanol (97:3, v/v) as a mobile phase pumped at the rate of 0.6
ml
min
−1 using electrochemical detector in DC mode at the detector potential of 900
mV. The limits of detection (3 S/N) and limits of quantification (10 S/N) of the studied compounds were evaluated using dilution method. The proposed method was validated according to standard guidelines and optimization of various experimental parameters and chromatographic conditions was carried out. The optimized and validated HPLC–ECD method was successfully applied for the determination of the abovementioned compounds in human plasma and erythrocytes. The method will be quite suitable for the determination of plasma and erythrocyte profile of ascorbic acid and aminothiols in oxidative stress and other basic research studies.</description><subject>Analytical chemistry</subject><subject>Ascorbic acid</subject><subject>Ascorbic Acid - blood</subject><subject>Chemistry</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Chromatography, High Pressure Liquid - methods</subject><subject>Electrochemical detection</subject><subject>Electrochemical methods</subject><subject>Electrochemistry - methods</subject><subject>Erythrocytes</subject><subject>Erythrocytes - metabolism</subject><subject>Exact sciences and technology</subject><subject>General, instrumentation</subject><subject>Humans</subject><subject>Monothiols</subject><subject>Other chromatographic methods</subject><subject>Plasma</subject><subject>Reference Standards</subject><subject>Sulfhydryl Compounds - blood</subject><subject>Validated</subject><issn>0039-9140</issn><issn>1873-3573</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkcuOEzEQRS0EYjIDnwDyBrHq4Ec_V2gUwQxSJFjA2qrY1bQjtx1s96D8CN-LMwmwZGFZcp3yrbqXkFecrTnj7bv9OoMDn2EtGOdrJtaMD0_IivedrGTTyadkxZgcqoHX7Ipcp7RnjAnJ5HNyJXjdC9HXK_Lrlnr8Se-_bDd0xjwFQ8cQaZ6QJjsvLoPHsCRqMGOcrYdsg6dhpJB0iDurKWhrKPhySjnkyQaXqPV0Wmbw9OAgzfBYx3jMUwz6mDHRJVn_naJDncvThLPV4B5V9EnhBXk2gkv48nLfkG8fP3zd3Ffbz3efNrfbStcty1XX9gx0r0dowGADYhgFSjFIzRuod3WnmTQDGC2HToyIUhveia6DHbS1QCFvyNvzv4cYfiyYsppt0ujceW3Vt7wb5NA2hWzOpI4hpYijOkQ7QzwqztQpEbVXl0TUKRHFhCqJlL7XF4VlN6P52_UnggK8uQDFUnBjBK9t-sfVnPW8Pw3w_sxh8ePBYlRJW_QajY3FNGWC_c8ovwHHqbAY</recordid><startdate>20110515</startdate><enddate>20110515</enddate><creator>Khan, Abad</creator><creator>Khan, Muhammad I.</creator><creator>Iqbal, Zafar</creator><creator>Shah, Yasar</creator><creator>Ahmad, Lateef</creator><creator>Nazir, Shabnam</creator><creator>Watson, David G.</creator><creator>Khan, Jamshaid Ali</creator><creator>Nasir, Fazli</creator><creator>Khan, Abbas</creator><creator>Ismail</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20110515</creationdate><title>A new HPLC method for the simultaneous determination of ascorbic acid and aminothiols in human plasma and erythrocytes using electrochemical detection</title><author>Khan, Abad ; Khan, Muhammad I. ; Iqbal, Zafar ; Shah, Yasar ; Ahmad, Lateef ; Nazir, Shabnam ; Watson, David G. ; Khan, Jamshaid Ali ; Nasir, Fazli ; Khan, Abbas ; Ismail</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c460t-7680ac8cfa5ade5a29f2e3293c15a4b47c03d9adc3972fee3cd17277aba642e23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Analytical chemistry</topic><topic>Ascorbic acid</topic><topic>Ascorbic Acid - blood</topic><topic>Chemistry</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Chromatography, High Pressure Liquid - methods</topic><topic>Electrochemical detection</topic><topic>Electrochemical methods</topic><topic>Electrochemistry - methods</topic><topic>Erythrocytes</topic><topic>Erythrocytes - metabolism</topic><topic>Exact sciences and technology</topic><topic>General, instrumentation</topic><topic>Humans</topic><topic>Monothiols</topic><topic>Other chromatographic methods</topic><topic>Plasma</topic><topic>Reference Standards</topic><topic>Sulfhydryl Compounds - blood</topic><topic>Validated</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Khan, Abad</creatorcontrib><creatorcontrib>Khan, Muhammad I.</creatorcontrib><creatorcontrib>Iqbal, Zafar</creatorcontrib><creatorcontrib>Shah, Yasar</creatorcontrib><creatorcontrib>Ahmad, Lateef</creatorcontrib><creatorcontrib>Nazir, Shabnam</creatorcontrib><creatorcontrib>Watson, David G.</creatorcontrib><creatorcontrib>Khan, Jamshaid Ali</creatorcontrib><creatorcontrib>Nasir, Fazli</creatorcontrib><creatorcontrib>Khan, Abbas</creatorcontrib><creatorcontrib>Ismail</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Talanta (Oxford)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Khan, Abad</au><au>Khan, Muhammad I.</au><au>Iqbal, Zafar</au><au>Shah, Yasar</au><au>Ahmad, Lateef</au><au>Nazir, Shabnam</au><au>Watson, David G.</au><au>Khan, Jamshaid Ali</au><au>Nasir, Fazli</au><au>Khan, Abbas</au><au>Ismail</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A new HPLC method for the simultaneous determination of ascorbic acid and aminothiols in human plasma and erythrocytes using electrochemical detection</atitle><jtitle>Talanta (Oxford)</jtitle><addtitle>Talanta</addtitle><date>2011-05-15</date><risdate>2011</risdate><volume>84</volume><issue>3</issue><spage>789</spage><epage>801</epage><pages>789-801</pages><issn>0039-9140</issn><eissn>1873-3573</eissn><coden>TLNTA2</coden><abstract>A new, simple, economical and validated high-performance liquid chromatography linked with electrochemical detector (HPLC–ECD) method has been developed and optimized for different experimental parameters to analyze the most common monothiols and disulfide (cystine, cysteine, homocysteine, methionine, reduced (GSH) and oxidized glutathione (GSSG)) and ascorbic acid present in human plasma and erythrocytes using dopamine as internal standard (IS). Complete separation of all the targets analytes and IS at 35
°C on Discovery HS C18 RP column (250
mm
×
4.6
mm, 5
μm) was achieved using 0.05% TFA:methanol (97:3, v/v) as a mobile phase pumped at the rate of 0.6
ml
min
−1 using electrochemical detector in DC mode at the detector potential of 900
mV. The limits of detection (3 S/N) and limits of quantification (10 S/N) of the studied compounds were evaluated using dilution method. The proposed method was validated according to standard guidelines and optimization of various experimental parameters and chromatographic conditions was carried out. The optimized and validated HPLC–ECD method was successfully applied for the determination of the abovementioned compounds in human plasma and erythrocytes. The method will be quite suitable for the determination of plasma and erythrocyte profile of ascorbic acid and aminothiols in oxidative stress and other basic research studies.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><pmid>21482284</pmid><doi>10.1016/j.talanta.2011.02.019</doi><tpages>13</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0039-9140 |
ispartof | Talanta (Oxford), 2011-05, Vol.84 (3), p.789-801 |
issn | 0039-9140 1873-3573 |
language | eng |
recordid | cdi_proquest_miscellaneous_861793965 |
source | MEDLINE; Elsevier ScienceDirect Journals |
subjects | Analytical chemistry Ascorbic acid Ascorbic Acid - blood Chemistry Chromatographic methods and physical methods associated with chromatography Chromatography, High Pressure Liquid - methods Electrochemical detection Electrochemical methods Electrochemistry - methods Erythrocytes Erythrocytes - metabolism Exact sciences and technology General, instrumentation Humans Monothiols Other chromatographic methods Plasma Reference Standards Sulfhydryl Compounds - blood Validated |
title | A new HPLC method for the simultaneous determination of ascorbic acid and aminothiols in human plasma and erythrocytes using electrochemical detection |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-06T08%3A59%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20new%20HPLC%20method%20for%20the%20simultaneous%20determination%20of%20ascorbic%20acid%20and%20aminothiols%20in%20human%20plasma%20and%20erythrocytes%20using%20electrochemical%20detection&rft.jtitle=Talanta%20(Oxford)&rft.au=Khan,%20Abad&rft.date=2011-05-15&rft.volume=84&rft.issue=3&rft.spage=789&rft.epage=801&rft.pages=789-801&rft.issn=0039-9140&rft.eissn=1873-3573&rft.coden=TLNTA2&rft_id=info:doi/10.1016/j.talanta.2011.02.019&rft_dat=%3Cproquest_cross%3E861793965%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=861793965&rft_id=info:pmid/21482284&rft_els_id=S0039914011001500&rfr_iscdi=true |