Modal parameter identification of a containment using ambient vibration measurements

Ensuring and maintaining the structural integrity of the containment structure in nuclear power plants is essential for preserving the nuclear reactor and other safety-related systems as well as protecting plant workers and publics from hazardous radioactive materials. To date, the structural integr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear engineering and design 2010-03, Vol.240 (3), p.453-460
Hauptverfasser: Choi, Sanghyun, Park, Sooyong, Hyun, Chang-Hun, Kim, Moon-Soo, Choi, Kang-Ryong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 460
container_issue 3
container_start_page 453
container_title Nuclear engineering and design
container_volume 240
creator Choi, Sanghyun
Park, Sooyong
Hyun, Chang-Hun
Kim, Moon-Soo
Choi, Kang-Ryong
description Ensuring and maintaining the structural integrity of the containment structure in nuclear power plants is essential for preserving the nuclear reactor and other safety-related systems as well as protecting plant workers and publics from hazardous radioactive materials. To date, the structural integrity of the containment has been evaluated periodically via various nondestructive inspection methods. However, these methods require considerable time and cost to estimate overall structural integrity. In this paper, the possibility of monitoring the structural integrity of the containment utilizing ambient vibration measurement is explored. The ambient vibration testing was selected because it can avoid the interruption of normal operation of power plants. To fulfill the objective, the ambient vibration of the containment of Ulchin Nuclear Power Plant Unit 5 in Korea was measured, and the modal parameters, i.e., resonant frequencies and corresponding mode shapes, were extracted using the modal identification techniques in the frequency domain, i.e., the peak picking and the frequency domain decomposition methods. Using the extracted modal parameters and the finite element model, the elastic modulus of the concrete was estimated based on the sensitivity-based system identification method.
doi_str_mv 10.1016/j.nucengdes.2009.11.037
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_861570364</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0029549309006281</els_id><sourcerecordid>861570364</sourcerecordid><originalsourceid>FETCH-LOGICAL-c377t-ea8cb605a3a9237427db6d08107ffa1c20f4d9a24c4f3b74ef14f838e273b1eb3</originalsourceid><addsrcrecordid>eNqFkEtrwzAMgM3YYF2337Bcxk7J_Ejj-FjKXtCxSwe7GcWRi0vidHZS2L9fQkuv00UIfZLQR8g9oxmjrHjaZX4w6Lc1xoxTqjLGMirkBZmxUvJULtT3JZlRylW6yJW4Jjcx7ugUis_I5qOroUn2EKDFHkPiavS9s85A7zqfdDaBxHS-B-fbsZMM0fltAm3lpurgqnAEW4Q4BJyYeEuuLDQR7055Tr5enjert3T9-fq-Wq5TI6TsU4TSVAVdgADFhcy5rKuipiWj0lpghlOb1wp4bnIrKpmjZbktRYlciophJebk8bh3H7qfAWOvWxcNNg147Iaoy4ItJBVFPpLySJrQxRjQ6n1wLYRfzaieNOqdPmvUk0bNmB41jpMPpxsQDTQ2gDcunsc5V0yVtBi55ZHD8eGDw6CjGRUZrF1A0-u6c__e-gN91Y7k</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>861570364</pqid></control><display><type>article</type><title>Modal parameter identification of a containment using ambient vibration measurements</title><source>Access via ScienceDirect (Elsevier)</source><creator>Choi, Sanghyun ; Park, Sooyong ; Hyun, Chang-Hun ; Kim, Moon-Soo ; Choi, Kang-Ryong</creator><creatorcontrib>Choi, Sanghyun ; Park, Sooyong ; Hyun, Chang-Hun ; Kim, Moon-Soo ; Choi, Kang-Ryong</creatorcontrib><description>Ensuring and maintaining the structural integrity of the containment structure in nuclear power plants is essential for preserving the nuclear reactor and other safety-related systems as well as protecting plant workers and publics from hazardous radioactive materials. To date, the structural integrity of the containment has been evaluated periodically via various nondestructive inspection methods. However, these methods require considerable time and cost to estimate overall structural integrity. In this paper, the possibility of monitoring the structural integrity of the containment utilizing ambient vibration measurement is explored. The ambient vibration testing was selected because it can avoid the interruption of normal operation of power plants. To fulfill the objective, the ambient vibration of the containment of Ulchin Nuclear Power Plant Unit 5 in Korea was measured, and the modal parameters, i.e., resonant frequencies and corresponding mode shapes, were extracted using the modal identification techniques in the frequency domain, i.e., the peak picking and the frequency domain decomposition methods. Using the extracted modal parameters and the finite element model, the elastic modulus of the concrete was estimated based on the sensitivity-based system identification method.</description><identifier>ISSN: 0029-5493</identifier><identifier>EISSN: 1872-759X</identifier><identifier>DOI: 10.1016/j.nucengdes.2009.11.037</identifier><identifier>CODEN: NEDEAU</identifier><language>eng</language><publisher>Amsterdam: Elsevier B.V</publisher><subject>Applied sciences ; Energy ; Energy. Thermal use of fuels ; Exact sciences and technology ; Fission nuclear power plants ; Installations for energy generation and conversion: thermal and electrical energy</subject><ispartof>Nuclear engineering and design, 2010-03, Vol.240 (3), p.453-460</ispartof><rights>2009 Elsevier B.V.</rights><rights>2015 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c377t-ea8cb605a3a9237427db6d08107ffa1c20f4d9a24c4f3b74ef14f838e273b1eb3</citedby><cites>FETCH-LOGICAL-c377t-ea8cb605a3a9237427db6d08107ffa1c20f4d9a24c4f3b74ef14f838e273b1eb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://dx.doi.org/10.1016/j.nucengdes.2009.11.037$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>315,781,785,3551,27929,27930,46000</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=22919806$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Choi, Sanghyun</creatorcontrib><creatorcontrib>Park, Sooyong</creatorcontrib><creatorcontrib>Hyun, Chang-Hun</creatorcontrib><creatorcontrib>Kim, Moon-Soo</creatorcontrib><creatorcontrib>Choi, Kang-Ryong</creatorcontrib><title>Modal parameter identification of a containment using ambient vibration measurements</title><title>Nuclear engineering and design</title><description>Ensuring and maintaining the structural integrity of the containment structure in nuclear power plants is essential for preserving the nuclear reactor and other safety-related systems as well as protecting plant workers and publics from hazardous radioactive materials. To date, the structural integrity of the containment has been evaluated periodically via various nondestructive inspection methods. However, these methods require considerable time and cost to estimate overall structural integrity. In this paper, the possibility of monitoring the structural integrity of the containment utilizing ambient vibration measurement is explored. The ambient vibration testing was selected because it can avoid the interruption of normal operation of power plants. To fulfill the objective, the ambient vibration of the containment of Ulchin Nuclear Power Plant Unit 5 in Korea was measured, and the modal parameters, i.e., resonant frequencies and corresponding mode shapes, were extracted using the modal identification techniques in the frequency domain, i.e., the peak picking and the frequency domain decomposition methods. Using the extracted modal parameters and the finite element model, the elastic modulus of the concrete was estimated based on the sensitivity-based system identification method.</description><subject>Applied sciences</subject><subject>Energy</subject><subject>Energy. Thermal use of fuels</subject><subject>Exact sciences and technology</subject><subject>Fission nuclear power plants</subject><subject>Installations for energy generation and conversion: thermal and electrical energy</subject><issn>0029-5493</issn><issn>1872-759X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNqFkEtrwzAMgM3YYF2337Bcxk7J_Ejj-FjKXtCxSwe7GcWRi0vidHZS2L9fQkuv00UIfZLQR8g9oxmjrHjaZX4w6Lc1xoxTqjLGMirkBZmxUvJULtT3JZlRylW6yJW4Jjcx7ugUis_I5qOroUn2EKDFHkPiavS9s85A7zqfdDaBxHS-B-fbsZMM0fltAm3lpurgqnAEW4Q4BJyYeEuuLDQR7055Tr5enjert3T9-fq-Wq5TI6TsU4TSVAVdgADFhcy5rKuipiWj0lpghlOb1wp4bnIrKpmjZbktRYlciophJebk8bh3H7qfAWOvWxcNNg147Iaoy4ItJBVFPpLySJrQxRjQ6n1wLYRfzaieNOqdPmvUk0bNmB41jpMPpxsQDTQ2gDcunsc5V0yVtBi55ZHD8eGDw6CjGRUZrF1A0-u6c__e-gN91Y7k</recordid><startdate>20100301</startdate><enddate>20100301</enddate><creator>Choi, Sanghyun</creator><creator>Park, Sooyong</creator><creator>Hyun, Chang-Hun</creator><creator>Kim, Moon-Soo</creator><creator>Choi, Kang-Ryong</creator><general>Elsevier B.V</general><general>Elsevier</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>7SU</scope><scope>7TB</scope><scope>8FD</scope><scope>C1K</scope><scope>FR3</scope><scope>KR7</scope><scope>L7M</scope></search><sort><creationdate>20100301</creationdate><title>Modal parameter identification of a containment using ambient vibration measurements</title><author>Choi, Sanghyun ; Park, Sooyong ; Hyun, Chang-Hun ; Kim, Moon-Soo ; Choi, Kang-Ryong</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c377t-ea8cb605a3a9237427db6d08107ffa1c20f4d9a24c4f3b74ef14f838e273b1eb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Applied sciences</topic><topic>Energy</topic><topic>Energy. Thermal use of fuels</topic><topic>Exact sciences and technology</topic><topic>Fission nuclear power plants</topic><topic>Installations for energy generation and conversion: thermal and electrical energy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Choi, Sanghyun</creatorcontrib><creatorcontrib>Park, Sooyong</creatorcontrib><creatorcontrib>Hyun, Chang-Hun</creatorcontrib><creatorcontrib>Kim, Moon-Soo</creatorcontrib><creatorcontrib>Choi, Kang-Ryong</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Environmental Engineering Abstracts</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Environmental Sciences and Pollution Management</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Nuclear engineering and design</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Choi, Sanghyun</au><au>Park, Sooyong</au><au>Hyun, Chang-Hun</au><au>Kim, Moon-Soo</au><au>Choi, Kang-Ryong</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Modal parameter identification of a containment using ambient vibration measurements</atitle><jtitle>Nuclear engineering and design</jtitle><date>2010-03-01</date><risdate>2010</risdate><volume>240</volume><issue>3</issue><spage>453</spage><epage>460</epage><pages>453-460</pages><issn>0029-5493</issn><eissn>1872-759X</eissn><coden>NEDEAU</coden><abstract>Ensuring and maintaining the structural integrity of the containment structure in nuclear power plants is essential for preserving the nuclear reactor and other safety-related systems as well as protecting plant workers and publics from hazardous radioactive materials. To date, the structural integrity of the containment has been evaluated periodically via various nondestructive inspection methods. However, these methods require considerable time and cost to estimate overall structural integrity. In this paper, the possibility of monitoring the structural integrity of the containment utilizing ambient vibration measurement is explored. The ambient vibration testing was selected because it can avoid the interruption of normal operation of power plants. To fulfill the objective, the ambient vibration of the containment of Ulchin Nuclear Power Plant Unit 5 in Korea was measured, and the modal parameters, i.e., resonant frequencies and corresponding mode shapes, were extracted using the modal identification techniques in the frequency domain, i.e., the peak picking and the frequency domain decomposition methods. Using the extracted modal parameters and the finite element model, the elastic modulus of the concrete was estimated based on the sensitivity-based system identification method.</abstract><cop>Amsterdam</cop><pub>Elsevier B.V</pub><doi>10.1016/j.nucengdes.2009.11.037</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0029-5493
ispartof Nuclear engineering and design, 2010-03, Vol.240 (3), p.453-460
issn 0029-5493
1872-759X
language eng
recordid cdi_proquest_miscellaneous_861570364
source Access via ScienceDirect (Elsevier)
subjects Applied sciences
Energy
Energy. Thermal use of fuels
Exact sciences and technology
Fission nuclear power plants
Installations for energy generation and conversion: thermal and electrical energy
title Modal parameter identification of a containment using ambient vibration measurements
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-11T19%3A35%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Modal%20parameter%20identification%20of%20a%20containment%20using%20ambient%20vibration%20measurements&rft.jtitle=Nuclear%20engineering%20and%20design&rft.au=Choi,%20Sanghyun&rft.date=2010-03-01&rft.volume=240&rft.issue=3&rft.spage=453&rft.epage=460&rft.pages=453-460&rft.issn=0029-5493&rft.eissn=1872-759X&rft.coden=NEDEAU&rft_id=info:doi/10.1016/j.nucengdes.2009.11.037&rft_dat=%3Cproquest_cross%3E861570364%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=861570364&rft_id=info:pmid/&rft_els_id=S0029549309006281&rfr_iscdi=true