Glycated haemoglobin; past, present, and future are we ready for the change

Glycated haemoglobin has been in use to monitor control of blood glucose in diabetic patients for about three decades. It provides an average blood glucose level during preceding 10-12 weeks. It is a very convenient blood test, can be done in any clinical setting regardless of prandial state. There...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the Pakistan Medical Association 2011-04, Vol.61 (4), p.383-388
1. Verfasser: Syed, Iftikhar Ahmad Asim
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 388
container_issue 4
container_start_page 383
container_title Journal of the Pakistan Medical Association
container_volume 61
creator Syed, Iftikhar Ahmad Asim
description Glycated haemoglobin has been in use to monitor control of blood glucose in diabetic patients for about three decades. It provides an average blood glucose level during preceding 10-12 weeks. It is a very convenient blood test, can be done in any clinical setting regardless of prandial state. There were thirty different laboratory methods available to measure glycated haemoglobin with significant variability of results on same sample. IFCC developed a new reference method to measure the glycated haemoglobin, and the method is accepted world wide as only valid anchor for the measurement of HbA1c. In 2009 International expert committee recommended the use of HbA1c to diagnose diabetes with a threshold 6.5%. IFCC recommended the use of a new unit, i.e., mmol HbA1c/mol of total haemoglobin in place of percentage. Meanwhile a trial was conducted to find out relationship between average blood glucose and glycated haemoglobin, and a linear regression equation was developed to measure average blood glucose from HbA1c. Using the equation one can calculate average blood glucose from glycated haemoglobin in mmol/mol. This average blood glucose will be reported as "eAG" (estimated average glucose) and it will be used to monitor glucose control as eGFR (estimated glomerular filtration rate) is used to monitor renal function in chronic kidney disease patients. How easy or difficult would it be to abandon a term and a unit, in use for three decades and introducing a new unit (mmol/mol) and even a new term (eAG); only time will tell. Health professionals will need to familiarize with new term and units, they will also have to spend more time with their patients to educate them about new developments.
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_860882937</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>860882937</sourcerecordid><originalsourceid>FETCH-LOGICAL-p240t-a53105383e3d6edce65d062b5655518607aaa05e8cacdda6bc97d5d6dd9b801c3</originalsourceid><addsrcrecordid>eNpFz09LxDAQBfAcFHdd_QqSi3ixMG2aNMGTLLqKC170XKbJdLfSfyYt0m9vYSsehvcOPx7MGVsDCIiM0cmKXYbwBZAoCXDBVkmcKmkys2Zvu3qyOJDjR6SmO9RdUbUPvMcw3PPeU6B2Ltg6Xo7D6InjfD_EPaGbeNl5PhyJ2yO2B7pi5yXWga6X3LDP56eP7Uu0f9-9bh_3UZ-kMEQoRQxSaEHCKXKWlHSgkkIqKWWsFWSICJK0RescqsKazEmnnDOFhtiKDbs77fa--x4pDHlTBUt1jS11Y8jnCa0TI7JZ3ixyLBpyee-rBv2U__0_g9sFYLBYlx5bW4V_l8ZxmmoQvwUyYkY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>860882937</pqid></control><display><type>article</type><title>Glycated haemoglobin; past, present, and future are we ready for the change</title><source>MEDLINE</source><source>DOAJ Directory of Open Access Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>Syed, Iftikhar Ahmad Asim</creator><creatorcontrib>Syed, Iftikhar Ahmad Asim</creatorcontrib><description>Glycated haemoglobin has been in use to monitor control of blood glucose in diabetic patients for about three decades. It provides an average blood glucose level during preceding 10-12 weeks. It is a very convenient blood test, can be done in any clinical setting regardless of prandial state. There were thirty different laboratory methods available to measure glycated haemoglobin with significant variability of results on same sample. IFCC developed a new reference method to measure the glycated haemoglobin, and the method is accepted world wide as only valid anchor for the measurement of HbA1c. In 2009 International expert committee recommended the use of HbA1c to diagnose diabetes with a threshold 6.5%. IFCC recommended the use of a new unit, i.e., mmol HbA1c/mol of total haemoglobin in place of percentage. Meanwhile a trial was conducted to find out relationship between average blood glucose and glycated haemoglobin, and a linear regression equation was developed to measure average blood glucose from HbA1c. Using the equation one can calculate average blood glucose from glycated haemoglobin in mmol/mol. This average blood glucose will be reported as "eAG" (estimated average glucose) and it will be used to monitor glucose control as eGFR (estimated glomerular filtration rate) is used to monitor renal function in chronic kidney disease patients. How easy or difficult would it be to abandon a term and a unit, in use for three decades and introducing a new unit (mmol/mol) and even a new term (eAG); only time will tell. Health professionals will need to familiarize with new term and units, they will also have to spend more time with their patients to educate them about new developments.</description><identifier>ISSN: 0030-9982</identifier><identifier>PMID: 21465979</identifier><identifier>CODEN: JJPAD4</identifier><language>eng</language><publisher>Karachi: Pakistan Medical Association</publisher><subject>Biological and medical sciences ; Biomarkers - analysis ; Blood Glucose - metabolism ; Diabetes Mellitus, Type 1 - blood ; Diabetes Mellitus, Type 1 - diagnosis ; Diabetes Mellitus, Type 1 - therapy ; Diabetes Mellitus, Type 2 - blood ; Diabetes Mellitus, Type 2 - diagnosis ; Diabetes Mellitus, Type 2 - therapy ; Forecasting ; General aspects ; Glycated Hemoglobin A - analysis ; Glycated Hemoglobin A - standards ; Humans ; Hypoglycemic Agents - therapeutic use ; International System of Units ; Medical sciences ; Practice Guidelines as Topic ; Reference Standards ; Reference Values</subject><ispartof>Journal of the Pakistan Medical Association, 2011-04, Vol.61 (4), p.383-388</ispartof><rights>2015 INIST-CNRS</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=24114480$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21465979$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Syed, Iftikhar Ahmad Asim</creatorcontrib><title>Glycated haemoglobin; past, present, and future are we ready for the change</title><title>Journal of the Pakistan Medical Association</title><addtitle>J Pak Med Assoc</addtitle><description>Glycated haemoglobin has been in use to monitor control of blood glucose in diabetic patients for about three decades. It provides an average blood glucose level during preceding 10-12 weeks. It is a very convenient blood test, can be done in any clinical setting regardless of prandial state. There were thirty different laboratory methods available to measure glycated haemoglobin with significant variability of results on same sample. IFCC developed a new reference method to measure the glycated haemoglobin, and the method is accepted world wide as only valid anchor for the measurement of HbA1c. In 2009 International expert committee recommended the use of HbA1c to diagnose diabetes with a threshold 6.5%. IFCC recommended the use of a new unit, i.e., mmol HbA1c/mol of total haemoglobin in place of percentage. Meanwhile a trial was conducted to find out relationship between average blood glucose and glycated haemoglobin, and a linear regression equation was developed to measure average blood glucose from HbA1c. Using the equation one can calculate average blood glucose from glycated haemoglobin in mmol/mol. This average blood glucose will be reported as "eAG" (estimated average glucose) and it will be used to monitor glucose control as eGFR (estimated glomerular filtration rate) is used to monitor renal function in chronic kidney disease patients. How easy or difficult would it be to abandon a term and a unit, in use for three decades and introducing a new unit (mmol/mol) and even a new term (eAG); only time will tell. Health professionals will need to familiarize with new term and units, they will also have to spend more time with their patients to educate them about new developments.</description><subject>Biological and medical sciences</subject><subject>Biomarkers - analysis</subject><subject>Blood Glucose - metabolism</subject><subject>Diabetes Mellitus, Type 1 - blood</subject><subject>Diabetes Mellitus, Type 1 - diagnosis</subject><subject>Diabetes Mellitus, Type 1 - therapy</subject><subject>Diabetes Mellitus, Type 2 - blood</subject><subject>Diabetes Mellitus, Type 2 - diagnosis</subject><subject>Diabetes Mellitus, Type 2 - therapy</subject><subject>Forecasting</subject><subject>General aspects</subject><subject>Glycated Hemoglobin A - analysis</subject><subject>Glycated Hemoglobin A - standards</subject><subject>Humans</subject><subject>Hypoglycemic Agents - therapeutic use</subject><subject>International System of Units</subject><subject>Medical sciences</subject><subject>Practice Guidelines as Topic</subject><subject>Reference Standards</subject><subject>Reference Values</subject><issn>0030-9982</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFz09LxDAQBfAcFHdd_QqSi3ixMG2aNMGTLLqKC170XKbJdLfSfyYt0m9vYSsehvcOPx7MGVsDCIiM0cmKXYbwBZAoCXDBVkmcKmkys2Zvu3qyOJDjR6SmO9RdUbUPvMcw3PPeU6B2Ltg6Xo7D6InjfD_EPaGbeNl5PhyJ2yO2B7pi5yXWga6X3LDP56eP7Uu0f9-9bh_3UZ-kMEQoRQxSaEHCKXKWlHSgkkIqKWWsFWSICJK0RescqsKazEmnnDOFhtiKDbs77fa--x4pDHlTBUt1jS11Y8jnCa0TI7JZ3ixyLBpyee-rBv2U__0_g9sFYLBYlx5bW4V_l8ZxmmoQvwUyYkY</recordid><startdate>20110401</startdate><enddate>20110401</enddate><creator>Syed, Iftikhar Ahmad Asim</creator><general>Pakistan Medical Association</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>20110401</creationdate><title>Glycated haemoglobin; past, present, and future are we ready for the change</title><author>Syed, Iftikhar Ahmad Asim</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p240t-a53105383e3d6edce65d062b5655518607aaa05e8cacdda6bc97d5d6dd9b801c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Biological and medical sciences</topic><topic>Biomarkers - analysis</topic><topic>Blood Glucose - metabolism</topic><topic>Diabetes Mellitus, Type 1 - blood</topic><topic>Diabetes Mellitus, Type 1 - diagnosis</topic><topic>Diabetes Mellitus, Type 1 - therapy</topic><topic>Diabetes Mellitus, Type 2 - blood</topic><topic>Diabetes Mellitus, Type 2 - diagnosis</topic><topic>Diabetes Mellitus, Type 2 - therapy</topic><topic>Forecasting</topic><topic>General aspects</topic><topic>Glycated Hemoglobin A - analysis</topic><topic>Glycated Hemoglobin A - standards</topic><topic>Humans</topic><topic>Hypoglycemic Agents - therapeutic use</topic><topic>International System of Units</topic><topic>Medical sciences</topic><topic>Practice Guidelines as Topic</topic><topic>Reference Standards</topic><topic>Reference Values</topic><toplevel>online_resources</toplevel><creatorcontrib>Syed, Iftikhar Ahmad Asim</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of the Pakistan Medical Association</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Syed, Iftikhar Ahmad Asim</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Glycated haemoglobin; past, present, and future are we ready for the change</atitle><jtitle>Journal of the Pakistan Medical Association</jtitle><addtitle>J Pak Med Assoc</addtitle><date>2011-04-01</date><risdate>2011</risdate><volume>61</volume><issue>4</issue><spage>383</spage><epage>388</epage><pages>383-388</pages><issn>0030-9982</issn><coden>JJPAD4</coden><abstract>Glycated haemoglobin has been in use to monitor control of blood glucose in diabetic patients for about three decades. It provides an average blood glucose level during preceding 10-12 weeks. It is a very convenient blood test, can be done in any clinical setting regardless of prandial state. There were thirty different laboratory methods available to measure glycated haemoglobin with significant variability of results on same sample. IFCC developed a new reference method to measure the glycated haemoglobin, and the method is accepted world wide as only valid anchor for the measurement of HbA1c. In 2009 International expert committee recommended the use of HbA1c to diagnose diabetes with a threshold 6.5%. IFCC recommended the use of a new unit, i.e., mmol HbA1c/mol of total haemoglobin in place of percentage. Meanwhile a trial was conducted to find out relationship between average blood glucose and glycated haemoglobin, and a linear regression equation was developed to measure average blood glucose from HbA1c. Using the equation one can calculate average blood glucose from glycated haemoglobin in mmol/mol. This average blood glucose will be reported as "eAG" (estimated average glucose) and it will be used to monitor glucose control as eGFR (estimated glomerular filtration rate) is used to monitor renal function in chronic kidney disease patients. How easy or difficult would it be to abandon a term and a unit, in use for three decades and introducing a new unit (mmol/mol) and even a new term (eAG); only time will tell. Health professionals will need to familiarize with new term and units, they will also have to spend more time with their patients to educate them about new developments.</abstract><cop>Karachi</cop><pub>Pakistan Medical Association</pub><pmid>21465979</pmid><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0030-9982
ispartof Journal of the Pakistan Medical Association, 2011-04, Vol.61 (4), p.383-388
issn 0030-9982
language eng
recordid cdi_proquest_miscellaneous_860882937
source MEDLINE; DOAJ Directory of Open Access Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Biological and medical sciences
Biomarkers - analysis
Blood Glucose - metabolism
Diabetes Mellitus, Type 1 - blood
Diabetes Mellitus, Type 1 - diagnosis
Diabetes Mellitus, Type 1 - therapy
Diabetes Mellitus, Type 2 - blood
Diabetes Mellitus, Type 2 - diagnosis
Diabetes Mellitus, Type 2 - therapy
Forecasting
General aspects
Glycated Hemoglobin A - analysis
Glycated Hemoglobin A - standards
Humans
Hypoglycemic Agents - therapeutic use
International System of Units
Medical sciences
Practice Guidelines as Topic
Reference Standards
Reference Values
title Glycated haemoglobin; past, present, and future are we ready for the change
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T05%3A24%3A00IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Glycated%20haemoglobin;%20past,%20present,%20and%20future%20are%20we%20ready%20for%20the%20change&rft.jtitle=Journal%20of%20the%20Pakistan%20Medical%20Association&rft.au=Syed,%20Iftikhar%20Ahmad%20Asim&rft.date=2011-04-01&rft.volume=61&rft.issue=4&rft.spage=383&rft.epage=388&rft.pages=383-388&rft.issn=0030-9982&rft.coden=JJPAD4&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E860882937%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=860882937&rft_id=info:pmid/21465979&rfr_iscdi=true