Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance

We present the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our optimal pre-launch knowledge of the LFI scientific performance. T...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Astronomy and astrophysics (Berlin) 2010-09, Vol.520, p.A5
Hauptverfasser: Mennella, A., Bersanelli, M., Butler, R. C., Cuttaia, F., D'Arcangelo, O., Davis, R. J., Frailis, M., Galeotta, S., Gregorio, A., Lawrence, C. R., Leonardi, R., Lowe, S. R., Mandolesi, N., Maris, M., Meinhold, P., Mendes, L., Morgante, G., Sandri, M., Stringhetti, L., Terenzi, L., Tomasi, M., Valenziano, L., Villa, F., Zacchei, A., Zonca, A., Balasini, M., Franceschet, C., Battaglia, P., Lapolla, P. M., Leutenegger, P., Miccolis, M., Pagan, L., Silvestri, R., Aja, B., Artal, E., Baldan, G., Bastia, P., Bernardino, T., Boschini, L., Cafagna, G., Cappellini, B., Cavaliere, F., Colombo, F., de La Fuente, L., Edgeley, J., Falvella, M. C., Ferrari, F., Fogliani, S., Franceschi, E., Gaier, T., Gomez, F., Herreros, J. M., Hildebrandt, S., Hoyland, R., Hughes, N., Jukkala, P., Kettle, D., Laaninen, M., Lawson, D., Leahy, P., Levin, S., Lilje, P. B., Maino, D., Malaspina, M., Manzato, P., Marti-Canales, J., Martinez-Gonzalez, E., Mediavilla, A., Pasian, F., Pascual, J. P., Pecora, M., Peres-Cuevas, L., Platania, P., Pospieszalsky, M., Poutanen, T., Rebolo, R., Roddis, N., Salmon, M., Seiffert, M., Simonetto, A., Sozzi, C., Tauber, J., Tuovinen, J., Varis, J., Wilkinson, A., Winder, F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We present the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our optimal pre-launch knowledge of the LFI scientific performance. The LFI shows excellent 1/f stability and rejection of instrumental systematic effects; its measured noise performance shows that LFI is the most sensitive instrument of its kind. The calibration parameters will be updated during flight operations until the end of the mission.
ISSN:0004-6361
1432-0746
DOI:10.1051/0004-6361/200912849