The effect on the pullout strength by the timing of pedicle screw insertion after calcium phosphate cement injection

Biomechanical Cadaveric Study. To characterize the pullout strength of calcium phosphate cement augmented screws between 0 and 6 minutes after cement injection. Earlier studies with calcium phosphate cement on pedicle screws inserted into a metal mold or sawbone have shown that the augmentation stre...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of spinal disorders & techniques 2011-04, Vol.24 (2), p.116-120
Hauptverfasser: Cho, Woojin, Wu, Chunhui, Erkan, Serkan, Kang, Matthew M, Mehbod, Amir A, Transfeldt, Ensor E
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 120
container_issue 2
container_start_page 116
container_title Journal of spinal disorders & techniques
container_volume 24
creator Cho, Woojin
Wu, Chunhui
Erkan, Serkan
Kang, Matthew M
Mehbod, Amir A
Transfeldt, Ensor E
description Biomechanical Cadaveric Study. To characterize the pullout strength of calcium phosphate cement augmented screws between 0 and 6 minutes after cement injection. Earlier studies with calcium phosphate cement on pedicle screws inserted into a metal mold or sawbone have shown that the augmentation strength can be affected by the time between cement injection and screw insertion. However, these studies only compared soft cement to completely hardened cement with extended waiting times. These extended waiting times are impractical in live spinal surgeries. Twenty-four pedicle screws were inserted and pulled out axially from cadaveric bone to make revision models. The 24 screw holes were randomly divided into 4 groups, with each group having 6 holes. For each group, identical pedicle screws were inserted at 0, 2, 4, and 6 minutes after injection with bioresorbable calcium phosphate cement (CPC). After 24 hours, the augmented screws were pulled out axially and their pullout strengths were compared. The difference between secondary pullout strength and primary pullout strength increased up to 4 minutes after cement injection but decreased after 6 minutes but without statistical difference among the 4 time settings (P>0.3). The augmented screws had similar fixation strength regardless of the time between cement mixture and screw insertion as long as they are inserted within 6 minutes. Augmentation power tends to increase up to 4 minutes after cement injection but decreases after 6 minutes.
doi_str_mv 10.1097/bsd.0b013e3181dd7961
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_859289007</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>859289007</sourcerecordid><originalsourceid>FETCH-LOGICAL-c423t-20e8a062cc87ebf0e9254cd0c6feda650387b5a41b50d6d1ed8d6caa7a2e7ddb3</originalsourceid><addsrcrecordid>eNpdkEtPwzAQhC0EoqXwDxDyjVPK2rGd5AjlKVXiQDlHjr1pU-WF7Qj13xNK4cBpd0ff7EhDyCWDOYMsuSm8nUMBLMaYpczaJFPsiEyZjLOICyWP97uKQEk-IWfebwFYEgtxSiacCSGByykJqw1SLEs0gXYtDePVD3XdDYH64LBdhw0tdns9VE3VrmlX0h5tZWqk3jj8pFXr0YVqdOsyoKNG16YaGtpvOt9vdEBqsME2jOB2jBnBc3JS6trjxWHOyPvjw2rxHC1fn14Wt8vICB6HiAOmGhQ3Jk2wKAEzLoWxYFSJVisJcZoUUgtWSLDKMrSpVUbrRHNMrC3iGbn--du77mNAH_Km8gbrWrfYDT5PZcbTDCAZSfFDGtd577DMe1c12u1yBvl33fnd233-v-7RdnUIGIoG7Z_pt9_4C3JVf9I</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>859289007</pqid></control><display><type>article</type><title>The effect on the pullout strength by the timing of pedicle screw insertion after calcium phosphate cement injection</title><source>MEDLINE</source><source>Journals@Ovid Complete</source><creator>Cho, Woojin ; Wu, Chunhui ; Erkan, Serkan ; Kang, Matthew M ; Mehbod, Amir A ; Transfeldt, Ensor E</creator><creatorcontrib>Cho, Woojin ; Wu, Chunhui ; Erkan, Serkan ; Kang, Matthew M ; Mehbod, Amir A ; Transfeldt, Ensor E</creatorcontrib><description>Biomechanical Cadaveric Study. To characterize the pullout strength of calcium phosphate cement augmented screws between 0 and 6 minutes after cement injection. Earlier studies with calcium phosphate cement on pedicle screws inserted into a metal mold or sawbone have shown that the augmentation strength can be affected by the time between cement injection and screw insertion. However, these studies only compared soft cement to completely hardened cement with extended waiting times. These extended waiting times are impractical in live spinal surgeries. Twenty-four pedicle screws were inserted and pulled out axially from cadaveric bone to make revision models. The 24 screw holes were randomly divided into 4 groups, with each group having 6 holes. For each group, identical pedicle screws were inserted at 0, 2, 4, and 6 minutes after injection with bioresorbable calcium phosphate cement (CPC). After 24 hours, the augmented screws were pulled out axially and their pullout strengths were compared. The difference between secondary pullout strength and primary pullout strength increased up to 4 minutes after cement injection but decreased after 6 minutes but without statistical difference among the 4 time settings (P&gt;0.3). The augmented screws had similar fixation strength regardless of the time between cement mixture and screw insertion as long as they are inserted within 6 minutes. Augmentation power tends to increase up to 4 minutes after cement injection but decreases after 6 minutes.</description><identifier>ISSN: 1536-0652</identifier><identifier>EISSN: 1539-2465</identifier><identifier>DOI: 10.1097/bsd.0b013e3181dd7961</identifier><identifier>PMID: 21445025</identifier><language>eng</language><publisher>United States</publisher><subject>Bone Cements ; Bone Screws ; Calcium Phosphates ; Female ; Humans ; Internal Fixators ; Male ; Materials Testing ; Spine - surgery</subject><ispartof>Journal of spinal disorders &amp; techniques, 2011-04, Vol.24 (2), p.116-120</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c423t-20e8a062cc87ebf0e9254cd0c6feda650387b5a41b50d6d1ed8d6caa7a2e7ddb3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,782,786,27933,27934</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21445025$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Cho, Woojin</creatorcontrib><creatorcontrib>Wu, Chunhui</creatorcontrib><creatorcontrib>Erkan, Serkan</creatorcontrib><creatorcontrib>Kang, Matthew M</creatorcontrib><creatorcontrib>Mehbod, Amir A</creatorcontrib><creatorcontrib>Transfeldt, Ensor E</creatorcontrib><title>The effect on the pullout strength by the timing of pedicle screw insertion after calcium phosphate cement injection</title><title>Journal of spinal disorders &amp; techniques</title><addtitle>J Spinal Disord Tech</addtitle><description>Biomechanical Cadaveric Study. To characterize the pullout strength of calcium phosphate cement augmented screws between 0 and 6 minutes after cement injection. Earlier studies with calcium phosphate cement on pedicle screws inserted into a metal mold or sawbone have shown that the augmentation strength can be affected by the time between cement injection and screw insertion. However, these studies only compared soft cement to completely hardened cement with extended waiting times. These extended waiting times are impractical in live spinal surgeries. Twenty-four pedicle screws were inserted and pulled out axially from cadaveric bone to make revision models. The 24 screw holes were randomly divided into 4 groups, with each group having 6 holes. For each group, identical pedicle screws were inserted at 0, 2, 4, and 6 minutes after injection with bioresorbable calcium phosphate cement (CPC). After 24 hours, the augmented screws were pulled out axially and their pullout strengths were compared. The difference between secondary pullout strength and primary pullout strength increased up to 4 minutes after cement injection but decreased after 6 minutes but without statistical difference among the 4 time settings (P&gt;0.3). The augmented screws had similar fixation strength regardless of the time between cement mixture and screw insertion as long as they are inserted within 6 minutes. Augmentation power tends to increase up to 4 minutes after cement injection but decreases after 6 minutes.</description><subject>Bone Cements</subject><subject>Bone Screws</subject><subject>Calcium Phosphates</subject><subject>Female</subject><subject>Humans</subject><subject>Internal Fixators</subject><subject>Male</subject><subject>Materials Testing</subject><subject>Spine - surgery</subject><issn>1536-0652</issn><issn>1539-2465</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpdkEtPwzAQhC0EoqXwDxDyjVPK2rGd5AjlKVXiQDlHjr1pU-WF7Qj13xNK4cBpd0ff7EhDyCWDOYMsuSm8nUMBLMaYpczaJFPsiEyZjLOICyWP97uKQEk-IWfebwFYEgtxSiacCSGByykJqw1SLEs0gXYtDePVD3XdDYH64LBdhw0tdns9VE3VrmlX0h5tZWqk3jj8pFXr0YVqdOsyoKNG16YaGtpvOt9vdEBqsME2jOB2jBnBc3JS6trjxWHOyPvjw2rxHC1fn14Wt8vICB6HiAOmGhQ3Jk2wKAEzLoWxYFSJVisJcZoUUgtWSLDKMrSpVUbrRHNMrC3iGbn--du77mNAH_Km8gbrWrfYDT5PZcbTDCAZSfFDGtd577DMe1c12u1yBvl33fnd233-v-7RdnUIGIoG7Z_pt9_4C3JVf9I</recordid><startdate>201104</startdate><enddate>201104</enddate><creator>Cho, Woojin</creator><creator>Wu, Chunhui</creator><creator>Erkan, Serkan</creator><creator>Kang, Matthew M</creator><creator>Mehbod, Amir A</creator><creator>Transfeldt, Ensor E</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>201104</creationdate><title>The effect on the pullout strength by the timing of pedicle screw insertion after calcium phosphate cement injection</title><author>Cho, Woojin ; Wu, Chunhui ; Erkan, Serkan ; Kang, Matthew M ; Mehbod, Amir A ; Transfeldt, Ensor E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c423t-20e8a062cc87ebf0e9254cd0c6feda650387b5a41b50d6d1ed8d6caa7a2e7ddb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Bone Cements</topic><topic>Bone Screws</topic><topic>Calcium Phosphates</topic><topic>Female</topic><topic>Humans</topic><topic>Internal Fixators</topic><topic>Male</topic><topic>Materials Testing</topic><topic>Spine - surgery</topic><toplevel>online_resources</toplevel><creatorcontrib>Cho, Woojin</creatorcontrib><creatorcontrib>Wu, Chunhui</creatorcontrib><creatorcontrib>Erkan, Serkan</creatorcontrib><creatorcontrib>Kang, Matthew M</creatorcontrib><creatorcontrib>Mehbod, Amir A</creatorcontrib><creatorcontrib>Transfeldt, Ensor E</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of spinal disorders &amp; techniques</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cho, Woojin</au><au>Wu, Chunhui</au><au>Erkan, Serkan</au><au>Kang, Matthew M</au><au>Mehbod, Amir A</au><au>Transfeldt, Ensor E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The effect on the pullout strength by the timing of pedicle screw insertion after calcium phosphate cement injection</atitle><jtitle>Journal of spinal disorders &amp; techniques</jtitle><addtitle>J Spinal Disord Tech</addtitle><date>2011-04</date><risdate>2011</risdate><volume>24</volume><issue>2</issue><spage>116</spage><epage>120</epage><pages>116-120</pages><issn>1536-0652</issn><eissn>1539-2465</eissn><abstract>Biomechanical Cadaveric Study. To characterize the pullout strength of calcium phosphate cement augmented screws between 0 and 6 minutes after cement injection. Earlier studies with calcium phosphate cement on pedicle screws inserted into a metal mold or sawbone have shown that the augmentation strength can be affected by the time between cement injection and screw insertion. However, these studies only compared soft cement to completely hardened cement with extended waiting times. These extended waiting times are impractical in live spinal surgeries. Twenty-four pedicle screws were inserted and pulled out axially from cadaveric bone to make revision models. The 24 screw holes were randomly divided into 4 groups, with each group having 6 holes. For each group, identical pedicle screws were inserted at 0, 2, 4, and 6 minutes after injection with bioresorbable calcium phosphate cement (CPC). After 24 hours, the augmented screws were pulled out axially and their pullout strengths were compared. The difference between secondary pullout strength and primary pullout strength increased up to 4 minutes after cement injection but decreased after 6 minutes but without statistical difference among the 4 time settings (P&gt;0.3). The augmented screws had similar fixation strength regardless of the time between cement mixture and screw insertion as long as they are inserted within 6 minutes. Augmentation power tends to increase up to 4 minutes after cement injection but decreases after 6 minutes.</abstract><cop>United States</cop><pmid>21445025</pmid><doi>10.1097/bsd.0b013e3181dd7961</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1536-0652
ispartof Journal of spinal disorders & techniques, 2011-04, Vol.24 (2), p.116-120
issn 1536-0652
1539-2465
language eng
recordid cdi_proquest_miscellaneous_859289007
source MEDLINE; Journals@Ovid Complete
subjects Bone Cements
Bone Screws
Calcium Phosphates
Female
Humans
Internal Fixators
Male
Materials Testing
Spine - surgery
title The effect on the pullout strength by the timing of pedicle screw insertion after calcium phosphate cement injection
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-11-29T18%3A35%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20effect%20on%20the%20pullout%20strength%20by%20the%20timing%20of%20pedicle%20screw%20insertion%20after%20calcium%20phosphate%20cement%20injection&rft.jtitle=Journal%20of%20spinal%20disorders%20&%20techniques&rft.au=Cho,%20Woojin&rft.date=2011-04&rft.volume=24&rft.issue=2&rft.spage=116&rft.epage=120&rft.pages=116-120&rft.issn=1536-0652&rft.eissn=1539-2465&rft_id=info:doi/10.1097/bsd.0b013e3181dd7961&rft_dat=%3Cproquest_cross%3E859289007%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=859289007&rft_id=info:pmid/21445025&rfr_iscdi=true