Reliability of the Lagrange and Rigault classification system of supracondylar humerus extension fractures in children
Summary Introduction The Lagrange and Rigault classification was designed to describe extension-type supracondylar fractures of the humerus. It can also help in treatment decision-making. Hypothesis The reliability of this classification has not yet been proven. The goal of this study was to assess...
Gespeichert in:
Veröffentlicht in: | Orthopaedics & traumatology, surgery & research surgery & research, 2010-10, Vol.96 (6), p.652-655 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Summary Introduction The Lagrange and Rigault classification was designed to describe extension-type supracondylar fractures of the humerus. It can also help in treatment decision-making. Hypothesis The reliability of this classification has not yet been proven. The goal of this study was to assess this system's intra- and interobserver reliability. Methods One hundred supracondylar fracture radiographs were randomly retrieved and reviewed by five different observers on two occasions in a different order. The kappa index was used to calculate the intra- and interobserver reliability. Results Intraobserver reliability was 0.76 and interobserver reliability was 0.69. Discussion The study shows good intra- and interobserver reliability. The Lagrange and Rigault classification has similar reliability to other supracondylar fracture classifications. |
---|---|
ISSN: | 1877-0568 1877-0568 |
DOI: | 10.1016/j.otsr.2010.03.021 |