Large exchange bias after zero-field cooling from an unmagnetized state
Exchange bias (EB) is usually observed in systems with an interface between different magnetic phases after field cooling. Here we report an unusual phenomenon in which a large EB can be observed in Ni-Mn-In bulk alloys after zero-field cooling from an unmagnetized state. We propose that this is rel...
Gespeichert in:
Veröffentlicht in: | Physical review letters 2011-02, Vol.106 (7), p.077203-077203, Article 077203 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 077203 |
---|---|
container_issue | 7 |
container_start_page | 077203 |
container_title | Physical review letters |
container_volume | 106 |
creator | Wang, B M Liu, Y Ren, P Xia, B Ruan, K B Yi, J B Ding, J Li, X G Wang, L |
description | Exchange bias (EB) is usually observed in systems with an interface between different magnetic phases after field cooling. Here we report an unusual phenomenon in which a large EB can be observed in Ni-Mn-In bulk alloys after zero-field cooling from an unmagnetized state. We propose that this is related to the newly formed interface between different magnetic phases during the initial magnetization process. The magnetic unidirectional anisotropy, which is the origin of the EB effect, can be created isothermally below the blocking temperature. |
doi_str_mv | 10.1103/PhysRevLett.106.077203 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_857483768</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>857483768</sourcerecordid><originalsourceid>FETCH-LOGICAL-c411t-2eaa63871e63e9df7c42d2de142f71ab20091d3a20431abe308b8e3163eb7df93</originalsourceid><addsrcrecordid>eNpNkE1Lw0AQhhdRbK3-hbI3T6kzu2k2OUrRKhQU0XPYZGfbSD7q7kZsf72RVvE0HzzvDDyMTRFmiCBvnjc7_0KfKwphhpDMQCkB8oSNEVQWKcT4lI0BJEYZgBqxC-_fAQBFkp6zkcAY5nOZjdlypd2aOH2VG90OTVFpz7UN5PieXBfZimrDy66rq3bNresarlvet41etxSqPRnugw50yc6srj1dHeuEvd3fvS4eotXT8nFxu4rKGDFEgrROZKqQEkmZsaqMhRGGMBZWoS4EQIZGagGxHEaSkBYpSRzoQhmbyQm7Ptzduu6jJx_ypvIl1bVuqet9ns5VnEqVpAOZHMjSdd47svnWVY12uxwh_3GY_3M47JL84HAITo8v-qIh8xf7lSa_AeBDcFM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>857483768</pqid></control><display><type>article</type><title>Large exchange bias after zero-field cooling from an unmagnetized state</title><source>PROLA</source><creator>Wang, B M ; Liu, Y ; Ren, P ; Xia, B ; Ruan, K B ; Yi, J B ; Ding, J ; Li, X G ; Wang, L</creator><creatorcontrib>Wang, B M ; Liu, Y ; Ren, P ; Xia, B ; Ruan, K B ; Yi, J B ; Ding, J ; Li, X G ; Wang, L</creatorcontrib><description>Exchange bias (EB) is usually observed in systems with an interface between different magnetic phases after field cooling. Here we report an unusual phenomenon in which a large EB can be observed in Ni-Mn-In bulk alloys after zero-field cooling from an unmagnetized state. We propose that this is related to the newly formed interface between different magnetic phases during the initial magnetization process. The magnetic unidirectional anisotropy, which is the origin of the EB effect, can be created isothermally below the blocking temperature.</description><identifier>ISSN: 0031-9007</identifier><identifier>EISSN: 1079-7114</identifier><identifier>DOI: 10.1103/PhysRevLett.106.077203</identifier><identifier>PMID: 21405539</identifier><language>eng</language><publisher>United States</publisher><ispartof>Physical review letters, 2011-02, Vol.106 (7), p.077203-077203, Article 077203</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c411t-2eaa63871e63e9df7c42d2de142f71ab20091d3a20431abe308b8e3163eb7df93</citedby><cites>FETCH-LOGICAL-c411t-2eaa63871e63e9df7c42d2de142f71ab20091d3a20431abe308b8e3163eb7df93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,2876,2877,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21405539$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Wang, B M</creatorcontrib><creatorcontrib>Liu, Y</creatorcontrib><creatorcontrib>Ren, P</creatorcontrib><creatorcontrib>Xia, B</creatorcontrib><creatorcontrib>Ruan, K B</creatorcontrib><creatorcontrib>Yi, J B</creatorcontrib><creatorcontrib>Ding, J</creatorcontrib><creatorcontrib>Li, X G</creatorcontrib><creatorcontrib>Wang, L</creatorcontrib><title>Large exchange bias after zero-field cooling from an unmagnetized state</title><title>Physical review letters</title><addtitle>Phys Rev Lett</addtitle><description>Exchange bias (EB) is usually observed in systems with an interface between different magnetic phases after field cooling. Here we report an unusual phenomenon in which a large EB can be observed in Ni-Mn-In bulk alloys after zero-field cooling from an unmagnetized state. We propose that this is related to the newly formed interface between different magnetic phases during the initial magnetization process. The magnetic unidirectional anisotropy, which is the origin of the EB effect, can be created isothermally below the blocking temperature.</description><issn>0031-9007</issn><issn>1079-7114</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNpNkE1Lw0AQhhdRbK3-hbI3T6kzu2k2OUrRKhQU0XPYZGfbSD7q7kZsf72RVvE0HzzvDDyMTRFmiCBvnjc7_0KfKwphhpDMQCkB8oSNEVQWKcT4lI0BJEYZgBqxC-_fAQBFkp6zkcAY5nOZjdlypd2aOH2VG90OTVFpz7UN5PieXBfZimrDy66rq3bNresarlvet41etxSqPRnugw50yc6srj1dHeuEvd3fvS4eotXT8nFxu4rKGDFEgrROZKqQEkmZsaqMhRGGMBZWoS4EQIZGagGxHEaSkBYpSRzoQhmbyQm7Ptzduu6jJx_ypvIl1bVuqet9ns5VnEqVpAOZHMjSdd47svnWVY12uxwh_3GY_3M47JL84HAITo8v-qIh8xf7lSa_AeBDcFM</recordid><startdate>20110218</startdate><enddate>20110218</enddate><creator>Wang, B M</creator><creator>Liu, Y</creator><creator>Ren, P</creator><creator>Xia, B</creator><creator>Ruan, K B</creator><creator>Yi, J B</creator><creator>Ding, J</creator><creator>Li, X G</creator><creator>Wang, L</creator><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>20110218</creationdate><title>Large exchange bias after zero-field cooling from an unmagnetized state</title><author>Wang, B M ; Liu, Y ; Ren, P ; Xia, B ; Ruan, K B ; Yi, J B ; Ding, J ; Li, X G ; Wang, L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c411t-2eaa63871e63e9df7c42d2de142f71ab20091d3a20431abe308b8e3163eb7df93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Wang, B M</creatorcontrib><creatorcontrib>Liu, Y</creatorcontrib><creatorcontrib>Ren, P</creatorcontrib><creatorcontrib>Xia, B</creatorcontrib><creatorcontrib>Ruan, K B</creatorcontrib><creatorcontrib>Yi, J B</creatorcontrib><creatorcontrib>Ding, J</creatorcontrib><creatorcontrib>Li, X G</creatorcontrib><creatorcontrib>Wang, L</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Physical review letters</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Wang, B M</au><au>Liu, Y</au><au>Ren, P</au><au>Xia, B</au><au>Ruan, K B</au><au>Yi, J B</au><au>Ding, J</au><au>Li, X G</au><au>Wang, L</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Large exchange bias after zero-field cooling from an unmagnetized state</atitle><jtitle>Physical review letters</jtitle><addtitle>Phys Rev Lett</addtitle><date>2011-02-18</date><risdate>2011</risdate><volume>106</volume><issue>7</issue><spage>077203</spage><epage>077203</epage><pages>077203-077203</pages><artnum>077203</artnum><issn>0031-9007</issn><eissn>1079-7114</eissn><abstract>Exchange bias (EB) is usually observed in systems with an interface between different magnetic phases after field cooling. Here we report an unusual phenomenon in which a large EB can be observed in Ni-Mn-In bulk alloys after zero-field cooling from an unmagnetized state. We propose that this is related to the newly formed interface between different magnetic phases during the initial magnetization process. The magnetic unidirectional anisotropy, which is the origin of the EB effect, can be created isothermally below the blocking temperature.</abstract><cop>United States</cop><pmid>21405539</pmid><doi>10.1103/PhysRevLett.106.077203</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0031-9007 |
ispartof | Physical review letters, 2011-02, Vol.106 (7), p.077203-077203, Article 077203 |
issn | 0031-9007 1079-7114 |
language | eng |
recordid | cdi_proquest_miscellaneous_857483768 |
source | PROLA |
title | Large exchange bias after zero-field cooling from an unmagnetized state |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T11%3A03%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Large%20exchange%20bias%20after%20zero-field%20cooling%20from%20an%20unmagnetized%20state&rft.jtitle=Physical%20review%20letters&rft.au=Wang,%20B%20M&rft.date=2011-02-18&rft.volume=106&rft.issue=7&rft.spage=077203&rft.epage=077203&rft.pages=077203-077203&rft.artnum=077203&rft.issn=0031-9007&rft.eissn=1079-7114&rft_id=info:doi/10.1103/PhysRevLett.106.077203&rft_dat=%3Cproquest_cross%3E857483768%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=857483768&rft_id=info:pmid/21405539&rfr_iscdi=true |