High-Energy X-Ray Microprobe System with Submicron Resolution for X-Ray Fluorescence Analysis of Uranium in Biological Specimens

Total-external-reflection Kirkpatrick-Baez mirror optics for high-energy X-rays have been applied to the X-ray microprobe at beamline 37XU of SPring-8. A focused beam size of 1.0 μm (V)×0.83 μm (H) has been achieved at an X-ray energy of 30 keV, and a total photon flux of the focused beam was about...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:X-ray optics and instrumentation 2010, Vol.2010, p.1-5
Hauptverfasser: Terada, Yasuko, Homma-Takeda, Shino, Takeuchi, Akihisa, Suzuki, Yoshio
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 5
container_issue
container_start_page 1
container_title X-ray optics and instrumentation
container_volume 2010
creator Terada, Yasuko
Homma-Takeda, Shino
Takeuchi, Akihisa
Suzuki, Yoshio
description Total-external-reflection Kirkpatrick-Baez mirror optics for high-energy X-rays have been applied to the X-ray microprobe at beamline 37XU of SPring-8. A focused beam size of 1.0 μm (V)×0.83 μm (H) has been achieved at an X-ray energy of 30 keV, and a total photon flux of the focused beam was about 5×109 photons/s. Micro-X-ray fluorescence (μ-XRF) analysis of the uranium distribution in rat kidneys has been performed with the mirror-focused beam. The sensitivity of uranium was evaluated from the XRF intensity of thin standard samples, and the minimum detection limit was estimated at 10 μg/g. The high-spatial-resolution analysis revealed that uranium was concentrated in the epithelium of the proximal tubules in the inner cortex. The maximum concentration of uranium in the tubule was estimated to be 503 μg/g using a semiquantitative evaluation.
doi_str_mv 10.1155/2010/317909
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_855686511</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>855686511</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2799-f8c1784aeed45cc9148f49395250e6bfdf92f076400167fa3bb84b07a00d414e3</originalsourceid><addsrcrecordid>eNp9kU1LAzEQhhdRsFZP_oHgRVDWTvZ7j7W0VqgIrQVvSzadtCm7SU26lL35083S4sGDpxlmnhnmndfzbik8URrHgwAoDEKa5pCfeT2aZKmfJhGc_-ZhcOldWbsFcGUIet73VK43_lihWbfk05-zlrxJbvTO6BLJorV7rMlB7jdk0ZR111FkjlZXzV66VGhzmppUjTZoOSqOZKhY1VppiRZkaZiSTU2kIs9SV3otOavIYodc1qjstXchWGXx5hT73nIy_hhN_dn7y-toOPN5kOa5LzJO0yxiiKso5jynUSaiPMzjIAZMSrESeSCgEws0SQULyzKLSkgZwCqiEYZ97_641yn7atDui1q6a6uKKdSNLbI4TrIkptSRd3_IrW6MU9RBCYSQUXDQ4xFyH7HWoCh2RtbMtAWFovOi6Lwojl44-uFIb6RasYP8F_4B4biIqw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>856030810</pqid></control><display><type>article</type><title>High-Energy X-Ray Microprobe System with Submicron Resolution for X-Ray Fluorescence Analysis of Uranium in Biological Specimens</title><source>Wiley Online Library Open Access</source><source>Full-Text Journals in Chemistry (Open access)</source><source>Alma/SFX Local Collection</source><source>EZB Electronic Journals Library</source><creator>Terada, Yasuko ; Homma-Takeda, Shino ; Takeuchi, Akihisa ; Suzuki, Yoshio</creator><contributor>Ice, Gene</contributor><creatorcontrib>Terada, Yasuko ; Homma-Takeda, Shino ; Takeuchi, Akihisa ; Suzuki, Yoshio ; Ice, Gene</creatorcontrib><description>Total-external-reflection Kirkpatrick-Baez mirror optics for high-energy X-rays have been applied to the X-ray microprobe at beamline 37XU of SPring-8. A focused beam size of 1.0 μm (V)×0.83 μm (H) has been achieved at an X-ray energy of 30 keV, and a total photon flux of the focused beam was about 5×109 photons/s. Micro-X-ray fluorescence (μ-XRF) analysis of the uranium distribution in rat kidneys has been performed with the mirror-focused beam. The sensitivity of uranium was evaluated from the XRF intensity of thin standard samples, and the minimum detection limit was estimated at 10 μg/g. The high-spatial-resolution analysis revealed that uranium was concentrated in the epithelium of the proximal tubules in the inner cortex. The maximum concentration of uranium in the tubule was estimated to be 503 μg/g using a semiquantitative evaluation.</description><identifier>ISSN: 1687-7632</identifier><identifier>EISSN: 1687-7640</identifier><identifier>DOI: 10.1155/2010/317909</identifier><language>eng</language><publisher>New York: Hindawi Publishing Corporation</publisher><subject>Beams (radiation) ; Epithelium ; Fluorescence ; Flux ; Instrumentation ; Kidneys ; Laboratory animals ; Mass spectrometry ; Photons ; Polyvinyl alcohol ; Rodents ; Uranium ; X-rays</subject><ispartof>X-ray optics and instrumentation, 2010, Vol.2010, p.1-5</ispartof><rights>Copyright © 2010</rights><rights>Copyright © 2010 Yasuko Terada et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2799-f8c1784aeed45cc9148f49395250e6bfdf92f076400167fa3bb84b07a00d414e3</citedby><cites>FETCH-LOGICAL-c2799-f8c1784aeed45cc9148f49395250e6bfdf92f076400167fa3bb84b07a00d414e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,4010,27900,27901,27902</link.rule.ids></links><search><contributor>Ice, Gene</contributor><creatorcontrib>Terada, Yasuko</creatorcontrib><creatorcontrib>Homma-Takeda, Shino</creatorcontrib><creatorcontrib>Takeuchi, Akihisa</creatorcontrib><creatorcontrib>Suzuki, Yoshio</creatorcontrib><title>High-Energy X-Ray Microprobe System with Submicron Resolution for X-Ray Fluorescence Analysis of Uranium in Biological Specimens</title><title>X-ray optics and instrumentation</title><description>Total-external-reflection Kirkpatrick-Baez mirror optics for high-energy X-rays have been applied to the X-ray microprobe at beamline 37XU of SPring-8. A focused beam size of 1.0 μm (V)×0.83 μm (H) has been achieved at an X-ray energy of 30 keV, and a total photon flux of the focused beam was about 5×109 photons/s. Micro-X-ray fluorescence (μ-XRF) analysis of the uranium distribution in rat kidneys has been performed with the mirror-focused beam. The sensitivity of uranium was evaluated from the XRF intensity of thin standard samples, and the minimum detection limit was estimated at 10 μg/g. The high-spatial-resolution analysis revealed that uranium was concentrated in the epithelium of the proximal tubules in the inner cortex. The maximum concentration of uranium in the tubule was estimated to be 503 μg/g using a semiquantitative evaluation.</description><subject>Beams (radiation)</subject><subject>Epithelium</subject><subject>Fluorescence</subject><subject>Flux</subject><subject>Instrumentation</subject><subject>Kidneys</subject><subject>Laboratory animals</subject><subject>Mass spectrometry</subject><subject>Photons</subject><subject>Polyvinyl alcohol</subject><subject>Rodents</subject><subject>Uranium</subject><subject>X-rays</subject><issn>1687-7632</issn><issn>1687-7640</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid>RHX</sourceid><sourceid>BENPR</sourceid><recordid>eNp9kU1LAzEQhhdRsFZP_oHgRVDWTvZ7j7W0VqgIrQVvSzadtCm7SU26lL35083S4sGDpxlmnhnmndfzbik8URrHgwAoDEKa5pCfeT2aZKmfJhGc_-ZhcOldWbsFcGUIet73VK43_lihWbfk05-zlrxJbvTO6BLJorV7rMlB7jdk0ZR111FkjlZXzV66VGhzmppUjTZoOSqOZKhY1VppiRZkaZiSTU2kIs9SV3otOavIYodc1qjstXchWGXx5hT73nIy_hhN_dn7y-toOPN5kOa5LzJO0yxiiKso5jynUSaiPMzjIAZMSrESeSCgEws0SQULyzKLSkgZwCqiEYZ97_641yn7atDui1q6a6uKKdSNLbI4TrIkptSRd3_IrW6MU9RBCYSQUXDQ4xFyH7HWoCh2RtbMtAWFovOi6Lwojl44-uFIb6RasYP8F_4B4biIqw</recordid><startdate>2010</startdate><enddate>2010</enddate><creator>Terada, Yasuko</creator><creator>Homma-Takeda, Shino</creator><creator>Takeuchi, Akihisa</creator><creator>Suzuki, Yoshio</creator><general>Hindawi Publishing Corporation</general><general>Hindawi Limited</general><scope>RHU</scope><scope>RHW</scope><scope>RHX</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FE</scope><scope>8FG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>P5Z</scope><scope>P62</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7SP</scope><scope>7U5</scope><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>2010</creationdate><title>High-Energy X-Ray Microprobe System with Submicron Resolution for X-Ray Fluorescence Analysis of Uranium in Biological Specimens</title><author>Terada, Yasuko ; Homma-Takeda, Shino ; Takeuchi, Akihisa ; Suzuki, Yoshio</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2799-f8c1784aeed45cc9148f49395250e6bfdf92f076400167fa3bb84b07a00d414e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Beams (radiation)</topic><topic>Epithelium</topic><topic>Fluorescence</topic><topic>Flux</topic><topic>Instrumentation</topic><topic>Kidneys</topic><topic>Laboratory animals</topic><topic>Mass spectrometry</topic><topic>Photons</topic><topic>Polyvinyl alcohol</topic><topic>Rodents</topic><topic>Uranium</topic><topic>X-rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Terada, Yasuko</creatorcontrib><creatorcontrib>Homma-Takeda, Shino</creatorcontrib><creatorcontrib>Takeuchi, Akihisa</creatorcontrib><creatorcontrib>Suzuki, Yoshio</creatorcontrib><collection>Hindawi Publishing Complete</collection><collection>Hindawi Publishing Subscription Journals</collection><collection>Hindawi Publishing Open Access Journals</collection><collection>CrossRef</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>SciTech Premium Collection</collection><collection>ProQuest advanced technologies &amp; aerospace journals</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>X-ray optics and instrumentation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Terada, Yasuko</au><au>Homma-Takeda, Shino</au><au>Takeuchi, Akihisa</au><au>Suzuki, Yoshio</au><au>Ice, Gene</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High-Energy X-Ray Microprobe System with Submicron Resolution for X-Ray Fluorescence Analysis of Uranium in Biological Specimens</atitle><jtitle>X-ray optics and instrumentation</jtitle><date>2010</date><risdate>2010</risdate><volume>2010</volume><spage>1</spage><epage>5</epage><pages>1-5</pages><issn>1687-7632</issn><eissn>1687-7640</eissn><abstract>Total-external-reflection Kirkpatrick-Baez mirror optics for high-energy X-rays have been applied to the X-ray microprobe at beamline 37XU of SPring-8. A focused beam size of 1.0 μm (V)×0.83 μm (H) has been achieved at an X-ray energy of 30 keV, and a total photon flux of the focused beam was about 5×109 photons/s. Micro-X-ray fluorescence (μ-XRF) analysis of the uranium distribution in rat kidneys has been performed with the mirror-focused beam. The sensitivity of uranium was evaluated from the XRF intensity of thin standard samples, and the minimum detection limit was estimated at 10 μg/g. The high-spatial-resolution analysis revealed that uranium was concentrated in the epithelium of the proximal tubules in the inner cortex. The maximum concentration of uranium in the tubule was estimated to be 503 μg/g using a semiquantitative evaluation.</abstract><cop>New York</cop><pub>Hindawi Publishing Corporation</pub><doi>10.1155/2010/317909</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1687-7632
ispartof X-ray optics and instrumentation, 2010, Vol.2010, p.1-5
issn 1687-7632
1687-7640
language eng
recordid cdi_proquest_miscellaneous_855686511
source Wiley Online Library Open Access; Full-Text Journals in Chemistry (Open access); Alma/SFX Local Collection; EZB Electronic Journals Library
subjects Beams (radiation)
Epithelium
Fluorescence
Flux
Instrumentation
Kidneys
Laboratory animals
Mass spectrometry
Photons
Polyvinyl alcohol
Rodents
Uranium
X-rays
title High-Energy X-Ray Microprobe System with Submicron Resolution for X-Ray Fluorescence Analysis of Uranium in Biological Specimens
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T17%3A14%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High-Energy%20X-Ray%20Microprobe%20System%20with%20Submicron%20Resolution%20for%20X-Ray%20Fluorescence%20Analysis%20of%20Uranium%20in%20Biological%20Specimens&rft.jtitle=X-ray%20optics%20and%20instrumentation&rft.au=Terada,%20Yasuko&rft.date=2010&rft.volume=2010&rft.spage=1&rft.epage=5&rft.pages=1-5&rft.issn=1687-7632&rft.eissn=1687-7640&rft_id=info:doi/10.1155/2010/317909&rft_dat=%3Cproquest_cross%3E855686511%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=856030810&rft_id=info:pmid/&rfr_iscdi=true