In-Plane Experimental Testing of Timber-Concrete Composite Floor Diaphragms

Recent advances in multistory timber building design have led to new structural systems that allow open floor plans with large spans between frames and/or walls. Timber-concrete composite (TCC) flooring can achieve the spans required but has the potential to be flexible under diaphragm actions, whic...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of structural engineering (New York, N.Y.) N.Y.), 2010-11, Vol.136 (11), p.1461-1468
Hauptverfasser: Newcombe, Michael P, van Beerschoten, Wouter A, Carradine, David, Pampanin, Stefano, Buchanan, Andrew H
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1468
container_issue 11
container_start_page 1461
container_title Journal of structural engineering (New York, N.Y.)
container_volume 136
creator Newcombe, Michael P
van Beerschoten, Wouter A
Carradine, David
Pampanin, Stefano
Buchanan, Andrew H
description Recent advances in multistory timber building design have led to new structural systems that allow open floor plans with large spans between frames and/or walls. Timber-concrete composite (TCC) flooring can achieve the spans required but has the potential to be flexible under diaphragm actions, which can significantly alter the seismic response of a building. In-plane experimental tests on a 3 m by 3 m one-third scale TCC floor were performed using quasi-static earthquake loading simulation. The experimental results indicate that the deformation between the floor and lateral load resisting systems (LLRS) is much greater than the in-plane deformation of the floor diaphragm. Hence, a floor system with similar aspect ratio can be modeled as a single-degree-of-freedom for future structural analyses. Different connections were considered between the floor unit and lateral restraints, which simulate the LLRS. The connection was either timber-to-timber or concrete-to-timber and incorporated screws or nails acting as dowels or inclined at 45°. Each connection type performed differently in terms of stiffness, strength, ductility capacity, and induced damage. Screws that were oriented at 45° to the connection interface were significantly stiffer than fasteners aligned orthogonal to the interface. There was little difference in the initial stiffness for the concrete-to-timber connection compared to the timber-to-timber connection. The testing indicated that a timber-to-timber interface is more desirable because of construction ease and reparability. The in-plane response of the floor system is modeled using finite elements and compared to experimental results. Design recommendations are provided for the cyclic strength of inclined wood fasteners.
doi_str_mv 10.1061/(ASCE)ST.1943-541X.0000239
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_849467922</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>849467922</sourcerecordid><originalsourceid>FETCH-LOGICAL-a341t-3f76a3caf4d81c4f672305a86cdb4587ffdf58182996886b0193d0f371ea4be83</originalsourceid><addsrcrecordid>eNp1kF9LwzAUxYMoOKffofiiPnQmTZo_vo26qThQWAXfQtoms6NtatKBfntTNvbmfbmXyzmXe34AXCM4Q5Ci-9v5OlvcrfMZEgTHKUGfMxgqweIETI67UzCBDONYEJKegwvvt0HDUsQn4PWli98b1elo8dNrV7e6G1QT5doPdbeJrInyui20izPblU4POsps21tfh2nZWOuix1r1X05tWn8JzoxqvL469Cn4WC7y7DlevT29ZPNVrDBBQ4wNowqXypCKo5IYyhIMU8VpWRUk5cyYyqQc8UQIyjktIBK4ggYzpBUpNMdTcLO_2zv7vQufyrb2pW7GGHbnJSeCUCaSJCgf9srSWe-dNrIPEZX7lQjKEaCUI0C5zuUIS46w5AFgMNO9WYXjcmt3rgupjs7_jX9aU3VK</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>849467922</pqid></control><display><type>article</type><title>In-Plane Experimental Testing of Timber-Concrete Composite Floor Diaphragms</title><source>American Society of Civil Engineers:NESLI2:Journals:2014</source><creator>Newcombe, Michael P ; van Beerschoten, Wouter A ; Carradine, David ; Pampanin, Stefano ; Buchanan, Andrew H</creator><creatorcontrib>Newcombe, Michael P ; van Beerschoten, Wouter A ; Carradine, David ; Pampanin, Stefano ; Buchanan, Andrew H</creatorcontrib><description>Recent advances in multistory timber building design have led to new structural systems that allow open floor plans with large spans between frames and/or walls. Timber-concrete composite (TCC) flooring can achieve the spans required but has the potential to be flexible under diaphragm actions, which can significantly alter the seismic response of a building. In-plane experimental tests on a 3 m by 3 m one-third scale TCC floor were performed using quasi-static earthquake loading simulation. The experimental results indicate that the deformation between the floor and lateral load resisting systems (LLRS) is much greater than the in-plane deformation of the floor diaphragm. Hence, a floor system with similar aspect ratio can be modeled as a single-degree-of-freedom for future structural analyses. Different connections were considered between the floor unit and lateral restraints, which simulate the LLRS. The connection was either timber-to-timber or concrete-to-timber and incorporated screws or nails acting as dowels or inclined at 45°. Each connection type performed differently in terms of stiffness, strength, ductility capacity, and induced damage. Screws that were oriented at 45° to the connection interface were significantly stiffer than fasteners aligned orthogonal to the interface. There was little difference in the initial stiffness for the concrete-to-timber connection compared to the timber-to-timber connection. The testing indicated that a timber-to-timber interface is more desirable because of construction ease and reparability. The in-plane response of the floor system is modeled using finite elements and compared to experimental results. Design recommendations are provided for the cyclic strength of inclined wood fasteners.</description><identifier>ISSN: 0733-9445</identifier><identifier>EISSN: 1943-541X</identifier><identifier>DOI: 10.1061/(ASCE)ST.1943-541X.0000239</identifier><language>eng</language><publisher>American Society of Civil Engineers</publisher><subject>TECHNICAL PAPERS</subject><ispartof>Journal of structural engineering (New York, N.Y.), 2010-11, Vol.136 (11), p.1461-1468</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a341t-3f76a3caf4d81c4f672305a86cdb4587ffdf58182996886b0193d0f371ea4be83</citedby><cites>FETCH-LOGICAL-a341t-3f76a3caf4d81c4f672305a86cdb4587ffdf58182996886b0193d0f371ea4be83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttp://ascelibrary.org/doi/pdf/10.1061/(ASCE)ST.1943-541X.0000239$$EPDF$$P50$$Gasce$$H</linktopdf><linktohtml>$$Uhttp://ascelibrary.org/doi/abs/10.1061/(ASCE)ST.1943-541X.0000239$$EHTML$$P50$$Gasce$$H</linktohtml><link.rule.ids>314,776,780,27903,27904,75939,75947</link.rule.ids></links><search><creatorcontrib>Newcombe, Michael P</creatorcontrib><creatorcontrib>van Beerschoten, Wouter A</creatorcontrib><creatorcontrib>Carradine, David</creatorcontrib><creatorcontrib>Pampanin, Stefano</creatorcontrib><creatorcontrib>Buchanan, Andrew H</creatorcontrib><title>In-Plane Experimental Testing of Timber-Concrete Composite Floor Diaphragms</title><title>Journal of structural engineering (New York, N.Y.)</title><description>Recent advances in multistory timber building design have led to new structural systems that allow open floor plans with large spans between frames and/or walls. Timber-concrete composite (TCC) flooring can achieve the spans required but has the potential to be flexible under diaphragm actions, which can significantly alter the seismic response of a building. In-plane experimental tests on a 3 m by 3 m one-third scale TCC floor were performed using quasi-static earthquake loading simulation. The experimental results indicate that the deformation between the floor and lateral load resisting systems (LLRS) is much greater than the in-plane deformation of the floor diaphragm. Hence, a floor system with similar aspect ratio can be modeled as a single-degree-of-freedom for future structural analyses. Different connections were considered between the floor unit and lateral restraints, which simulate the LLRS. The connection was either timber-to-timber or concrete-to-timber and incorporated screws or nails acting as dowels or inclined at 45°. Each connection type performed differently in terms of stiffness, strength, ductility capacity, and induced damage. Screws that were oriented at 45° to the connection interface were significantly stiffer than fasteners aligned orthogonal to the interface. There was little difference in the initial stiffness for the concrete-to-timber connection compared to the timber-to-timber connection. The testing indicated that a timber-to-timber interface is more desirable because of construction ease and reparability. The in-plane response of the floor system is modeled using finite elements and compared to experimental results. Design recommendations are provided for the cyclic strength of inclined wood fasteners.</description><subject>TECHNICAL PAPERS</subject><issn>0733-9445</issn><issn>1943-541X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNp1kF9LwzAUxYMoOKffofiiPnQmTZo_vo26qThQWAXfQtoms6NtatKBfntTNvbmfbmXyzmXe34AXCM4Q5Ci-9v5OlvcrfMZEgTHKUGfMxgqweIETI67UzCBDONYEJKegwvvt0HDUsQn4PWli98b1elo8dNrV7e6G1QT5doPdbeJrInyui20izPblU4POsps21tfh2nZWOuix1r1X05tWn8JzoxqvL469Cn4WC7y7DlevT29ZPNVrDBBQ4wNowqXypCKo5IYyhIMU8VpWRUk5cyYyqQc8UQIyjktIBK4ggYzpBUpNMdTcLO_2zv7vQufyrb2pW7GGHbnJSeCUCaSJCgf9srSWe-dNrIPEZX7lQjKEaCUI0C5zuUIS46w5AFgMNO9WYXjcmt3rgupjs7_jX9aU3VK</recordid><startdate>201011</startdate><enddate>201011</enddate><creator>Newcombe, Michael P</creator><creator>van Beerschoten, Wouter A</creator><creator>Carradine, David</creator><creator>Pampanin, Stefano</creator><creator>Buchanan, Andrew H</creator><general>American Society of Civil Engineers</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7T2</scope><scope>7U2</scope><scope>C1K</scope></search><sort><creationdate>201011</creationdate><title>In-Plane Experimental Testing of Timber-Concrete Composite Floor Diaphragms</title><author>Newcombe, Michael P ; van Beerschoten, Wouter A ; Carradine, David ; Pampanin, Stefano ; Buchanan, Andrew H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a341t-3f76a3caf4d81c4f672305a86cdb4587ffdf58182996886b0193d0f371ea4be83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>TECHNICAL PAPERS</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Newcombe, Michael P</creatorcontrib><creatorcontrib>van Beerschoten, Wouter A</creatorcontrib><creatorcontrib>Carradine, David</creatorcontrib><creatorcontrib>Pampanin, Stefano</creatorcontrib><creatorcontrib>Buchanan, Andrew H</creatorcontrib><collection>CrossRef</collection><collection>Health and Safety Science Abstracts (Full archive)</collection><collection>Safety Science and Risk</collection><collection>Environmental Sciences and Pollution Management</collection><jtitle>Journal of structural engineering (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Newcombe, Michael P</au><au>van Beerschoten, Wouter A</au><au>Carradine, David</au><au>Pampanin, Stefano</au><au>Buchanan, Andrew H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>In-Plane Experimental Testing of Timber-Concrete Composite Floor Diaphragms</atitle><jtitle>Journal of structural engineering (New York, N.Y.)</jtitle><date>2010-11</date><risdate>2010</risdate><volume>136</volume><issue>11</issue><spage>1461</spage><epage>1468</epage><pages>1461-1468</pages><issn>0733-9445</issn><eissn>1943-541X</eissn><abstract>Recent advances in multistory timber building design have led to new structural systems that allow open floor plans with large spans between frames and/or walls. Timber-concrete composite (TCC) flooring can achieve the spans required but has the potential to be flexible under diaphragm actions, which can significantly alter the seismic response of a building. In-plane experimental tests on a 3 m by 3 m one-third scale TCC floor were performed using quasi-static earthquake loading simulation. The experimental results indicate that the deformation between the floor and lateral load resisting systems (LLRS) is much greater than the in-plane deformation of the floor diaphragm. Hence, a floor system with similar aspect ratio can be modeled as a single-degree-of-freedom for future structural analyses. Different connections were considered between the floor unit and lateral restraints, which simulate the LLRS. The connection was either timber-to-timber or concrete-to-timber and incorporated screws or nails acting as dowels or inclined at 45°. Each connection type performed differently in terms of stiffness, strength, ductility capacity, and induced damage. Screws that were oriented at 45° to the connection interface were significantly stiffer than fasteners aligned orthogonal to the interface. There was little difference in the initial stiffness for the concrete-to-timber connection compared to the timber-to-timber connection. The testing indicated that a timber-to-timber interface is more desirable because of construction ease and reparability. The in-plane response of the floor system is modeled using finite elements and compared to experimental results. Design recommendations are provided for the cyclic strength of inclined wood fasteners.</abstract><pub>American Society of Civil Engineers</pub><doi>10.1061/(ASCE)ST.1943-541X.0000239</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0733-9445
ispartof Journal of structural engineering (New York, N.Y.), 2010-11, Vol.136 (11), p.1461-1468
issn 0733-9445
1943-541X
language eng
recordid cdi_proquest_miscellaneous_849467922
source American Society of Civil Engineers:NESLI2:Journals:2014
subjects TECHNICAL PAPERS
title In-Plane Experimental Testing of Timber-Concrete Composite Floor Diaphragms
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T14%3A31%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=In-Plane%20Experimental%20Testing%20of%20Timber-Concrete%20Composite%20Floor%20Diaphragms&rft.jtitle=Journal%20of%20structural%20engineering%20(New%20York,%20N.Y.)&rft.au=Newcombe,%20Michael%20P&rft.date=2010-11&rft.volume=136&rft.issue=11&rft.spage=1461&rft.epage=1468&rft.pages=1461-1468&rft.issn=0733-9445&rft.eissn=1943-541X&rft_id=info:doi/10.1061/(ASCE)ST.1943-541X.0000239&rft_dat=%3Cproquest_cross%3E849467922%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=849467922&rft_id=info:pmid/&rfr_iscdi=true