Electrophoretic and immunologic differences between monoclonal IgM molecules and their subunits in native plasma

Naturally occurring IgM subunits had a higher negative charge than those obtained after mercaptoethanol reduction of 19 S IgM and higher polymers. Both types of subunits regularly had a stronger negative charge than the pentamers. Extension of the immunoelectrophoretic IgM precipitation line on the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Immunochemistry (1965) 1970-06, Vol.7 (6), p.559,IN7-560,IN7
Hauptverfasser: Hansson, U.-B., Laurell, C.-B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 560,IN7
container_issue 6
container_start_page 559,IN7
container_title Immunochemistry (1965)
container_volume 7
creator Hansson, U.-B.
Laurell, C.-B.
description Naturally occurring IgM subunits had a higher negative charge than those obtained after mercaptoethanol reduction of 19 S IgM and higher polymers. Both types of subunits regularly had a stronger negative charge than the pentamers. Extension of the immunoelectrophoretic IgM precipitation line on the anodal side of the 19 S M-component component indicated occurrence of subunits if trailing could be excluded. The precipitation patterns were easier to interpret when electroendoosmotic inert support media were used for electrophoresis. In most cases antigen-antibody crossed electrophoresis allowed semiquantitative estimation of proportions between mono- and pentamers. Of 32 sera with increased monoclonal IgM, 25 were found to contain measurable amounts of 7 S IgM. Quantitative precipitin and gel diffusion studies showed that maximal amounts of precipitates with anti-IgM were obtained in antigen excess for 19 S IgM, but an equivalence for 7 S IgM.
doi_str_mv 10.1016/0019-2791(70)90276-4
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_84753553</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0019279170902764</els_id><sourcerecordid>84753553</sourcerecordid><originalsourceid>FETCH-LOGICAL-c357t-7841e2fb8671058563943dd530ff5c452fbe10b73b651e7cc5e5910cd5729673</originalsourceid><addsrcrecordid>eNp9kE1PwyAcxjlodL58A004GT1UYYVSLibGzJdE42V30tJ_NwyFCu2M317qlh09kYfnhfBD6IKSW0pocUcIldlcSHotyI0kc1Fk7ADN9tfH6CTGz0lKJo_QEZOSliWZoX5hQQ_B92sfYDAaV67BputG561fJd2YtoUATkPENQzfAA533nltvassfl29J5k2RpsCU3lYgwk4jvXozBCxcdhVg9kA7m0Vu-oMHbaVjXC-O0_R8mmxfHzJ3j6eXx8f3jKdczFkomQU5m1dFoISXvIilyxvGp6TtuWa8WQBJbXI64JTEFpz4JIS3XAxl4XIT9HVdrYP_muEOKjORA3WVg78GFXJBM85z1OQbYM6-BgDtKoPpqvCj6JETWzVRE1NEJUg6o-tYql2udsf6w6afWkHNvn3Wx_SHzcGgoraTBQbExJw1Xjz_wO_7R2MFQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>84753553</pqid></control><display><type>article</type><title>Electrophoretic and immunologic differences between monoclonal IgM molecules and their subunits in native plasma</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Hansson, U.-B. ; Laurell, C.-B.</creator><creatorcontrib>Hansson, U.-B. ; Laurell, C.-B.</creatorcontrib><description>Naturally occurring IgM subunits had a higher negative charge than those obtained after mercaptoethanol reduction of 19 S IgM and higher polymers. Both types of subunits regularly had a stronger negative charge than the pentamers. Extension of the immunoelectrophoretic IgM precipitation line on the anodal side of the 19 S M-component component indicated occurrence of subunits if trailing could be excluded. The precipitation patterns were easier to interpret when electroendoosmotic inert support media were used for electrophoresis. In most cases antigen-antibody crossed electrophoresis allowed semiquantitative estimation of proportions between mono- and pentamers. Of 32 sera with increased monoclonal IgM, 25 were found to contain measurable amounts of 7 S IgM. Quantitative precipitin and gel diffusion studies showed that maximal amounts of precipitates with anti-IgM were obtained in antigen excess for 19 S IgM, but an equivalence for 7 S IgM.</description><identifier>ISSN: 0019-2791</identifier><identifier>DOI: 10.1016/0019-2791(70)90276-4</identifier><identifier>PMID: 4991880</identifier><language>eng</language><publisher>England: Elsevier B.V</publisher><subject>Animals ; Antigen-Antibody Reactions ; Humans ; Immunodiffusion ; Immunoelectrophoresis ; Immunoglobulin G ; Immunoglobulin M - analysis ; Immunoglobulins - analysis ; Mercaptoethanol ; Polymers ; Precipitin Tests ; Rabbits ; Waldenstrom Macroglobulinemia</subject><ispartof>Immunochemistry (1965), 1970-06, Vol.7 (6), p.559,IN7-560,IN7</ispartof><rights>1970</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c357t-7841e2fb8671058563943dd530ff5c452fbe10b73b651e7cc5e5910cd5729673</citedby><cites>FETCH-LOGICAL-c357t-7841e2fb8671058563943dd530ff5c452fbe10b73b651e7cc5e5910cd5729673</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/4991880$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hansson, U.-B.</creatorcontrib><creatorcontrib>Laurell, C.-B.</creatorcontrib><title>Electrophoretic and immunologic differences between monoclonal IgM molecules and their subunits in native plasma</title><title>Immunochemistry (1965)</title><addtitle>Immunochemistry</addtitle><description>Naturally occurring IgM subunits had a higher negative charge than those obtained after mercaptoethanol reduction of 19 S IgM and higher polymers. Both types of subunits regularly had a stronger negative charge than the pentamers. Extension of the immunoelectrophoretic IgM precipitation line on the anodal side of the 19 S M-component component indicated occurrence of subunits if trailing could be excluded. The precipitation patterns were easier to interpret when electroendoosmotic inert support media were used for electrophoresis. In most cases antigen-antibody crossed electrophoresis allowed semiquantitative estimation of proportions between mono- and pentamers. Of 32 sera with increased monoclonal IgM, 25 were found to contain measurable amounts of 7 S IgM. Quantitative precipitin and gel diffusion studies showed that maximal amounts of precipitates with anti-IgM were obtained in antigen excess for 19 S IgM, but an equivalence for 7 S IgM.</description><subject>Animals</subject><subject>Antigen-Antibody Reactions</subject><subject>Humans</subject><subject>Immunodiffusion</subject><subject>Immunoelectrophoresis</subject><subject>Immunoglobulin G</subject><subject>Immunoglobulin M - analysis</subject><subject>Immunoglobulins - analysis</subject><subject>Mercaptoethanol</subject><subject>Polymers</subject><subject>Precipitin Tests</subject><subject>Rabbits</subject><subject>Waldenstrom Macroglobulinemia</subject><issn>0019-2791</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1970</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE1PwyAcxjlodL58A004GT1UYYVSLibGzJdE42V30tJ_NwyFCu2M317qlh09kYfnhfBD6IKSW0pocUcIldlcSHotyI0kc1Fk7ADN9tfH6CTGz0lKJo_QEZOSliWZoX5hQQ_B92sfYDAaV67BputG561fJd2YtoUATkPENQzfAA533nltvassfl29J5k2RpsCU3lYgwk4jvXozBCxcdhVg9kA7m0Vu-oMHbaVjXC-O0_R8mmxfHzJ3j6eXx8f3jKdczFkomQU5m1dFoISXvIilyxvGp6TtuWa8WQBJbXI64JTEFpz4JIS3XAxl4XIT9HVdrYP_muEOKjORA3WVg78GFXJBM85z1OQbYM6-BgDtKoPpqvCj6JETWzVRE1NEJUg6o-tYql2udsf6w6afWkHNvn3Wx_SHzcGgoraTBQbExJw1Xjz_wO_7R2MFQ</recordid><startdate>197006</startdate><enddate>197006</enddate><creator>Hansson, U.-B.</creator><creator>Laurell, C.-B.</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>197006</creationdate><title>Electrophoretic and immunologic differences between monoclonal IgM molecules and their subunits in native plasma</title><author>Hansson, U.-B. ; Laurell, C.-B.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c357t-7841e2fb8671058563943dd530ff5c452fbe10b73b651e7cc5e5910cd5729673</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1970</creationdate><topic>Animals</topic><topic>Antigen-Antibody Reactions</topic><topic>Humans</topic><topic>Immunodiffusion</topic><topic>Immunoelectrophoresis</topic><topic>Immunoglobulin G</topic><topic>Immunoglobulin M - analysis</topic><topic>Immunoglobulins - analysis</topic><topic>Mercaptoethanol</topic><topic>Polymers</topic><topic>Precipitin Tests</topic><topic>Rabbits</topic><topic>Waldenstrom Macroglobulinemia</topic><toplevel>online_resources</toplevel><creatorcontrib>Hansson, U.-B.</creatorcontrib><creatorcontrib>Laurell, C.-B.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Immunochemistry (1965)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hansson, U.-B.</au><au>Laurell, C.-B.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Electrophoretic and immunologic differences between monoclonal IgM molecules and their subunits in native plasma</atitle><jtitle>Immunochemistry (1965)</jtitle><addtitle>Immunochemistry</addtitle><date>1970-06</date><risdate>1970</risdate><volume>7</volume><issue>6</issue><spage>559,IN7</spage><epage>560,IN7</epage><pages>559,IN7-560,IN7</pages><issn>0019-2791</issn><abstract>Naturally occurring IgM subunits had a higher negative charge than those obtained after mercaptoethanol reduction of 19 S IgM and higher polymers. Both types of subunits regularly had a stronger negative charge than the pentamers. Extension of the immunoelectrophoretic IgM precipitation line on the anodal side of the 19 S M-component component indicated occurrence of subunits if trailing could be excluded. The precipitation patterns were easier to interpret when electroendoosmotic inert support media were used for electrophoresis. In most cases antigen-antibody crossed electrophoresis allowed semiquantitative estimation of proportions between mono- and pentamers. Of 32 sera with increased monoclonal IgM, 25 were found to contain measurable amounts of 7 S IgM. Quantitative precipitin and gel diffusion studies showed that maximal amounts of precipitates with anti-IgM were obtained in antigen excess for 19 S IgM, but an equivalence for 7 S IgM.</abstract><cop>England</cop><pub>Elsevier B.V</pub><pmid>4991880</pmid><doi>10.1016/0019-2791(70)90276-4</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0019-2791
ispartof Immunochemistry (1965), 1970-06, Vol.7 (6), p.559,IN7-560,IN7
issn 0019-2791
language eng
recordid cdi_proquest_miscellaneous_84753553
source MEDLINE; Alma/SFX Local Collection
subjects Animals
Antigen-Antibody Reactions
Humans
Immunodiffusion
Immunoelectrophoresis
Immunoglobulin G
Immunoglobulin M - analysis
Immunoglobulins - analysis
Mercaptoethanol
Polymers
Precipitin Tests
Rabbits
Waldenstrom Macroglobulinemia
title Electrophoretic and immunologic differences between monoclonal IgM molecules and their subunits in native plasma
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T12%3A39%3A46IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Electrophoretic%20and%20immunologic%20differences%20between%20monoclonal%20IgM%20molecules%20and%20their%20subunits%20in%20native%20plasma&rft.jtitle=Immunochemistry%20(1965)&rft.au=Hansson,%20U.-B.&rft.date=1970-06&rft.volume=7&rft.issue=6&rft.spage=559,IN7&rft.epage=560,IN7&rft.pages=559,IN7-560,IN7&rft.issn=0019-2791&rft_id=info:doi/10.1016/0019-2791(70)90276-4&rft_dat=%3Cproquest_cross%3E84753553%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=84753553&rft_id=info:pmid/4991880&rft_els_id=0019279170902764&rfr_iscdi=true