New method for fast continuous measurement of the lip-opening area

An electronic device for measuring the articulatory parameter ’’lip-opening area’’ is presented. The measurement rate is 50 values per second. Utilizing the video signal of a TV camera, the device produces a voltage proportional to the dark area of the mouth opening surrounded by a bright boundary (...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of the Acoustical Society of America 1977-08, Vol.62 (2), p.474-476
1. Verfasser: Kretschmar, J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 476
container_issue 2
container_start_page 474
container_title The Journal of the Acoustical Society of America
container_volume 62
creator Kretschmar, J
description An electronic device for measuring the articulatory parameter ’’lip-opening area’’ is presented. The measurement rate is 50 values per second. Utilizing the video signal of a TV camera, the device produces a voltage proportional to the dark area of the mouth opening surrounded by a bright boundary (lips painted white). High contrast is achieved by using fluorescent paint and ultraviolet illumination. As an example, a measured lip-opening area is shown as a function of time.
doi_str_mv 10.1121/1.381514
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_84012902</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>84012902</sourcerecordid><originalsourceid>FETCH-LOGICAL-c277t-27b9abde7aa0c147bb62d2ea3ee8e45fff848bdcd7fee63cfe3b4814489a97df3</originalsourceid><addsrcrecordid>eNo9kEtLxDAUhYP4GkfBH-AiK3HTMa826dIZfMGgG12XpLlxKm1TkxTx31vp4OpyuB-Hw4fQJSUrShm9pSuuaE7FAVrQnJFM5UwcogUhhGaiLIpTdBbj5xRzxcsTdKxUQRRfoPULfOMO0s5b7HzATseEa9-nph_9GKeXjmOADvqEvcNpB7hthswP0Df9B9YB9Dk6crqNcLG_S_T-cP-2ecq2r4_Pm7ttVjMpU8akKbWxILUmNRXSmIJZBpoDKBC5c04JZWxtpQMoeO2AG6GoEKrUpbSOL9H13DsE_zVCTFXXxBraVvcwTa2UIJSVhE3gzQzWwccYwFVDaDodfipKqj9bFa1mWxN6te8cTQf2H5z18F-qhmUG</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>84012902</pqid></control><display><type>article</type><title>New method for fast continuous measurement of the lip-opening area</title><source>MEDLINE</source><source>AIP Acoustical Society of America</source><creator>Kretschmar, J</creator><creatorcontrib>Kretschmar, J</creatorcontrib><description>An electronic device for measuring the articulatory parameter ’’lip-opening area’’ is presented. The measurement rate is 50 values per second. Utilizing the video signal of a TV camera, the device produces a voltage proportional to the dark area of the mouth opening surrounded by a bright boundary (lips painted white). High contrast is achieved by using fluorescent paint and ultraviolet illumination. As an example, a measured lip-opening area is shown as a function of time.</description><identifier>ISSN: 0001-4966</identifier><identifier>EISSN: 1520-8524</identifier><identifier>DOI: 10.1121/1.381514</identifier><identifier>PMID: 886083</identifier><language>eng</language><publisher>United States</publisher><subject>Electronics - instrumentation ; Fluorescence ; Humans ; Lip ; Mouth ; Speech - physiology ; Television ; Tongue ; Tooth ; Ultraviolet Rays</subject><ispartof>The Journal of the Acoustical Society of America, 1977-08, Vol.62 (2), p.474-476</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c277t-27b9abde7aa0c147bb62d2ea3ee8e45fff848bdcd7fee63cfe3b4814489a97df3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>207,314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/886083$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kretschmar, J</creatorcontrib><title>New method for fast continuous measurement of the lip-opening area</title><title>The Journal of the Acoustical Society of America</title><addtitle>J Acoust Soc Am</addtitle><description>An electronic device for measuring the articulatory parameter ’’lip-opening area’’ is presented. The measurement rate is 50 values per second. Utilizing the video signal of a TV camera, the device produces a voltage proportional to the dark area of the mouth opening surrounded by a bright boundary (lips painted white). High contrast is achieved by using fluorescent paint and ultraviolet illumination. As an example, a measured lip-opening area is shown as a function of time.</description><subject>Electronics - instrumentation</subject><subject>Fluorescence</subject><subject>Humans</subject><subject>Lip</subject><subject>Mouth</subject><subject>Speech - physiology</subject><subject>Television</subject><subject>Tongue</subject><subject>Tooth</subject><subject>Ultraviolet Rays</subject><issn>0001-4966</issn><issn>1520-8524</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1977</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kEtLxDAUhYP4GkfBH-AiK3HTMa826dIZfMGgG12XpLlxKm1TkxTx31vp4OpyuB-Hw4fQJSUrShm9pSuuaE7FAVrQnJFM5UwcogUhhGaiLIpTdBbj5xRzxcsTdKxUQRRfoPULfOMO0s5b7HzATseEa9-nph_9GKeXjmOADvqEvcNpB7hthswP0Df9B9YB9Dk6crqNcLG_S_T-cP-2ecq2r4_Pm7ttVjMpU8akKbWxILUmNRXSmIJZBpoDKBC5c04JZWxtpQMoeO2AG6GoEKrUpbSOL9H13DsE_zVCTFXXxBraVvcwTa2UIJSVhE3gzQzWwccYwFVDaDodfipKqj9bFa1mWxN6te8cTQf2H5z18F-qhmUG</recordid><startdate>197708</startdate><enddate>197708</enddate><creator>Kretschmar, J</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>8BM</scope></search><sort><creationdate>197708</creationdate><title>New method for fast continuous measurement of the lip-opening area</title><author>Kretschmar, J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c277t-27b9abde7aa0c147bb62d2ea3ee8e45fff848bdcd7fee63cfe3b4814489a97df3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1977</creationdate><topic>Electronics - instrumentation</topic><topic>Fluorescence</topic><topic>Humans</topic><topic>Lip</topic><topic>Mouth</topic><topic>Speech - physiology</topic><topic>Television</topic><topic>Tongue</topic><topic>Tooth</topic><topic>Ultraviolet Rays</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kretschmar, J</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>ComDisDome</collection><jtitle>The Journal of the Acoustical Society of America</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kretschmar, J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>New method for fast continuous measurement of the lip-opening area</atitle><jtitle>The Journal of the Acoustical Society of America</jtitle><addtitle>J Acoust Soc Am</addtitle><date>1977-08</date><risdate>1977</risdate><volume>62</volume><issue>2</issue><spage>474</spage><epage>476</epage><pages>474-476</pages><issn>0001-4966</issn><eissn>1520-8524</eissn><abstract>An electronic device for measuring the articulatory parameter ’’lip-opening area’’ is presented. The measurement rate is 50 values per second. Utilizing the video signal of a TV camera, the device produces a voltage proportional to the dark area of the mouth opening surrounded by a bright boundary (lips painted white). High contrast is achieved by using fluorescent paint and ultraviolet illumination. As an example, a measured lip-opening area is shown as a function of time.</abstract><cop>United States</cop><pmid>886083</pmid><doi>10.1121/1.381514</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0001-4966
ispartof The Journal of the Acoustical Society of America, 1977-08, Vol.62 (2), p.474-476
issn 0001-4966
1520-8524
language eng
recordid cdi_proquest_miscellaneous_84012902
source MEDLINE; AIP Acoustical Society of America
subjects Electronics - instrumentation
Fluorescence
Humans
Lip
Mouth
Speech - physiology
Television
Tongue
Tooth
Ultraviolet Rays
title New method for fast continuous measurement of the lip-opening area
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T01%3A36%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=New%20method%20for%20fast%20continuous%20measurement%20of%20the%20lip-opening%20area&rft.jtitle=The%20Journal%20of%20the%20Acoustical%20Society%20of%20America&rft.au=Kretschmar,%20J&rft.date=1977-08&rft.volume=62&rft.issue=2&rft.spage=474&rft.epage=476&rft.pages=474-476&rft.issn=0001-4966&rft.eissn=1520-8524&rft_id=info:doi/10.1121/1.381514&rft_dat=%3Cproquest_cross%3E84012902%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=84012902&rft_id=info:pmid/886083&rfr_iscdi=true