Angular scattering analysis of the circular dichroism of biological cells. 2. The red blood cell

A detailed interpretation of the grossly distorted ultraviolet absorption and circular dichroism spectra of the intact red blood cell is given, including an evaluation of the effects of protein conformation, detector geometry, cell hemoglobin content, and refractive index on the calculated cell spec...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biochemistry (Easton) 1976-07, Vol.15 (14), p.3138-3145
Hauptverfasser: Gitter-Amir, Adina, Schneider, Allan S, Rosenheck, Kurt
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3145
container_issue 14
container_start_page 3138
container_title Biochemistry (Easton)
container_volume 15
creator Gitter-Amir, Adina
Schneider, Allan S
Rosenheck, Kurt
description A detailed interpretation of the grossly distorted ultraviolet absorption and circular dichroism spectra of the intact red blood cell is given, including an evaluation of the effects of protein conformation, detector geometry, cell hemoglobin content, and refractive index on the calculated cell spectra. The origins of the major differences between cell and hemoglobin solution spectra were quantitatively accounted for in terms of differential scatter and absorption flattening, with the latter effect dominating the picture. The relatively low sensitivity of the red blood cell suspension circular dichroism spectrum to hemoglobin conformation is due to the order of magnitude flattening of circular dichroism intensity. The importance of accounting for instrumental light detection geometry and the intense small angle scattering (less than 8 degrees) for a range of particle sizes (0.1-5 mum) is made clear.
doi_str_mv 10.1021/bi00659a030
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_83520202</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>83520202</sourcerecordid><originalsourceid>FETCH-LOGICAL-a419t-7680ff5f70c9ecf0a6be68f4e550a4c97fc796f46dfd1302dd2e1b6205bbdae93</originalsourceid><addsrcrecordid>eNptkD1PAyEYgInxq1YnVwcmHczVl7uDK2NjrJqYaLQuLsjxUdFrUbhL9N9Le8Y4GAYCz5MX8iB0SGBEICdntQNglEsoYAMNCM0hKzmnm2gACWQ5Z7CL9mJ8TccSqnIHbXOajykM0PNkOe8aGXBUsm1NcMs5lkvZfEUXsbe4fTFYuaDWjnbqJXgXFytSO9_4uVOywco0TRzhfIRnSQ9G47rxXq_v99GWlU00Bz_7ED1OL2bnV9nN7eX1-eQmkyXhbVaxMVhLbQWKG2VBstqwsS0NpSBLxSurKs5sybTVpIBc69yQmuVA61pLw4shOu7nvgf_0ZnYioWLqw_IpfFdFOMiZUkriae9qIKPMRgr3oNbyPAlCIhVTvEnZ7KPfsZ29cLoX7fvl3DWYxdb8_lLZXgTrCoqKmZ3D6K8f5oBuZuKafJPel-qKF59F1Lq-O_D32LAi7M</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>83520202</pqid></control><display><type>article</type><title>Angular scattering analysis of the circular dichroism of biological cells. 2. The red blood cell</title><source>MEDLINE</source><source>American Chemical Society Journals</source><creator>Gitter-Amir, Adina ; Schneider, Allan S ; Rosenheck, Kurt</creator><creatorcontrib>Gitter-Amir, Adina ; Schneider, Allan S ; Rosenheck, Kurt</creatorcontrib><description>A detailed interpretation of the grossly distorted ultraviolet absorption and circular dichroism spectra of the intact red blood cell is given, including an evaluation of the effects of protein conformation, detector geometry, cell hemoglobin content, and refractive index on the calculated cell spectra. The origins of the major differences between cell and hemoglobin solution spectra were quantitatively accounted for in terms of differential scatter and absorption flattening, with the latter effect dominating the picture. The relatively low sensitivity of the red blood cell suspension circular dichroism spectrum to hemoglobin conformation is due to the order of magnitude flattening of circular dichroism intensity. The importance of accounting for instrumental light detection geometry and the intense small angle scattering (less than 8 degrees) for a range of particle sizes (0.1-5 mum) is made clear.</description><identifier>ISSN: 0006-2960</identifier><identifier>EISSN: 1520-4995</identifier><identifier>DOI: 10.1021/bi00659a030</identifier><identifier>PMID: 952850</identifier><language>eng</language><publisher>United States: American Chemical Society</publisher><subject>Circular Dichroism ; Erythrocytes ; Hemoglobins ; Humans ; Models, Chemical ; Protein Conformation ; Scattering, Radiation ; Spectrophotometry, Ultraviolet</subject><ispartof>Biochemistry (Easton), 1976-07, Vol.15 (14), p.3138-3145</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a419t-7680ff5f70c9ecf0a6be68f4e550a4c97fc796f46dfd1302dd2e1b6205bbdae93</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/bi00659a030$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/bi00659a030$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,780,784,2765,27076,27924,27925,56738,56788</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/952850$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gitter-Amir, Adina</creatorcontrib><creatorcontrib>Schneider, Allan S</creatorcontrib><creatorcontrib>Rosenheck, Kurt</creatorcontrib><title>Angular scattering analysis of the circular dichroism of biological cells. 2. The red blood cell</title><title>Biochemistry (Easton)</title><addtitle>Biochemistry</addtitle><description>A detailed interpretation of the grossly distorted ultraviolet absorption and circular dichroism spectra of the intact red blood cell is given, including an evaluation of the effects of protein conformation, detector geometry, cell hemoglobin content, and refractive index on the calculated cell spectra. The origins of the major differences between cell and hemoglobin solution spectra were quantitatively accounted for in terms of differential scatter and absorption flattening, with the latter effect dominating the picture. The relatively low sensitivity of the red blood cell suspension circular dichroism spectrum to hemoglobin conformation is due to the order of magnitude flattening of circular dichroism intensity. The importance of accounting for instrumental light detection geometry and the intense small angle scattering (less than 8 degrees) for a range of particle sizes (0.1-5 mum) is made clear.</description><subject>Circular Dichroism</subject><subject>Erythrocytes</subject><subject>Hemoglobins</subject><subject>Humans</subject><subject>Models, Chemical</subject><subject>Protein Conformation</subject><subject>Scattering, Radiation</subject><subject>Spectrophotometry, Ultraviolet</subject><issn>0006-2960</issn><issn>1520-4995</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1976</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNptkD1PAyEYgInxq1YnVwcmHczVl7uDK2NjrJqYaLQuLsjxUdFrUbhL9N9Le8Y4GAYCz5MX8iB0SGBEICdntQNglEsoYAMNCM0hKzmnm2gACWQ5Z7CL9mJ8TccSqnIHbXOajykM0PNkOe8aGXBUsm1NcMs5lkvZfEUXsbe4fTFYuaDWjnbqJXgXFytSO9_4uVOywco0TRzhfIRnSQ9G47rxXq_v99GWlU00Bz_7ED1OL2bnV9nN7eX1-eQmkyXhbVaxMVhLbQWKG2VBstqwsS0NpSBLxSurKs5sybTVpIBc69yQmuVA61pLw4shOu7nvgf_0ZnYioWLqw_IpfFdFOMiZUkriae9qIKPMRgr3oNbyPAlCIhVTvEnZ7KPfsZ29cLoX7fvl3DWYxdb8_lLZXgTrCoqKmZ3D6K8f5oBuZuKafJPel-qKF59F1Lq-O_D32LAi7M</recordid><startdate>19760713</startdate><enddate>19760713</enddate><creator>Gitter-Amir, Adina</creator><creator>Schneider, Allan S</creator><creator>Rosenheck, Kurt</creator><general>American Chemical Society</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19760713</creationdate><title>Angular scattering analysis of the circular dichroism of biological cells. 2. The red blood cell</title><author>Gitter-Amir, Adina ; Schneider, Allan S ; Rosenheck, Kurt</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a419t-7680ff5f70c9ecf0a6be68f4e550a4c97fc796f46dfd1302dd2e1b6205bbdae93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1976</creationdate><topic>Circular Dichroism</topic><topic>Erythrocytes</topic><topic>Hemoglobins</topic><topic>Humans</topic><topic>Models, Chemical</topic><topic>Protein Conformation</topic><topic>Scattering, Radiation</topic><topic>Spectrophotometry, Ultraviolet</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gitter-Amir, Adina</creatorcontrib><creatorcontrib>Schneider, Allan S</creatorcontrib><creatorcontrib>Rosenheck, Kurt</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Biochemistry (Easton)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gitter-Amir, Adina</au><au>Schneider, Allan S</au><au>Rosenheck, Kurt</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Angular scattering analysis of the circular dichroism of biological cells. 2. The red blood cell</atitle><jtitle>Biochemistry (Easton)</jtitle><addtitle>Biochemistry</addtitle><date>1976-07-13</date><risdate>1976</risdate><volume>15</volume><issue>14</issue><spage>3138</spage><epage>3145</epage><pages>3138-3145</pages><issn>0006-2960</issn><eissn>1520-4995</eissn><abstract>A detailed interpretation of the grossly distorted ultraviolet absorption and circular dichroism spectra of the intact red blood cell is given, including an evaluation of the effects of protein conformation, detector geometry, cell hemoglobin content, and refractive index on the calculated cell spectra. The origins of the major differences between cell and hemoglobin solution spectra were quantitatively accounted for in terms of differential scatter and absorption flattening, with the latter effect dominating the picture. The relatively low sensitivity of the red blood cell suspension circular dichroism spectrum to hemoglobin conformation is due to the order of magnitude flattening of circular dichroism intensity. The importance of accounting for instrumental light detection geometry and the intense small angle scattering (less than 8 degrees) for a range of particle sizes (0.1-5 mum) is made clear.</abstract><cop>United States</cop><pub>American Chemical Society</pub><pmid>952850</pmid><doi>10.1021/bi00659a030</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0006-2960
ispartof Biochemistry (Easton), 1976-07, Vol.15 (14), p.3138-3145
issn 0006-2960
1520-4995
language eng
recordid cdi_proquest_miscellaneous_83520202
source MEDLINE; American Chemical Society Journals
subjects Circular Dichroism
Erythrocytes
Hemoglobins
Humans
Models, Chemical
Protein Conformation
Scattering, Radiation
Spectrophotometry, Ultraviolet
title Angular scattering analysis of the circular dichroism of biological cells. 2. The red blood cell
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T13%3A33%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Angular%20scattering%20analysis%20of%20the%20circular%20dichroism%20of%20biological%20cells.%202.%20The%20red%20blood%20cell&rft.jtitle=Biochemistry%20(Easton)&rft.au=Gitter-Amir,%20Adina&rft.date=1976-07-13&rft.volume=15&rft.issue=14&rft.spage=3138&rft.epage=3145&rft.pages=3138-3145&rft.issn=0006-2960&rft.eissn=1520-4995&rft_id=info:doi/10.1021/bi00659a030&rft_dat=%3Cproquest_cross%3E83520202%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=83520202&rft_id=info:pmid/952850&rfr_iscdi=true