Rapid determination of theophylline in human plasma by high-pressure liquid chromatography

A rapid, specific, high-pressure liquid chromatographic method for the determination of theophylline in plasma was developed. The procedure is fast enough (21min from receipt of blood to reporting value) to be used for emergency determinations. The sensitivity, precision, and accuracy are sufficient...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of pharmaceutical sciences 1976-06, Vol.65 (6), p.865-868
Hauptverfasser: Weddle, Orville H., Mason, William D.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 868
container_issue 6
container_start_page 865
container_title Journal of pharmaceutical sciences
container_volume 65
creator Weddle, Orville H.
Mason, William D.
description A rapid, specific, high-pressure liquid chromatographic method for the determination of theophylline in plasma was developed. The procedure is fast enough (21min from receipt of blood to reporting value) to be used for emergency determinations. The sensitivity, precision, and accuracy are sufficient for routine monitoring of therapeutic levels in patients. The assay is specific enough to be valid in the presence of caffeine and theobromine. Metabolites of theophylline as well as a number of drugs do not interfere with the assay.
doi_str_mv 10.1002/jps.2600650616
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_83398283</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0022354915408184</els_id><sourcerecordid>83398283</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4266-40df05ef8ff4f6c758544bad5c8350811b85d9a3369920165c6a47263deba97f3</originalsourceid><addsrcrecordid>eNqFkE1v1DAQhi3E17Jw5cTBJ25Z_BE7yREVWgqrAgWExMVy7HHjksSpnUD332OUqogD4jJzmOd9pXkQekrJjhLCXlxOacckIVIQSeUdtKGCkUISWt1FmwywgouyeYgepXRJMkaEeIDuN5w1Fdugb-d68hZbmCEOftSzDyMODs8dhKk79L0fAfsRd8ugRzz1Og0atwfc-YuumCKktETAvb9acovpYhj0HC6iztnH6J7TfYInN3uLvhy__nz0pti_Pzk9erkvTMmkLEpiHRHgaudKJ00lalGWrbbC1FyQmtK2FrbRnMumYYRKYaQuKya5hVY3leNb9HztnWK4WiDNavDJQN_rEcKSVM15U7M8t2i3giaGlCI4NUU_6HhQlKjfLlV2qf64zIFnN81LO4C9xVd5-dys55--h8N_ytTbD5_-qi7WrE8zXN9mdfyuZMUrob6enSj57uMrsj8_U8eZr1cesskfHqJKxsNowPoIZlY2-H998Qu4eaL2</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>83398283</pqid></control><display><type>article</type><title>Rapid determination of theophylline in human plasma by high-pressure liquid chromatography</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><source>Alma/SFX Local Collection</source><creator>Weddle, Orville H. ; Mason, William D.</creator><creatorcontrib>Weddle, Orville H. ; Mason, William D.</creatorcontrib><description>A rapid, specific, high-pressure liquid chromatographic method for the determination of theophylline in plasma was developed. The procedure is fast enough (21min from receipt of blood to reporting value) to be used for emergency determinations. The sensitivity, precision, and accuracy are sufficient for routine monitoring of therapeutic levels in patients. The assay is specific enough to be valid in the presence of caffeine and theobromine. Metabolites of theophylline as well as a number of drugs do not interfere with the assay.</description><identifier>ISSN: 0022-3549</identifier><identifier>EISSN: 1520-6017</identifier><identifier>DOI: 10.1002/jps.2600650616</identifier><identifier>PMID: 932972</identifier><language>eng</language><publisher>Washington: Elsevier Inc</publisher><subject>Chromatography, High Pressure Liquid ; high-pressure liquid chromatographic analysis ; High-pressure liquid chromatography-analysis ; High-pressure liquid chromatography—analysis, theophylline, plasma ; plasma ; Relaxants ; Relaxants, smooth muscle—theophylline, high-pressure liquid chromatographic analysis, plasma ; smooth muscle-theophylline ; theophylline ; Theophylline - blood ; Theophylline-high-pressure liquid chromatographic analysis ; Theophylline—high-pressure liquid chromatographic analysis, plasma</subject><ispartof>Journal of pharmaceutical sciences, 1976-06, Vol.65 (6), p.865-868</ispartof><rights>1976 Wiley-Liss, Inc., A Wiley Company</rights><rights>Copyright © 1976 Wiley‐Liss, Inc., A Wiley Company</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4266-40df05ef8ff4f6c758544bad5c8350811b85d9a3369920165c6a47263deba97f3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fjps.2600650616$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fjps.2600650616$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/932972$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Weddle, Orville H.</creatorcontrib><creatorcontrib>Mason, William D.</creatorcontrib><title>Rapid determination of theophylline in human plasma by high-pressure liquid chromatography</title><title>Journal of pharmaceutical sciences</title><addtitle>J. Pharm. Sci</addtitle><description>A rapid, specific, high-pressure liquid chromatographic method for the determination of theophylline in plasma was developed. The procedure is fast enough (21min from receipt of blood to reporting value) to be used for emergency determinations. The sensitivity, precision, and accuracy are sufficient for routine monitoring of therapeutic levels in patients. The assay is specific enough to be valid in the presence of caffeine and theobromine. Metabolites of theophylline as well as a number of drugs do not interfere with the assay.</description><subject>Chromatography, High Pressure Liquid</subject><subject>high-pressure liquid chromatographic analysis</subject><subject>High-pressure liquid chromatography-analysis</subject><subject>High-pressure liquid chromatography—analysis, theophylline, plasma</subject><subject>plasma</subject><subject>Relaxants</subject><subject>Relaxants, smooth muscle—theophylline, high-pressure liquid chromatographic analysis, plasma</subject><subject>smooth muscle-theophylline</subject><subject>theophylline</subject><subject>Theophylline - blood</subject><subject>Theophylline-high-pressure liquid chromatographic analysis</subject><subject>Theophylline—high-pressure liquid chromatographic analysis, plasma</subject><issn>0022-3549</issn><issn>1520-6017</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1976</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkE1v1DAQhi3E17Jw5cTBJ25Z_BE7yREVWgqrAgWExMVy7HHjksSpnUD332OUqogD4jJzmOd9pXkQekrJjhLCXlxOacckIVIQSeUdtKGCkUISWt1FmwywgouyeYgepXRJMkaEeIDuN5w1Fdugb-d68hZbmCEOftSzDyMODs8dhKk79L0fAfsRd8ugRzz1Og0atwfc-YuumCKktETAvb9acovpYhj0HC6iztnH6J7TfYInN3uLvhy__nz0pti_Pzk9erkvTMmkLEpiHRHgaudKJ00lalGWrbbC1FyQmtK2FrbRnMumYYRKYaQuKya5hVY3leNb9HztnWK4WiDNavDJQN_rEcKSVM15U7M8t2i3giaGlCI4NUU_6HhQlKjfLlV2qf64zIFnN81LO4C9xVd5-dys55--h8N_ytTbD5_-qi7WrE8zXN9mdfyuZMUrob6enSj57uMrsj8_U8eZr1cesskfHqJKxsNowPoIZlY2-H998Qu4eaL2</recordid><startdate>197606</startdate><enddate>197606</enddate><creator>Weddle, Orville H.</creator><creator>Mason, William D.</creator><general>Elsevier Inc</general><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>197606</creationdate><title>Rapid determination of theophylline in human plasma by high-pressure liquid chromatography</title><author>Weddle, Orville H. ; Mason, William D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4266-40df05ef8ff4f6c758544bad5c8350811b85d9a3369920165c6a47263deba97f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1976</creationdate><topic>Chromatography, High Pressure Liquid</topic><topic>high-pressure liquid chromatographic analysis</topic><topic>High-pressure liquid chromatography-analysis</topic><topic>High-pressure liquid chromatography—analysis, theophylline, plasma</topic><topic>plasma</topic><topic>Relaxants</topic><topic>Relaxants, smooth muscle—theophylline, high-pressure liquid chromatographic analysis, plasma</topic><topic>smooth muscle-theophylline</topic><topic>theophylline</topic><topic>Theophylline - blood</topic><topic>Theophylline-high-pressure liquid chromatographic analysis</topic><topic>Theophylline—high-pressure liquid chromatographic analysis, plasma</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Weddle, Orville H.</creatorcontrib><creatorcontrib>Mason, William D.</creatorcontrib><collection>Istex</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of pharmaceutical sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Weddle, Orville H.</au><au>Mason, William D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Rapid determination of theophylline in human plasma by high-pressure liquid chromatography</atitle><jtitle>Journal of pharmaceutical sciences</jtitle><addtitle>J. Pharm. Sci</addtitle><date>1976-06</date><risdate>1976</risdate><volume>65</volume><issue>6</issue><spage>865</spage><epage>868</epage><pages>865-868</pages><issn>0022-3549</issn><eissn>1520-6017</eissn><abstract>A rapid, specific, high-pressure liquid chromatographic method for the determination of theophylline in plasma was developed. The procedure is fast enough (21min from receipt of blood to reporting value) to be used for emergency determinations. The sensitivity, precision, and accuracy are sufficient for routine monitoring of therapeutic levels in patients. The assay is specific enough to be valid in the presence of caffeine and theobromine. Metabolites of theophylline as well as a number of drugs do not interfere with the assay.</abstract><cop>Washington</cop><pub>Elsevier Inc</pub><pmid>932972</pmid><doi>10.1002/jps.2600650616</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0022-3549
ispartof Journal of pharmaceutical sciences, 1976-06, Vol.65 (6), p.865-868
issn 0022-3549
1520-6017
language eng
recordid cdi_proquest_miscellaneous_83398283
source MEDLINE; Wiley Online Library Journals Frontfile Complete; Alma/SFX Local Collection
subjects Chromatography, High Pressure Liquid
high-pressure liquid chromatographic analysis
High-pressure liquid chromatography-analysis
High-pressure liquid chromatography—analysis, theophylline, plasma
plasma
Relaxants
Relaxants, smooth muscle—theophylline, high-pressure liquid chromatographic analysis, plasma
smooth muscle-theophylline
theophylline
Theophylline - blood
Theophylline-high-pressure liquid chromatographic analysis
Theophylline—high-pressure liquid chromatographic analysis, plasma
title Rapid determination of theophylline in human plasma by high-pressure liquid chromatography
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T11%3A28%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Rapid%20determination%20of%20theophylline%20in%20human%20plasma%20by%20high-pressure%20liquid%20chromatography&rft.jtitle=Journal%20of%20pharmaceutical%20sciences&rft.au=Weddle,%20Orville%20H.&rft.date=1976-06&rft.volume=65&rft.issue=6&rft.spage=865&rft.epage=868&rft.pages=865-868&rft.issn=0022-3549&rft.eissn=1520-6017&rft_id=info:doi/10.1002/jps.2600650616&rft_dat=%3Cproquest_cross%3E83398283%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=83398283&rft_id=info:pmid/932972&rft_els_id=S0022354915408184&rfr_iscdi=true