Cardiac imaging using a phased array ultrasound system. II. Clinical technique and application

A new two-dimensional ultrasound imaging system capable of producing high resolution tomographic images of the heart in real time has been developed. This system relies on phased array principles to rapidly steer the ultrasound beam through the structures under investigation. A hand-held linear arra...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Circulation (New York, N.Y.) N.Y.), 1976-02, Vol.53 (2), p.262-267
Hauptverfasser: Kisslo, J, vonRamm, O T, Thurstone, F L
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 267
container_issue 2
container_start_page 262
container_title Circulation (New York, N.Y.)
container_volume 53
creator Kisslo, J
vonRamm, O T
Thurstone, F L
description A new two-dimensional ultrasound imaging system capable of producing high resolution tomographic images of the heart in real time has been developed. This system relies on phased array principles to rapidly steer the ultrasound beam through the structures under investigation. A hand-held linear array of 16 ultrasound transducers with overall dimensions of 14 mm at the site of contanct may be readily manipulated to image various cardiac structures. The resulting images are displayed in a circular sector format, 60 degrees in azimuth and typically 15 cm in range. At his maximum range, image frames consisting of 256 lines are generated at the rate of 20 frames/second. High azimuthal resolution throughout the field of view is assured by a focused transmit beam and by sweeping the focus of the receiver is synchrony with the range of returning echoes. Azimuthal resolution varies from 2 to 5 mm throughout the field of view while range resolution is 1.5 mm. This imaging system has proven particularly useful for the delineation of left ventricular spatial geometry by the identification of endocardium, myocardium, papillary muscles and interventricular septum. High quality images of anterior and posterior mitral leaflets, aortic root and aortic leaflets as well as left atrium and other cardiac structures have been obtained.
doi_str_mv 10.1161/01.cir.53.2.262
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_83238926</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>83238926</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3542-5f377eb1330faf1e6c6e140a0f1d33659df2edbb98ff5d3193981455f76af8df3</originalsourceid><addsrcrecordid>eNpFkMtLxDAQxoMo67p69iTk5K3dJNP0cZTio7AgiF4NaR67kW5bk_aw_71ZdsHLDDP85uObD6F7SlJKc7omNFXOpxxSlrKcXaAl5SxLMg7VJVoSQqqkAMau0U0IP3HMoeALtKAs4wSyJfqupddOKuz2cuv6LZ7DsUo87mQwGkvv5QHP3eRlGOZe43AIk9mnuGlSXHeud0p2eDJq17vf2WAZETmOXVxPbuhv0ZWVXTB3575CXy_Pn_Vbsnl_beqnTaKAZyzhForCtBSAWGmpyVVuaEYksVQD5LzSlhndtlVpLddAK6hKmnFui1zaUltYoceT7uiHaCNMYu-CMl0nezPMQZTAoKxYHsH1CVR-CMEbK0YfX_cHQYk4JioIFXXzITgIJmKi8eLhLD23e6P_-VOE8AdivXHy</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>83238926</pqid></control><display><type>article</type><title>Cardiac imaging using a phased array ultrasound system. II. Clinical technique and application</title><source>MEDLINE</source><source>American Heart Association Journals</source><source>Journals@Ovid Complete</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Kisslo, J ; vonRamm, O T ; Thurstone, F L</creator><creatorcontrib>Kisslo, J ; vonRamm, O T ; Thurstone, F L</creatorcontrib><description>A new two-dimensional ultrasound imaging system capable of producing high resolution tomographic images of the heart in real time has been developed. This system relies on phased array principles to rapidly steer the ultrasound beam through the structures under investigation. A hand-held linear array of 16 ultrasound transducers with overall dimensions of 14 mm at the site of contanct may be readily manipulated to image various cardiac structures. The resulting images are displayed in a circular sector format, 60 degrees in azimuth and typically 15 cm in range. At his maximum range, image frames consisting of 256 lines are generated at the rate of 20 frames/second. High azimuthal resolution throughout the field of view is assured by a focused transmit beam and by sweeping the focus of the receiver is synchrony with the range of returning echoes. Azimuthal resolution varies from 2 to 5 mm throughout the field of view while range resolution is 1.5 mm. This imaging system has proven particularly useful for the delineation of left ventricular spatial geometry by the identification of endocardium, myocardium, papillary muscles and interventricular septum. High quality images of anterior and posterior mitral leaflets, aortic root and aortic leaflets as well as left atrium and other cardiac structures have been obtained.</description><identifier>ISSN: 0009-7322</identifier><identifier>EISSN: 1524-4539</identifier><identifier>DOI: 10.1161/01.cir.53.2.262</identifier><identifier>PMID: 1245034</identifier><language>eng</language><publisher>United States</publisher><subject>Echocardiography - instrumentation ; Echocardiography - methods ; Humans ; Photogrammetry ; Tomography ; Transducers</subject><ispartof>Circulation (New York, N.Y.), 1976-02, Vol.53 (2), p.262-267</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3542-5f377eb1330faf1e6c6e140a0f1d33659df2edbb98ff5d3193981455f76af8df3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,3687,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/1245034$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kisslo, J</creatorcontrib><creatorcontrib>vonRamm, O T</creatorcontrib><creatorcontrib>Thurstone, F L</creatorcontrib><title>Cardiac imaging using a phased array ultrasound system. II. Clinical technique and application</title><title>Circulation (New York, N.Y.)</title><addtitle>Circulation</addtitle><description>A new two-dimensional ultrasound imaging system capable of producing high resolution tomographic images of the heart in real time has been developed. This system relies on phased array principles to rapidly steer the ultrasound beam through the structures under investigation. A hand-held linear array of 16 ultrasound transducers with overall dimensions of 14 mm at the site of contanct may be readily manipulated to image various cardiac structures. The resulting images are displayed in a circular sector format, 60 degrees in azimuth and typically 15 cm in range. At his maximum range, image frames consisting of 256 lines are generated at the rate of 20 frames/second. High azimuthal resolution throughout the field of view is assured by a focused transmit beam and by sweeping the focus of the receiver is synchrony with the range of returning echoes. Azimuthal resolution varies from 2 to 5 mm throughout the field of view while range resolution is 1.5 mm. This imaging system has proven particularly useful for the delineation of left ventricular spatial geometry by the identification of endocardium, myocardium, papillary muscles and interventricular septum. High quality images of anterior and posterior mitral leaflets, aortic root and aortic leaflets as well as left atrium and other cardiac structures have been obtained.</description><subject>Echocardiography - instrumentation</subject><subject>Echocardiography - methods</subject><subject>Humans</subject><subject>Photogrammetry</subject><subject>Tomography</subject><subject>Transducers</subject><issn>0009-7322</issn><issn>1524-4539</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1976</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkMtLxDAQxoMo67p69iTk5K3dJNP0cZTio7AgiF4NaR67kW5bk_aw_71ZdsHLDDP85uObD6F7SlJKc7omNFXOpxxSlrKcXaAl5SxLMg7VJVoSQqqkAMau0U0IP3HMoeALtKAs4wSyJfqupddOKuz2cuv6LZ7DsUo87mQwGkvv5QHP3eRlGOZe43AIk9mnuGlSXHeud0p2eDJq17vf2WAZETmOXVxPbuhv0ZWVXTB3575CXy_Pn_Vbsnl_beqnTaKAZyzhForCtBSAWGmpyVVuaEYksVQD5LzSlhndtlVpLddAK6hKmnFui1zaUltYoceT7uiHaCNMYu-CMl0nezPMQZTAoKxYHsH1CVR-CMEbK0YfX_cHQYk4JioIFXXzITgIJmKi8eLhLD23e6P_-VOE8AdivXHy</recordid><startdate>197602</startdate><enddate>197602</enddate><creator>Kisslo, J</creator><creator>vonRamm, O T</creator><creator>Thurstone, F L</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>197602</creationdate><title>Cardiac imaging using a phased array ultrasound system. II. Clinical technique and application</title><author>Kisslo, J ; vonRamm, O T ; Thurstone, F L</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3542-5f377eb1330faf1e6c6e140a0f1d33659df2edbb98ff5d3193981455f76af8df3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1976</creationdate><topic>Echocardiography - instrumentation</topic><topic>Echocardiography - methods</topic><topic>Humans</topic><topic>Photogrammetry</topic><topic>Tomography</topic><topic>Transducers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kisslo, J</creatorcontrib><creatorcontrib>vonRamm, O T</creatorcontrib><creatorcontrib>Thurstone, F L</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Circulation (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kisslo, J</au><au>vonRamm, O T</au><au>Thurstone, F L</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Cardiac imaging using a phased array ultrasound system. II. Clinical technique and application</atitle><jtitle>Circulation (New York, N.Y.)</jtitle><addtitle>Circulation</addtitle><date>1976-02</date><risdate>1976</risdate><volume>53</volume><issue>2</issue><spage>262</spage><epage>267</epage><pages>262-267</pages><issn>0009-7322</issn><eissn>1524-4539</eissn><abstract>A new two-dimensional ultrasound imaging system capable of producing high resolution tomographic images of the heart in real time has been developed. This system relies on phased array principles to rapidly steer the ultrasound beam through the structures under investigation. A hand-held linear array of 16 ultrasound transducers with overall dimensions of 14 mm at the site of contanct may be readily manipulated to image various cardiac structures. The resulting images are displayed in a circular sector format, 60 degrees in azimuth and typically 15 cm in range. At his maximum range, image frames consisting of 256 lines are generated at the rate of 20 frames/second. High azimuthal resolution throughout the field of view is assured by a focused transmit beam and by sweeping the focus of the receiver is synchrony with the range of returning echoes. Azimuthal resolution varies from 2 to 5 mm throughout the field of view while range resolution is 1.5 mm. This imaging system has proven particularly useful for the delineation of left ventricular spatial geometry by the identification of endocardium, myocardium, papillary muscles and interventricular septum. High quality images of anterior and posterior mitral leaflets, aortic root and aortic leaflets as well as left atrium and other cardiac structures have been obtained.</abstract><cop>United States</cop><pmid>1245034</pmid><doi>10.1161/01.cir.53.2.262</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0009-7322
ispartof Circulation (New York, N.Y.), 1976-02, Vol.53 (2), p.262-267
issn 0009-7322
1524-4539
language eng
recordid cdi_proquest_miscellaneous_83238926
source MEDLINE; American Heart Association Journals; Journals@Ovid Complete; EZB-FREE-00999 freely available EZB journals
subjects Echocardiography - instrumentation
Echocardiography - methods
Humans
Photogrammetry
Tomography
Transducers
title Cardiac imaging using a phased array ultrasound system. II. Clinical technique and application
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T11%3A52%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Cardiac%20imaging%20using%20a%20phased%20array%20ultrasound%20system.%20II.%20Clinical%20technique%20and%20application&rft.jtitle=Circulation%20(New%20York,%20N.Y.)&rft.au=Kisslo,%20J&rft.date=1976-02&rft.volume=53&rft.issue=2&rft.spage=262&rft.epage=267&rft.pages=262-267&rft.issn=0009-7322&rft.eissn=1524-4539&rft_id=info:doi/10.1161/01.cir.53.2.262&rft_dat=%3Cproquest_cross%3E83238926%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=83238926&rft_id=info:pmid/1245034&rfr_iscdi=true