Porohyperelastic Finite Element Modeling of Abdominal Aortic Aneurysms

Abdominal aortic aneurysm (AAA) is the gradual weakening and dilation of the infrarenal aorta. This disease is progressive, asymptomatic, and can eventually lead to rupture-a catastrophic event leading to massive internal bleeding and possibly death. The mechanical environment present in AAA is curr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of biomechanical engineering 2010-10, Vol.132 (10), p.104502 (8)-104502 (8)
Hauptverfasser: Ayyalasomayajula, Avinash, Vande Geest, Jonathan P, Simon, Bruce R
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 104502 (8)
container_issue 10
container_start_page 104502 (8)
container_title Journal of biomechanical engineering
container_volume 132
creator Ayyalasomayajula, Avinash
Vande Geest, Jonathan P
Simon, Bruce R
description Abdominal aortic aneurysm (AAA) is the gradual weakening and dilation of the infrarenal aorta. This disease is progressive, asymptomatic, and can eventually lead to rupture-a catastrophic event leading to massive internal bleeding and possibly death. The mechanical environment present in AAA is currently thought to be important in disease initiation, progression, and diagnosis. In this study, we utilize porohyperelastic (PHE) finite element models (FEMs) to investigate how such modeling can be used to better understand the local biomechanical environment in AAA. A 3D hypothetical AAA was constructed with a preferential anterior bulge assuming both the intraluminal thrombus (ILT) and the AAA wall act as porous materials. A parametric study was performed to investigate how physiologically meaningful variations in AAA wall and ILT hydraulic permeabilities affect luminal interstitial fluid velocities and wall stresses within an AAA. A corresponding hyperelastic (HE) simulation was also run in order to be able to compare stress values between PHE and HE simulations. The effect of AAA size on local interstitial fluid velocity was also investigated by simulating maximum diameters (5.5 cm, 4.5 cm, and 3.5 cm) at the baseline values of ILT and AAA wall permeability. Finally, a cyclic PHE simulation was utilized to study the variation in local fluid velocities as a result of a physiologic pulsatile blood pressure. While the ILT hydraulic permeability was found to have minimal affect on interstitial velocities, our simulations demonstrated a 28% increase and a 20% decrease in luminal interstitial fluid velocity as a result of a 1 standard deviation increase and decrease in AAA wall hydraulic permeability, respectively. Peak interstitial velocities in all simulations occurred on the luminal surface adjacent to the region of maximum diameter. These values increased with increasing AAA size. PHE simulations resulted in 19.4%, 40.1%, and 81.0% increases in peak maximum principal wall stresses in comparison to HE simulations for maximum diameters of 35 mm, 45 mm, and 55 mm, respectively. The pulsatile AAA PHE FEM demonstrated a complex interstitial fluid velocity field the direction of which alternated in to and out of the luminal layer of the ILT. The biomechanical environment within both the aneurysmal wall and the ILT is involved in AAA pathogenesis and rupture. Assuming these tissues to be porohyperelastic materials may provide additional insight into the complex soli
doi_str_mv 10.1115/1.4002370YouarenotloggedintotheASMEDigitalLibrary.
format Article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_miscellaneous_831145891</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>831145891</sourcerecordid><originalsourceid>FETCH-proquest_miscellaneous_8311458913</originalsourceid><addsrcrecordid>eNqNyr1Ow0AMAOAbQKL8vMNtTA02SdXAFkEiBiohwcJUXRs3NXLO5XwZ8vYIiQdg-pbPuUeEAhFXd1hUAPflGj51ComiZtFhoJ5j1nyk5n3TPvPAOcgr71JIc3HmFoBVvYR1iRfu0uwLALGuYOG6N016nE-USIJl3vuOI2fyrdBIMfuN9iQcB68H3-x6HTkG8Y2m39tEmtJso12780MQo5s_r9xt1348vSxPSb8nsrwd2fYkEiLpZNu6RKxW9QOW_58_t-RSMA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>831145891</pqid></control><display><type>article</type><title>Porohyperelastic Finite Element Modeling of Abdominal Aortic Aneurysms</title><source>ASME Transactions Journals (Current)</source><creator>Ayyalasomayajula, Avinash ; Vande Geest, Jonathan P ; Simon, Bruce R</creator><creatorcontrib>Ayyalasomayajula, Avinash ; Vande Geest, Jonathan P ; Simon, Bruce R</creatorcontrib><description>Abdominal aortic aneurysm (AAA) is the gradual weakening and dilation of the infrarenal aorta. This disease is progressive, asymptomatic, and can eventually lead to rupture-a catastrophic event leading to massive internal bleeding and possibly death. The mechanical environment present in AAA is currently thought to be important in disease initiation, progression, and diagnosis. In this study, we utilize porohyperelastic (PHE) finite element models (FEMs) to investigate how such modeling can be used to better understand the local biomechanical environment in AAA. A 3D hypothetical AAA was constructed with a preferential anterior bulge assuming both the intraluminal thrombus (ILT) and the AAA wall act as porous materials. A parametric study was performed to investigate how physiologically meaningful variations in AAA wall and ILT hydraulic permeabilities affect luminal interstitial fluid velocities and wall stresses within an AAA. A corresponding hyperelastic (HE) simulation was also run in order to be able to compare stress values between PHE and HE simulations. The effect of AAA size on local interstitial fluid velocity was also investigated by simulating maximum diameters (5.5 cm, 4.5 cm, and 3.5 cm) at the baseline values of ILT and AAA wall permeability. Finally, a cyclic PHE simulation was utilized to study the variation in local fluid velocities as a result of a physiologic pulsatile blood pressure. While the ILT hydraulic permeability was found to have minimal affect on interstitial velocities, our simulations demonstrated a 28% increase and a 20% decrease in luminal interstitial fluid velocity as a result of a 1 standard deviation increase and decrease in AAA wall hydraulic permeability, respectively. Peak interstitial velocities in all simulations occurred on the luminal surface adjacent to the region of maximum diameter. These values increased with increasing AAA size. PHE simulations resulted in 19.4%, 40.1%, and 81.0% increases in peak maximum principal wall stresses in comparison to HE simulations for maximum diameters of 35 mm, 45 mm, and 55 mm, respectively. The pulsatile AAA PHE FEM demonstrated a complex interstitial fluid velocity field the direction of which alternated in to and out of the luminal layer of the ILT. The biomechanical environment within both the aneurysmal wall and the ILT is involved in AAA pathogenesis and rupture. Assuming these tissues to be porohyperelastic materials may provide additional insight into the complex solid and fluid forces acting on the cells responsible for aneurysmal remodeling and weakening.</description><identifier>ISSN: 0148-0731</identifier><identifier>DOI: 10.1115/1.4002370YouarenotloggedintotheASMEDigitalLibrary.</identifier><language>eng</language><ispartof>Journal of biomechanical engineering, 2010-10, Vol.132 (10), p.104502 (8)-104502 (8)</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27929,27930</link.rule.ids></links><search><creatorcontrib>Ayyalasomayajula, Avinash</creatorcontrib><creatorcontrib>Vande Geest, Jonathan P</creatorcontrib><creatorcontrib>Simon, Bruce R</creatorcontrib><title>Porohyperelastic Finite Element Modeling of Abdominal Aortic Aneurysms</title><title>Journal of biomechanical engineering</title><description>Abdominal aortic aneurysm (AAA) is the gradual weakening and dilation of the infrarenal aorta. This disease is progressive, asymptomatic, and can eventually lead to rupture-a catastrophic event leading to massive internal bleeding and possibly death. The mechanical environment present in AAA is currently thought to be important in disease initiation, progression, and diagnosis. In this study, we utilize porohyperelastic (PHE) finite element models (FEMs) to investigate how such modeling can be used to better understand the local biomechanical environment in AAA. A 3D hypothetical AAA was constructed with a preferential anterior bulge assuming both the intraluminal thrombus (ILT) and the AAA wall act as porous materials. A parametric study was performed to investigate how physiologically meaningful variations in AAA wall and ILT hydraulic permeabilities affect luminal interstitial fluid velocities and wall stresses within an AAA. A corresponding hyperelastic (HE) simulation was also run in order to be able to compare stress values between PHE and HE simulations. The effect of AAA size on local interstitial fluid velocity was also investigated by simulating maximum diameters (5.5 cm, 4.5 cm, and 3.5 cm) at the baseline values of ILT and AAA wall permeability. Finally, a cyclic PHE simulation was utilized to study the variation in local fluid velocities as a result of a physiologic pulsatile blood pressure. While the ILT hydraulic permeability was found to have minimal affect on interstitial velocities, our simulations demonstrated a 28% increase and a 20% decrease in luminal interstitial fluid velocity as a result of a 1 standard deviation increase and decrease in AAA wall hydraulic permeability, respectively. Peak interstitial velocities in all simulations occurred on the luminal surface adjacent to the region of maximum diameter. These values increased with increasing AAA size. PHE simulations resulted in 19.4%, 40.1%, and 81.0% increases in peak maximum principal wall stresses in comparison to HE simulations for maximum diameters of 35 mm, 45 mm, and 55 mm, respectively. The pulsatile AAA PHE FEM demonstrated a complex interstitial fluid velocity field the direction of which alternated in to and out of the luminal layer of the ILT. The biomechanical environment within both the aneurysmal wall and the ILT is involved in AAA pathogenesis and rupture. Assuming these tissues to be porohyperelastic materials may provide additional insight into the complex solid and fluid forces acting on the cells responsible for aneurysmal remodeling and weakening.</description><issn>0148-0731</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNqNyr1Ow0AMAOAbQKL8vMNtTA02SdXAFkEiBiohwcJUXRs3NXLO5XwZ8vYIiQdg-pbPuUeEAhFXd1hUAPflGj51ComiZtFhoJ5j1nyk5n3TPvPAOcgr71JIc3HmFoBVvYR1iRfu0uwLALGuYOG6N016nE-USIJl3vuOI2fyrdBIMfuN9iQcB68H3-x6HTkG8Y2m39tEmtJso12780MQo5s_r9xt1348vSxPSb8nsrwd2fYkEiLpZNu6RKxW9QOW_58_t-RSMA</recordid><startdate>20101001</startdate><enddate>20101001</enddate><creator>Ayyalasomayajula, Avinash</creator><creator>Vande Geest, Jonathan P</creator><creator>Simon, Bruce R</creator><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope></search><sort><creationdate>20101001</creationdate><title>Porohyperelastic Finite Element Modeling of Abdominal Aortic Aneurysms</title><author>Ayyalasomayajula, Avinash ; Vande Geest, Jonathan P ; Simon, Bruce R</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_miscellaneous_8311458913</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ayyalasomayajula, Avinash</creatorcontrib><creatorcontrib>Vande Geest, Jonathan P</creatorcontrib><creatorcontrib>Simon, Bruce R</creatorcontrib><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><jtitle>Journal of biomechanical engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ayyalasomayajula, Avinash</au><au>Vande Geest, Jonathan P</au><au>Simon, Bruce R</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Porohyperelastic Finite Element Modeling of Abdominal Aortic Aneurysms</atitle><jtitle>Journal of biomechanical engineering</jtitle><date>2010-10-01</date><risdate>2010</risdate><volume>132</volume><issue>10</issue><spage>104502 (8)</spage><epage>104502 (8)</epage><pages>104502 (8)-104502 (8)</pages><issn>0148-0731</issn><abstract>Abdominal aortic aneurysm (AAA) is the gradual weakening and dilation of the infrarenal aorta. This disease is progressive, asymptomatic, and can eventually lead to rupture-a catastrophic event leading to massive internal bleeding and possibly death. The mechanical environment present in AAA is currently thought to be important in disease initiation, progression, and diagnosis. In this study, we utilize porohyperelastic (PHE) finite element models (FEMs) to investigate how such modeling can be used to better understand the local biomechanical environment in AAA. A 3D hypothetical AAA was constructed with a preferential anterior bulge assuming both the intraluminal thrombus (ILT) and the AAA wall act as porous materials. A parametric study was performed to investigate how physiologically meaningful variations in AAA wall and ILT hydraulic permeabilities affect luminal interstitial fluid velocities and wall stresses within an AAA. A corresponding hyperelastic (HE) simulation was also run in order to be able to compare stress values between PHE and HE simulations. The effect of AAA size on local interstitial fluid velocity was also investigated by simulating maximum diameters (5.5 cm, 4.5 cm, and 3.5 cm) at the baseline values of ILT and AAA wall permeability. Finally, a cyclic PHE simulation was utilized to study the variation in local fluid velocities as a result of a physiologic pulsatile blood pressure. While the ILT hydraulic permeability was found to have minimal affect on interstitial velocities, our simulations demonstrated a 28% increase and a 20% decrease in luminal interstitial fluid velocity as a result of a 1 standard deviation increase and decrease in AAA wall hydraulic permeability, respectively. Peak interstitial velocities in all simulations occurred on the luminal surface adjacent to the region of maximum diameter. These values increased with increasing AAA size. PHE simulations resulted in 19.4%, 40.1%, and 81.0% increases in peak maximum principal wall stresses in comparison to HE simulations for maximum diameters of 35 mm, 45 mm, and 55 mm, respectively. The pulsatile AAA PHE FEM demonstrated a complex interstitial fluid velocity field the direction of which alternated in to and out of the luminal layer of the ILT. The biomechanical environment within both the aneurysmal wall and the ILT is involved in AAA pathogenesis and rupture. Assuming these tissues to be porohyperelastic materials may provide additional insight into the complex solid and fluid forces acting on the cells responsible for aneurysmal remodeling and weakening.</abstract><doi>10.1115/1.4002370YouarenotloggedintotheASMEDigitalLibrary.</doi></addata></record>
fulltext fulltext
identifier ISSN: 0148-0731
ispartof Journal of biomechanical engineering, 2010-10, Vol.132 (10), p.104502 (8)-104502 (8)
issn 0148-0731
language eng
recordid cdi_proquest_miscellaneous_831145891
source ASME Transactions Journals (Current)
title Porohyperelastic Finite Element Modeling of Abdominal Aortic Aneurysms
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-14T10%3A05%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Porohyperelastic%20Finite%20Element%20Modeling%20of%20Abdominal%20Aortic%20Aneurysms&rft.jtitle=Journal%20of%20biomechanical%20engineering&rft.au=Ayyalasomayajula,%20Avinash&rft.date=2010-10-01&rft.volume=132&rft.issue=10&rft.spage=104502%20(8)&rft.epage=104502%20(8)&rft.pages=104502%20(8)-104502%20(8)&rft.issn=0148-0731&rft_id=info:doi/10.1115/1.4002370YouarenotloggedintotheASMEDigitalLibrary.&rft_dat=%3Cproquest%3E831145891%3C/proquest%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=831145891&rft_id=info:pmid/&rfr_iscdi=true