Oscillo-evaporator

A simple evaporator for flasks under reduced pressure was designed which needed no rotating joint. It moves in a rotary oscillation at an angle of about 110°, and an outlet is connected with a condenser by a rubber tube. The angle of rotation can be increased by combining the oscillator with a pair...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:YAKUGAKU ZASSHI 1963/06/25, Vol.83(6), pp.653-654
1. Verfasser: Momose, Tsutomu
Format: Artikel
Sprache:jpn
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 654
container_issue 6
container_start_page 653
container_title YAKUGAKU ZASSHI
container_volume 83
creator Momose, Tsutomu
description A simple evaporator for flasks under reduced pressure was designed which needed no rotating joint. It moves in a rotary oscillation at an angle of about 110°, and an outlet is connected with a condenser by a rubber tube. The angle of rotation can be increased by combining the oscillator with a pair of gears, but the simplest one may be useful for usual purpose of evaporation with minimum foaming or bumping in the flasks when it is oscillated about 150 times per minute.
doi_str_mv 10.1248/yakushi1947.83.6_653
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_83051144</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>83051144</sourcerecordid><originalsourceid>FETCH-LOGICAL-j188t-c8f64582f1dc799eaf12c5cc0f75ed9754055355772bb23646d7b2b121a13b123</originalsourceid><addsrcrecordid>eNpN0DFPwzAQBWALgWhVujAjRrYUn89nOyOqoCBV6gKz5TgOTUmbYidI_fdEaqm44W759KR7jN0Bn4GQ5vHgvvq0riGXemZwpqwivGBjQKkzEgiXbMw5QqZyjiM2TakuOBfDEJhrNgLMkXLSY3a7Sr5umjYLP27fRte18YZdVa5JYXq6E_bx8vw-f82Wq8Xb_GmZbcCYLvOmUpKMqKD0Os-Dq0B48p5XmkKZa5KcCIm0FkUhUElV6kIUIMABDgcn7OGYu4_tdx9SZ7d18qFp3C60fbIGOQFIOcD7E-yLbSjtPtZbFw_274sBLI5gkzr3Gc7Axa72TbD_2hpSrTquobKz8GsXbdjhL96rY6s</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>83051144</pqid></control><display><type>article</type><title>Oscillo-evaporator</title><source>J-STAGE Free</source><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Momose, Tsutomu</creator><creatorcontrib>Momose, Tsutomu</creatorcontrib><description>A simple evaporator for flasks under reduced pressure was designed which needed no rotating joint. It moves in a rotary oscillation at an angle of about 110°, and an outlet is connected with a condenser by a rubber tube. The angle of rotation can be increased by combining the oscillator with a pair of gears, but the simplest one may be useful for usual purpose of evaporation with minimum foaming or bumping in the flasks when it is oscillated about 150 times per minute.</description><identifier>ISSN: 0031-6903</identifier><identifier>EISSN: 1347-5231</identifier><identifier>DOI: 10.1248/yakushi1947.83.6_653</identifier><identifier>PMID: 13935957</identifier><language>jpn</language><publisher>Japan: The Pharmaceutical Society of Japan</publisher><subject>Chemistry, Pharmaceutical ; Old Medline ; Pharmacy</subject><ispartof>YAKUGAKU ZASSHI, 1963/06/25, Vol.83(6), pp.653-654</ispartof><rights>by the PHARMACEUTICAL SOCIETY OF JAPAN</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,1883,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/13935957$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Momose, Tsutomu</creatorcontrib><title>Oscillo-evaporator</title><title>YAKUGAKU ZASSHI</title><addtitle>YAKUGAKU ZASSHI</addtitle><description>A simple evaporator for flasks under reduced pressure was designed which needed no rotating joint. It moves in a rotary oscillation at an angle of about 110°, and an outlet is connected with a condenser by a rubber tube. The angle of rotation can be increased by combining the oscillator with a pair of gears, but the simplest one may be useful for usual purpose of evaporation with minimum foaming or bumping in the flasks when it is oscillated about 150 times per minute.</description><subject>Chemistry, Pharmaceutical</subject><subject>Old Medline</subject><subject>Pharmacy</subject><issn>0031-6903</issn><issn>1347-5231</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1963</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpN0DFPwzAQBWALgWhVujAjRrYUn89nOyOqoCBV6gKz5TgOTUmbYidI_fdEaqm44W759KR7jN0Bn4GQ5vHgvvq0riGXemZwpqwivGBjQKkzEgiXbMw5QqZyjiM2TakuOBfDEJhrNgLMkXLSY3a7Sr5umjYLP27fRte18YZdVa5JYXq6E_bx8vw-f82Wq8Xb_GmZbcCYLvOmUpKMqKD0Os-Dq0B48p5XmkKZa5KcCIm0FkUhUElV6kIUIMABDgcn7OGYu4_tdx9SZ7d18qFp3C60fbIGOQFIOcD7E-yLbSjtPtZbFw_274sBLI5gkzr3Gc7Axa72TbD_2hpSrTquobKz8GsXbdjhL96rY6s</recordid><startdate>19630601</startdate><enddate>19630601</enddate><creator>Momose, Tsutomu</creator><general>The Pharmaceutical Society of Japan</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>19630601</creationdate><title>Oscillo-evaporator</title><author>Momose, Tsutomu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-j188t-c8f64582f1dc799eaf12c5cc0f75ed9754055355772bb23646d7b2b121a13b123</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>jpn</language><creationdate>1963</creationdate><topic>Chemistry, Pharmaceutical</topic><topic>Old Medline</topic><topic>Pharmacy</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Momose, Tsutomu</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>YAKUGAKU ZASSHI</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Momose, Tsutomu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Oscillo-evaporator</atitle><jtitle>YAKUGAKU ZASSHI</jtitle><addtitle>YAKUGAKU ZASSHI</addtitle><date>1963-06-01</date><risdate>1963</risdate><volume>83</volume><issue>6</issue><spage>653</spage><epage>654</epage><pages>653-654</pages><issn>0031-6903</issn><eissn>1347-5231</eissn><abstract>A simple evaporator for flasks under reduced pressure was designed which needed no rotating joint. It moves in a rotary oscillation at an angle of about 110°, and an outlet is connected with a condenser by a rubber tube. The angle of rotation can be increased by combining the oscillator with a pair of gears, but the simplest one may be useful for usual purpose of evaporation with minimum foaming or bumping in the flasks when it is oscillated about 150 times per minute.</abstract><cop>Japan</cop><pub>The Pharmaceutical Society of Japan</pub><pmid>13935957</pmid><doi>10.1248/yakushi1947.83.6_653</doi><tpages>2</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0031-6903
ispartof YAKUGAKU ZASSHI, 1963/06/25, Vol.83(6), pp.653-654
issn 0031-6903
1347-5231
language jpn
recordid cdi_proquest_miscellaneous_83051144
source J-STAGE Free; MEDLINE; Alma/SFX Local Collection
subjects Chemistry, Pharmaceutical
Old Medline
Pharmacy
title Oscillo-evaporator
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T12%3A10%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Oscillo-evaporator&rft.jtitle=YAKUGAKU%20ZASSHI&rft.au=Momose,%20Tsutomu&rft.date=1963-06-01&rft.volume=83&rft.issue=6&rft.spage=653&rft.epage=654&rft.pages=653-654&rft.issn=0031-6903&rft.eissn=1347-5231&rft_id=info:doi/10.1248/yakushi1947.83.6_653&rft_dat=%3Cproquest_pubme%3E83051144%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=83051144&rft_id=info:pmid/13935957&rfr_iscdi=true