Ventricular Nonmixing as a Source of Error in the Estimation of Ventricular Volume by the Indicator-Dilution Technic
1. In the anesthetized dog, end-diastolic, end-systolic and stroke volumes for the left ventricle have been calculated according to the method of Holt from dilution curves recorded at the aortic root. For heart rates of less than 120 beats per minute, the catheterdensitometer systems used gave 90 to...
Gespeichert in:
Veröffentlicht in: | Circulation research 1960-09, Vol.8 (5), p.989-998 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 998 |
---|---|
container_issue | 5 |
container_start_page | 989 |
container_title | Circulation research |
container_volume | 8 |
creator | Swan, H. J C Beck, Walter |
description | 1. In the anesthetized dog, end-diastolic, end-systolic and stroke volumes for the left ventricle have been calculated according to the method of Holt from dilution curves recorded at the aortic root. For heart rates of less than 120 beats per minute, the catheterdensitometer systems used gave 90 to 95 per cent of the true concentration in the aortic root at the end of diastole.2. Average volumes of 2.96, 1.63 and 1.33 ml./Kg. of body weight were calculated for each of these parameters. The interindividual and intraindividual variations about these means amounted to ± 30 to 50 per cent.3. In approximately 15 per cent of the dilution curves the concentration of dye in the aortic root during early systole (phase of maximal ejection) showed a transient, markedly low value compared with that of the end of diastole. This can be explained only on the basis of the preferential ejection from the heart in early systole of the undyed, newly entering blood from the left atrium, which had mixed poorly with the residual volume of the ventricle. Qualitative inspection of cineangiograms confirmed this impression and demonstrated that a residuum of contrast medium failed to mix with the incoming blood from the left atrium.4. In addition, there is evidence for the possibility of overestiination of stroke volumes from dilution curves recorded immediately proximal to the injection chamber.5. Incomplete mixing of the left artial blood with the residual volume of the ventricle precludes accurate quantitation of the changes of volume in the ventricle by the simple formulas proposed by previous authors. This phenomenon may serve to explain the considerable variability that is found in the present study and in the literature. |
doi_str_mv | 10.1161/01.RES.8.5.989 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_82571128</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>82571128</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4135-5500fdadab40e73073010ffeef48d992bd84f4b8eb50421110a034cd8df25cf23</originalsourceid><addsrcrecordid>eNpNkc9rFTEQgIMo9rV69Sg5edvtTH68zR6lPrVQFGztNWSziS-6u6lJltr_3rTvgUKGMMw3A_MNIW8QWsQtngO233bXrWpl26v-GdmgZKIRssPnZAMAfdNxDifkNOefACg461-SE-RdJxhsN6TcuqWkYNfJJPolLnP4E5Yf1GRq6HVck3U0erpLKSYaFlr2ju5yCbMpIS6Ppf_7b-O0zo4OD0_c5TIGa0pMzYcwrU_8jbP7JdhX5IU3U3avj_8Z-f5xd3Pxubn6-uny4v1VYwVy2UgJ4EczmkGA6zjUh-C9c16ose_ZMCrhxaDcIEEwRAQDXNhRjZ5J6xk_I-8Oc-9S_L26XPQcsnXTZBYX16wVq56QqQq2B9CmmHNyXt-lumN60Aj60bMG1NWzVlrq6rk2vD1OXofZjf_wo9gKiANwH6fiUv41rfcu6b0zU9nrehioy7AG-229Uc2aGij5X8vJiV4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>82571128</pqid></control><display><type>article</type><title>Ventricular Nonmixing as a Source of Error in the Estimation of Ventricular Volume by the Indicator-Dilution Technic</title><source>MEDLINE</source><source>American Heart Association Journals</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Journals@Ovid Complete</source><creator>Swan, H. J C ; Beck, Walter</creator><creatorcontrib>Swan, H. J C ; Beck, Walter</creatorcontrib><description>1. In the anesthetized dog, end-diastolic, end-systolic and stroke volumes for the left ventricle have been calculated according to the method of Holt from dilution curves recorded at the aortic root. For heart rates of less than 120 beats per minute, the catheterdensitometer systems used gave 90 to 95 per cent of the true concentration in the aortic root at the end of diastole.2. Average volumes of 2.96, 1.63 and 1.33 ml./Kg. of body weight were calculated for each of these parameters. The interindividual and intraindividual variations about these means amounted to ± 30 to 50 per cent.3. In approximately 15 per cent of the dilution curves the concentration of dye in the aortic root during early systole (phase of maximal ejection) showed a transient, markedly low value compared with that of the end of diastole. This can be explained only on the basis of the preferential ejection from the heart in early systole of the undyed, newly entering blood from the left atrium, which had mixed poorly with the residual volume of the ventricle. Qualitative inspection of cineangiograms confirmed this impression and demonstrated that a residuum of contrast medium failed to mix with the incoming blood from the left atrium.4. In addition, there is evidence for the possibility of overestiination of stroke volumes from dilution curves recorded immediately proximal to the injection chamber.5. Incomplete mixing of the left artial blood with the residual volume of the ventricle precludes accurate quantitation of the changes of volume in the ventricle by the simple formulas proposed by previous authors. This phenomenon may serve to explain the considerable variability that is found in the present study and in the literature.</description><identifier>ISSN: 0009-7330</identifier><identifier>EISSN: 1524-4571</identifier><identifier>DOI: 10.1161/01.RES.8.5.989</identifier><identifier>PMID: 13774206</identifier><language>eng</language><publisher>United States: American Heart Association, Inc</publisher><subject>Heart - physiology ; Heart Ventricles ; Humans ; Indicator Dilution Techniques ; Old Medline ; Regression Analysis</subject><ispartof>Circulation research, 1960-09, Vol.8 (5), p.989-998</ispartof><rights>1960 American Heart Association, Inc.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4135-5500fdadab40e73073010ffeef48d992bd84f4b8eb50421110a034cd8df25cf23</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,3674,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/13774206$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Swan, H. J C</creatorcontrib><creatorcontrib>Beck, Walter</creatorcontrib><title>Ventricular Nonmixing as a Source of Error in the Estimation of Ventricular Volume by the Indicator-Dilution Technic</title><title>Circulation research</title><addtitle>Circ Res</addtitle><description>1. In the anesthetized dog, end-diastolic, end-systolic and stroke volumes for the left ventricle have been calculated according to the method of Holt from dilution curves recorded at the aortic root. For heart rates of less than 120 beats per minute, the catheterdensitometer systems used gave 90 to 95 per cent of the true concentration in the aortic root at the end of diastole.2. Average volumes of 2.96, 1.63 and 1.33 ml./Kg. of body weight were calculated for each of these parameters. The interindividual and intraindividual variations about these means amounted to ± 30 to 50 per cent.3. In approximately 15 per cent of the dilution curves the concentration of dye in the aortic root during early systole (phase of maximal ejection) showed a transient, markedly low value compared with that of the end of diastole. This can be explained only on the basis of the preferential ejection from the heart in early systole of the undyed, newly entering blood from the left atrium, which had mixed poorly with the residual volume of the ventricle. Qualitative inspection of cineangiograms confirmed this impression and demonstrated that a residuum of contrast medium failed to mix with the incoming blood from the left atrium.4. In addition, there is evidence for the possibility of overestiination of stroke volumes from dilution curves recorded immediately proximal to the injection chamber.5. Incomplete mixing of the left artial blood with the residual volume of the ventricle precludes accurate quantitation of the changes of volume in the ventricle by the simple formulas proposed by previous authors. This phenomenon may serve to explain the considerable variability that is found in the present study and in the literature.</description><subject>Heart - physiology</subject><subject>Heart Ventricles</subject><subject>Humans</subject><subject>Indicator Dilution Techniques</subject><subject>Old Medline</subject><subject>Regression Analysis</subject><issn>0009-7330</issn><issn>1524-4571</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1960</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNkc9rFTEQgIMo9rV69Sg5edvtTH68zR6lPrVQFGztNWSziS-6u6lJltr_3rTvgUKGMMw3A_MNIW8QWsQtngO233bXrWpl26v-GdmgZKIRssPnZAMAfdNxDifkNOefACg461-SE-RdJxhsN6TcuqWkYNfJJPolLnP4E5Yf1GRq6HVck3U0erpLKSYaFlr2ju5yCbMpIS6Ppf_7b-O0zo4OD0_c5TIGa0pMzYcwrU_8jbP7JdhX5IU3U3avj_8Z-f5xd3Pxubn6-uny4v1VYwVy2UgJ4EczmkGA6zjUh-C9c16ose_ZMCrhxaDcIEEwRAQDXNhRjZ5J6xk_I-8Oc-9S_L26XPQcsnXTZBYX16wVq56QqQq2B9CmmHNyXt-lumN60Aj60bMG1NWzVlrq6rk2vD1OXofZjf_wo9gKiANwH6fiUv41rfcu6b0zU9nrehioy7AG-229Uc2aGij5X8vJiV4</recordid><startdate>196009</startdate><enddate>196009</enddate><creator>Swan, H. J C</creator><creator>Beck, Walter</creator><general>American Heart Association, Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>196009</creationdate><title>Ventricular Nonmixing as a Source of Error in the Estimation of Ventricular Volume by the Indicator-Dilution Technic</title><author>Swan, H. J C ; Beck, Walter</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4135-5500fdadab40e73073010ffeef48d992bd84f4b8eb50421110a034cd8df25cf23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1960</creationdate><topic>Heart - physiology</topic><topic>Heart Ventricles</topic><topic>Humans</topic><topic>Indicator Dilution Techniques</topic><topic>Old Medline</topic><topic>Regression Analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Swan, H. J C</creatorcontrib><creatorcontrib>Beck, Walter</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Circulation research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Swan, H. J C</au><au>Beck, Walter</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Ventricular Nonmixing as a Source of Error in the Estimation of Ventricular Volume by the Indicator-Dilution Technic</atitle><jtitle>Circulation research</jtitle><addtitle>Circ Res</addtitle><date>1960-09</date><risdate>1960</risdate><volume>8</volume><issue>5</issue><spage>989</spage><epage>998</epage><pages>989-998</pages><issn>0009-7330</issn><eissn>1524-4571</eissn><abstract>1. In the anesthetized dog, end-diastolic, end-systolic and stroke volumes for the left ventricle have been calculated according to the method of Holt from dilution curves recorded at the aortic root. For heart rates of less than 120 beats per minute, the catheterdensitometer systems used gave 90 to 95 per cent of the true concentration in the aortic root at the end of diastole.2. Average volumes of 2.96, 1.63 and 1.33 ml./Kg. of body weight were calculated for each of these parameters. The interindividual and intraindividual variations about these means amounted to ± 30 to 50 per cent.3. In approximately 15 per cent of the dilution curves the concentration of dye in the aortic root during early systole (phase of maximal ejection) showed a transient, markedly low value compared with that of the end of diastole. This can be explained only on the basis of the preferential ejection from the heart in early systole of the undyed, newly entering blood from the left atrium, which had mixed poorly with the residual volume of the ventricle. Qualitative inspection of cineangiograms confirmed this impression and demonstrated that a residuum of contrast medium failed to mix with the incoming blood from the left atrium.4. In addition, there is evidence for the possibility of overestiination of stroke volumes from dilution curves recorded immediately proximal to the injection chamber.5. Incomplete mixing of the left artial blood with the residual volume of the ventricle precludes accurate quantitation of the changes of volume in the ventricle by the simple formulas proposed by previous authors. This phenomenon may serve to explain the considerable variability that is found in the present study and in the literature.</abstract><cop>United States</cop><pub>American Heart Association, Inc</pub><pmid>13774206</pmid><doi>10.1161/01.RES.8.5.989</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0009-7330 |
ispartof | Circulation research, 1960-09, Vol.8 (5), p.989-998 |
issn | 0009-7330 1524-4571 |
language | eng |
recordid | cdi_proquest_miscellaneous_82571128 |
source | MEDLINE; American Heart Association Journals; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Journals@Ovid Complete |
subjects | Heart - physiology Heart Ventricles Humans Indicator Dilution Techniques Old Medline Regression Analysis |
title | Ventricular Nonmixing as a Source of Error in the Estimation of Ventricular Volume by the Indicator-Dilution Technic |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T08%3A34%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Ventricular%20Nonmixing%20as%20a%20Source%20of%20Error%20in%20the%20Estimation%20of%20Ventricular%20Volume%20by%20the%20Indicator-Dilution%20Technic&rft.jtitle=Circulation%20research&rft.au=Swan,%20H.%20J%20C&rft.date=1960-09&rft.volume=8&rft.issue=5&rft.spage=989&rft.epage=998&rft.pages=989-998&rft.issn=0009-7330&rft.eissn=1524-4571&rft_id=info:doi/10.1161/01.RES.8.5.989&rft_dat=%3Cproquest_cross%3E82571128%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=82571128&rft_id=info:pmid/13774206&rfr_iscdi=true |