Variations of the Timing of Deflections in the His Bundle Recordings
Clinical and experimental studies were performed to examine the meaning and implication of the "His bundle spike" recorded with the current techniques. Tracings obtained with various locations of electrodes along the A-V conducting system revealed that the more ventricularly the sensing el...
Gespeichert in:
Veröffentlicht in: | Japanese Heart Journal 1974, Vol.15(3), pp.239-247 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 247 |
---|---|
container_issue | 3 |
container_start_page | 239 |
container_title | Japanese Heart Journal |
container_volume | 15 |
creator | MATSUO, Hiroshi CHEN, Chia-Maou SATO, Iwao KATO, Ryoko YAMAMOTO, Hideo SHIMOMURA, Katsuro MASHIMA, Saburo HARUMI, Kenichi MURAO, Satoru |
description | Clinical and experimental studies were performed to examine the meaning and implication of the "His bundle spike" recorded with the current techniques. Tracings obtained with various locations of electrodes along the A-V conducting system revealed that the more ventricularly the sensing electrode(s) was (were) introduced, the shorter the interval between the "His bundle spike" and the onset of ventricular deflections (spike-Q interval) on the electrogram. The His bundle and bundle branch potentials should be understood not as the discrete phenomena but as the local manifestations of the suc-cessive depolarization of the A-V conducting system. The His potential observed in a bipolar lead with 2 catheter electrodes was occasionally not seen in a unipolar lead with one of the 2 electrodes, therefore, the measurement of the intervals of the deflections would be of clearer meaning with unipolar lead which is more suitable for detailed study of the A-V conduction. Calculated condution velocity in human His bundle approximated to 1.25M/sec. |
doi_str_mv | 10.1536/ihj.15.239 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_82498209</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>82498209</sourcerecordid><originalsourceid>FETCH-LOGICAL-c504t-a441931c13b6304a5c5b0946be2c00482160b903e06943095c73cbfda82b7a503</originalsourceid><addsrcrecordid>eNo9kM1LwzAYh4Moc04v3oWePAidb5o0TY66qRMGgkzxFtI03TL6oUl78L83tWOX94Pn4Xf4IXSNYY5Twu7tbh-OeULECZpiQnnMMvJ1iqYACY4pZ_wcXXi_B8As4WSCJjSlTGR0ipafylnV2bbxUVtG3c5EG1vbZjt8S1NWRo_QNv9wZX302DdFZaJ3o1tXBNVforNSVd5cHfYMfTw_bRareP328rp4WMc6BdrFilIsCNaY5IwAValOcxCU5SbRAJQnmEEugBhgghIQqc6IzstC8STPVApkhm7H3G_X_vTGd7K2XpuqUo1pey95QgVPQATxbhS1a713ppTfztbK_UoMcqhMhsrCIUNlQb45pPZ5bYqjeugo8MXI975TW3PkynVWV2aIwoINuZKMI6Qeqd4pJ01D_gA8KXzh</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>82498209</pqid></control><display><type>article</type><title>Variations of the Timing of Deflections in the His Bundle Recordings</title><source>J-STAGE Free</source><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>MATSUO, Hiroshi ; CHEN, Chia-Maou ; SATO, Iwao ; KATO, Ryoko ; YAMAMOTO, Hideo ; SHIMOMURA, Katsuro ; MASHIMA, Saburo ; HARUMI, Kenichi ; MURAO, Satoru</creator><creatorcontrib>MATSUO, Hiroshi ; CHEN, Chia-Maou ; SATO, Iwao ; KATO, Ryoko ; YAMAMOTO, Hideo ; SHIMOMURA, Katsuro ; MASHIMA, Saburo ; HARUMI, Kenichi ; MURAO, Satoru</creatorcontrib><description>Clinical and experimental studies were performed to examine the meaning and implication of the "His bundle spike" recorded with the current techniques. Tracings obtained with various locations of electrodes along the A-V conducting system revealed that the more ventricularly the sensing electrode(s) was (were) introduced, the shorter the interval between the "His bundle spike" and the onset of ventricular deflections (spike-Q interval) on the electrogram. The His bundle and bundle branch potentials should be understood not as the discrete phenomena but as the local manifestations of the suc-cessive depolarization of the A-V conducting system. The His potential observed in a bipolar lead with 2 catheter electrodes was occasionally not seen in a unipolar lead with one of the 2 electrodes, therefore, the measurement of the intervals of the deflections would be of clearer meaning with unipolar lead which is more suitable for detailed study of the A-V conduction. Calculated condution velocity in human His bundle approximated to 1.25M/sec.</description><identifier>ISSN: 0021-4868</identifier><identifier>EISSN: 1348-673X</identifier><identifier>DOI: 10.1536/ihj.15.239</identifier><identifier>PMID: 4546974</identifier><language>eng</language><publisher>Japan: International Heart Journal Association</publisher><subject>Animals ; Bipolar lead ; Conduction velocity in human His bundle ; Dogs ; Electrocardiography ; Electrodes ; Heart Conduction System - physiopathology ; His bundle electrogram ; Humans ; Methods ; Unipolar lead</subject><ispartof>Japanese Heart Journal, 1974, Vol.15(3), pp.239-247</ispartof><rights>by International Heart Journal Association</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,1877,27905,27906</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/4546974$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>MATSUO, Hiroshi</creatorcontrib><creatorcontrib>CHEN, Chia-Maou</creatorcontrib><creatorcontrib>SATO, Iwao</creatorcontrib><creatorcontrib>KATO, Ryoko</creatorcontrib><creatorcontrib>YAMAMOTO, Hideo</creatorcontrib><creatorcontrib>SHIMOMURA, Katsuro</creatorcontrib><creatorcontrib>MASHIMA, Saburo</creatorcontrib><creatorcontrib>HARUMI, Kenichi</creatorcontrib><creatorcontrib>MURAO, Satoru</creatorcontrib><title>Variations of the Timing of Deflections in the His Bundle Recordings</title><title>Japanese Heart Journal</title><addtitle>Jpn Heart J</addtitle><description>Clinical and experimental studies were performed to examine the meaning and implication of the "His bundle spike" recorded with the current techniques. Tracings obtained with various locations of electrodes along the A-V conducting system revealed that the more ventricularly the sensing electrode(s) was (were) introduced, the shorter the interval between the "His bundle spike" and the onset of ventricular deflections (spike-Q interval) on the electrogram. The His bundle and bundle branch potentials should be understood not as the discrete phenomena but as the local manifestations of the suc-cessive depolarization of the A-V conducting system. The His potential observed in a bipolar lead with 2 catheter electrodes was occasionally not seen in a unipolar lead with one of the 2 electrodes, therefore, the measurement of the intervals of the deflections would be of clearer meaning with unipolar lead which is more suitable for detailed study of the A-V conduction. Calculated condution velocity in human His bundle approximated to 1.25M/sec.</description><subject>Animals</subject><subject>Bipolar lead</subject><subject>Conduction velocity in human His bundle</subject><subject>Dogs</subject><subject>Electrocardiography</subject><subject>Electrodes</subject><subject>Heart Conduction System - physiopathology</subject><subject>His bundle electrogram</subject><subject>Humans</subject><subject>Methods</subject><subject>Unipolar lead</subject><issn>0021-4868</issn><issn>1348-673X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1974</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kM1LwzAYh4Moc04v3oWePAidb5o0TY66qRMGgkzxFtI03TL6oUl78L83tWOX94Pn4Xf4IXSNYY5Twu7tbh-OeULECZpiQnnMMvJ1iqYACY4pZ_wcXXi_B8As4WSCJjSlTGR0ipafylnV2bbxUVtG3c5EG1vbZjt8S1NWRo_QNv9wZX302DdFZaJ3o1tXBNVforNSVd5cHfYMfTw_bRareP328rp4WMc6BdrFilIsCNaY5IwAValOcxCU5SbRAJQnmEEugBhgghIQqc6IzstC8STPVApkhm7H3G_X_vTGd7K2XpuqUo1pey95QgVPQATxbhS1a713ppTfztbK_UoMcqhMhsrCIUNlQb45pPZ5bYqjeugo8MXI975TW3PkynVWV2aIwoINuZKMI6Qeqd4pJ01D_gA8KXzh</recordid><startdate>19740101</startdate><enddate>19740101</enddate><creator>MATSUO, Hiroshi</creator><creator>CHEN, Chia-Maou</creator><creator>SATO, Iwao</creator><creator>KATO, Ryoko</creator><creator>YAMAMOTO, Hideo</creator><creator>SHIMOMURA, Katsuro</creator><creator>MASHIMA, Saburo</creator><creator>HARUMI, Kenichi</creator><creator>MURAO, Satoru</creator><general>International Heart Journal Association</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19740101</creationdate><title>Variations of the Timing of Deflections in the His Bundle Recordings</title><author>MATSUO, Hiroshi ; CHEN, Chia-Maou ; SATO, Iwao ; KATO, Ryoko ; YAMAMOTO, Hideo ; SHIMOMURA, Katsuro ; MASHIMA, Saburo ; HARUMI, Kenichi ; MURAO, Satoru</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c504t-a441931c13b6304a5c5b0946be2c00482160b903e06943095c73cbfda82b7a503</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1974</creationdate><topic>Animals</topic><topic>Bipolar lead</topic><topic>Conduction velocity in human His bundle</topic><topic>Dogs</topic><topic>Electrocardiography</topic><topic>Electrodes</topic><topic>Heart Conduction System - physiopathology</topic><topic>His bundle electrogram</topic><topic>Humans</topic><topic>Methods</topic><topic>Unipolar lead</topic><toplevel>online_resources</toplevel><creatorcontrib>MATSUO, Hiroshi</creatorcontrib><creatorcontrib>CHEN, Chia-Maou</creatorcontrib><creatorcontrib>SATO, Iwao</creatorcontrib><creatorcontrib>KATO, Ryoko</creatorcontrib><creatorcontrib>YAMAMOTO, Hideo</creatorcontrib><creatorcontrib>SHIMOMURA, Katsuro</creatorcontrib><creatorcontrib>MASHIMA, Saburo</creatorcontrib><creatorcontrib>HARUMI, Kenichi</creatorcontrib><creatorcontrib>MURAO, Satoru</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Japanese Heart Journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>MATSUO, Hiroshi</au><au>CHEN, Chia-Maou</au><au>SATO, Iwao</au><au>KATO, Ryoko</au><au>YAMAMOTO, Hideo</au><au>SHIMOMURA, Katsuro</au><au>MASHIMA, Saburo</au><au>HARUMI, Kenichi</au><au>MURAO, Satoru</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Variations of the Timing of Deflections in the His Bundle Recordings</atitle><jtitle>Japanese Heart Journal</jtitle><addtitle>Jpn Heart J</addtitle><date>1974-01-01</date><risdate>1974</risdate><volume>15</volume><issue>3</issue><spage>239</spage><epage>247</epage><pages>239-247</pages><issn>0021-4868</issn><eissn>1348-673X</eissn><abstract>Clinical and experimental studies were performed to examine the meaning and implication of the "His bundle spike" recorded with the current techniques. Tracings obtained with various locations of electrodes along the A-V conducting system revealed that the more ventricularly the sensing electrode(s) was (were) introduced, the shorter the interval between the "His bundle spike" and the onset of ventricular deflections (spike-Q interval) on the electrogram. The His bundle and bundle branch potentials should be understood not as the discrete phenomena but as the local manifestations of the suc-cessive depolarization of the A-V conducting system. The His potential observed in a bipolar lead with 2 catheter electrodes was occasionally not seen in a unipolar lead with one of the 2 electrodes, therefore, the measurement of the intervals of the deflections would be of clearer meaning with unipolar lead which is more suitable for detailed study of the A-V conduction. Calculated condution velocity in human His bundle approximated to 1.25M/sec.</abstract><cop>Japan</cop><pub>International Heart Journal Association</pub><pmid>4546974</pmid><doi>10.1536/ihj.15.239</doi><tpages>9</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0021-4868 |
ispartof | Japanese Heart Journal, 1974, Vol.15(3), pp.239-247 |
issn | 0021-4868 1348-673X |
language | eng |
recordid | cdi_proquest_miscellaneous_82498209 |
source | J-STAGE Free; MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals |
subjects | Animals Bipolar lead Conduction velocity in human His bundle Dogs Electrocardiography Electrodes Heart Conduction System - physiopathology His bundle electrogram Humans Methods Unipolar lead |
title | Variations of the Timing of Deflections in the His Bundle Recordings |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T12%3A57%3A52IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Variations%20of%20the%20Timing%20of%20Deflections%20in%20the%20His%20Bundle%20Recordings&rft.jtitle=Japanese%20Heart%20Journal&rft.au=MATSUO,%20Hiroshi&rft.date=1974-01-01&rft.volume=15&rft.issue=3&rft.spage=239&rft.epage=247&rft.pages=239-247&rft.issn=0021-4868&rft.eissn=1348-673X&rft_id=info:doi/10.1536/ihj.15.239&rft_dat=%3Cproquest_cross%3E82498209%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=82498209&rft_id=info:pmid/4546974&rfr_iscdi=true |