Physiologic basis for assessing critical coronary stenosis: Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve

Quantitative hemodynamic assessment of coronary stenosis has not been previously reported. Resting coronary blood flow and its regional distribution are insensitive indexes for determining critical stenosis, but flow response to a hyperemic stimulus quantifies restrictions on maximal flow due to cor...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The American journal of cardiology 1974, Vol.33 (1), p.87-94
Hauptverfasser: Gould, K.Lance, Lipscomb, Kirk, Hamilton, Glen W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 94
container_issue 1
container_start_page 87
container_title The American journal of cardiology
container_volume 33
creator Gould, K.Lance
Lipscomb, Kirk
Hamilton, Glen W.
description Quantitative hemodynamic assessment of coronary stenosis has not been previously reported. Resting coronary blood flow and its regional distribution are insensitive indexes for determining critical stenosis, but flow response to a hyperemic stimulus quantifies restrictions on maximal flow due to coronary arterial lesions. Coronary flow responses to temporary occlusion and to selective main coronary arterial injection of sodium diatrizoate (Hypaque-M 75 percent) were studied in 12 consecutive dogs with a surgically implanted electromagnetic flowmeter and separate micrometer constrictor on the left circumflex coronary artery. Selective Hypaque injection adequate for coronary cineangiography increased coronary flow to four times the resting base-line value, peaking at 6 seconds and lasting 3 minutes, a response equivalent to hyperemia after 10 seconds of circumflex arterial occlusion. With progressive micrometer constriction, resting flow measurements did not decrease until there was 85 percent stenosis. Hyperemia after intracoronary injection of Hypaque decreased when there was 30 to 45 percent stenosis and disappeared when there was 88 to 93 percent stenosis. Myocardial images obtained by gamma camera after left atrial injection of 131iodine-macroaggregated albumin demonstrated uniform regional distribution of resting flow in spite of severe constriction. However, 6 seconds after selective Hypaque injection, left atrial injection of 99mtechnetium macroaggregates demonstrated distinct perfusion abnormalities in the region of circumflex stenosis. Thus, flow distribution with a severe lesion was normal at rest but showed marked differences due to restricted circumflex versus normal anterior descending hyperemic response after injection of Hypaque. Flow response and regional distribution during coronary hyperemia caused by Hypaque are quantitative measures for physiologically assessing critical coronary stenosis and flow reserve with potential applicability to patients.
doi_str_mv 10.1016/0002-9149(74)90743-7
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_82279878</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0002914974907437</els_id><sourcerecordid>82279878</sourcerecordid><originalsourceid>FETCH-LOGICAL-e261t-7d0f7ce02981e64cb3477a069dea12d99dee581da109957869512b64f1b938673</originalsourceid><addsrcrecordid>eNpFkd1q3DAQhUVoSTc_b5CCrkp74VbjP0m9KJTQtIFAepFcC1kab1Rsa6uxU_at-ojRZjctCIbDnPk00mHsAsRHENB-EkKUhYZav5f1By1kXRXyiK1ASV2AhuoVW_2zvGEnRL-yBGjaY3ZcK6GaRq7Y358PWwpxiOvgeGcpEO9j4pYIicK05i6FOTg7cBdTnGzacppxitn4mV9PNNspH4xLnhviH56QNnEi5HbyWaxDnhm4DzSn0C1zltwv6Rn8wnvYbjDhGGy-lY9oackQHvv_jhcypkc8Y697OxCeH-opu7_6dnf5o7i5_X59-fWmwLKFuZBe9NKhKLUCbGvXVbWUVrTao4XS61yxUeAtCK0bqVrdQNm1dQ-drlQrq1P2bs_dpPh7QZrNGMjhMOxfa1RZSq2kysa3B-PSjejNJoUxL20OX5z7X_Z9zNs-BkyGXMDJoQ8J3Wx8DAaE2UVqdnmZXV5G1uY5UiOrJyiWl_c</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>82279878</pqid></control><display><type>article</type><title>Physiologic basis for assessing critical coronary stenosis: Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>Gould, K.Lance ; Lipscomb, Kirk ; Hamilton, Glen W.</creator><creatorcontrib>Gould, K.Lance ; Lipscomb, Kirk ; Hamilton, Glen W.</creatorcontrib><description>Quantitative hemodynamic assessment of coronary stenosis has not been previously reported. Resting coronary blood flow and its regional distribution are insensitive indexes for determining critical stenosis, but flow response to a hyperemic stimulus quantifies restrictions on maximal flow due to coronary arterial lesions. Coronary flow responses to temporary occlusion and to selective main coronary arterial injection of sodium diatrizoate (Hypaque-M 75 percent) were studied in 12 consecutive dogs with a surgically implanted electromagnetic flowmeter and separate micrometer constrictor on the left circumflex coronary artery. Selective Hypaque injection adequate for coronary cineangiography increased coronary flow to four times the resting base-line value, peaking at 6 seconds and lasting 3 minutes, a response equivalent to hyperemia after 10 seconds of circumflex arterial occlusion. With progressive micrometer constriction, resting flow measurements did not decrease until there was 85 percent stenosis. Hyperemia after intracoronary injection of Hypaque decreased when there was 30 to 45 percent stenosis and disappeared when there was 88 to 93 percent stenosis. Myocardial images obtained by gamma camera after left atrial injection of 131iodine-macroaggregated albumin demonstrated uniform regional distribution of resting flow in spite of severe constriction. However, 6 seconds after selective Hypaque injection, left atrial injection of 99mtechnetium macroaggregates demonstrated distinct perfusion abnormalities in the region of circumflex stenosis. Thus, flow distribution with a severe lesion was normal at rest but showed marked differences due to restricted circumflex versus normal anterior descending hyperemic response after injection of Hypaque. Flow response and regional distribution during coronary hyperemia caused by Hypaque are quantitative measures for physiologically assessing critical coronary stenosis and flow reserve with potential applicability to patients.</description><identifier>ISSN: 0002-9149</identifier><identifier>EISSN: 1879-1913</identifier><identifier>DOI: 10.1016/0002-9149(74)90743-7</identifier><identifier>PMID: 4808557</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Animals ; Blood Flow Velocity ; Cineangiography ; Constriction ; Coronary Angiography ; Coronary Circulation ; Coronary Disease - physiopathology ; Coronary Vessels - drug effects ; Diatrizoate - administration &amp; dosage ; Diatrizoate - pharmacology ; Dogs ; Electromagnetic Phenomena ; Hyperemia - physiopathology ; Injections, Intra-Arterial ; Radionuclide Imaging ; Regional Blood Flow ; Serum Albumin, Radio-Iodinated ; Technetium</subject><ispartof>The American journal of cardiology, 1974, Vol.33 (1), p.87-94</ispartof><rights>1974</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/0002914974907437$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3537,4010,27900,27901,27902,65306</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/4808557$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Gould, K.Lance</creatorcontrib><creatorcontrib>Lipscomb, Kirk</creatorcontrib><creatorcontrib>Hamilton, Glen W.</creatorcontrib><title>Physiologic basis for assessing critical coronary stenosis: Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve</title><title>The American journal of cardiology</title><addtitle>Am J Cardiol</addtitle><description>Quantitative hemodynamic assessment of coronary stenosis has not been previously reported. Resting coronary blood flow and its regional distribution are insensitive indexes for determining critical stenosis, but flow response to a hyperemic stimulus quantifies restrictions on maximal flow due to coronary arterial lesions. Coronary flow responses to temporary occlusion and to selective main coronary arterial injection of sodium diatrizoate (Hypaque-M 75 percent) were studied in 12 consecutive dogs with a surgically implanted electromagnetic flowmeter and separate micrometer constrictor on the left circumflex coronary artery. Selective Hypaque injection adequate for coronary cineangiography increased coronary flow to four times the resting base-line value, peaking at 6 seconds and lasting 3 minutes, a response equivalent to hyperemia after 10 seconds of circumflex arterial occlusion. With progressive micrometer constriction, resting flow measurements did not decrease until there was 85 percent stenosis. Hyperemia after intracoronary injection of Hypaque decreased when there was 30 to 45 percent stenosis and disappeared when there was 88 to 93 percent stenosis. Myocardial images obtained by gamma camera after left atrial injection of 131iodine-macroaggregated albumin demonstrated uniform regional distribution of resting flow in spite of severe constriction. However, 6 seconds after selective Hypaque injection, left atrial injection of 99mtechnetium macroaggregates demonstrated distinct perfusion abnormalities in the region of circumflex stenosis. Thus, flow distribution with a severe lesion was normal at rest but showed marked differences due to restricted circumflex versus normal anterior descending hyperemic response after injection of Hypaque. Flow response and regional distribution during coronary hyperemia caused by Hypaque are quantitative measures for physiologically assessing critical coronary stenosis and flow reserve with potential applicability to patients.</description><subject>Animals</subject><subject>Blood Flow Velocity</subject><subject>Cineangiography</subject><subject>Constriction</subject><subject>Coronary Angiography</subject><subject>Coronary Circulation</subject><subject>Coronary Disease - physiopathology</subject><subject>Coronary Vessels - drug effects</subject><subject>Diatrizoate - administration &amp; dosage</subject><subject>Diatrizoate - pharmacology</subject><subject>Dogs</subject><subject>Electromagnetic Phenomena</subject><subject>Hyperemia - physiopathology</subject><subject>Injections, Intra-Arterial</subject><subject>Radionuclide Imaging</subject><subject>Regional Blood Flow</subject><subject>Serum Albumin, Radio-Iodinated</subject><subject>Technetium</subject><issn>0002-9149</issn><issn>1879-1913</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1974</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkd1q3DAQhUVoSTc_b5CCrkp74VbjP0m9KJTQtIFAepFcC1kab1Rsa6uxU_at-ojRZjctCIbDnPk00mHsAsRHENB-EkKUhYZav5f1By1kXRXyiK1ASV2AhuoVW_2zvGEnRL-yBGjaY3ZcK6GaRq7Y358PWwpxiOvgeGcpEO9j4pYIicK05i6FOTg7cBdTnGzacppxitn4mV9PNNspH4xLnhviH56QNnEi5HbyWaxDnhm4DzSn0C1zltwv6Rn8wnvYbjDhGGy-lY9oackQHvv_jhcypkc8Y697OxCeH-opu7_6dnf5o7i5_X59-fWmwLKFuZBe9NKhKLUCbGvXVbWUVrTao4XS61yxUeAtCK0bqVrdQNm1dQ-drlQrq1P2bs_dpPh7QZrNGMjhMOxfa1RZSq2kysa3B-PSjejNJoUxL20OX5z7X_Z9zNs-BkyGXMDJoQ8J3Wx8DAaE2UVqdnmZXV5G1uY5UiOrJyiWl_c</recordid><startdate>1974</startdate><enddate>1974</enddate><creator>Gould, K.Lance</creator><creator>Lipscomb, Kirk</creator><creator>Hamilton, Glen W.</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>1974</creationdate><title>Physiologic basis for assessing critical coronary stenosis: Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve</title><author>Gould, K.Lance ; Lipscomb, Kirk ; Hamilton, Glen W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-e261t-7d0f7ce02981e64cb3477a069dea12d99dee581da109957869512b64f1b938673</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1974</creationdate><topic>Animals</topic><topic>Blood Flow Velocity</topic><topic>Cineangiography</topic><topic>Constriction</topic><topic>Coronary Angiography</topic><topic>Coronary Circulation</topic><topic>Coronary Disease - physiopathology</topic><topic>Coronary Vessels - drug effects</topic><topic>Diatrizoate - administration &amp; dosage</topic><topic>Diatrizoate - pharmacology</topic><topic>Dogs</topic><topic>Electromagnetic Phenomena</topic><topic>Hyperemia - physiopathology</topic><topic>Injections, Intra-Arterial</topic><topic>Radionuclide Imaging</topic><topic>Regional Blood Flow</topic><topic>Serum Albumin, Radio-Iodinated</topic><topic>Technetium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gould, K.Lance</creatorcontrib><creatorcontrib>Lipscomb, Kirk</creatorcontrib><creatorcontrib>Hamilton, Glen W.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>The American journal of cardiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gould, K.Lance</au><au>Lipscomb, Kirk</au><au>Hamilton, Glen W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Physiologic basis for assessing critical coronary stenosis: Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve</atitle><jtitle>The American journal of cardiology</jtitle><addtitle>Am J Cardiol</addtitle><date>1974</date><risdate>1974</risdate><volume>33</volume><issue>1</issue><spage>87</spage><epage>94</epage><pages>87-94</pages><issn>0002-9149</issn><eissn>1879-1913</eissn><abstract>Quantitative hemodynamic assessment of coronary stenosis has not been previously reported. Resting coronary blood flow and its regional distribution are insensitive indexes for determining critical stenosis, but flow response to a hyperemic stimulus quantifies restrictions on maximal flow due to coronary arterial lesions. Coronary flow responses to temporary occlusion and to selective main coronary arterial injection of sodium diatrizoate (Hypaque-M 75 percent) were studied in 12 consecutive dogs with a surgically implanted electromagnetic flowmeter and separate micrometer constrictor on the left circumflex coronary artery. Selective Hypaque injection adequate for coronary cineangiography increased coronary flow to four times the resting base-line value, peaking at 6 seconds and lasting 3 minutes, a response equivalent to hyperemia after 10 seconds of circumflex arterial occlusion. With progressive micrometer constriction, resting flow measurements did not decrease until there was 85 percent stenosis. Hyperemia after intracoronary injection of Hypaque decreased when there was 30 to 45 percent stenosis and disappeared when there was 88 to 93 percent stenosis. Myocardial images obtained by gamma camera after left atrial injection of 131iodine-macroaggregated albumin demonstrated uniform regional distribution of resting flow in spite of severe constriction. However, 6 seconds after selective Hypaque injection, left atrial injection of 99mtechnetium macroaggregates demonstrated distinct perfusion abnormalities in the region of circumflex stenosis. Thus, flow distribution with a severe lesion was normal at rest but showed marked differences due to restricted circumflex versus normal anterior descending hyperemic response after injection of Hypaque. Flow response and regional distribution during coronary hyperemia caused by Hypaque are quantitative measures for physiologically assessing critical coronary stenosis and flow reserve with potential applicability to patients.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>4808557</pmid><doi>10.1016/0002-9149(74)90743-7</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0002-9149
ispartof The American journal of cardiology, 1974, Vol.33 (1), p.87-94
issn 0002-9149
1879-1913
language eng
recordid cdi_proquest_miscellaneous_82279878
source MEDLINE; Elsevier ScienceDirect Journals
subjects Animals
Blood Flow Velocity
Cineangiography
Constriction
Coronary Angiography
Coronary Circulation
Coronary Disease - physiopathology
Coronary Vessels - drug effects
Diatrizoate - administration & dosage
Diatrizoate - pharmacology
Dogs
Electromagnetic Phenomena
Hyperemia - physiopathology
Injections, Intra-Arterial
Radionuclide Imaging
Regional Blood Flow
Serum Albumin, Radio-Iodinated
Technetium
title Physiologic basis for assessing critical coronary stenosis: Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T14%3A44%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Physiologic%20basis%20for%20assessing%20critical%20coronary%20stenosis:%20Instantaneous%20flow%20response%20and%20regional%20distribution%20during%20coronary%20hyperemia%20as%20measures%20of%20coronary%20flow%20reserve&rft.jtitle=The%20American%20journal%20of%20cardiology&rft.au=Gould,%20K.Lance&rft.date=1974&rft.volume=33&rft.issue=1&rft.spage=87&rft.epage=94&rft.pages=87-94&rft.issn=0002-9149&rft.eissn=1879-1913&rft_id=info:doi/10.1016/0002-9149(74)90743-7&rft_dat=%3Cproquest_pubme%3E82279878%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=82279878&rft_id=info:pmid/4808557&rft_els_id=0002914974907437&rfr_iscdi=true