Coronary ostial stenosis, a complication of aortic valve replacement

Eight patients developing coronary ostial stenosis following Starr-Edwards aortic valve placement are reviewed. Coronary perfusion with a balloon tip perfusion catheter was performed during the intraoperative period on all patients and was considered technically satisfactory. Angina pectoris develop...