Influence of sterilization upon a range of properties of experimental bone cements
Bone cement, used to fix prostheses into the bone, must be sterilized prior to implantation. Two sterilization techniques, gamma and beta radiation, were investigated, examining the influence upon molecular weight, static and dynamic mechanical characteristics and rheological properties. A number of...
Gespeichert in:
Veröffentlicht in: | Journal of materials science. Materials in medicine 1997-12, Vol.8 (12), p.849-853 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 853 |
---|---|
container_issue | 12 |
container_start_page | 849 |
container_title | Journal of materials science. Materials in medicine |
container_volume | 8 |
creator | Harper, E J Braden, M Bonfield, W Dingeldein, E Wahlig, H |
description | Bone cement, used to fix prostheses into the bone, must be sterilized prior to implantation. Two sterilization techniques, gamma and beta radiation, were investigated, examining the influence upon molecular weight, static and dynamic mechanical characteristics and rheological properties. A number of experimental cements were studied prepared from methylmethacrylate (MMA) co-polymers, either single powders or powder blends, mixed with MMA monomer. It was found that with both gamma and beta radiation, there was a decrease in molecular weight of all powders, including a MMA/styrene co-polymer, in relation to the radiation dose. This fall in molecular weight resulted in a drop in tensile strength, Young's modulus and strain to failure of all cements tested. However, the deterioration in mechanical strength was highlighted by the dynamic testing. Fatigue lives of cements after testing in tension-tension, at 2 Hz under load control and irradiated with 25 kGy gamma radiation, displayed significant decreases. This result indicated the utmost importance of conducting such tests upon experimental bone cements prior to in vivo use. The rheological time profiles of curing cements were also found to be influenced by 25 kGy gamma radiation, with a reduction of complex viscosity after sterilization. |
doi_str_mv | 10.1023/A:1018545519964 |
format | Article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_821738401</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>317562</sourcerecordid><originalsourceid>FETCH-LOGICAL-c343t-bbf98772b052401e311e3c27abc6b4978175135fb90d5431c70de85747ebaac83</originalsourceid><addsrcrecordid>eNqFkE1PwzAMhiMEYmNw5oYqDnAqOHWyJNymiS9pEhKCc5V0LurUpaNpJeDXk8K4cICDbb3yI7-2GTvmcMEhw8vZFQeupZCSGzMVO2zMpcJUaNS7bAxGqlRIhBE7CGEFAMJIuc9GXKLQGnDMHu99WffkC0qaMgkdtVVdfdiuanzSb2KySWv9y1d30zYbaruKwqDoLYpqTb6zdeIaT0lBgwqHbK-0daCjbZ2w55vrp_lduni4vZ_PFmmBArvUudJopTIHMhPACXmMIlPWFVMnjNJcSY6ydAaWUiAvFCxJSyUUOWsLjRN2_j037vXaU-jydRUKqmvrqelDrjOuUMfRkTz7k1RaaRSA_4IZR9AGBu_TX-Cq6Vsfz82VnKIwmR5sT7ZQ79a0zDfxXbZ9z3--j5_5XoU8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>756349281</pqid></control><display><type>article</type><title>Influence of sterilization upon a range of properties of experimental bone cements</title><source>SpringerLink Journals - AutoHoldings</source><creator>Harper, E J ; Braden, M ; Bonfield, W ; Dingeldein, E ; Wahlig, H</creator><creatorcontrib>Harper, E J ; Braden, M ; Bonfield, W ; Dingeldein, E ; Wahlig, H</creatorcontrib><description>Bone cement, used to fix prostheses into the bone, must be sterilized prior to implantation. Two sterilization techniques, gamma and beta radiation, were investigated, examining the influence upon molecular weight, static and dynamic mechanical characteristics and rheological properties. A number of experimental cements were studied prepared from methylmethacrylate (MMA) co-polymers, either single powders or powder blends, mixed with MMA monomer. It was found that with both gamma and beta radiation, there was a decrease in molecular weight of all powders, including a MMA/styrene co-polymer, in relation to the radiation dose. This fall in molecular weight resulted in a drop in tensile strength, Young's modulus and strain to failure of all cements tested. However, the deterioration in mechanical strength was highlighted by the dynamic testing. Fatigue lives of cements after testing in tension-tension, at 2 Hz under load control and irradiated with 25 kGy gamma radiation, displayed significant decreases. This result indicated the utmost importance of conducting such tests upon experimental bone cements prior to in vivo use. The rheological time profiles of curing cements were also found to be influenced by 25 kGy gamma radiation, with a reduction of complex viscosity after sterilization.</description><identifier>ISSN: 0957-4530</identifier><identifier>EISSN: 1573-4838</identifier><identifier>DOI: 10.1023/A:1018545519964</identifier><identifier>PMID: 15348803</identifier><language>eng</language><publisher>United States: Springer Nature B.V</publisher><subject>Biomedical materials ; Dosimetry ; Elastic moduli ; Food science ; Gamma rays ; Implants (surgical) ; Materials science ; Molecular weight ; Radiation effects ; Rheology ; Sterilization (cleaning) ; Tensile strength ; Viscosity</subject><ispartof>Journal of materials science. Materials in medicine, 1997-12, Vol.8 (12), p.849-853</ispartof><rights>Chapman and Hall 1997</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c343t-bbf98772b052401e311e3c27abc6b4978175135fb90d5431c70de85747ebaac83</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15348803$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Harper, E J</creatorcontrib><creatorcontrib>Braden, M</creatorcontrib><creatorcontrib>Bonfield, W</creatorcontrib><creatorcontrib>Dingeldein, E</creatorcontrib><creatorcontrib>Wahlig, H</creatorcontrib><title>Influence of sterilization upon a range of properties of experimental bone cements</title><title>Journal of materials science. Materials in medicine</title><addtitle>J Mater Sci Mater Med</addtitle><description>Bone cement, used to fix prostheses into the bone, must be sterilized prior to implantation. Two sterilization techniques, gamma and beta radiation, were investigated, examining the influence upon molecular weight, static and dynamic mechanical characteristics and rheological properties. A number of experimental cements were studied prepared from methylmethacrylate (MMA) co-polymers, either single powders or powder blends, mixed with MMA monomer. It was found that with both gamma and beta radiation, there was a decrease in molecular weight of all powders, including a MMA/styrene co-polymer, in relation to the radiation dose. This fall in molecular weight resulted in a drop in tensile strength, Young's modulus and strain to failure of all cements tested. However, the deterioration in mechanical strength was highlighted by the dynamic testing. Fatigue lives of cements after testing in tension-tension, at 2 Hz under load control and irradiated with 25 kGy gamma radiation, displayed significant decreases. This result indicated the utmost importance of conducting such tests upon experimental bone cements prior to in vivo use. The rheological time profiles of curing cements were also found to be influenced by 25 kGy gamma radiation, with a reduction of complex viscosity after sterilization.</description><subject>Biomedical materials</subject><subject>Dosimetry</subject><subject>Elastic moduli</subject><subject>Food science</subject><subject>Gamma rays</subject><subject>Implants (surgical)</subject><subject>Materials science</subject><subject>Molecular weight</subject><subject>Radiation effects</subject><subject>Rheology</subject><subject>Sterilization (cleaning)</subject><subject>Tensile strength</subject><subject>Viscosity</subject><issn>0957-4530</issn><issn>1573-4838</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GNUQQ</sourceid><recordid>eNqFkE1PwzAMhiMEYmNw5oYqDnAqOHWyJNymiS9pEhKCc5V0LurUpaNpJeDXk8K4cICDbb3yI7-2GTvmcMEhw8vZFQeupZCSGzMVO2zMpcJUaNS7bAxGqlRIhBE7CGEFAMJIuc9GXKLQGnDMHu99WffkC0qaMgkdtVVdfdiuanzSb2KySWv9y1d30zYbaruKwqDoLYpqTb6zdeIaT0lBgwqHbK-0daCjbZ2w55vrp_lduni4vZ_PFmmBArvUudJopTIHMhPACXmMIlPWFVMnjNJcSY6ydAaWUiAvFCxJSyUUOWsLjRN2_j037vXaU-jydRUKqmvrqelDrjOuUMfRkTz7k1RaaRSA_4IZR9AGBu_TX-Cq6Vsfz82VnKIwmR5sT7ZQ79a0zDfxXbZ9z3--j5_5XoU8</recordid><startdate>199712</startdate><enddate>199712</enddate><creator>Harper, E J</creator><creator>Braden, M</creator><creator>Bonfield, W</creator><creator>Dingeldein, E</creator><creator>Wahlig, H</creator><general>Springer Nature B.V</general><scope>NPM</scope><scope>3V.</scope><scope>7QF</scope><scope>7QO</scope><scope>7QQ</scope><scope>7SC</scope><scope>7SE</scope><scope>7SP</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>7U5</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>88I</scope><scope>8AO</scope><scope>8BQ</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>F28</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>H8D</scope><scope>H8G</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>JQ2</scope><scope>K9.</scope><scope>KB.</scope><scope>KR7</scope><scope>L7M</scope><scope>LK8</scope><scope>L~C</scope><scope>L~D</scope><scope>M0S</scope><scope>M1P</scope><scope>M2P</scope><scope>M7P</scope><scope>P64</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>S0W</scope><scope>7X8</scope></search><sort><creationdate>199712</creationdate><title>Influence of sterilization upon a range of properties of experimental bone cements</title><author>Harper, E J ; Braden, M ; Bonfield, W ; Dingeldein, E ; Wahlig, H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c343t-bbf98772b052401e311e3c27abc6b4978175135fb90d5431c70de85747ebaac83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Biomedical materials</topic><topic>Dosimetry</topic><topic>Elastic moduli</topic><topic>Food science</topic><topic>Gamma rays</topic><topic>Implants (surgical)</topic><topic>Materials science</topic><topic>Molecular weight</topic><topic>Radiation effects</topic><topic>Rheology</topic><topic>Sterilization (cleaning)</topic><topic>Tensile strength</topic><topic>Viscosity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Harper, E J</creatorcontrib><creatorcontrib>Braden, M</creatorcontrib><creatorcontrib>Bonfield, W</creatorcontrib><creatorcontrib>Dingeldein, E</creatorcontrib><creatorcontrib>Wahlig, H</creatorcontrib><collection>PubMed</collection><collection>ProQuest Central (Corporate)</collection><collection>Aluminium Industry Abstracts</collection><collection>Biotechnology Research Abstracts</collection><collection>Ceramic Abstracts</collection><collection>Computer and Information Systems Abstracts</collection><collection>Corrosion Abstracts</collection><collection>Electronics & Communications Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical & Transportation Engineering Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Health & Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>ANTE: Abstracts in New Technology & Engineering</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Aerospace Database</collection><collection>Copper Technical Reference Library</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>ProQuest Computer Science Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Materials Science Database</collection><collection>Civil Engineering Abstracts</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ProQuest Biological Science Collection</collection><collection>Computer and Information Systems Abstracts Academic</collection><collection>Computer and Information Systems Abstracts Professional</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>Science Database</collection><collection>Biological Science Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>DELNET Engineering & Technology Collection</collection><collection>MEDLINE - Academic</collection><jtitle>Journal of materials science. Materials in medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Harper, E J</au><au>Braden, M</au><au>Bonfield, W</au><au>Dingeldein, E</au><au>Wahlig, H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of sterilization upon a range of properties of experimental bone cements</atitle><jtitle>Journal of materials science. Materials in medicine</jtitle><addtitle>J Mater Sci Mater Med</addtitle><date>1997-12</date><risdate>1997</risdate><volume>8</volume><issue>12</issue><spage>849</spage><epage>853</epage><pages>849-853</pages><issn>0957-4530</issn><eissn>1573-4838</eissn><abstract>Bone cement, used to fix prostheses into the bone, must be sterilized prior to implantation. Two sterilization techniques, gamma and beta radiation, were investigated, examining the influence upon molecular weight, static and dynamic mechanical characteristics and rheological properties. A number of experimental cements were studied prepared from methylmethacrylate (MMA) co-polymers, either single powders or powder blends, mixed with MMA monomer. It was found that with both gamma and beta radiation, there was a decrease in molecular weight of all powders, including a MMA/styrene co-polymer, in relation to the radiation dose. This fall in molecular weight resulted in a drop in tensile strength, Young's modulus and strain to failure of all cements tested. However, the deterioration in mechanical strength was highlighted by the dynamic testing. Fatigue lives of cements after testing in tension-tension, at 2 Hz under load control and irradiated with 25 kGy gamma radiation, displayed significant decreases. This result indicated the utmost importance of conducting such tests upon experimental bone cements prior to in vivo use. The rheological time profiles of curing cements were also found to be influenced by 25 kGy gamma radiation, with a reduction of complex viscosity after sterilization.</abstract><cop>United States</cop><pub>Springer Nature B.V</pub><pmid>15348803</pmid><doi>10.1023/A:1018545519964</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0957-4530 |
ispartof | Journal of materials science. Materials in medicine, 1997-12, Vol.8 (12), p.849-853 |
issn | 0957-4530 1573-4838 |
language | eng |
recordid | cdi_proquest_miscellaneous_821738401 |
source | SpringerLink Journals - AutoHoldings |
subjects | Biomedical materials Dosimetry Elastic moduli Food science Gamma rays Implants (surgical) Materials science Molecular weight Radiation effects Rheology Sterilization (cleaning) Tensile strength Viscosity |
title | Influence of sterilization upon a range of properties of experimental bone cements |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T07%3A45%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20sterilization%20upon%20a%20range%20of%20properties%20of%20experimental%20bone%20cements&rft.jtitle=Journal%20of%20materials%20science.%20Materials%20in%20medicine&rft.au=Harper,%20E%20J&rft.date=1997-12&rft.volume=8&rft.issue=12&rft.spage=849&rft.epage=853&rft.pages=849-853&rft.issn=0957-4530&rft.eissn=1573-4838&rft_id=info:doi/10.1023/A:1018545519964&rft_dat=%3Cproquest_pubme%3E317562%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=756349281&rft_id=info:pmid/15348803&rfr_iscdi=true |