A method to improve contrast in high resolution electron microscopy of ultrathin tissue sections

The general background granularity observed in out-of-focus electron micrographs is discussed as a phase contrast effect, that prevents higher resolution than about 25 Å on low contrast specimens as ultrathin tissue sections. The problem of improving the specimen resolution when dealing with ultrath...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Experimental cell research 1956-06, Vol.10 (3), p.657-664
1. Verfasser: SJOSTRAND, F S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 664
container_issue 3
container_start_page 657
container_title Experimental cell research
container_volume 10
creator SJOSTRAND, F S
description The general background granularity observed in out-of-focus electron micrographs is discussed as a phase contrast effect, that prevents higher resolution than about 25 Å on low contrast specimens as ultrathin tissue sections. The problem of improving the specimen resolution when dealing with ultrathin sections consists of improving the contrast so that in-focus pictures may be used. A method of mounting the sections on formvar nets is described, which makes it possible to obtain pictures of sections, which are partially not supported by a formvar film. The reduced diffuse scattering of the electrons when passing through these areas means a drastic increase of contrast.
doi_str_mv 10.1016/0014-4827(56)90043-X
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_81851918</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>001448275690043X</els_id><sourcerecordid>81851918</sourcerecordid><originalsourceid>FETCH-LOGICAL-c360t-7f0e69e40f7ae83665a073971c8426e0b3839618355f1fde5062f8a4662d51c23</originalsourceid><addsrcrecordid>eNp9kE1LxDAQhoMouq7-A5GcRA_VSdOm6UVYFr9gwYvC3mJNp26kbdYkFfz3pu6iN0-Zw_O-k3kIOWFwyYCJKwCWJZlMi_NcXJQAGU-WO2TCoIQkzdJ0l0x-kQNy6P07AEjJxD45YJxzkKyYkJcZ7TCsbE2DpaZbO_uJVNs-uMoHanq6Mm8r6tDbdgjG9hRb1MHFoTPaWa_t-ovahg5tTIRVDATj_YDURyzy_ojsNVXr8Xj7Tsnz7c3T_D5ZPN49zGeLRHMBISkaQFFiBk1RoeRC5BUUvCyYllkqEF655KVgkud5w5oacxBpI6tMiLTOmU75lJxteuMJHwP6oDrjNbZt1aMdvJJM5qyMBVOSbcDx-95ho9bOdJX7UgzUaFaN2tSoTeVC_ZhVyxg73fYPrx3Wf6GtyghcbwCMV34adMprg73G2rjoQtXW_L_hG0BdiJc</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>81851918</pqid></control><display><type>article</type><title>A method to improve contrast in high resolution electron microscopy of ultrathin tissue sections</title><source>MEDLINE</source><source>Elsevier ScienceDirect Journals</source><creator>SJOSTRAND, F S</creator><creatorcontrib>SJOSTRAND, F S</creatorcontrib><description>The general background granularity observed in out-of-focus electron micrographs is discussed as a phase contrast effect, that prevents higher resolution than about 25 Å on low contrast specimens as ultrathin tissue sections. The problem of improving the specimen resolution when dealing with ultrathin sections consists of improving the contrast so that in-focus pictures may be used. A method of mounting the sections on formvar nets is described, which makes it possible to obtain pictures of sections, which are partially not supported by a formvar film. The reduced diffuse scattering of the electrons when passing through these areas means a drastic increase of contrast.</description><identifier>ISSN: 0014-4827</identifier><identifier>EISSN: 1090-2422</identifier><identifier>DOI: 10.1016/0014-4827(56)90043-X</identifier><identifier>PMID: 13330817</identifier><language>eng</language><publisher>United States: Elsevier Inc</publisher><subject>Electrons ; Microscopy ; Microscopy, Electron ; Old Medline</subject><ispartof>Experimental cell research, 1956-06, Vol.10 (3), p.657-664</ispartof><rights>1956</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c360t-7f0e69e40f7ae83665a073971c8426e0b3839618355f1fde5062f8a4662d51c23</citedby><cites>FETCH-LOGICAL-c360t-7f0e69e40f7ae83665a073971c8426e0b3839618355f1fde5062f8a4662d51c23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/001448275690043X$$EHTML$$P50$$Gelsevier$$H</linktohtml><link.rule.ids>314,776,780,3536,27903,27904,65309</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/13330817$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>SJOSTRAND, F S</creatorcontrib><title>A method to improve contrast in high resolution electron microscopy of ultrathin tissue sections</title><title>Experimental cell research</title><addtitle>Exp Cell Res</addtitle><description>The general background granularity observed in out-of-focus electron micrographs is discussed as a phase contrast effect, that prevents higher resolution than about 25 Å on low contrast specimens as ultrathin tissue sections. The problem of improving the specimen resolution when dealing with ultrathin sections consists of improving the contrast so that in-focus pictures may be used. A method of mounting the sections on formvar nets is described, which makes it possible to obtain pictures of sections, which are partially not supported by a formvar film. The reduced diffuse scattering of the electrons when passing through these areas means a drastic increase of contrast.</description><subject>Electrons</subject><subject>Microscopy</subject><subject>Microscopy, Electron</subject><subject>Old Medline</subject><issn>0014-4827</issn><issn>1090-2422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1956</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kE1LxDAQhoMouq7-A5GcRA_VSdOm6UVYFr9gwYvC3mJNp26kbdYkFfz3pu6iN0-Zw_O-k3kIOWFwyYCJKwCWJZlMi_NcXJQAGU-WO2TCoIQkzdJ0l0x-kQNy6P07AEjJxD45YJxzkKyYkJcZ7TCsbE2DpaZbO_uJVNs-uMoHanq6Mm8r6tDbdgjG9hRb1MHFoTPaWa_t-ovahg5tTIRVDATj_YDURyzy_ojsNVXr8Xj7Tsnz7c3T_D5ZPN49zGeLRHMBISkaQFFiBk1RoeRC5BUUvCyYllkqEF655KVgkud5w5oacxBpI6tMiLTOmU75lJxteuMJHwP6oDrjNbZt1aMdvJJM5qyMBVOSbcDx-95ho9bOdJX7UgzUaFaN2tSoTeVC_ZhVyxg73fYPrx3Wf6GtyghcbwCMV34adMprg73G2rjoQtXW_L_hG0BdiJc</recordid><startdate>195606</startdate><enddate>195606</enddate><creator>SJOSTRAND, F S</creator><general>Elsevier Inc</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>195606</creationdate><title>A method to improve contrast in high resolution electron microscopy of ultrathin tissue sections</title><author>SJOSTRAND, F S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c360t-7f0e69e40f7ae83665a073971c8426e0b3839618355f1fde5062f8a4662d51c23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1956</creationdate><topic>Electrons</topic><topic>Microscopy</topic><topic>Microscopy, Electron</topic><topic>Old Medline</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>SJOSTRAND, F S</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Experimental cell research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>SJOSTRAND, F S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A method to improve contrast in high resolution electron microscopy of ultrathin tissue sections</atitle><jtitle>Experimental cell research</jtitle><addtitle>Exp Cell Res</addtitle><date>1956-06</date><risdate>1956</risdate><volume>10</volume><issue>3</issue><spage>657</spage><epage>664</epage><pages>657-664</pages><issn>0014-4827</issn><eissn>1090-2422</eissn><abstract>The general background granularity observed in out-of-focus electron micrographs is discussed as a phase contrast effect, that prevents higher resolution than about 25 Å on low contrast specimens as ultrathin tissue sections. The problem of improving the specimen resolution when dealing with ultrathin sections consists of improving the contrast so that in-focus pictures may be used. A method of mounting the sections on formvar nets is described, which makes it possible to obtain pictures of sections, which are partially not supported by a formvar film. The reduced diffuse scattering of the electrons when passing through these areas means a drastic increase of contrast.</abstract><cop>United States</cop><pub>Elsevier Inc</pub><pmid>13330817</pmid><doi>10.1016/0014-4827(56)90043-X</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0014-4827
ispartof Experimental cell research, 1956-06, Vol.10 (3), p.657-664
issn 0014-4827
1090-2422
language eng
recordid cdi_proquest_miscellaneous_81851918
source MEDLINE; Elsevier ScienceDirect Journals
subjects Electrons
Microscopy
Microscopy, Electron
Old Medline
title A method to improve contrast in high resolution electron microscopy of ultrathin tissue sections
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T23%3A38%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20method%20to%20improve%20contrast%20in%20high%20resolution%20electron%20microscopy%20of%20ultrathin%20tissue%20sections&rft.jtitle=Experimental%20cell%20research&rft.au=SJOSTRAND,%20F%20S&rft.date=1956-06&rft.volume=10&rft.issue=3&rft.spage=657&rft.epage=664&rft.pages=657-664&rft.issn=0014-4827&rft.eissn=1090-2422&rft_id=info:doi/10.1016/0014-4827(56)90043-X&rft_dat=%3Cproquest_cross%3E81851918%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=81851918&rft_id=info:pmid/13330817&rft_els_id=001448275690043X&rfr_iscdi=true