An evaluation of the pulse-contour method of measuring cardiac output

The pulse-contour (PC) method continuously derives the cardiac output in litres per minute from the arterial pressure wave form by using a portable analogue computer. The reliability of the PC method in determining cardiac output was studied in 6 patients during anaesthetic induction for cardiac sur...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:South African medical journal 1984-09, Vol.66 (12), p.451-453
1. Verfasser: Brock-Utne, J.G., Blake, G.T.W., Bosenberg, A.T., Gaffin, S.L., Humphrey, D. & Downing, J.W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 453
container_issue 12
container_start_page 451
container_title South African medical journal
container_volume 66
creator Brock-Utne, J.G., Blake, G.T.W., Bosenberg, A.T., Gaffin, S.L., Humphrey, D. & Downing, J.W.
description The pulse-contour (PC) method continuously derives the cardiac output in litres per minute from the arterial pressure wave form by using a portable analogue computer. The reliability of the PC method in determining cardiac output was studied in 6 patients during anaesthetic induction for cardiac surgery. The results obtained with the PC method using the radial artery to register the arterial pulse wave were compared with cardiac output measurements using the more conventional thermodilution technique. The PC method would seem to offer a simple, clinically useful method for on-line monitoring of short-term variations in cardiac output.
format Article
fullrecord <record><control><sourceid>proquest_JRA</sourceid><recordid>TN_cdi_proquest_miscellaneous_81275245</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sabinet_id>10520/AJA20785135_11231</sabinet_id><sourcerecordid>81275245</sourcerecordid><originalsourceid>FETCH-LOGICAL-p244t-e9effeda55987ff57b7dfddf73869b2c9d8a23dfb9a422ae86f3ed1ab8791b1a3</originalsourceid><addsrcrecordid>eNotkMFKxDAQhoMo67r6CEJP3gJN2jTpsSyrrix40XOYNBO30ja1SQTf3i67p2H4vhlm_iuy5rlUVLBCXJN1zkVFayHLW3IXwne-9KKuVmRVlaqUkq3Jrhkz_IU-Qez8mHmXxSNmU-oD0taP0ac5GzAevT2xASGkuRu_shZm20Gb-RSnFO_JjYNl5OFSN-TzefexfaWH95f9tjnQiZdlpFijc2hhOUJJ54Q00jprnSxUVRve1lYBL6wzNZScA6rKFWgZGCVrZhgUG_J03jvN_idhiHroQot9DyP6FLRiXApeikV8vIjJDGj1NHcDzH_68vfC6ZkHMN2IUQfARdUsFzzXzVtzSvEUomaMF6z4B5L-ZAU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>81275245</pqid></control><display><type>article</type><title>An evaluation of the pulse-contour method of measuring cardiac output</title><source>Sabinet African Journals Open Access Collection</source><creator>Brock-Utne, J.G., Blake, G.T.W., Bosenberg, A.T., Gaffin, S.L., Humphrey, D. &amp; Downing, J.W.</creator><creatorcontrib>Brock-Utne, J.G., Blake, G.T.W., Bosenberg, A.T., Gaffin, S.L., Humphrey, D. &amp; Downing, J.W.</creatorcontrib><description>The pulse-contour (PC) method continuously derives the cardiac output in litres per minute from the arterial pressure wave form by using a portable analogue computer. The reliability of the PC method in determining cardiac output was studied in 6 patients during anaesthetic induction for cardiac surgery. The results obtained with the PC method using the radial artery to register the arterial pulse wave were compared with cardiac output measurements using the more conventional thermodilution technique. The PC method would seem to offer a simple, clinically useful method for on-line monitoring of short-term variations in cardiac output.</description><identifier>ISSN: 0256-9574</identifier><identifier>EISSN: 2078-5135</identifier><identifier>PMID: 6484771</identifier><language>eng</language><publisher>South Africa: Health and Medical Publishing Group (HMPG)</publisher><subject>Adult ; Anaesthesiology ; Cardiac Output ; Evaluation Studies as Topic ; Heart Diseases - physiopathology ; Humans ; Male ; Methods ; Physiology ; Pulse ; Pulse-countour method ; Stroke Volume ; Thermodilution</subject><ispartof>South African medical journal, 1984-09, Vol.66 (12), p.451-453</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,39219</link.rule.ids><linktorsrc>$$Uhttp://hdl.handle.net/10520/AJA20785135_11231$$EView_record_in_Sabinet_Online_Ltd.$$FView_record_in_$$GSabinet_Online_Ltd.</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/6484771$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Brock-Utne, J.G., Blake, G.T.W., Bosenberg, A.T., Gaffin, S.L., Humphrey, D. &amp; Downing, J.W.</creatorcontrib><title>An evaluation of the pulse-contour method of measuring cardiac output</title><title>South African medical journal</title><addtitle>S Afr Med J</addtitle><description>The pulse-contour (PC) method continuously derives the cardiac output in litres per minute from the arterial pressure wave form by using a portable analogue computer. The reliability of the PC method in determining cardiac output was studied in 6 patients during anaesthetic induction for cardiac surgery. The results obtained with the PC method using the radial artery to register the arterial pulse wave were compared with cardiac output measurements using the more conventional thermodilution technique. The PC method would seem to offer a simple, clinically useful method for on-line monitoring of short-term variations in cardiac output.</description><subject>Adult</subject><subject>Anaesthesiology</subject><subject>Cardiac Output</subject><subject>Evaluation Studies as Topic</subject><subject>Heart Diseases - physiopathology</subject><subject>Humans</subject><subject>Male</subject><subject>Methods</subject><subject>Physiology</subject><subject>Pulse</subject><subject>Pulse-countour method</subject><subject>Stroke Volume</subject><subject>Thermodilution</subject><issn>0256-9574</issn><issn>2078-5135</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1984</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNotkMFKxDAQhoMo67r6CEJP3gJN2jTpsSyrrix40XOYNBO30ja1SQTf3i67p2H4vhlm_iuy5rlUVLBCXJN1zkVFayHLW3IXwne-9KKuVmRVlaqUkq3Jrhkz_IU-Qez8mHmXxSNmU-oD0taP0ac5GzAevT2xASGkuRu_shZm20Gb-RSnFO_JjYNl5OFSN-TzefexfaWH95f9tjnQiZdlpFijc2hhOUJJ54Q00jprnSxUVRve1lYBL6wzNZScA6rKFWgZGCVrZhgUG_J03jvN_idhiHroQot9DyP6FLRiXApeikV8vIjJDGj1NHcDzH_68vfC6ZkHMN2IUQfARdUsFzzXzVtzSvEUomaMF6z4B5L-ZAU</recordid><startdate>19840922</startdate><enddate>19840922</enddate><creator>Brock-Utne, J.G., Blake, G.T.W., Bosenberg, A.T., Gaffin, S.L., Humphrey, D. &amp; Downing, J.W.</creator><general>Health and Medical Publishing Group (HMPG)</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>19840922</creationdate><title>An evaluation of the pulse-contour method of measuring cardiac output</title><author>Brock-Utne, J.G., Blake, G.T.W., Bosenberg, A.T., Gaffin, S.L., Humphrey, D. &amp; Downing, J.W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p244t-e9effeda55987ff57b7dfddf73869b2c9d8a23dfb9a422ae86f3ed1ab8791b1a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1984</creationdate><topic>Adult</topic><topic>Anaesthesiology</topic><topic>Cardiac Output</topic><topic>Evaluation Studies as Topic</topic><topic>Heart Diseases - physiopathology</topic><topic>Humans</topic><topic>Male</topic><topic>Methods</topic><topic>Physiology</topic><topic>Pulse</topic><topic>Pulse-countour method</topic><topic>Stroke Volume</topic><topic>Thermodilution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Brock-Utne, J.G., Blake, G.T.W., Bosenberg, A.T., Gaffin, S.L., Humphrey, D. &amp; Downing, J.W.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>South African medical journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Brock-Utne, J.G., Blake, G.T.W., Bosenberg, A.T., Gaffin, S.L., Humphrey, D. &amp; Downing, J.W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An evaluation of the pulse-contour method of measuring cardiac output</atitle><jtitle>South African medical journal</jtitle><addtitle>S Afr Med J</addtitle><date>1984-09-22</date><risdate>1984</risdate><volume>66</volume><issue>12</issue><spage>451</spage><epage>453</epage><pages>451-453</pages><issn>0256-9574</issn><eissn>2078-5135</eissn><abstract>The pulse-contour (PC) method continuously derives the cardiac output in litres per minute from the arterial pressure wave form by using a portable analogue computer. The reliability of the PC method in determining cardiac output was studied in 6 patients during anaesthetic induction for cardiac surgery. The results obtained with the PC method using the radial artery to register the arterial pulse wave were compared with cardiac output measurements using the more conventional thermodilution technique. The PC method would seem to offer a simple, clinically useful method for on-line monitoring of short-term variations in cardiac output.</abstract><cop>South Africa</cop><pub>Health and Medical Publishing Group (HMPG)</pub><pmid>6484771</pmid><tpages>3</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0256-9574
ispartof South African medical journal, 1984-09, Vol.66 (12), p.451-453
issn 0256-9574
2078-5135
language eng
recordid cdi_proquest_miscellaneous_81275245
source Sabinet African Journals Open Access Collection
subjects Adult
Anaesthesiology
Cardiac Output
Evaluation Studies as Topic
Heart Diseases - physiopathology
Humans
Male
Methods
Physiology
Pulse
Pulse-countour method
Stroke Volume
Thermodilution
title An evaluation of the pulse-contour method of measuring cardiac output
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-16T09%3A09%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_JRA&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20evaluation%20of%20the%20pulse-contour%20method%20of%20measuring%20cardiac%20output&rft.jtitle=South%20African%20medical%20journal&rft.au=Brock-Utne,%20J.G.,%20Blake,%20G.T.W.,%20Bosenberg,%20A.T.,%20Gaffin,%20S.L.,%20Humphrey,%20D.%20&%20Downing,%20J.W.&rft.date=1984-09-22&rft.volume=66&rft.issue=12&rft.spage=451&rft.epage=453&rft.pages=451-453&rft.issn=0256-9574&rft.eissn=2078-5135&rft_id=info:doi/&rft_dat=%3Cproquest_JRA%3E81275245%3C/proquest_JRA%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=81275245&rft_id=info:pmid/6484771&rft_sabinet_id=10520/AJA20785135_11231&rfr_iscdi=true