THE STANDARDIZATION OF THE CANDIDATE NATIONAL STANDARD ANTI-D BLOOD-TYPING SERUM WITH THE GROUPAMATIC MG50 SYSTEM

The utility of the Groupamatic MG50 system for quantitative expression of agglutination in terms of continuous response was studied. By use of the characteristics of the design of this system, in which the change in voltage reflects the degree of agglutination, a linear regression relationship betwe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Japanese Journal of Medical Science and Biology 1984, Vol.37(2), pp.83-95
Hauptverfasser: SAITO, Haruichi, OZAKI, Junichi, YASUDA, Junichi, KUROKAWA, Masami, TOMITA, Tadao, OKUBO, Yasuto, TANAKA, Masayoshi, NAKAGAWA, Soichi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 95
container_issue 2
container_start_page 83
container_title Japanese Journal of Medical Science and Biology
container_volume 37
creator SAITO, Haruichi
OZAKI, Junichi
YASUDA, Junichi
KUROKAWA, Masami
TOMITA, Tadao
OKUBO, Yasuto
TANAKA, Masayoshi
NAKAGAWA, Soichi
description The utility of the Groupamatic MG50 system for quantitative expression of agglutination in terms of continuous response was studied. By use of the characteristics of the design of this system, in which the change in voltage reflects the degree of agglutination, a linear regression relationship between the log ratio of light flux obtained by transformation of the voltage and the log dilution factor of the serum was demonstrated. The availability of the parallel line assay method to the standardization of the blood grouping antisera was also described.
doi_str_mv 10.7883/yoken1952.37.83
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_81273076</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>81273076</sourcerecordid><originalsourceid>FETCH-LOGICAL-c414t-490712d4eb68db0d5e6efa23d513828df1c8a86492ba4cda77361716c1a376153</originalsourceid><addsrcrecordid>eNpVUDlvwjAUtqpWFFHmTpU8dQv4im3GlASIBAkCo4oulklMS8sZw8C_bziK1Df4Sd_15A-AZ4waQkraPG5-7Bq3fNKgoiHpHahiKZlHJJH3oIoQwZ6PMXkEdee-UTmcCJ_JCqhwRpkQqAp2qhfBsQqSMBiF8Ueg4jSBaQee4HaJxmGgIpic8aB_U8IgUbEXwrd-moaemg7jpAvH0WgygO-x6p3t3VE6GQaD0tqGg66P4Hg6VtHgCTzMzdLZ-nXXwKQTqXbP66fduB30vYxhtvdYCwlMcmZnXOYzlPuW27khNPcxLf-Xz3EmjeSsRWaGZbkRgnIsMM-woYJjn9bA6yV3W2x2B-v2erVwmV0uzdpuDk5LTARFgpfC5kWYFRvnCjvX22KxMsVRY6RPPetbz5oKLWnpeLlGH2Yrm9_011ZLPrzw325vPu2NN8V-kS3t_7zrU575o7MvU2i7pr9okIfM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>81273076</pqid></control><display><type>article</type><title>THE STANDARDIZATION OF THE CANDIDATE NATIONAL STANDARD ANTI-D BLOOD-TYPING SERUM WITH THE GROUPAMATIC MG50 SYSTEM</title><source>J-STAGE Free</source><source>MEDLINE</source><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><creator>SAITO, Haruichi ; OZAKI, Junichi ; YASUDA, Junichi ; KUROKAWA, Masami ; TOMITA, Tadao ; OKUBO, Yasuto ; TANAKA, Masayoshi ; NAKAGAWA, Soichi</creator><creatorcontrib>SAITO, Haruichi ; OZAKI, Junichi ; YASUDA, Junichi ; KUROKAWA, Masami ; TOMITA, Tadao ; OKUBO, Yasuto ; TANAKA, Masayoshi ; NAKAGAWA, Soichi</creatorcontrib><description>The utility of the Groupamatic MG50 system for quantitative expression of agglutination in terms of continuous response was studied. By use of the characteristics of the design of this system, in which the change in voltage reflects the degree of agglutination, a linear regression relationship between the log ratio of light flux obtained by transformation of the voltage and the log dilution factor of the serum was demonstrated. The availability of the parallel line assay method to the standardization of the blood grouping antisera was also described.</description><identifier>ISSN: 0021-5112</identifier><identifier>EISSN: 1884-2828</identifier><identifier>DOI: 10.7883/yoken1952.37.83</identifier><identifier>PMID: 6434770</identifier><language>eng</language><publisher>Japan: National Institute of Infectious Diseases, Japanese Journal of Infectious Diseases Editorial Committee</publisher><subject>Blood Grouping and Crossmatching - methods ; Hemagglutination Tests - instrumentation ; Humans ; Immune Sera - immunology ; Immune Sera - standards ; Regression Analysis ; Rh-Hr Blood-Group System - immunology</subject><ispartof>Japanese Journal of Medical Science and Biology, 1984, Vol.37(2), pp.83-95</ispartof><rights>author</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c414t-490712d4eb68db0d5e6efa23d513828df1c8a86492ba4cda77361716c1a376153</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,1877,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/6434770$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>SAITO, Haruichi</creatorcontrib><creatorcontrib>OZAKI, Junichi</creatorcontrib><creatorcontrib>YASUDA, Junichi</creatorcontrib><creatorcontrib>KUROKAWA, Masami</creatorcontrib><creatorcontrib>TOMITA, Tadao</creatorcontrib><creatorcontrib>OKUBO, Yasuto</creatorcontrib><creatorcontrib>TANAKA, Masayoshi</creatorcontrib><creatorcontrib>NAKAGAWA, Soichi</creatorcontrib><title>THE STANDARDIZATION OF THE CANDIDATE NATIONAL STANDARD ANTI-D BLOOD-TYPING SERUM WITH THE GROUPAMATIC MG50 SYSTEM</title><title>Japanese Journal of Medical Science and Biology</title><addtitle>JJMSB</addtitle><description>The utility of the Groupamatic MG50 system for quantitative expression of agglutination in terms of continuous response was studied. By use of the characteristics of the design of this system, in which the change in voltage reflects the degree of agglutination, a linear regression relationship between the log ratio of light flux obtained by transformation of the voltage and the log dilution factor of the serum was demonstrated. The availability of the parallel line assay method to the standardization of the blood grouping antisera was also described.</description><subject>Blood Grouping and Crossmatching - methods</subject><subject>Hemagglutination Tests - instrumentation</subject><subject>Humans</subject><subject>Immune Sera - immunology</subject><subject>Immune Sera - standards</subject><subject>Regression Analysis</subject><subject>Rh-Hr Blood-Group System - immunology</subject><issn>0021-5112</issn><issn>1884-2828</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1984</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpVUDlvwjAUtqpWFFHmTpU8dQv4im3GlASIBAkCo4oulklMS8sZw8C_bziK1Df4Sd_15A-AZ4waQkraPG5-7Bq3fNKgoiHpHahiKZlHJJH3oIoQwZ6PMXkEdee-UTmcCJ_JCqhwRpkQqAp2qhfBsQqSMBiF8Ueg4jSBaQee4HaJxmGgIpic8aB_U8IgUbEXwrd-moaemg7jpAvH0WgygO-x6p3t3VE6GQaD0tqGg66P4Hg6VtHgCTzMzdLZ-nXXwKQTqXbP66fduB30vYxhtvdYCwlMcmZnXOYzlPuW27khNPcxLf-Xz3EmjeSsRWaGZbkRgnIsMM-woYJjn9bA6yV3W2x2B-v2erVwmV0uzdpuDk5LTARFgpfC5kWYFRvnCjvX22KxMsVRY6RPPetbz5oKLWnpeLlGH2Yrm9_011ZLPrzw325vPu2NN8V-kS3t_7zrU575o7MvU2i7pr9okIfM</recordid><startdate>19840101</startdate><enddate>19840101</enddate><creator>SAITO, Haruichi</creator><creator>OZAKI, Junichi</creator><creator>YASUDA, Junichi</creator><creator>KUROKAWA, Masami</creator><creator>TOMITA, Tadao</creator><creator>OKUBO, Yasuto</creator><creator>TANAKA, Masayoshi</creator><creator>NAKAGAWA, Soichi</creator><general>National Institute of Infectious Diseases, Japanese Journal of Infectious Diseases Editorial Committee</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19840101</creationdate><title>THE STANDARDIZATION OF THE CANDIDATE NATIONAL STANDARD ANTI-D BLOOD-TYPING SERUM WITH THE GROUPAMATIC MG50 SYSTEM</title><author>SAITO, Haruichi ; OZAKI, Junichi ; YASUDA, Junichi ; KUROKAWA, Masami ; TOMITA, Tadao ; OKUBO, Yasuto ; TANAKA, Masayoshi ; NAKAGAWA, Soichi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c414t-490712d4eb68db0d5e6efa23d513828df1c8a86492ba4cda77361716c1a376153</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1984</creationdate><topic>Blood Grouping and Crossmatching - methods</topic><topic>Hemagglutination Tests - instrumentation</topic><topic>Humans</topic><topic>Immune Sera - immunology</topic><topic>Immune Sera - standards</topic><topic>Regression Analysis</topic><topic>Rh-Hr Blood-Group System - immunology</topic><toplevel>online_resources</toplevel><creatorcontrib>SAITO, Haruichi</creatorcontrib><creatorcontrib>OZAKI, Junichi</creatorcontrib><creatorcontrib>YASUDA, Junichi</creatorcontrib><creatorcontrib>KUROKAWA, Masami</creatorcontrib><creatorcontrib>TOMITA, Tadao</creatorcontrib><creatorcontrib>OKUBO, Yasuto</creatorcontrib><creatorcontrib>TANAKA, Masayoshi</creatorcontrib><creatorcontrib>NAKAGAWA, Soichi</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Japanese Journal of Medical Science and Biology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>SAITO, Haruichi</au><au>OZAKI, Junichi</au><au>YASUDA, Junichi</au><au>KUROKAWA, Masami</au><au>TOMITA, Tadao</au><au>OKUBO, Yasuto</au><au>TANAKA, Masayoshi</au><au>NAKAGAWA, Soichi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>THE STANDARDIZATION OF THE CANDIDATE NATIONAL STANDARD ANTI-D BLOOD-TYPING SERUM WITH THE GROUPAMATIC MG50 SYSTEM</atitle><jtitle>Japanese Journal of Medical Science and Biology</jtitle><addtitle>JJMSB</addtitle><date>1984-01-01</date><risdate>1984</risdate><volume>37</volume><issue>2</issue><spage>83</spage><epage>95</epage><pages>83-95</pages><issn>0021-5112</issn><eissn>1884-2828</eissn><abstract>The utility of the Groupamatic MG50 system for quantitative expression of agglutination in terms of continuous response was studied. By use of the characteristics of the design of this system, in which the change in voltage reflects the degree of agglutination, a linear regression relationship between the log ratio of light flux obtained by transformation of the voltage and the log dilution factor of the serum was demonstrated. The availability of the parallel line assay method to the standardization of the blood grouping antisera was also described.</abstract><cop>Japan</cop><pub>National Institute of Infectious Diseases, Japanese Journal of Infectious Diseases Editorial Committee</pub><pmid>6434770</pmid><doi>10.7883/yoken1952.37.83</doi><tpages>13</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0021-5112
ispartof Japanese Journal of Medical Science and Biology, 1984, Vol.37(2), pp.83-95
issn 0021-5112
1884-2828
language eng
recordid cdi_proquest_miscellaneous_81273076
source J-STAGE Free; MEDLINE; Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals
subjects Blood Grouping and Crossmatching - methods
Hemagglutination Tests - instrumentation
Humans
Immune Sera - immunology
Immune Sera - standards
Regression Analysis
Rh-Hr Blood-Group System - immunology
title THE STANDARDIZATION OF THE CANDIDATE NATIONAL STANDARD ANTI-D BLOOD-TYPING SERUM WITH THE GROUPAMATIC MG50 SYSTEM
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-12T17%3A58%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=THE%20STANDARDIZATION%20OF%20THE%20CANDIDATE%20NATIONAL%20STANDARD%20ANTI-D%20BLOOD-TYPING%20SERUM%20WITH%20THE%20GROUPAMATIC%20MG50%20SYSTEM&rft.jtitle=Japanese%20Journal%20of%20Medical%20Science%20and%20Biology&rft.au=SAITO,%20Haruichi&rft.date=1984-01-01&rft.volume=37&rft.issue=2&rft.spage=83&rft.epage=95&rft.pages=83-95&rft.issn=0021-5112&rft.eissn=1884-2828&rft_id=info:doi/10.7883/yoken1952.37.83&rft_dat=%3Cproquest_cross%3E81273076%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=81273076&rft_id=info:pmid/6434770&rfr_iscdi=true