10-MHz-B-scan sonography of the cervical carotid arteries

Two hundred and eighty-two consecutive patients with cerebro-vascular insufficiency, with non-specific neurological symptoms or asymptomatic murmurs, were examined prospectively by two-dimensional high resolution 10 MHz B-scan real time sonography. Arteriosclerotic plaques were usually semi-circular...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:RöFo : Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebende Verfahren 1984-06, Vol.140 (6), p.677-683
Hauptverfasser: Kuhn, F P, Krämer, G, Bauer, R, Klotter, H J
Format: Artikel
Sprache:ger
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 683
container_issue 6
container_start_page 677
container_title RöFo : Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebende Verfahren
container_volume 140
creator Kuhn, F P
Krämer, G
Bauer, R
Klotter, H J
description Two hundred and eighty-two consecutive patients with cerebro-vascular insufficiency, with non-specific neurological symptoms or asymptomatic murmurs, were examined prospectively by two-dimensional high resolution 10 MHz B-scan real time sonography. Arteriosclerotic plaques were usually semi-circular (77%), of high amplitude (64%) and homogeneous (80%). Ulcerating plaques were correctly diagnosed in only three out of eight cases demonstrated angiographically. So far there has been no definite relationship between the appearance of the plaques and clinical symptoms. Compared with arteriography (170 examinations) the specificity of sonography was 98% (62/63), the sensitivity for plaques was 100% (50/50), for stenoses it was 63% (5/8) to 93% (14/15), for occlusions it was 76% (13/17). The indications and drawbacks of the method are discussed.
format Article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_proquest_miscellaneous_81139203</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>81139203</sourcerecordid><originalsourceid>FETCH-LOGICAL-p533-6acb212d7e33f67bb8cf1ef2ed30621fbb86be2dad0864fc835f6470f38359d53</originalsourceid><addsrcrecordid>eNotj0FLwzAYhnNQ5pz-BCEnb4EkX5smRx3qBhMvu5c0-eIqbVOTTpi_3oI9vS8vDy88V2QtCtDMcGluyG3OX5wXXIBZkZUqpKk0rIkRnL3vftkzy84ONMchfiY7ni40BjqdkDpMP62zHXU2xan11KYJU4v5jlwH22W8X3JDjq8vx-2OHT7e9tunAxtLAKasa6SQvkKAoKqm0S4IDBI9cCVFmAfVoPTWc62K4DSUQRUVDzA340vYkMf_2zHF7zPmqe7b7LDr7IDxnGstZiPJYQYfFvDc9OjrMbW9TZd6UYU_hnVNww</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>81139203</pqid></control><display><type>article</type><title>10-MHz-B-scan sonography of the cervical carotid arteries</title><source>MEDLINE</source><source>Thieme Connect Journals</source><creator>Kuhn, F P ; Krämer, G ; Bauer, R ; Klotter, H J</creator><creatorcontrib>Kuhn, F P ; Krämer, G ; Bauer, R ; Klotter, H J</creatorcontrib><description>Two hundred and eighty-two consecutive patients with cerebro-vascular insufficiency, with non-specific neurological symptoms or asymptomatic murmurs, were examined prospectively by two-dimensional high resolution 10 MHz B-scan real time sonography. Arteriosclerotic plaques were usually semi-circular (77%), of high amplitude (64%) and homogeneous (80%). Ulcerating plaques were correctly diagnosed in only three out of eight cases demonstrated angiographically. So far there has been no definite relationship between the appearance of the plaques and clinical symptoms. Compared with arteriography (170 examinations) the specificity of sonography was 98% (62/63), the sensitivity for plaques was 100% (50/50), for stenoses it was 63% (5/8) to 93% (14/15), for occlusions it was 76% (13/17). The indications and drawbacks of the method are discussed.</description><identifier>ISSN: 1438-9029</identifier><identifier>PMID: 6429783</identifier><language>ger</language><publisher>Germany</publisher><subject>Carotid Artery Diseases - diagnosis ; Carotid Artery Diseases - diagnostic imaging ; Cerebral Angiography ; Humans ; Intracranial Arteriosclerosis - diagnosis ; Intracranial Arteriosclerosis - diagnostic imaging ; Ultrasonography</subject><ispartof>RöFo : Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebende Verfahren, 1984-06, Vol.140 (6), p.677-683</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/6429783$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kuhn, F P</creatorcontrib><creatorcontrib>Krämer, G</creatorcontrib><creatorcontrib>Bauer, R</creatorcontrib><creatorcontrib>Klotter, H J</creatorcontrib><title>10-MHz-B-scan sonography of the cervical carotid arteries</title><title>RöFo : Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebende Verfahren</title><addtitle>Rofo</addtitle><description>Two hundred and eighty-two consecutive patients with cerebro-vascular insufficiency, with non-specific neurological symptoms or asymptomatic murmurs, were examined prospectively by two-dimensional high resolution 10 MHz B-scan real time sonography. Arteriosclerotic plaques were usually semi-circular (77%), of high amplitude (64%) and homogeneous (80%). Ulcerating plaques were correctly diagnosed in only three out of eight cases demonstrated angiographically. So far there has been no definite relationship between the appearance of the plaques and clinical symptoms. Compared with arteriography (170 examinations) the specificity of sonography was 98% (62/63), the sensitivity for plaques was 100% (50/50), for stenoses it was 63% (5/8) to 93% (14/15), for occlusions it was 76% (13/17). The indications and drawbacks of the method are discussed.</description><subject>Carotid Artery Diseases - diagnosis</subject><subject>Carotid Artery Diseases - diagnostic imaging</subject><subject>Cerebral Angiography</subject><subject>Humans</subject><subject>Intracranial Arteriosclerosis - diagnosis</subject><subject>Intracranial Arteriosclerosis - diagnostic imaging</subject><subject>Ultrasonography</subject><issn>1438-9029</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1984</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNotj0FLwzAYhnNQ5pz-BCEnb4EkX5smRx3qBhMvu5c0-eIqbVOTTpi_3oI9vS8vDy88V2QtCtDMcGluyG3OX5wXXIBZkZUqpKk0rIkRnL3vftkzy84ONMchfiY7ni40BjqdkDpMP62zHXU2xan11KYJU4v5jlwH22W8X3JDjq8vx-2OHT7e9tunAxtLAKasa6SQvkKAoKqm0S4IDBI9cCVFmAfVoPTWc62K4DSUQRUVDzA340vYkMf_2zHF7zPmqe7b7LDr7IDxnGstZiPJYQYfFvDc9OjrMbW9TZd6UYU_hnVNww</recordid><startdate>198406</startdate><enddate>198406</enddate><creator>Kuhn, F P</creator><creator>Krämer, G</creator><creator>Bauer, R</creator><creator>Klotter, H J</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>7X8</scope></search><sort><creationdate>198406</creationdate><title>10-MHz-B-scan sonography of the cervical carotid arteries</title><author>Kuhn, F P ; Krämer, G ; Bauer, R ; Klotter, H J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p533-6acb212d7e33f67bb8cf1ef2ed30621fbb86be2dad0864fc835f6470f38359d53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>ger</language><creationdate>1984</creationdate><topic>Carotid Artery Diseases - diagnosis</topic><topic>Carotid Artery Diseases - diagnostic imaging</topic><topic>Cerebral Angiography</topic><topic>Humans</topic><topic>Intracranial Arteriosclerosis - diagnosis</topic><topic>Intracranial Arteriosclerosis - diagnostic imaging</topic><topic>Ultrasonography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kuhn, F P</creatorcontrib><creatorcontrib>Krämer, G</creatorcontrib><creatorcontrib>Bauer, R</creatorcontrib><creatorcontrib>Klotter, H J</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>MEDLINE - Academic</collection><jtitle>RöFo : Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebende Verfahren</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kuhn, F P</au><au>Krämer, G</au><au>Bauer, R</au><au>Klotter, H J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>10-MHz-B-scan sonography of the cervical carotid arteries</atitle><jtitle>RöFo : Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebende Verfahren</jtitle><addtitle>Rofo</addtitle><date>1984-06</date><risdate>1984</risdate><volume>140</volume><issue>6</issue><spage>677</spage><epage>683</epage><pages>677-683</pages><issn>1438-9029</issn><abstract>Two hundred and eighty-two consecutive patients with cerebro-vascular insufficiency, with non-specific neurological symptoms or asymptomatic murmurs, were examined prospectively by two-dimensional high resolution 10 MHz B-scan real time sonography. Arteriosclerotic plaques were usually semi-circular (77%), of high amplitude (64%) and homogeneous (80%). Ulcerating plaques were correctly diagnosed in only three out of eight cases demonstrated angiographically. So far there has been no definite relationship between the appearance of the plaques and clinical symptoms. Compared with arteriography (170 examinations) the specificity of sonography was 98% (62/63), the sensitivity for plaques was 100% (50/50), for stenoses it was 63% (5/8) to 93% (14/15), for occlusions it was 76% (13/17). The indications and drawbacks of the method are discussed.</abstract><cop>Germany</cop><pmid>6429783</pmid><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1438-9029
ispartof RöFo : Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebende Verfahren, 1984-06, Vol.140 (6), p.677-683
issn 1438-9029
language ger
recordid cdi_proquest_miscellaneous_81139203
source MEDLINE; Thieme Connect Journals
subjects Carotid Artery Diseases - diagnosis
Carotid Artery Diseases - diagnostic imaging
Cerebral Angiography
Humans
Intracranial Arteriosclerosis - diagnosis
Intracranial Arteriosclerosis - diagnostic imaging
Ultrasonography
title 10-MHz-B-scan sonography of the cervical carotid arteries
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T20%3A05%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=10-MHz-B-scan%20sonography%20of%20the%20cervical%20carotid%20arteries&rft.jtitle=R%C3%B6Fo%20:%20Fortschritte%20auf%20dem%20Gebiet%20der%20Ro%CC%88ntgenstrahlen%20und%20der%20bildgebende%20Verfahren&rft.au=Kuhn,%20F%20P&rft.date=1984-06&rft.volume=140&rft.issue=6&rft.spage=677&rft.epage=683&rft.pages=677-683&rft.issn=1438-9029&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E81139203%3C/proquest_pubme%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=81139203&rft_id=info:pmid/6429783&rfr_iscdi=true