Evaluation of Renal Functional Image Using Tc-99m DTPA
Functional Image (FI), which represents dynamic local renal function in one image, has been made possible only by digital image processing. The first FT obtained by rapid bolus injection of the radiolabeled medium is considered to be useful for evaluation of initial local renal blood flow. FT has th...
Gespeichert in:
Veröffentlicht in: | Kurume medical journal 1987/06/01, Vol.34(1), pp.43-47 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 47 |
---|---|
container_issue | 1 |
container_start_page | 43 |
container_title | Kurume medical journal |
container_volume | 34 |
creator | ISHIBASHI, MASATOSHI MORITA, SEIICHIRO UMEZAKI, NORIYOSHI YANO, KIYOSHI OHTAKE, HISASHI |
description | Functional Image (FI), which represents dynamic local renal function in one image, has been made possible only by digital image processing. The first FT obtained by rapid bolus injection of the radiolabeled medium is considered to be useful for evaluation of initial local renal blood flow. FT has the advantage that it can be performed simultaneously with conventional rou-tine examinations of the renal function. |
doi_str_mv | 10.2739/kurumemedj.34.43 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_81080759</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>81080759</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4373-528cb6ae6839ae667394c7268e929024957793395f7b59c4395f6ff0b41b33f73</originalsourceid><addsrcrecordid>eNpNUDtPwzAQthColMLOgpSJLcH2ObE9VqWFSpVAqJ0txzglJY9iJ0j8e1ylKix3p_sed_oQuiU4oRzkw2fv-trW9n2XAEsYnKExEYLEFEt8jsYYU4jTjMtLdOX9DmMmBMUjNAIgVGAyRtn8W1e97sq2idoierONrqJF35jDJozLWm9ttPFls43WJpayjh7Xr9NrdFHoytubY5-gzWK-nj3Hq5en5Wy6ig0DHk5TYfJM20yADDULLzPDaSaspBJTJlPOJYBMC56nMmjClBUFzhnJAQoOE3Q_-O5d-9Vb36m69MZWlW5s23slCBaYpzIQ8UA0rvXe2ULtXVlr96MIVoeo1F9UCphiECR3R-8-D-uT4JhNwJcDvvNdCOGEa9eVprL_DIlM2cGUDIXBiWM-tFO2gV-R236X</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>81080759</pqid></control><display><type>article</type><title>Evaluation of Renal Functional Image Using Tc-99m DTPA</title><source>MEDLINE</source><source>J-STAGE (Japan Science & Technology Information Aggregator, Electronic) Freely Available Titles - Japanese</source><creator>ISHIBASHI, MASATOSHI ; MORITA, SEIICHIRO ; UMEZAKI, NORIYOSHI ; YANO, KIYOSHI ; OHTAKE, HISASHI</creator><creatorcontrib>ISHIBASHI, MASATOSHI ; MORITA, SEIICHIRO ; UMEZAKI, NORIYOSHI ; YANO, KIYOSHI ; OHTAKE, HISASHI</creatorcontrib><description>Functional Image (FI), which represents dynamic local renal function in one image, has been made possible only by digital image processing. The first FT obtained by rapid bolus injection of the radiolabeled medium is considered to be useful for evaluation of initial local renal blood flow. FT has the advantage that it can be performed simultaneously with conventional rou-tine examinations of the renal function.</description><identifier>ISSN: 0023-5679</identifier><identifier>EISSN: 1881-2090</identifier><identifier>DOI: 10.2739/kurumemedj.34.43</identifier><identifier>PMID: 3312801</identifier><language>eng</language><publisher>Japan: Kurume University School of Medicine</publisher><subject>Adult ; Captopril ; Female ; Functional Image ; Glomerulonephritis - diagnostic imaging ; Humans ; Hydronephrosis - diagnostic imaging ; Hypertension, Renal - diagnostic imaging ; kidney ; Kidney - diagnostic imaging ; Male ; Organometallic Compounds ; Pentetic Acid ; Radionuclide Imaging ; Renal Circulation ; Tc-99m DTPA ; Technetium Tc 99m Pentetate</subject><ispartof>The Kurume Medical Journal, 1987/06/01, Vol.34(1), pp.43-47</ispartof><rights>THE KURUME MEDICAL JOURNAL</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,1883,4024,27923,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/3312801$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>ISHIBASHI, MASATOSHI</creatorcontrib><creatorcontrib>MORITA, SEIICHIRO</creatorcontrib><creatorcontrib>UMEZAKI, NORIYOSHI</creatorcontrib><creatorcontrib>YANO, KIYOSHI</creatorcontrib><creatorcontrib>OHTAKE, HISASHI</creatorcontrib><title>Evaluation of Renal Functional Image Using Tc-99m DTPA</title><title>Kurume medical journal</title><addtitle>Kurume Med. J.</addtitle><description>Functional Image (FI), which represents dynamic local renal function in one image, has been made possible only by digital image processing. The first FT obtained by rapid bolus injection of the radiolabeled medium is considered to be useful for evaluation of initial local renal blood flow. FT has the advantage that it can be performed simultaneously with conventional rou-tine examinations of the renal function.</description><subject>Adult</subject><subject>Captopril</subject><subject>Female</subject><subject>Functional Image</subject><subject>Glomerulonephritis - diagnostic imaging</subject><subject>Humans</subject><subject>Hydronephrosis - diagnostic imaging</subject><subject>Hypertension, Renal - diagnostic imaging</subject><subject>kidney</subject><subject>Kidney - diagnostic imaging</subject><subject>Male</subject><subject>Organometallic Compounds</subject><subject>Pentetic Acid</subject><subject>Radionuclide Imaging</subject><subject>Renal Circulation</subject><subject>Tc-99m DTPA</subject><subject>Technetium Tc 99m Pentetate</subject><issn>0023-5679</issn><issn>1881-2090</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1987</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpNUDtPwzAQthColMLOgpSJLcH2ObE9VqWFSpVAqJ0txzglJY9iJ0j8e1ylKix3p_sed_oQuiU4oRzkw2fv-trW9n2XAEsYnKExEYLEFEt8jsYYU4jTjMtLdOX9DmMmBMUjNAIgVGAyRtn8W1e97sq2idoierONrqJF35jDJozLWm9ttPFls43WJpayjh7Xr9NrdFHoytubY5-gzWK-nj3Hq5en5Wy6ig0DHk5TYfJM20yADDULLzPDaSaspBJTJlPOJYBMC56nMmjClBUFzhnJAQoOE3Q_-O5d-9Vb36m69MZWlW5s23slCBaYpzIQ8UA0rvXe2ULtXVlr96MIVoeo1F9UCphiECR3R-8-D-uT4JhNwJcDvvNdCOGEa9eVprL_DIlM2cGUDIXBiWM-tFO2gV-R236X</recordid><startdate>1987</startdate><enddate>1987</enddate><creator>ISHIBASHI, MASATOSHI</creator><creator>MORITA, SEIICHIRO</creator><creator>UMEZAKI, NORIYOSHI</creator><creator>YANO, KIYOSHI</creator><creator>OHTAKE, HISASHI</creator><general>Kurume University School of Medicine</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>1987</creationdate><title>Evaluation of Renal Functional Image Using Tc-99m DTPA</title><author>ISHIBASHI, MASATOSHI ; MORITA, SEIICHIRO ; UMEZAKI, NORIYOSHI ; YANO, KIYOSHI ; OHTAKE, HISASHI</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4373-528cb6ae6839ae667394c7268e929024957793395f7b59c4395f6ff0b41b33f73</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1987</creationdate><topic>Adult</topic><topic>Captopril</topic><topic>Female</topic><topic>Functional Image</topic><topic>Glomerulonephritis - diagnostic imaging</topic><topic>Humans</topic><topic>Hydronephrosis - diagnostic imaging</topic><topic>Hypertension, Renal - diagnostic imaging</topic><topic>kidney</topic><topic>Kidney - diagnostic imaging</topic><topic>Male</topic><topic>Organometallic Compounds</topic><topic>Pentetic Acid</topic><topic>Radionuclide Imaging</topic><topic>Renal Circulation</topic><topic>Tc-99m DTPA</topic><topic>Technetium Tc 99m Pentetate</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>ISHIBASHI, MASATOSHI</creatorcontrib><creatorcontrib>MORITA, SEIICHIRO</creatorcontrib><creatorcontrib>UMEZAKI, NORIYOSHI</creatorcontrib><creatorcontrib>YANO, KIYOSHI</creatorcontrib><creatorcontrib>OHTAKE, HISASHI</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Kurume medical journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>ISHIBASHI, MASATOSHI</au><au>MORITA, SEIICHIRO</au><au>UMEZAKI, NORIYOSHI</au><au>YANO, KIYOSHI</au><au>OHTAKE, HISASHI</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Evaluation of Renal Functional Image Using Tc-99m DTPA</atitle><jtitle>Kurume medical journal</jtitle><addtitle>Kurume Med. J.</addtitle><date>1987</date><risdate>1987</risdate><volume>34</volume><issue>1</issue><spage>43</spage><epage>47</epage><pages>43-47</pages><issn>0023-5679</issn><eissn>1881-2090</eissn><abstract>Functional Image (FI), which represents dynamic local renal function in one image, has been made possible only by digital image processing. The first FT obtained by rapid bolus injection of the radiolabeled medium is considered to be useful for evaluation of initial local renal blood flow. FT has the advantage that it can be performed simultaneously with conventional rou-tine examinations of the renal function.</abstract><cop>Japan</cop><pub>Kurume University School of Medicine</pub><pmid>3312801</pmid><doi>10.2739/kurumemedj.34.43</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0023-5679 |
ispartof | The Kurume Medical Journal, 1987/06/01, Vol.34(1), pp.43-47 |
issn | 0023-5679 1881-2090 |
language | eng |
recordid | cdi_proquest_miscellaneous_81080759 |
source | MEDLINE; J-STAGE (Japan Science & Technology Information Aggregator, Electronic) Freely Available Titles - Japanese |
subjects | Adult Captopril Female Functional Image Glomerulonephritis - diagnostic imaging Humans Hydronephrosis - diagnostic imaging Hypertension, Renal - diagnostic imaging kidney Kidney - diagnostic imaging Male Organometallic Compounds Pentetic Acid Radionuclide Imaging Renal Circulation Tc-99m DTPA Technetium Tc 99m Pentetate |
title | Evaluation of Renal Functional Image Using Tc-99m DTPA |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T16%3A29%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Evaluation%20of%20Renal%20Functional%20Image%20Using%20Tc-99m%20DTPA&rft.jtitle=Kurume%20medical%20journal&rft.au=ISHIBASHI,%20MASATOSHI&rft.date=1987&rft.volume=34&rft.issue=1&rft.spage=43&rft.epage=47&rft.pages=43-47&rft.issn=0023-5679&rft.eissn=1881-2090&rft_id=info:doi/10.2739/kurumemedj.34.43&rft_dat=%3Cproquest_cross%3E81080759%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=81080759&rft_id=info:pmid/3312801&rfr_iscdi=true |