In Vivo Comparison of Two Thermodilution Systems
Gespeichert in:
Veröffentlicht in: | Chest 1987-11, Vol.92 (5), p.926-928 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 928 |
---|---|
container_issue | 5 |
container_start_page | 926 |
container_title | Chest |
container_volume | 92 |
creator | Combs, D. Thomas Hanlon, J. Timothy |
description | |
doi_str_mv | 10.1378/chest.92.5.926 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_81072277</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0012369216308704</els_id><sourcerecordid>81072277</sourcerecordid><originalsourceid>FETCH-LOGICAL-c238t-bb60e4a12b1f86a69d1bf5b70a0771f5616c6c54bd4b78f6e3184bb9826763523</originalsourceid><addsrcrecordid>eNp1kL1PwzAQxS0EKqWwsiFlQGwJPjuxkxFVfFSqxEBhtWzHUY2SuNgpqP89Lo26sdzJfj-_8z2ErgFnQHl5r9cmDFlFsiIWdoKmUFFIaZHTUzTFGEhKWUXO0UUInzieoWITNKGMFQxgivCiTz7st0vmrttIb4PrE9ckqx-XrNbGd6627Xaw8fZtFwbThUt01sg2mKuxz9D70-Nq_pIuX58X84dlqgkth1Qphk0ugShoSiZZVYNqCsWxxJxDE4czzXSRqzpXvGyYoVDmSlUlYZzRgtAZujv4brz72sYdRWeDNm0re-O2QZSAOSGcRzA7gNq7ELxpxMbbTvqdACz2EYm_iERFRBELiw9uRuet6kx9xMdMon476jJo2TZe9tqGI8ZzgLzY25QHzMQUvq3xImhrem1q640eRO3sfz_4BdyGgZA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>81072277</pqid></control><display><type>article</type><title>In Vivo Comparison of Two Thermodilution Systems</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Combs, D. Thomas ; Hanlon, J. Timothy</creator><creatorcontrib>Combs, D. Thomas ; Hanlon, J. Timothy</creatorcontrib><identifier>ISSN: 0012-3692</identifier><identifier>EISSN: 1931-3543</identifier><identifier>DOI: 10.1378/chest.92.5.926</identifier><identifier>PMID: 3665611</identifier><identifier>CODEN: CHETBF</identifier><language>eng</language><publisher>Northbrook, IL: Elsevier Inc</publisher><subject>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy ; Biological and medical sciences ; Cardiac Output ; Emergency and intensive care: techniques, logistics ; Humans ; Intensive care medicine ; Medical sciences ; Monitoring ; Thermodilution - methods</subject><ispartof>Chest, 1987-11, Vol.92 (5), p.926-928</ispartof><rights>1987 The American College of Chest Physicians</rights><rights>1988 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c238t-bb60e4a12b1f86a69d1bf5b70a0771f5616c6c54bd4b78f6e3184bb9826763523</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=7411456$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/3665611$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Combs, D. Thomas</creatorcontrib><creatorcontrib>Hanlon, J. Timothy</creatorcontrib><title>In Vivo Comparison of Two Thermodilution Systems</title><title>Chest</title><addtitle>Chest</addtitle><subject>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</subject><subject>Biological and medical sciences</subject><subject>Cardiac Output</subject><subject>Emergency and intensive care: techniques, logistics</subject><subject>Humans</subject><subject>Intensive care medicine</subject><subject>Medical sciences</subject><subject>Monitoring</subject><subject>Thermodilution - methods</subject><issn>0012-3692</issn><issn>1931-3543</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1987</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp1kL1PwzAQxS0EKqWwsiFlQGwJPjuxkxFVfFSqxEBhtWzHUY2SuNgpqP89Lo26sdzJfj-_8z2ErgFnQHl5r9cmDFlFsiIWdoKmUFFIaZHTUzTFGEhKWUXO0UUInzieoWITNKGMFQxgivCiTz7st0vmrttIb4PrE9ckqx-XrNbGd6627Xaw8fZtFwbThUt01sg2mKuxz9D70-Nq_pIuX58X84dlqgkth1Qphk0ugShoSiZZVYNqCsWxxJxDE4czzXSRqzpXvGyYoVDmSlUlYZzRgtAZujv4brz72sYdRWeDNm0re-O2QZSAOSGcRzA7gNq7ELxpxMbbTvqdACz2EYm_iERFRBELiw9uRuet6kx9xMdMon476jJo2TZe9tqGI8ZzgLzY25QHzMQUvq3xImhrem1q640eRO3sfz_4BdyGgZA</recordid><startdate>198711</startdate><enddate>198711</enddate><creator>Combs, D. Thomas</creator><creator>Hanlon, J. Timothy</creator><general>Elsevier Inc</general><general>American College of Chest Physicians</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>198711</creationdate><title>In Vivo Comparison of Two Thermodilution Systems</title><author>Combs, D. Thomas ; Hanlon, J. Timothy</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c238t-bb60e4a12b1f86a69d1bf5b70a0771f5616c6c54bd4b78f6e3184bb9826763523</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1987</creationdate><topic>Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy</topic><topic>Biological and medical sciences</topic><topic>Cardiac Output</topic><topic>Emergency and intensive care: techniques, logistics</topic><topic>Humans</topic><topic>Intensive care medicine</topic><topic>Medical sciences</topic><topic>Monitoring</topic><topic>Thermodilution - methods</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Combs, D. Thomas</creatorcontrib><creatorcontrib>Hanlon, J. Timothy</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Chest</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Combs, D. Thomas</au><au>Hanlon, J. Timothy</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>In Vivo Comparison of Two Thermodilution Systems</atitle><jtitle>Chest</jtitle><addtitle>Chest</addtitle><date>1987-11</date><risdate>1987</risdate><volume>92</volume><issue>5</issue><spage>926</spage><epage>928</epage><pages>926-928</pages><issn>0012-3692</issn><eissn>1931-3543</eissn><coden>CHETBF</coden><cop>Northbrook, IL</cop><pub>Elsevier Inc</pub><pmid>3665611</pmid><doi>10.1378/chest.92.5.926</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0012-3692 |
ispartof | Chest, 1987-11, Vol.92 (5), p.926-928 |
issn | 0012-3692 1931-3543 |
language | eng |
recordid | cdi_proquest_miscellaneous_81072277 |
source | MEDLINE; Alma/SFX Local Collection |
subjects | Anesthesia. Intensive care medicine. Transfusions. Cell therapy and gene therapy Biological and medical sciences Cardiac Output Emergency and intensive care: techniques, logistics Humans Intensive care medicine Medical sciences Monitoring Thermodilution - methods |
title | In Vivo Comparison of Two Thermodilution Systems |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T19%3A48%3A20IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=In%20Vivo%20Comparison%20of%20Two%20Thermodilution%20Systems&rft.jtitle=Chest&rft.au=Combs,%20D.%20Thomas&rft.date=1987-11&rft.volume=92&rft.issue=5&rft.spage=926&rft.epage=928&rft.pages=926-928&rft.issn=0012-3692&rft.eissn=1931-3543&rft.coden=CHETBF&rft_id=info:doi/10.1378/chest.92.5.926&rft_dat=%3Cproquest_cross%3E81072277%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=81072277&rft_id=info:pmid/3665611&rft_els_id=S0012369216308704&rfr_iscdi=true |